1000 resultados para Eficiência energética. RTQ. Envoltória. Edifícios residenciaisverticais. Tipologias formais
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Eletrotécnica e de Computadores
Resumo:
Dissertação para obtenção do Grau de Mestre em Energias Renováveis – Conversão Elétrica e Utilização Sustentáveis
Resumo:
Dissertação para obtenção do Grau Mestre em Engenharia Civil Perfil de Construção
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
Energy efficiency has gained significant importance in recent years, mainly due to cyclical climatic conditions and current supply of natural resources. The present work deals with the procedures and requirements necessary to evaluate a building to a level of efficiency corresponding to your project and the actual implemented. To perform this analysis, we adopted the technical regulation efficiency prepared by Procel along with other agencies of the sector. The Regulation aims to create a model for the technical evaluation of the efficiency of buildings, popularize and expand the theme specification of conditions drawn up today. The building analyzed in this study was the library of UNESP, Guaratinguetá. Still, after the completion of the final efficiency analysis, are presented proposals for intervention that can improve and enhance the present situation of the building. The interventions are based on many technical factors and local conditions of climate and supply of resource. The issue of sustainability was explained in order to serve as a tool to expand the options available to upgrade a building in front of their impact on the environment
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
A presente dissertação é o resultado de um estudo realizado entre Março de 2015 e Março de 2016 centrado no tema Eficiência Energética nos Edifícios, no âmbito da Dissertação do 2º ano do Mestrado em Engenharia Eletrotécnica – Sistemas Elétricos de Energia no Instituto Superior de Engenharia do Porto (ISEP). Atualmente, os edifícios são responsáveis por cerca de 40% do consumo de energia na maioria dos países da europa. Energia consumida, principalmente, no aquecimento, arrefecimento e na alimentação de aparelhos elétricos. Os hospitais, como grandes edifícios, são grandes consumidores de energia e, na maioria dos países europeus, situam-se entre os edifícios públicos menos eficientes. Neste contexto, representam um tipo de edifícios cuja atividade apresenta um potencial de poupança energético importante. O tipo de atividade aí desenvolvida, aliada às especificidades do sector da saúde, faz deste tipo de edifícios um alvo de análise e otimização energética bastante apetecível. O presente trabalho passa pelo estudo do potencial para a eficiência energética de um hospital situado na zona do Porto. Foi, inicialmente, efetuado um levantamento das necessidades energéticas, de modo a identificar os sectores prioritários de atuação. Este estudo conta com a análise dos consumos obtidos através do processo de monitorização, substituição da iluminação existente por uma mais eficiente, a instalação de painéis solares para reduzir o consumo destinado às águas quentes sanitárias, a substituição de caldeira a diesel por caldeira a biomassa, substituição de um chiller por um mais eficiente, entre outros. Os consumos registados no hospital em estudo serão comparados com um plano nacional (Eficiência Energética e Hídrica no Sistema Nacional de Saúde), para, desta forma, se perceber quais os consumos do hospital em estudo, quando comparados com outros hospitais.
Resumo:
Building design is an effective way to achieve HVAC energy consumption reduction. However, this potentiality is often neglected by architects due to the lack of references to support design decisions. This works intends to propose architectural design guidelines for energy efficiency and thermal performance of Campus/UFRN buildings. These guidelines are based on computer simulations results using the software DesignBuilder. The definition of simulation models has begun with envelope variables, partially done after a field study of thirteen buildings at UFRN/Campus. This field study indicated some basic envelope patterns that were applied in simulation models. Occupation variables were identified with temperature and energy consumption monitoring procedures and a verification of illumination and equipment power, both developed at the Campus/UFRN administration building. Three simulation models were proposed according to different design phases and decisions. The first model represents early design decisions, simulating the combination of different types of geometry with three levels of envelope thermal performance. The second model, still as a part of early design phase, analyses thermal changes between circulation halls lateral and central and office rooms, as well as the heat fluxes and monthly temperatures in each circulation hall. The third model analyses the influence of middle-design and detail design decisions on energy consumption and thermal performance. In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window shading devices, office room orientation and absorptance of roof and walls surfaces
