980 resultados para Document imaging system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose and demonstrate, for the first time to our best knowledge, the use of a 45° tilted fiber grating (TFG) as an infiber lateral diffraction element in an efficient and fiber-compatible spectrally encoded imaging (SEI) system. Under proper polarization control, the TFG has significantly enhanced diffraction efficiency (93.5%) due to strong tilted reflection. Our conceptually new fiber-topics-based design eliminates the need for bulky and lossy free-space diffraction gratings, significantly reduces the volume and cost of the imaging system, improves energy efficiency, and increases system stability. As a proof-of-principle experiment, we use the proposed system to perform an one dimensional (1D) line scan imaging of a customer-designed three-slot sample and the results show that the constructed image matches well with the actual sample. The angular dispersion of the 45° TFG is measured to be 0.054°/nm and the lateral resolution of the SEI system is measured to be 28 μm in our experiment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Creació d¿un software de gestió de factures electròniques desenvolupat en aquesta plataforma tecnològica, amb indicació expressa d¿utilització de les eines VSTO (Visual Studio Tools for Office) en la seva última versió.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'objectiu d'aquest projecte és el d'integrar les aplicacions de Microsoft Office (Excel, Word i Access) mitjançant. NET i la creació de documents / plantilles necessàries per tal de crear un entorn que permeti a un professional / empresa gestionar de manera automatitzada les factures que envia als seus clients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El projecte genera un entorn personalitzat de gestió de factures electròniques utilitzant Visual Studio Tools, l¿entorn permet gestionar les bases de dades dels clients i dels productes oferts, generar factures i enviar-les via correu electrònic als clients en diferents formats (PDF o Word).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El present treball de final de carrera s¿ha realitzat en el context de l¿àrea temàtica .NET amb l¿objectiu de crear una aplicació basada en aquesta plataforma tecnològica, utilitzant VSTO (Visual Studio Tools for Office) i generant documentsamb certificat digital.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En la present memòria es presenta el treball realitzat en el projecte de desenvolupament de l'aplicació efactura que pretén fer la gestió de les factures de forma electrònica, sense l'ús de paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El projecte que s'ha desenvolupat és la gestió de factures amb firma electrònica, on la finalitat és integrar una aplicació completament funcional a la suit d'ofimàtica Microsoft Office, amb certs requisits com la firma amb certificat digital, la qual cosa fa que les factures sigui vàlides per Hisenda.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 300 GHz radar imaging system is presented, including descriptions of the radar sensor and antenna subsystems. The antenna consists of a Bifocal Ellipsoidal Gregorian Reflector whose beam is scanned by a combination of the rotation and vertical tilting of a flat small secondary mirror. A prototype is being mounted and its characterization will be presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Spaceborne/airborne synthetic aperture radar (SAR) systems provide high resolution two-dimensional terrain imagery. The paper proposes a technique for combining multiple SAR images, acquired on flight paths slightly separated in the elevation direction, to generate high resolution three-dimensional imagery. The technique could be viewed as an extension to interferometric SAR (InSAR) in that it generates topographic imagery with an additional dimension of resolution. The 3-D multi-pass SAR imaging system is typically characterised by a relatively short ambiguity length in the elevation direction. To minimise the associated ambiguities we exploit the relative phase information within the set of images to track the terrain landscape. The SAR images are then coherently combined, via a nonuniform DFT, over a narrow (in elevation) volume centred on the 'dominant' terrain ground plane. The paper includes a detailed description of the technique, background theory, including achievable resolution, and the results of an experimental study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer among women all over the world. An important issue that is not commonly addressed in breast cancer imaging literature is the importance of imaging the underarm region—where up to 80% of breast cancer cells can metastasise to. The first axillary lymph nodes to receive drainage from the primary tumour in the breast are called Sentinel Node. If cancer cells are found in the Sentinel Node, there is an increased risk of metastatic breast cancer which makes this evaluation crucial to decide what follow-up exams and therapy to follow. However, non-invasive detection of cancer cells in the lymph nodes is often inconclusive, leading to the surgical removal of too many nodes which causes adverse side-effects for patients. Microwave Imaging is one of the most promising non-invasive imaging modalities for breast cancer early screening and monitoring. This novel study tests the feasibility of imaging the axilla region by means of the simulation of an Ultra-Wideband Microwave Imaging system. Simulations of such system are completed in several 2D underarm models that mimic the axilla. Initial imaging results are obtained by means of processing the simulated backscattered signals by eliminating artefacts caused by the skin and beamforming the processed signals in order to time-align all the signals recorded at each antenna. In this dissertation several image formation algorithms are implemented and compared by visual inspection of the resulting images and through a range of performance metrics, such as Signal-to-Clutter Ratio and FullWidth Half Maximum calculations. The results in this study showed that Microwave Imaging is a promising technique that might allow to identify the presence and location of metastasised cancer cells in axillary lymph nodes, enabling the non-invasive evaluation of breast cancer staging.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

El projecte Microscòpia d'alta resolució aplicada a anàlisis traceològiques, tafonòmiques y zooarqueològiques ha permès donar continuïtat i ampliar la xarxa científica posada en marxa gràcies a dos projectes PBR anteriors entre l’IPHES i quatre centres anglesos: l’Institute of Archaeology del University College of London, el Dept of Prehistory and Europe del British Museum, el Dept of Palaeontology del Natural History Museum, i el Lithic Microwear Research Laboratory de la University of Bradford. El tema tractat ha estat l’avaluació de la resolució i de la possible complementarietat de diferents tècniques avançades de microscòpia per a l’anàlisi de les superfícies d’ossos i eines de pedra prehistòriques: microscòpia òptica, electrònica (SEM i ESEM), microscòpia làser confocal (LSCM) i el sistema Alicona 3D Infinite Imaging. Les diverses accions de mobilitat entre Catalunya i el Regne Unit realitzades han permès satisfactòriament posar en comú els procediments emprats pels diferents especialistes de cada centre. Les proves realitzades sobre materials de jaciments arqueològics clau tant britànics com de l’estat espanyol han permès avaluar els avantatges i limitacions que cada tècnica presentava segons la mostra estudiada (eines de pedra, ossos, dents...) i segons els requeriments específics de l’estudi plantejat. En termes generals, s’ha posat en evidència que les diferents tècniques explorades són força complementàries. És a dir, la gran capacitat d’augments i de resolució d’imatge dels microscopis electrònics es complementa amb unes meravelloses prestacions quant anàlisi de textures, de perfils i de reconstrucció 3D dels altres aparells. La principal conclusió que podem extreure, doncs, és que l’estudi d’aquest tipus d’objectes arqueològics requereix de l’ús combinat de diferents aparells de microscòpia. Tant els treballs realitzats com els contactes entre especialistes establerts al llarg del projecte s’han plasmat ja en treballs concrets, alguns d’ells ja publicats o en fase final de publicació.