875 resultados para Dry eye syndromes
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
To report a case of extensive globe enlargement due to secondary glaucoma in a young adult suffering from ocular surface disorders related to hypohidrotic ectodermal dysplasia. To the best of our knowledge, this is the first report of buphthalmos in the adulthood.
Resumo:
Fundamentos: El elevado número de personas que trabajando con ordenador utiliza lentes de contacto plantea la cuestión sobre si la suma de estos dos factores de riesgo para la salud visual puede originar un agravamiento del Síndrome Visual Informático. El objetivo de esta revisión es sintetizar el conocimiento científico sobre las alteraciones oculares y visuales relacionadas con la exposición a ordenador en usuarios de lentes de contacto. Métodos: Revisión de artículos científicos (2003-2013) en español e inglés, realizando una búsqueda bibliográfica, en Medline a través de PubMed y en Scopus. Resultados: La búsqueda inicial aportó 114 trabajos, después de aplicar criterios de inclusión/exclusión se incluyeron seis artículos. Todos ellos ponen de manifiesto que las alteraciones al utilizar el ordenador son más frecuentes en las personas usuarias de lentes de contacto, con prevalencias que oscilan de 95,0% al 16,9% que en las que no utilizan lentes de contacto, cuya prevalencia va del 57,5% al 9,9% y con una probabilidad cuatro veces mayor de padecer ojo seco [OR: 4,07 (IC 95%: 3,52-4,71)]. Conclusiones: Las personas usuarias de ordenador padecen más alteraciones oculares y visuales cuando además son usuarias de lentes de contacto, pero los estudios son escasos y poco contundentes. Se precisan nuevas investigaciones que analicen la influencia según los tipos de lentes y sus condiciones de uso, tanto en la sintomatología como en la calidad de la lágrima y la superficie ocular. Las lentes de hidrogel de silicona son las que se asocian a mayor confort.
Resumo:
More information on the biochemical interactions taking place between the tear film and the contact lens is required to further our understanding of the causative mechanisms behind the symptoms of dryness and grittiness often experienced by contact lens wearers. These symptoms can often lead to an intolerance to contact lens wear.
Resumo:
Aim: To undertake a systematic review of the literature on the effect of environmental tobacco smoke (ETS) and eye disease. Methods: Medline (1950-January Week 2 2007), EMBASE (1980 to 2007 Week 07), SCOPUS and Science Direct were searched on ETS exposure and eye disease using various combinations of the following terms: passive smoking, environmental tobacco smoke, sidestream smoke, involuntary smoking, secondhand smoke; with eye, conjunctiva, sclera, episclera, cornea, lens, iris, retina, choroid, uvea, optic nerve, uveitis, iritis, blindness, visual loss, cataract, thyroid eye disease, conjunctivitis, age-related macular degeneration, dry eye, tears. The above terms were also used to search abstracts published on The Association for Research in Vision and Ophthalmology Annual Meeting abstracts, from 1995 to 2006, and the grey literature, including PhD and MSc theses/dissertations. A search was further conducted specifically on eye diseases where active smoking has been proposed to be a risk factor, including age-related macular degeneration, Graves ophthalmology, glaucoma, uveitis, refractive errors, strabismus, tobacco-alcohol amblyopia, non-arteritic ischaemic optic neuropathy, Leber optic neuropathy and diabetic retinopathy. Given the scarce number of studies found through the above search, all articles found on ETS and eye disease were included in this review. Results: Seven studies evaluated the possible relationship between ETS and an eye disease. These studies referred to refractive errors in children (n = 2), cataract (n = 1), age-related macular degeneration (n = 3) and Grave ophthalmopathy (n = 1). The data available were insufficient to establish conclusive relationships between ETS and these eye diseases. Conclusion: Very scarce data exist in the literature on the effect of ETS on diseases of the eye. It seems appropriate that ETS should be included in future studies addressing the effect of smoking on eye disease.
Resumo:
Multiple system atrophy (MSA) is a rare movement disorder and a member of the 'parkinsonian syndromes', which also include Parkinson's disease (PD), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB) and corticobasal degeneration (CBD). Multiple system atrophy is a complex syndrome, in which patients exhibit a variety of signs and symptoms, including parkinsonism, ataxia and autonomic dysfunction. It can be difficult to separate MSA from the other parkinsonian syndromes but if ocular signs and symptoms are present, they may aid differential diagnosis. Typical ocular features of MSA include blepharospasm, excessive square-wave jerks, mild to moderate hypometria of saccades, impaired vestibular-ocular reflex (VOR), nystagmus and impaired event-related evoked potentials. Less typical features include slowing of saccadic eye movements, the presence of vertical gaze palsy, visual hallucinations and an impaired electroretinogram (ERG). Aspects of primary vision such as visual acuity, colour vision or visual fields are usually unaffected. Management of the disease to deal with problems of walking, movement, daily tasks and speech problems is important in MSA. Optometrists can work in collaboration with the patient and health-care providers to identify and manage the patient's visual deficits. A more specific role for the optometrist is to correct vision to prevent falls and to monitor the anterior eye to prevent dry eye and control blepharospasm.
Resumo:
As we settle into a new year, this second issue of Contact Lens and Anterior Eye allows us to reflect on how new research in this field impacts our understanding, but more importantly, how we use this evidence basis to enhance our day to day practice, to educate the next generation of students and to construct the research studies to deepen our knowledge still further. The end of 2014 saw the publication of the UK governments Research Exercise Framework (REF) which ranks Universities in terms of their outputs (which includes their paper, publications and research income), environment (infrastructure and staff support) and for the first time impact (defined as “any effect on, change or benefit to the economy, society, culture, public policy or services, health, the environment or quality of life, beyond academia” [8]). The REF is a process of expert review, carried out in 36 subject-based units of assessment, of which our field is typically submitted to the Allied Health, Dentistry, Nursing and Pharmacy panel. Universities that offer Optometry did very well with Cardiff, Manchester and Aston in the top 10% out of the 94 Universities that submitted to this panel (Grade point Average ranked order). While the format of the new exercise (probably in 2010) to allocate the more than £2 billion of UK government research funds is yet to be determined, it is already rumoured that impact will contribute an even larger proportion to the weighting. Hence it is even more important to reflect on the impact of our research. In this issue, Elisseef and colleagues [5] examine the intriguing potential of modifying a lens surface to allow it to bind to known wetting agents (in this case hyaluronic acid) to enhance water retention. Such a technique has the capacity to reduced friction between the lens surface and the eyelids/ocular surface, presumably leading to higher comfort and less reason for patients to discontinue with lens wear. Several papers in this issue report on the validity of new high precision, fast scanning imaging and quantification equipment, utilising techniques such as Scheimpflug, partial coherence interferometry, aberrometry and video allowing detailed assessment of anterior chamber biometry, corneal topography, corneal biomechanics, peripheral refraction, ocular aberrations and lens fit. The challenge is how to use this advanced instrumentation which is becoming increasingly available to create real impact. Many challenges in contact lenses and the anterior eye still prevail in 2015 such as: -While contact lens and refractive surgery complications are relatively rare, they are still too often devastating to the individual and their quality of life (such as the impact and prognosis of patients with Acanthmoeba Keratitis reported by Jhanji and colleagues in this issue [7]). How can we detect those patients who are going to be affected and what modifications do we need to make to contact lenses and patient management prevent this occurring? -Drop out from contact lenses still occurs at a rapid rate and symptoms of dry eye seem to be the leading cause driving this discontinuation of wear [1] and [2]. What design, coating, material and lubricant release mechanism will make a step change in end of day comfort in particular? -Presbyopia is a major challenge to hassle free quality vision and is one of the first signs of ageing noticed by many people. As an emmetrope approaching presbyopia, I have a vested interest in new medical devices that will give me high quality vision at all distances when my arms won’t stretch any further. Perhaps a new definition of presbyopia could be when you start to orientate your smartphone in the landscape direction to gain the small increase in print size needed