Resumo:
No presente trabalho apresenta-se um conceito de habitação, aplicado a uma casa do tipo Bungalow que alia a arquitetura, clima, e energias renováveis (Produção fotovoltaica e eólica), denominado Green Bungalow, para um agregado familiar de 3 pessoas. Para o efeito foram analisados e estudados princípios de arquitetura bioclimática, considerando e potencializando as condições climáticas existentes no local onde o conceito foi aplicado. Foram igualmente otimizados os respetivos consumos energéticos e construídos os respetivos diagramas de carga. São propostas soluções técnicas para a alimentação da carga dimensionada para o Green Bungalow para funcionamento em sistema isolado e ligado à rede elétrica de energia. Para averiguar a racionalidade económica do investimento teve-se em consideração os aspetos legislativos, tarifas e taxas em vigor (2011) respeitantes à microprodução. Efetuou-se uma análise de sensibilidade que, tendo por base uma solução técnica dimensionada para o consumo de 1890 kWh/ano, considerou os seguintes cenários: • Sensibilidade a diferentes níveis de consumo – 4000 kWh/ano e 6000 kWh/ano; • Sensibilidade a diferentes níveis de geração; • Sensibilidade a valores de custo do equipamento considerado para cada solução técnica exequível. Conclui-se que o conceito Green Bungalow é uma boa escolha do ponto de vista técnico e em termos ambientais. Da simulação da microprodução do caso de estudo comprovou-se que, para o atual enquadramento tarifário e custo de equipamento não existe viabilidade económica, sendo viável apenas para cenários de consumo muito elevados. Nesse cenário a tecnologia fotovoltaica de produção de energia apresentou-se a mais rentável em todas as simulações.
Resumo:
A destilação é o principal processo de separação usado nas indústrias químicas para separação de misturas líquidas, e apesar de ser um processo muito intensivo energeticamente continua hoje em dia a ser o processo de separação preferencial. O largo impacto dos processos de destilação nos custos de investimento e operação tem impulsionado o desenvolvimento de sistemas complexos de destilação, cuja principal finalidade consiste na otimização energética do processo de separação. No âmbito do estudo da utilização de colunas de elevada eficiência energética para separações multicomponente através da simulação de processos, o presente trabalho foca-se na compreensão, análise e avaliação da Coluna de Petlyuk, sistema de colunas com acoplamento térmico integral (FTCDC), inicialmente introduzida na década de 1940, com um reportado potencial para poupanças energéticas até cerca de 30% relativamente ao sistema tradicional. Para a simulação dos sistemas em estudo foi usado o software de simulação de processos HYSYS, cuja aplicação é desenvolvida e analisada no decurso deste trabalho, o qual é dividido em três partes principais: implementação dos processos em HYSYS para simulação rigorosa em modo de estado estacionário, otimização e simulação dinâmica e controlo. A primeira parte diz respeito ao design dos sistemas e âmbito de aplicação do HYSYS nesta etapa. Através do estudo da separação de mistura ternária equimolar de isómeros de butanol, é apresentado um procedimento de implementação do sistema FTCDC e avaliados os resultados de simulação rigorosa fazendo a sua comparação com os resultados obtidos para o sistema tradicional. A segunda parte é dedicada à otimização de ambos os sistemas, FTCDC e tradicional, cujos estudos se baseiam na simulação em estado estacionário. O elevado número de variáveis de design do sistema FTCDC pode conduzir a tedioso e moroso trabalho de simulação. Neste trabalho são aplicadas metodologias de desenho de experiências na otimização do sistema FTCDC, as quais permitiram uma significativa redução o número de simulações a executar, sendo o procedimento de otimização, baseado no procedimento de desenhos de experiências, desenvolvido ao longo desta parte. Os resultados de otimização de ambos os sistemas são avaliados e comparados. A última parte deste trabalho debruça-se sobre o tema da operabilidade dos sistemas, avaliada através da simulação dinâmica dos mesmos e avaliação da estrutura de controlo implementada. A simulação dinâmica de processos, baseada em modelos dinâmicos, permite melhorar o seu design, otimização e operação, cujos resultados traduzirão de uma forma mais realística o desempenho do processo desenhado, uma vez que estes nunca se encontram num verdadeiro estado estacionário. Nesta parte é apresentado o procedimento de implementação da simulação dinâmica de ambos os sistemas, no qual se inclui a definição da configuração de controlo para cada um destes. Através dos resultados de simulação dinâmica de ambos os sistemas é avaliado o seu design e respetiva estrutura de controlo.
Resumo:
Mestrado em Engenharia Química
Resumo:
Projecto para obtenção do grau de Mestre em Engenharia Informática e de computadores
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia