901 resultados para Digital light signal
Resumo:
We present crystal structures of the Anabaena sensory rhodopsin transducer (ASRT), a soluble cytoplasmic protein that interacts with the first structurally characterized eubacterial retinylidene photoreceptor Anabaena sensory rhodopsin (ASR). Four crystal structures of ASRT from three different spacegroups were obtained, in all of which ASRT is present as a planar (C4) tetramer, consistent with our characterization of ASRT as a tetramer in solution. The ASRT tetramer is tightly packed, with large interfaces where the well-structured beta-sandwich portion of the monomers provides the bulk of the tetramer-forming interactions, and forms a flat, stable surface on one side of the tetramer (the beta-face). Only one of our four different ASRT crystals reveals a C-terminal alpha-helix in the otherwise all-beta protein, together with a large loop from each monomer on the opposite face of the tetramer (the alpha-face), which is flexible and largely disordered in the other three crystal forms. Gel-filtration chromatography demonstrated that ASRT forms stable tetramers in solution and isothermal microcalorimetry showed that the ASRT tetramer binds to ASR with a stoichiometry of one ASRT tetramer per one ASR photoreceptor with a K(d) of 8 microM in the highest affinity measurements. Possible mechanisms for the interaction of this transducer tetramer with the ASR photoreceptor via its flexible alpha-face to mediate transduction of the light signal are discussed.
Resumo:
We present a secondary eclipse observation for the hot Jupiter HD 189733b across the wavelength range 290-570 nm made using the Space Telescope Imaging Spectrograph on the Hubble Space Telescope. We measure geometric albedos of Ag = 0.40 ± 0.12 across 290-450 nm and Ag < 0.12 across 450-570 nm at 1σ confidence. The albedo decrease toward longer wavelengths is also apparent when using six wavelength bins over the same wavelength range. This can be interpreted as evidence for optically thick reflective clouds on the dayside hemisphere with sodium absorption suppressing the scattered light signal beyond ~450 nm. Our best-fit albedo values imply that HD 189733b would appear a deep blue color at visible wavelengths.
Resumo:
Digital light, fluorescence and electron microscopy in combination with wavelength-dispersive spectroscopy were used to visualize individual polymers, air voids, cement phases and filler minerals in a polymer-modified cementitious tile adhesive. In order to investigate the evolution and processes involved in formation of the mortar microstructure, quantifications of the phase distribution in the mortar were performed including phase-specific imaging and digital image analysis. The required sample preparation techniques and imaging related topics are discussed. As a form of case study, the different techniques were applied to obtain a quantitative characterization of a specific mortar mixture. The results indicate that the mortar fractionates during different stages ranging from the early fresh mortar until the final hardened mortar stage. This induces process-dependent enrichments of the phases at specific locations in the mortar. The approach presented provides important information for a comprehensive understanding of the functionality of polymer-modified mortars.
Resumo:
We proposed an optical communications system, based on a digital chaotic signal where the synchronization of chaos was the main objective, in some previous papers. In this paper we will extend this work. A way to add the digital data signal to be transmitted onto the chaotic signal and its correct reception, is the main objective. We report some methods to study the main characteristics of the resulting signal. The main problem with any real system is the presence of some retard between the times than the signal is generated at the emitter at the time when this signal is received. Any system using chaotic signals as a method to encrypt need to have the same characteristics in emitter and receiver. It is because that, this control of time is needed. A method to control, in real time the chaotic signals, is reported.