to read! Effective accommodating intraocular lenses that truly mimic the pre-presbyopic crystalline lenses are still a way off [3] and hence simultaneous images achieved through contact lenses, intraocular lenses or refractive surgery still have a secure future. However, splitting light reaching the retina and requiring the brain to supress blurred images will always be a compromise on contrast sensitivity and is liable to cause dysphotopsia; so how will new designs account for differences in a patient's task demands and own optical aberrations to allow focused patient selection, optimising satisfaction? -Drug delivery from contact lenses offers much in terms of compliance and quality of life for patients with chronic ocular conditions such as glaucoma, dry eye and perhaps in the future, dry age-related macular degeneration; but scientific proof-of-concept publications (see EIShaer et al. [6]) have not yet led to commercial products. Part of this is presumably the regulatory complexity of combining a medical device (the contact lens) and a pharmaceutical agent. Will 2015 be the year when this innovation finally becomes a reality for patients, bringing them an enhanced quality of life through their eye care practitioners and allowing researchers to further validate the use of pharmaceutical contact lenses and propose enhancements as the technology matures? -Last, but no means least is the field of myopia control, the topic of the first day of the BCLA's Conference in Liverpool, June 6–9th 2015. The epidemic of myopia is a blight, particularly in Asia, with significant concerns over sight threatening pathology resulting from the elongated eye. This is a field where real impact is already being realised through new soft contact lens optics, orthokeratology and low dose pharmaceuticals [4], but we still need to be able to better predict which technique will work best for an individual and to develop new techniques to retard myopia progression in those who don’t respond to current treatments, without increasing their risk of complications or the treatment impacting their quality of life So what will your New Year's resolution be to make 2015 a year of real impact, whether by advancing science or applying the findings published in journals such as Contact Lens and Anterior Eye to make a real difference to your patients’ lives?
Resumo:
Dinucleoside polyphosphates comprises a group of dinucleotides formed by two nucleosides linked by a variable number of phosphates, abbreviated NpnN (where n represents the number of phosphates). These compounds are naturally occurring substances present in tears, aqueous humour and in the retina. As the consequence of their presence, these dinucleotides contribute to many ocular physiological processes. On the ocular surface, dinucleoside polyphosphates can stimulate tear secretion, mucin release from goblet cells and they help epithelial wound healing by accelerating cell migration rate. These dinucleotides can also stimulate the presence of proteins known to protect the ocular surface against microorganisms, such as lysozyme and lactoferrin. One of the latest discoveries is the ability of some dinucleotides to facilitate the paracellular way on the cornea, therefore allowing the delivery of compounds, such as antiglaucomatous ones, more easily within the eye. The compound Ap4A has been described being abnormally elevated in patient's tears suffering of dry eye, Sjogren syndrome, congenital aniridia, or after refractive surgery, suggesting this molecule as biomarker for dry eye condition. At the intraocular level, some diadenosine polyphosphates are abnormally elevated in glaucoma patients, and this can be related to the stimulation of a P2Y2 receptor that increases the chloride efflux and water movement in the ciliary epithelium. In the retina, the dinucleotide dCp4U, has been proven to be useful to help in the recovery of retinal detachments. Altogether, dinucleoside polyphosphates are a group of compounds which present relevant physiological actions but which also can perform promising therapeutic benefits.
Resumo:
RESUMEN Objetivo: Estimar la prevalencia de las diferentes enfermedades oftalmológicas que aparecen en el contexto de una enfermedad autoinmune (EAI) en pacientes de un centro de referencia reumatológica en Colombia, según características clínicas y sociodemográficas durante un período de 15 años, comprendido entre los años 2000 a 2015. Métodos: Se realizó un estudio descriptivo, observacional de prevalencia. El tipo de muestreo fue aleatorio estratificado con asignación proporcional en el programa Epidat 3.4. Los datos se analizaron en el programa SPSS v22.0 y se realizó análisis univariado de las variables categóricas, para las variables cuantitativas se realizaron medidas de tendencia central. Resultados: De 1640 historias clínicas revisadas, se encontraron 634 pacientes (38,65%) con compromiso ocular. Si excluimos los pacientes con SS, que por definición presentan ojo seco, 222 pacientes (13,53%) presentaron compromiso oftalmológico. Del total de pacientes, el 83,3% fueron mujeres. La AR fue la enfermedad autoinmune con mayor compromiso oftalmológico con 138 pacientes (62,2%), y en último lugar la