531 resultados para EMG
Resumo:
Mouth breathing may cause changes in muscle activity, because an upper airway obstruction leads may cause a person to extend his/her head forward, demanding a higher inspiratory effort on the accessory muscles (sternocleidomastoids). This purpose of this study is to compare, using electromyography (EMG), the activity pattern the sternocleidomastoid and upper trapezius muscles in mouth breathing children and nasal breathing children. Forty-six children, ages 8-12 years, 33 male and 13 female were included. The selected children were divided into two groups: Group I consisted of 26 mouth breathing children, and Group II, 20 nasal breathing children. EMG recordings were made using surface electrodes bilaterally in the areas of the sternocleidomastoideus and upper trapezius muscles, while relaxed and during maximal voluntary contraction. The data were analyzed using the Kruskall-Wallis statistical test. The results indicated higher activity during relaxation and lower activity during maximal voluntary contraction in mouth breathers when compared to the nasal breathers. It is suggested that the activity pattern of the sternocleidomastoid and upper trapezius muscles differs between mouth breathing children and nasal breathing children. This may be attributed to changes in body posture which causes muscular imbalance. Because of the limitations of surface EMG, the results need to be confirmed by adding force measurements and repeating the experiments with matched subjects. Copyright © 2004 by CHROMA, Inc.
Resumo:
The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.
Resumo:
The purpose of this randomized study was to evaluate EMG spectral, subjective and cardiovascular recovery parameters after isometric lumbar extension contractions. Ten healthy women performed isometric lumbar extensions until exhaustion with 5%, 10%, 15% and 20% of maximal voluntary isometric contraction on 4 different days (random order). One baseline five second contraction was performed before the fatiguing task which was followed by eight submaximal five second extension contractions (until 20 minutes after the end of the fatiguing task) at the same intensity as the trial to evaluate muscle recovery. EMG (Median Frequency, Peak Power, Peak Power Frequency, Total Power and Zero-crossing Rate) and cardiovascular variables did not demonstrate any statistical difference between the 5-second contractions (p > 0.05) performed before and after the fatiguing task, showing a quick EMG recovery. However, the data analysis showed that the perceived effort variable had not recovered even 10 minutes after the fatigue contraction (p < 0.05). Our results represent a data basis for future comparisons and since subjective felling can affect performance, this study shows the importance of its analysis, since the subjective effort rate was not fully recovered after 10 minutes the end of the exhaustion contraction. © 2008 IOS Press. All rights reserved.
Resumo:
Purpose. Isokinetic tests are often applied to assess muscular strength and EMG activity, however the specific ranges of motion used in testing (fully flexed or extended positions) might be constrictive and/or be painful for patients with injuries or under-going rehabilitation. The aim of this study was to examine the effects of different ranges of motion (RoM) when determining maximal EMG during isokinetic knee flexion and extension with different types of contractions and velocities. Methods. Eighteen males had EMG activity recorded on the vastus lateralis, vastus medialis, semitendinosus and biceps femoris muscles during five maximal isokinetic concentric and eccentric contractions for the knee flexors and extensors at 60° • s -1 and 180° • s -1. The root mean square of EMG was calculated at three different ranges of motion: (1) a full range of motion (90°-20° [0° = full knee extension]); (2) a range of motion of 20° (between 60°-80° and 40°-60° for knee extension and flexion, respectively) and (3) at a 10° interval around the angle where peak torque is produced. EMG measurements were statistically analyzed (ANOVA) to test for the range of motion, contraction velocity and contraction speed effects. Coefficients of variation and Pearson's correlation coefficients were also calculated among the ranges of motion. Results. Predominantly similar (p > 0.05) and well-correlated EMG results (r > 0.7, p ≤ 0.001) were found among the ranges of motion. However, a lower coefficient of variation was found for the full range of motion, while the 10° interval around peak torque at 180° • s -1 had the highest coefficient, regardless of the type of contraction. Conclusions. Shorter ranges of motion at around the peak torque angle provides a reliable indicator when recording EMG activity during maximal isokinetic parameters. It may provide a safer alternative when testing patients with injuries or undergoing rehabilitation.