Resumo:
La tecnología moderna de computación ha permitido cambiar radicalmente la investigación tecnológica en todos los ámbitos. El proceso general utilizado previamente consistía en el desarrollo de prototipos analógicos, creando múltiples versiones del mismo hasta llegar al resultado adecuado. Este es un proceso costoso a nivel económico y de carga de trabajo. Es por ello por lo que el proceso de investigación actual aprovecha las nuevas tecnologías para lograr el objetivo final mediante la simulación. Gracias al desarrollo de software para la simulación de distintas áreas se ha incrementado el ritmo de crecimiento de los avances tecnológicos y reducido el coste de los proyectos en investigación y desarrollo. La simulación, por tanto, permite desarrollar previamente prototipos simulados con un coste mucho menor para así lograr un producto final, el cual será llevado a cabo en su ámbito correspondiente. Este proceso no sólo se aplica en el caso de productos con circuitería, si bien es utilizado también en productos programados. Muchos de los programas actuales trabajan con algoritmos concretos cuyo funcionamiento debe ser comprobado previamente, para después centrarse en la codificación del mismo. Es en este punto donde se encuentra el objetivo de este proyecto, simular algoritmos de procesado digital de la señal antes de la codificación del programa final. Los sistemas de audio están basados en su totalidad en algoritmos de procesado de la señal, tanto analógicos como digitales, siendo estos últimos los que están sustituyendo al mundo analógico mediante los procesadores y los ordenadores. Estos algoritmos son la parte más compleja del sistema, y es la creación de nuevos algoritmos la base para lograr sistemas de audio novedosos y funcionales. Se debe destacar que los grupos de desarrollo de sistemas de audio presentan un amplio número de miembros con cometidos diferentes, separando las funciones de programadores e ingenieros de la señal de audio. Es por ello por lo que la simulación de estos algoritmos es fundamental a la hora de desarrollar nuevos y más potentes sistemas de audio. Matlab es una de las herramientas fundamentales para la simulación por ordenador, la cual presenta utilidades para desarrollar proyectos en distintos ámbitos. Sin embargo, en creciente uso actualmente se encuentra el software Simulink, herramienta especializada en la simulación de alto nivel que simplifica la dificultad de la programación en Matlab y permite desarrollar modelos de forma más rápida. Simulink presenta una completa funcionalidad para el desarrollo de algoritmos de procesado digital de audio. Por ello, el objetivo de este proyecto es el estudio de las capacidades de Simulink para generar sistemas de audio funcionales. A su vez, este proyecto pretende profundizar en los métodos de procesado digital de la señal de audio, logrando al final un paquete de sistemas de audio compatible con los programas de edición de audio actuales. ABSTRACT. Modern computer technology has dramatically changed the technological research in multiple areas. The overall process previously used consisted of the development of analog prototypes, creating multiple versions to reach the proper result. This is an expensive process in terms of an economically level and workload. For this reason actual investigation process take advantage of the new technologies to achieve the final objective through simulation. Thanks to the software development for simulation in different areas the growth rate of technological progress has been increased and the cost of research and development projects has been decreased. Hence, simulation allows previously the development of simulated protoypes with a much lower cost to obtain a final product, which will be held in its respective field. This process is not only applied in the case of circuitry products, but is also used in programmed products. Many current programs work with specific algorithms whose performance should be tested beforehand, which allows focusing on the codification of the program. This is the main point of this project, to simulate digital signal processing algorithms before the codification of the final program. Audio systems are entirely based on signal processing, both analog and digital systems, being the digital systems which are replacing the analog world thanks to the processors and computers. This algorithms are the most complex part of every system, and the creation of new algorithms is the most important step to achieve innovative and functional new audio systems. It should be noted that development groups of audio systems have a large number of members with different roles, separating them into programmers and audio signal engineers. For this reason, the simulation of this algorithms is essential when developing new and more powerful audio systems. Matlab is one of the most important tools for computer simulation, which has utilities to develop projects in different areas. However, the use of the Simulink software is constantly growing. It is a simulation tool specialized in high-level simulations which simplifies the difficulty of programming in Matlab and allows the developing of models faster. Simulink presents a full functionality for the development of algorithms for digital audio processing. Therefore, the objective of this project is to study the posibilities of Simulink to generate funcional audio systems. In turn, this projects aims to get deeper into the methods of digital audio signal processing, making at the end a software package of audio systems compatible with the current audio editing software.