sarcoidosis con 1 solo paciente afectado. La QCS fue la manifestación más común en todos los grupos diagnósticos de EAI, con 146 pacientes (63,5%). De 414 pacientes con Síndrome de Sjögren (SS) y QCS 8 presentaron compromiso ocular adicional, siendo la uveítis la segunda patología ocular asociada en pacientes con SS y la primera causa en las espondiloartropatias (71,4 %). Los pacientes con catarata (4,1%) presentaron la mayor prevalencia de uso de corticoide (88.8%). De 222 pacientes, 28 (12,6%) presentaron uveítis. Del total de pacientes, 16 (7,2%) presentaron maculopatía por antimalaráricos y 6 (18,75%) de los pacientes con LES. Los ANAS se presentaron en el 100% los pacientes con trastorno vascular de la retina. Los pacientes con epiescleritis presentaron la mayor proporción de positivización de anticuerpos anti-DNA. La EAI que más presentó epiescleritis fue LES con 4 pacientes (12,5%) El 22% de paciente con anticuerpos anti-RNP presentaron escleritis y 32,1% de los pacientes con uveítis presentaron HLA-B27 positivo. Las manifestaciones oftalmológicas precedieron a las sistémicas entre un 11,1% y un 33,3% de los pacientes. Conclusión: Las enfermedades oculares se presentan con frecuencia en los pacientes colombianos con EAI (38.65%), siendo la AR la enfermedad con mayor compromiso ocular (62,2%) y la QCS la enfermedad ocular con mayor prevalencia en todas las EAI (63,5%). La uveítis se presentó en 28 pacientes (12,6%). Las manifestaciones oftalmológicas pueden preceder a las sistémicas. El examen oftalmológico debe ser incluido en los pacientes con EAI, por ser la enfermedad ocular una comorbilidad frecuente. Adicionalmente, los efectos oftalmológicos de las medicaciones sistémicas utilizadas en EAI deben ser estrechamente monitorizados, durante el curso del tratamiento.
Resumo:
Abstract—Corneal topography estimation that is based on the Placido disk principle relies on good quality of precorneal tear film and sufficiently wide eyelid (palpebral) aperture to avoid reflections from eyelashes. However, in practice, these conditions are not always fulfilled resulting in missing regions, smaller corneal coverage, and subsequently poorer estimates of corneal topography. Our aim was to enhance the standard operating range of a Placido disk videokeratoscope to obtain reliable corneal topography estimates in patients with poor tear film quality, such as encountered in those diagnosed with dry eye, and with narrower palpebral apertures as in the case of Asian subjects. This was achieved by incorporating in the instrument’s own topography estimation algorithm an image processing technique that comprises a polar-domain adaptive filter and amorphological closing operator. The experimental results from measurements of test surfaces and real corneas showed that the incorporation of the proposed technique results in better estimates of corneal topography, and, in many cases, to a significant increase in the estimated coverage area making such an enhanced videokeratoscope a better tool for clinicians.
Resumo:
Interferometry is a sensitive technique for recording tear film surface irregularities in a noninvasive manner. At the same time, the technique is hindered by natural eye movements resulting in measurement noise. Estimating tear film surface quality from interferograms can be reduced to a spatial-average-localized weighted estimate of the first harmonic of the interference fringes. However, previously reported estimation techniques proved to perform poorly in cases where the pattern fringes were significantly disturbed. This can occur in cases of measuring tear film surface quality on a contact lens on the eye or in a dry eye. We present a new estimation technique for extracting the first harmonic from the interference fringes that combines the traditional spectral estimation techniques with morphological image processing techniques. The proposed technique proves to be more robust to changes in interference fringes caused by natural eye movements and the degree of dryness of the contact lens and corneal surfaces than its predecessors, resulting in tear film surface quality estimates that are less noisy
Resumo:
The tear film plays an important role preserving the health of the ocular surface and maintaining the optimal refractive power of the cornea. Moreover dry eye syndrome is one of the most commonly reported eye health problems. This syndrome is caused by abnormalities in the properties of the tear film. Current clinical tools to assess the tear film properties have shown certain limitations. The traditional invasive methods for the assessment of tear film quality, which are used by most clinicians, have been criticized for the lack of reliability and/or repeatability. A range of non-invasive methods of tear assessment have been investigated, but also present limitations. Hence no “gold standard” test is currently available to assess the tear film integrity. Therefore, improving techniques for the assessment of the tear film quality is of clinical significance and the main motivation for the work described in this thesis. In this study the tear film surface quality (TFSQ) changes were investigated by means of high-speed videokeratoscopy (HSV). In