Resumo:
This study aimed to analyze the electromyographic (EMG) activity of iliocostalis lumborum (IL), internal oblique (IO) and multifidus (MU) and the antagonist cocontraction (IO/MU and IO/IL) during the performance of Centering Principle of Pilates Method. Participating in this study were eighteen young and physically fit volunteers, without experience in Pilates Method, divided in two groups: low back pain group (LBPG, n = 8) and control group (CG, n = 10). Two isometric contractions of IO muscles (Centering Principle) were performed in upright sitting posture. EMG signal amplitude was calculated by Root Mean Square (RMS), which was normalized by RMS maximum value. The common area method to calculate the antagonist cocontraction index was used. MU and IO activation and IO/MU cocontraction (. p < 0.05) were higher in CG. The CG therefore showed a higher stabilizer muscles recruitment than LBPG during the performance of Centering Principle of Pilates Method. © 2012 Elsevier Ltd.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
The objective of the present study was to compare parameters such as total time, number of episodes and mean duration of episodes of each wake-sleep cycle stage, and sequences of stages in electroencephalographic records scored in 10 and 30 seconds epochs in controls and sleep deprived animals, submitted to avoiding tasks of learning and memory. This comparing tried to discuss the need of lesser epochs in the EEG scoring, and of the search for more details and shorter sequences, present in many studies nowadays
Resumo:
Patellofemoral pain syndrome (PFPS) is the most frequent complaint in orthopedic clinics; although, its etiology remains unclear [Bolgla, 2010; Felicio, 2011]. Trying to understand its causes has been used time analysis of electromyography (EMG), but this method shows controversies. The aim of this study was to apply a method of processing the EMG signal in the frequency domain of the vastus lateralis (VL) and vastus medialis (VM) muscles for the characterization of PFPS.
Resumo:
Objective To assess the diagnostic accuracy of the surface electromyography (sEMG) parameters associated with referred anterior knee pain in diagnosing patellofemoral pain syndrome (PFPS). Design Sensitivity and specificity analysis. Setting Physical rehabilitation center and laboratory of biomechanics and motor control. Participants Pain-free subjects (n=29) and participants with PFPS (n=22) selected by convenience. Interventions Not applicable. Main Outcome Measure The diagnostic accuracy was calculated for sEMG parameters’ reliability, precision, and ability to differentiate participants with and without PFPS. The selected sEMG parameter associated with anterior knee pain was considered as an index test and was compared with the reference standard for the diagnosis of PFPS. Intraclass correlation coefficient, SEM, independent t tests, sensitivity, specificity, negative and positive likelihood ratios, and negative and positive predictive values were used for the statistical analysis. Results The medium-frequency band (B2) parameter was reliable (intraclass correlation coefficient=.80–.90), precise (SEM=2.71–3.87 normalized unit), and able to differentiate participants with and without PFPS (P<.05). The association of B2 with anterior knee pain showed positive diagnostic accuracy values (specificity, .87; sensitivity, .70; negative likelihood ratio, .33; positive likelihood ratio, 5.63; negative predictive value, .72; and positive predictive value, .86). Conclusions The results provide evidence to support the use of EMG signals (B2 – frequency band of 45–96Hz) of the vastus lateralis and vastus medialis muscles with referred anterior knee pain in the diagnosis of PFPS.
Resumo:
The main questions addressed in this work were whether and how adaptation to suppression of visual information occurs in a free-fall paradigm, and the extent to which vision availability influences the control of landing movements. The prelanding modulation of EMG timing and amplitude of four lower-limb muscles was investigated. Participants performed six consecutive drop-landings from four different heights in two experimental conditions: with and without vision. Experimental design precluded participants from estimating the height of the drop. Since cues provided by proprioceptive and vestibular information acquired during the first trials were processed, the nervous system rapidly adapted to the lack of visual information, and hence produced a motor output (i.e., prelanding EMG modulation) similar to that observed when performing the activity with vision available.