Resumo:
Los procesadores tradicionales de un solo núcleo han tenido que enfrentarse a grandes desafíos para poder mejorar su rendimiento y eficiencia energética. Mientras tanto, el rápido avance de las tecnologías de fabricación ha permitido la implementación de varios procesadores en un solo chip, ofreciendo un alto rendimiento y eficiencia energética. Éstos son los llamados procesadores multinúcleo. El objetivo de este proyecto es realizar un sistema multiprocesador para el procesamiento digital de señales de radio. Este sistema multiprocesador puede ser implementado en una tarjeta de prototipado. Para ello se ha utilizado el softcore MB-Lite y el sistema operativo en tiempo real FreeRTOS. ABSTRACT. Traditional single-core processors have faced great challenges to improve their performance and energy efficiency. Meanwhile, rapid advancing fabrication technologies have enabled the implementation of several processors in a single chip, providing high performance and energy efficiency. These are called multi-core processors. The aim of this project is to perform a multiprocessor system for digital radio signal processing. This multiprocessor system can be implemented in a general purpose prototyping card using. To achieve this project, the MB-Lite softcore and the FreeRTOS real time operating system have been used.
Resumo:
Este trabajo de investigación trata de aportar luz al estudio del tiempo de reacción (TR) en velocistas con y sin discapacidad auditiva desde las Ciencias del Deporte. El planteamiento del presente estudio surgió al cuestionarnos la existencia de las diferencias en cuanto al TR visual y auditivo aplicado a velocistas con y sin discapacidad auditiva, pensando en el desarrollo futuro de competiciones inclusivas entre ambos colectivos. Por ello, este estudio trata de resolver las dificultades que los velocistas con discapacidad se encuentran habitualmente en las competiciones. A priori, los atletas con discapacidad auditiva compiten en inferioridad de condiciones como consecuencia de una salida que no parece la más adecuada para ellos (desde los tacos, han de mirar hacia la pistola del juez o el movimiento de un rival). El documento se divide en tres partes. En la primera parte se realiza la pertinente revisión del marco teórico y justificación del estudio. La segunda parte se centra en los objetivos de la investigación, el material y el método, donde se muestran los resultados, discusión y conclusiones del estudio realizado, así como las limitaciones del presente trabajo y sus futuras líneas de investigación. La tercera parte corresponde a la bibliografía y la cuarta parte a los anexos. En la primera parte, presentamos el marco teórico compuesto por cinco capítulos organizan la fundamentación que hemos realizado como revisión sobre los aspectos más destacados del TR, determinado por las características de la tarea y otros factores que influyen en el TR como objeto de nuestro estudio. Después exponemos los principales aspectos estructurales y funcionales del sistema nervioso (SN) relacionados con el TR visual y auditivo. Tras ello se expone la realidad del deporte para personas con discapacidad auditiva, indagando en sus peculiaridades y criterios de elegibilidad que tiene ese colectivo dentro del ámbito deportivo. A continuación abordamos el estudio de la salida de velocidad en el atletismo, como aspecto clave que va a guiar nuestra investigación, especialmente los parámetros determinantes en la colocación de los tacos de salida para atletas con y sin discapacidad auditiva, la posición de salida y la propia colocación de los estímulos en dicha situación. Es la segunda parte se desarrolla el trabajo de investigación que tiene como objetivos estudiar los valores de TR visual simple manual, TR en salida de tacos y los tiempos de desplazamiento a los 10m y 20m de velocistas con y sin discapacidad auditiva, así como analizar las posibles diferencias en TR según posición y tipo de estímulo luminoso, respecto a ambos grupos de atletas. Como tercer objetivo de estudio se evalúa cualitativamente, por parte de los propios atletas, el dispositivo luminoso utilizado. La toma de datos de este estudio se llevó a cabo entre los meses de febrero y mayo del 2014, en el módulo de atletismo del Centro de Alto Rendimiento Joaquín Blume (Madrid), con dos grupos de estudio, uno de 9 velocistas con discapacidad auditiva (VDA), conformando éstos el 60% de toda la población en España, según el número de las licencias de la FEDS en la modalidad de atletismo (velocistas, pruebas de 100 y 200 m.l.), en el momento del estudio, y otro de 13 velocistas sin discapacidad (VsDA) que se presentaron de manera voluntaria con unos mismos criterios de inclusión para ambos grupos. Para la medición y el