this technique, a set of concentric rings formed in an illuminated cone or a bowl is projected on the anterior cornea and their reflection from the ocular surface imaged on a charge-coupled device (CCD). The reflection of the light is produced in the outer most layer of the cornea, the tear film. Hence, when the tear film is smooth the reflected image presents a well structure pattern. In contrast, when the tear film surface presents irregularities, the pattern also becomes irregular due to the light scatter and deviation of the reflected light. The videokeratoscope provides an estimate of the corneal topography associated with each Placido disk image. Topographical estimates, which have been used in the past to quantify tear film changes, may not always be suitable for the evaluation of all the dynamic phases of the tear film. However the Placido disk image itself, which contains the reflected pattern, may be more appropriate to assess the tear film dynamics. A set of novel routines have been purposely developed to quantify the changes of the reflected pattern and to extract a time series estimate of the TFSQ from the video recording. The routine extracts from each frame of the video recording a maximized area of analysis. In this area a metric of the TFSQ is calculated. Initially two metrics based on the Gabor filter and Gaussian gradient-based techniques, were used to quantify the consistency of the pattern’s local orientation as a metric of TFSQ. These metrics have helped to demonstrate the applicability of HSV to assess the tear film, and the influence of contact lens wear on TFSQ. The results suggest that the dynamic-area analysis method of HSV was able to distinguish and quantify the subtle, but systematic degradation of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions. Thus, the HSV method appears to be a useful technique for quantitatively investigating the effects of contact lens wear on the TFSQ. Subsequently a larger clinical study was conducted to perform a comparison between HSV and two other non-invasive techniques, lateral shearing interferometry (LSI) and dynamic wavefront sensing (DWS). Of these non-invasive techniques, the HSV appeared to be the most precise method for measuring TFSQ, by virtue of its lower coefficient of variation. While the LSI appears to be the most sensitive method for analyzing the tear build-up time (TBUT). The capability of each of the non-invasive methods to discriminate dry eye from normal subjects was also investigated. The receiver operating characteristic (ROC) curves were calculated to assess the ability of each method to predict dry eye syndrome. The LSI technique gave the best results under both natural blinking conditions and in suppressed blinking conditions, which was closely followed by HSV. The DWS did not perform as well as LSI or HSV. The main limitation of the HSV technique, which was identified during the former clinical study, was the lack of the sensitivity to quantify the build-up/formation phase of the tear film cycle. For that reason an extra metric based on image transformation and block processing was proposed. In this metric, the area of analysis was transformed from Cartesian to Polar coordinates, converting the concentric circles pattern into a quasi-straight lines image in which a block statistics value was extracted. This metric has shown better sensitivity under low pattern disturbance as well as has improved the performance of the ROC curves. Additionally a theoretical study, based on ray-tracing techniques and topographical models of the tear film, was proposed to fully comprehend the HSV measurement and the instrument’s potential limitations. Of special interested was the assessment of the instrument’s sensitivity under subtle topographic changes. The theoretical simulations have helped to provide some understanding on the tear film dynamics, for instance the model extracted for the build-up phase has helped to provide some insight into the dynamics during this initial phase. Finally some aspects of the mathematical modeling of TFSQ time series have been reported in this thesis. Over the years, different functions have been used to model the time series as well as to extract the key clinical parameters (i.e., timing). Unfortunately those techniques to model the tear film time series do not simultaneously consider the underlying physiological mechanism and the parameter extraction methods. A set of guidelines are proposed to meet both criteria. Special attention was given to a commonly used fit, the polynomial function, and considerations to select the appropriate model order to ensure the true derivative of the signal is accurately represented. The work described in this thesis has shown the potential of using high-speed videokeratoscopy to assess tear film surface quality. A set of novel image and signal processing techniques have been proposed to quantify different aspects of the tear film assessment, analysis and modeling. The dynamic-area HSV has shown good performance in a broad range of conditions (i.e., contact lens, normal and dry eye subjects). As a result, this technique could be a useful clinical tool to assess tear film surface quality in the future.