Resumo:
Unstable shoes have been designed to promote "natural instability" and during walking they should simulate barefoot gait, enhancing muscle activity and, thus, attributing an advantage over regular tennis shoes. Recent studies showed that, after special training on the appropriate walking pattern, the use of the Masai Barefoot Technology (MBT) shoe increases muscle activation during walking. Our study presents a comparison of muscle activity as well as horizontal and vertical forces during gait with the MBT, a standard tennis shoe and barefoot walking of healthy individuals without previous training. These variables were compared in 25 female subjects and gait conditions were compared using ANOVA repeated measures (effect size:0.25). Walking with the MBT shoe in this non-instructed condition produced higher vertical forces (first vertical peak and weight acceptance rate) than walking with a standard shoe or walking barefoot, which suggests an increase in the loads received by the musculoskeletal system, especially at heel strike. Walking with the MBT shoe did not increase muscle activity when compared to walking with the standard shoe. The barefoot condition was more effective than the MBT shoe at enhancing muscle activation. Therefore, in healthy individuals, no advantage was found in using the MBT over a standard tennis shoe without a special training period. Further studies using the MBT without any instruction over a longer period are needed to evaluate if the higher loads observed in the present study would return to their baseline values after a period of adaptation, and if the muscle activity would increase over time. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
O objetivo deste estudo foi analisar a reprodutibilidade de parâmetros no domínio da frequência do sinal eletromiográfico (EMG) utilizados na caracterização da fadiga muscular localizada. Quinze sujeitos do sexo masculino foram submetidos a um teste de fadiga baseado na extensão isométrica de joelho, sendo realizados em três momentos distintos com intervalos de sete dias. Para avaliar a reprodutibilidade dos dados entres os testes calculou-se o coeficiente de correlação intraclasse (CCI) para a frequência mediana (Fmed) no tempo total de exercício (FmedT), para a Fmed obtida a cada 10% do tempo de exercício (Fmed10%) e para as potências das bandas de frequência, obtidas da divisão do espectro de potência a cada 20 Hz. Os resultados demonstraram: (1) boa reprodutibilidade para a FmedT; (2) boa reprodutibilidade para a Fmed10%; e (3) maior variação no sinal EMG nas bandas de 20 a 120 Hz, no qual se destacam as bandas de 20-40 Hz e de 40-60 Hz, demonstrando maior sensibilidade ao processo de fadiga muscular. Conclui-se que a Fmed é uma variável que apresenta boa reprodutibilidade e que a análise fragmentada do espectro de potência, por meio das bandas de frequência, demonstrou-se sensível as variações que ocorrem no sinal EMG durante a instalação do processo de fadiga, tendo potencial para se tornar um novo método para a caracterização da fadiga muscular localizada.
Resumo:
Abstract Study design Controlled laboratory study. Objectives The purposes of this paper were to investigate (d) whether vastus medialis obliquus (VMO), vastus lateralis longus (VLL) and vastus lateralis obliquus (VLO) EMG activity can be influenced by hip abduction performed by healthy subjects. Background Some clinicians contraindicate hip abduction for patellofemoral patients (with) based on the premise that hip abduction could facilitate the VLL muscle activation leading to a VLL and VMO imbalance Methods and measures Twenty-one clinically healthy subjects were involved in the study, 10 women and 11 men (aged X = 23.3 ± 2.9). The EMG signals were collected using a computerized EMG VIKING II, with 8 channels and three pairs of surface electrodes. EMG activity was obtained from MVIC knee extension at 90° of flexion in a seated position and MVIC hip abduction at 0° and 30° with patients in side-lying position with the knee in full extension. The data were normalized in the MVIC knee extension at 50° of flexion in a seated position, and were submitted to ANOVA test with subsequent application of the Bonferroni multiple comparisons analysis test. The level of significance was defined as p ≤ 0.05. Results The VLO muscle demonstrated a similar pattern to the VMO muscle showing higher EMG activity in MVIC knee extension at 90° of flexion compared with MVIC hip abduction at 0° and 30° of abduction for male (p < 0.0007) and MVIC hip abduction at 0° of abduction for female subjects (p < 0.02196). There were no statistically significant differences in the VLL EMG activity among the three sets of exercises tested. Conclusion The results showed that no selective EMG activation was observed when comparison was made between the VMO, VLL and VLO muscles while performing MVIC hip abduction at 0° and 30° of abduction and MVIC knee extension at 90° of flexion in both male and female subjects. Our findings demonstrate that hip abduction do not facilitated VLL and VLO activity in relation to the VMO, however, this study included only healthy subjects performing maximum voluntary isometric contraction contractions, therefore much remains to be discovered by future research
Resumo:
O objetivo do presente estudo foi comparar o sinal eletromiográfi co, a frequência e a amplitude de passada entre diferentes intensidades de corrida: 60%, 80% e 100% da velocidade máxima em dois protocolos incrementais. Participaram deste estudo 11 corredores do sexo masculino. Os protocolos de corrida foram realizados com velocidades iniciais de 10 km.hr-1, com incrementos de 1 km.hr-1 a cada três minutos até a exaustão, que diferiram em relação ao intervalo entre cada estágio incremental: 30 e 120 segundos. Foram analisados valores RMS dos músculos iliocostal lombar, reto femoral, vasto lateral, vasto medial, bíceps femoral, tibial anterior, e gastrocnêmio, e a amplitude e frequência de passada. Os valores RMS mostraram aumento entre as intensidades para quase todos os músculos, e não foram influenciados pelo tipo de protocolo utilizado para maioria dos músculos. A frequência e amplitude de passada apresentaram contribuições percentuais diferenciadas para o aumento da velocidade de corrida.