registro de los datos se utilizaron materiales como hoja de registro, Medidor de Tiempo de Reacción (MTR), tacos de salida, ReacTime®, dispositivo luminoso conectado a los tacos de salida, células fotoeléctricas, ordenador y software del ReacTime, y cámara de video. La metodología utilizada en este estudio fue de tipo correlacional, analizando los resultados del TR simple manual según vía sensitiva (visual y auditiva) entre los dos grupos de VDA y VsDA. También se estudiaron los TR desde la salida de tacos en función de la colocación del dispositivo luminoso (en el suelo y a 5 metros, vía visual) y pistola de salida atlética (vía auditiva) así como el tiempo de desplazamiento a los 10m (t10m) y 20m (t20m) de ambos grupos de velocistas. Finalmente, se desarrolló y llevó a cabo un cuestionario de evaluación por parte de los atletas VDA con el objetivo de conocer el grado de satisfacción después de haber realizado la serie de experimentos con el dispositivo luminoso y adaptado para sistemas de salida en la velocidad atlética. Con el objetivo de comprobar la viabilidad de la metodología descrita y probar en el contexto de análisis real el protocolo experimental, se realizó un estudio piloto con el fin de conocer las posibles diferencias del TR visual desde los tacos de salida en velocistas con discapacidad auditiva, usando para dicha salida un estímulo visual mediante un dispositivo luminoso coordinado con la señal sonora de salida (Soto-Rey, Pérez-Tejero, Rojo-González y Álvarez-Ortiz, 2015). En cuanto a los procedimientos estadísticos utilizados, con el fin de analizar la distribución de los datos y su normalidad, se aplicó la prueba de Kolmogorov-Smirnof, dicha prueba arrojó resultados de normalidad para todas las variables analizadas de las situaciones experimentales EA, EVsuelo y EV5m. Es por ello que en el presente trabajo de investigación se utilizó estadística paramétrica. Como medidas descriptivas, se calcularon el máximo, mínimo, media y la desviación estándar. En relación a las situaciones experimentales, para estudiar las posibles diferencias en las variables estudiadas dentro de cada grupo de velocistas (intragrupo) en la situación experimental 1 (MTR), se empleó una prueba T de Student para muestras independientes. En las situaciones experimentales 2, 3 y 4, para conocer las diferencias entre ambos grupos de velocistas en cada situación, se utilizó igualmente la prueba T para muestras independientes, mientras que un ANOVA simple (con post hoc Bonferroni) se utilizó para analizar las diferencias para cada grupo (VDA y VsDA) por situación experimental. Así mismo, se utilizó un ANOVA de medidas repetidas, donde el tipo de estímulo (situación experimental) fue la variable intra-grupo y el grupo de velocistas participantes (VDA y VsDA) la entre-grupo, realizándose esta prueba para evaluar en cada situación el TR, t1m0 y t20m y las interacciones entre las variables. Para el tratamiento estadístico fue utilizado el paquete estadístico SPSS 18.0 (Chicago, IL, EEUU). Los niveles de significación fueron establecidos para un ≤0.05, indicando el valor de p en cada caso. Uno de los aspectos más relevantes de este trabajo es la medición en diferentes situaciones, con instrumentación distinta y con situaciones experimentales distintas, del TR en velocistas con y sin discapacidad auditiva. Ello supuso el desarrollo de un diseño de investigación que respondió a las necesidades planteadas por los objetivos del estudio, así como el desarrollo de instrumentación específica (Rojo-Lacal, Soto-Rey, Pérez-Tejero y Rojo-González, 2014; Soto-Rey et al., 2015) y distintas situaciones experimentales que reprodujeran las condiciones de práctica y competición real de VsDA y VDA en las pruebas atléticas de velocidad, y más concretamente, en las salidas. El análisis estadístico mostró diferencias significativas entre los estímulos visuales y sonoros medidos con el MTR, siendo menor el TR ante el estímulo visual que ante el sonoro, tanto para los atletas con discapacidad auditiva como para los que no la presentaron (TR visual, 0.195 s ± 0.018 vs 0.197 s ± 0.022, p≤0.05; TR sonoro 0.230 s ± 0.016 vs 0.237 s ± 0.045, p≤0.05). Teniendo en cuenta los resultados según población objeto de estudio y situación experimental, se registraron diferencias significativas entre ambas poblaciones, VDA y VsDA, siendo más rápidos los VDA que VsDA en la situación experimental con el estímulo visual en el suelo (EVsuelo, 0.191 ±0.025 vs 0.210 ±0.025, p≤0.05, respectivamente) y los VsDA en la situación experimental con el estímulo auditivo (EA, 0.396 ±0.045 vs 0.174 ±0.021, p≤0.05), aunque sin diferencias entre ambos grupos en la situación experimental con el estímulo visual a 5m de los tacos de salida. Es de destacar que en el TR no hubo diferencias significativas entre EA para VsDA y EVsuelo para VDA. El ANOVA simple registró diferencias significativas en todas las situaciones experimentales dentro de cada grupo y para todas las variables, por lo que estadísticamente, las situaciones experimentales fueron diferentes entre sí. En relación al de ANOVA medidas repetidas, la prueba de esfericidad se mostró adecuada, existiendo diferencias significativas en las varianzas de los pares de medias: el valor de F indicó que existieron diferencias entre las diferentes situaciones experimentales en cuanto a TR, incluso cuando éstas se relacionaban con el factor discapacidad (factor interacción, p≤0,05). Por ello, queda patente que las situaciones son distintas entre sí, también teniendo en cuenta la discapacidad. El η2 (eta al cuadrado, tamaño del efecto, para la interacción) indica que el 91.7% de la variación se deben a las condiciones del estudio, y no al error (indicador de la generalización de los resultados del estudio). Por otro lado, la evaluación del dispositivo luminoso fue positiva en relación a la iluminación, comodidad de uso, ubicación, color, tamaño, adecuación del dispositivo y del equipamiento necesario para adaptar al sistema de salida. La totalidad de los atletas afirman rotundamente que el dispositivo luminoso favorecería la adaptación al sistema de salida atlética para permitir una competición inclusiva. Asimismo concluyen que el dispositivo luminoso favorecería el rendimiento o mejora de marca en la competición. La discusión de este estudio presenta justificación de las diferencias demostradas que el tipo de estímulo y su colocación son clave en el TR de esta prueba, por lo que podríamos argumentar la necesidad de contar con dispositivos luminosos para VDA a la hora de competir con VsDA en una misma prueba, inclusiva. El presente trabajo de investigación ha demostrado, aplicando el método científico, que el uso de estos dispositivos, en las condiciones técnicas y experimentales indicadas, permite el uso por parte del VDA, usando su mejor TR visual posible, que se muestra similar (ns) al TR auditivo de VsDA, lo que indica que, para competiciones inclusivas, la salida usando el semáforo (para VDA) y la salida habitual (estímulo sonoro) para VsDA, puede ser una solución equitativa en base a la evidencia demostrada en este estudio. De esta manera, y como referencia, indicar que la media de los TR de los velocistas en la final de los 100 m.l. en los Juegos Olímpicos de Londres 2012 fue de 0.162 ±0.015. De esta manera, creemos que estos parámetros sirven de referencia a técnicos deportivos, atletas y futuros trabajos de investigación. Las aplicaciones de este trabajo permitirán modificaciones y reflexiones en forma de apoyo al entrenamiento y la competición para el entrenador, o juez de salida en la competición que, creemos, es necesaria para proporcionar a este colectivo una atención adecuada en las salidas, especialmente en situaciones inclusivas de práctica. ABSTRACT This research aims to study of reaction time (RT) in sprinters with and without hearing impairment from the Sports Science perspective. The approach of this study came asking whether there were differences in the visual and auditory RT applied to sprinters with and without hearing impairment, thinking about the future development of inclusive competition between the two groups. Therefore, this study attempts to resolve the difficulties commonly founded by sprinters with hearing impairments during competitions. A priori, sprinters with hearing impairment would compete in a disadvantage situation as a result of the use of a staring signal not suitable for them (from the blocks, they have to look to the judge´s pistol or the movement of an opponent). The document is divided into three parts. In the first part of the review of relevant theoretical framework and justification of the study is presented. The second part focuses on the research objectives, material and method, where results, discussion and conclusions of the study, as well as the limitations of this study and future research are presented. The third part contains references and the fourth, annexes. In the first part, we present the theoretical framework consisting of five chapters, organizing the state of the art of RT, determined by the characteristics of the task and other factors that influence the RT as object of our study. Then we present the main structural and functional aspects of the nervous system associated with visual and auditory RT. After that, sport for people with hearing disabilities is presented, investigating its peculiarities and eligibility criteria is that group within the deaf sport. Finally, we discuss the theoretical foundation of the study of start speed in athletics as a key aspect that will guide our research, especially the determining parameters in placing the starting blocks for athletes with and without hearing impairment, the starting position and the actual placement of stimuli in such a situation. The second part of the research aims to study the values of simple manual visual RT, RT start from blocks and travel times up to 10m and 20m of sprinters with and without hearing impairment, and to analyze possible differences in RT as position and type of light stimulus with respect to both groups of athletes. The third objective of the study is to assess the pertinence of the lighting device developed and used in the study, in a qualitatively way by athletes themselves. Data collection for this study was carried out between February and May 2014, in the Athletics module at the High Performance Centre Joaquin Blume (Madrid) with the two study groups: 9 sprinters with hearing impairments(VDA, reaching 60% of the population in Spain, according to the number of licenses for athletics at FEDS: sprint, 100 and 200 m.l., at the time of the study), and another 13 sprinters without disability (VsDA) who voluntarily presented themselves, with same inclusion criteria for both groups. For measuring and data collection materials such as recording sheet, gauge reaction time (MTR), starting blocks, ReacTime®, luminous device connected to the starting blocks, photocells, computer and software ReacTime, and video camera were used. The methodology used in this study was correlational, analyzing the results of simple manual RT according sensory pathway (visual and auditory) between the two groups (VsDA and VDA). Also auditory and visual RT was studied depending the placement of the start light signal (on the ground and 5 meters, visual pathway) and athletic start gun signal (auditory pathway, conventional situation) and travel time up to 10m (t10m) and 20m (t20m) for both groups of sprinters. Finally, we developed and carried out an evaluation questionnaire for VDA athletes in order to determine the degree of satisfaction after completing the series of experiments with lighting device and adapted to start systems in athletic speed. In order to test the feasibility of the methodology described and tested in the context of real analysis of the experimental protocol, a pilot study in order to know the possible differences visual RT from the starting blocks in sprinters with hearing impairments was performed, to said output using a visual stimulus coordinated by a lighting device with sound output signal (Soto-Rey Perez-Tejero, Rojo-González y Álvarez-Ortiz, 2015). For the statistical procedures, in order to analyze the distribution of the data and their normality, Kolmogorov-Smirnov test was applied, this test yielded normal results for all variables analyzed during EA, EVsuelo and EV5m experimental situations. Parametric statistics were used in this research. As descriptive measures, the maximum, minimum, mean and standard deviation were calculated. In relation to experimental situations, to study possible differences in the variables studied in each group sprinters (intragroup) in the experimental situation 1 (MTR), a Student t test was used for independent samples. Under the experimental situations 2, 3 and 4, to know the differences between the two groups of sprinters in every situation, the T test for independent samples was used, while a simple ANOVA (with post hoc Bonferroni) was used to analyze differences for each group (VDA and VsDA) by experimental situation. Likewise, a repeated measures ANOVA, where the type of stimulus (experimental situation) was variable intra-group and participants sprinters group (VDA and VsDA) the variable between-group, was performed to assess each situation for RT, t10m and t20m, and also interactions between variables. For the statistical treatment SPSS 18.0 (Chicago, IL, USA) was used. Significance levels were set for ≤0.05, indicating the value of p in each case. One of the most important aspects of this work is the measurement of RT in sprinters with and without hearing impairment in different situations, with different instrumentation and different experimental situations. This involved the development of a research design that responded to the needs raised by the study aims and the development of specific instrumentation (Rojo-Lacal, Soto-Rey Perez-Tejero and Rojo-Gonzalez, 2014; Soto-Rey et al., 2015) and different experimental situations to reproduce the conditions of practical and real competition VsDA and VDA in athletic sprints, and more specifically, at the start. Statistical analysis showed significant differences between the visual and sound stimuli measured by the MTR, with lower RT to the visual stimulus that for sound, both for athletes with hearing disabilities and for those without (visual RT, 0.195 s ± 0.018 s vs 0.197 ± 0.022, p≤0.05; sound RT 0.230 s ± 0.016 vs 0.237 s ± 0.045, p≤0.05). Considering the results according to study population and experimental situation, significant differences between the two populations, VDA and VsDA were found, being faster the VDA than VsDA in the experimental situation with the visual stimulus on the floor (EVsuelo, recorded 0.191 s ± 0.025 vs 0.210 s ± 0.025, p≤0.05, respectively) and VsDA in the experimental situation with the auditory stimulus (EA, 0.396 s ± 0.045 vs 0.174 s ± 0.021, p≤0.05), but no difference between groups in the experimental situation with the 5m visual stimulus to the starting blocks. It is noteworthy that no significant differences in EA and EVsuelo between VsDA to VDA, respectively, for RT. Simple ANOVA showed significant differences in all experimental situations within each group and for all variables, so statistically, the experimental situations were different. Regarding the repeated measures ANOVA, the sphericity test showed adequate, and there were significant differences in the variances of the pairs of means: the value of F indicated that there were differences between the different experimental situations regarding RT, even when they were related to the disability factor (factor interaction, p≤0.05). Therefore, it is clear that the situations were different from each other, also taking into account impairment. The η2 (eta squared, effect size, for interaction) indicates that 91.7% of the variation is due to the conditions of the study, not by error (as indicator of the generalization potential of the study results). On the other hand, evaluation of the light signal was positively related to lighting, ease of use, location, color, size, alignment device and equipment necessary to adapt the start system. All the athletes claim strongly in favor of the lighting device adaptation system to enable athletic competition inclusive. Also they concluded that light device would enhance performance or would decrease their RT during the competition. The discussion of this study justify the type of stimulus and the start light positioning as key to the RT performance, so that we could argue the need for lighting devices for VDA when competing against VsDA the same competition, inclusive. This research has demonstrated, applying the scientific method, that the use of these devices, techniques and given experimental conditions, allows the use of the VDA, using his best visual RT, shown similar (ns) auditory RT of VsDA, indicating that for inclusive competitions, the start signal using the light (for VDA) and the usual start (sound stimulus) to VsDA can be an equitable solution based on the evidence shown in this study. Thus, and as a reference, indicate that the average of the RT sprinters in the 100 m. final at the 2012 Summer Olympic Games was 0.162 s ± 0.015. Thus, we believe that these parameters become a reference to sports coaches, athletes and future research. Applications of this work will allow modifications and reflections in the form of support for training and competition for the coach, or judge, as we believe is necessary to provide adequate attention to VDA in speed starts, especially in inclusive practice situations.
Resumo:
Phosphoenolpyruvate carboxylase (PEPC) activity was detected in aleurone-endosperm extracts of barley (Hordeum vulgare) seeds during germination, and specific anti-sorghum (Sorghum bicolor) C4 PEPC polyclonal antibodies immunodecorated constitutive 103-kD and inducible 108-kD PEPC polypeptides in western analysis. The 103- and 108-kD polypeptides were radiolabeled in situ after imbibition for up to 1.5 d in 32P-labeled inorganic phosphate. In vitro phosphorylation by a Ca2+-independent PEPC protein kinase (PK) in crude extracts enhanced the enzyme's velocity and decreased its sensitivity to l-malate at suboptimal pH and [PEP]. Isolated aleurone cell protoplasts contained both phosphorylated PEPC and a Ca2+-independent PEPC-PK that was partially purified by affinity chromatography on blue dextran-agarose. This PK activity was present in dry seeds, and PEPC phosphorylation in situ during imbibition was not affected by the cytosolic protein-synthesis inhibitor cycloheximide, by weak acids, or by various pharmacological reagents that had proven to be effective blockers of the light signal transduction chain and PEPC phosphorylation in C4 mesophyll protoplasts. These collective data support the hypothesis that this Ca2+-independent PEPC-PK was formed during maturation of barley seeds and that its presumed underlying signaling elements were no longer operative during germination.
Resumo:
The sorghum (Sorghum bicolor L. Moench) cultivar 58M, which contains the null mutant phytochrome B gene, shows reduced photoperiodic sensitivity and exhibits a shade-avoidance phenotype. Ethylene production by seedlings of wild-type and phytochrome B mutant cultivars was monitored every 3 h, and both cultivars were found to produce ethylene in a circadian rhythm, with peak production occurring during the day. The phytochrome B mutant produces rhythmic peaks of ethylene with approximately 10 times the amplitude of the wild-type counterpart with the same period and diurnal timing. The source of the mutant's additional ethylene is the shoot. The diurnal rhythm can be produced with either light or temperature cycles; however, both light and temperature cycles are required for circadian entrainment. The temperature signal overrides the light signal in the production of diurnal rhythms, because seedlings grown under thermoperiods reversed with the photoperiod produced ethylene peaks during the warm nights. To examine the effect of extreme shading on ethylene production, seedlings were grown under dim, far-red-enriched light. This treatment duplicated the phytochrome B mutant's shade-avoidance phenotype in the wild type and caused the wild type to produce ethylene peaks similar to those observed in the mutant. The results confirm that phytochrome B is not required for proper function of circadian timing, but it may be involved in modulating physiological rhythms driven by the biological clock oscillator.
Resumo:
DGq is the alpha subunit of the heterotrimeric GTPase (G alpha), which couples rhodopsin to phospholipase C in Drosophila vision. We have uncovered three duplicated exons in dgq by scanning the GenBank data base for unrecognized coding sequences. These alternative exons encode sites involved in GTPase activity and G beta-binding, NorpA (phospholipase C)-binding, and rhodopsin-binding. We examined the in vivo splicing of dgq in adult flies and find that, in all but the male gonads, only two isoforms are expressed. One, dgqA, is the original visual isoform and is expressed in eyes, ocelli, brain, and male gonads. The other, dgqB, has the three novel exons and is widely expressed. Remarkably, all three nonvisual B exons are highly similar (82% identity at the amino acid level) to the Gq alpha family consensus, from Caenorhabditis elegans to human, but all three visual A exons are divergent (61% identity). Intriguingly, we have found a third isoform, dgqC, which is specifically and abundantly expressed in male gonads, and shares the divergent rhodopsin-binding exon of dgqA. We suggest that DGqC is a candidate for the light-signal transducer of a testes-autonomous photosensory clock. This proposal is supported by the finding that rhodopsin 2 and arrestin 1, two photoreceptor-cell-specific genes, are also expressed in male gonads.
Resumo:
The combination of the third-order optical nonlinearity with chromatic dispersion in optical fibers offers an extremely rich variety of possibilities for tailoring the temporal and spectral content of a light signal, depending on the regime of dispersion that is used. Here, we review recent progress on the use of third-order nonlinear processes in optical fibers for pulse shaping in the temporal and spectral domains. Various examples of practical significance will be discussed, spanning fields from the generation of specialized temporal waveforms to the generation of ultrashort pulses, and to stable continuum generation.
Resumo:
The use of electrocardiogram nowadays, is very important in diagnosis of heart disease. The emergent increase of portable technology provides medica] monitoring of vital signs allowing freedom ofmovement and watching during normal activity of the patient. In this shidy, it is described the development of a prototype of an ambulatory cardiac monitoring system using 3 leads. The systems consists on conversion of an analog signal, having been previously processed and conditioned, into digital ECG signal and after processed with a microcontroller (MCU). The heartbeat rate can be observed in an LCD display. The LCD display is also used as the interface during the setup process. Ali digital data stream can be stored on a SD memory card llowing the ECG signa] to be accessed later on a PC.
Resumo:
This thesis presents an investigation on endoscopic optical coherence tomography (OCT). As a noninvasive imaging modality, OCT emerges as an increasingly important diagnostic tool for many clinical applications. Despite of many of its merits, such as high resolution and depth resolvability, a major limitation is the relatively shallow penetration depth in tissue (about 2∼3 mm). This is mainly due to tissue scattering and absorption. To overcome this limitation, people have been developing many different endoscopic OCT systems. By utilizing a minimally invasive endoscope, the OCT probing beam can be brought to the close vicinity of the tissue of interest and bypass the scattering of intervening tissues so that it can collect the reflected light signal from desired depth and provide a clear image representing the physiological structure of the region, which can not be disclosed by traditional OCT. In this thesis, three endoscope designs have been studied. While they rely on vastly different principles, they all converge to solve this long-standing problem.
A hand-held endoscope with manual scanning is first explored. When a user is holding a hand- held endoscope to examine samples, the movement of the device provides a natural scanning. We proposed and implemented an optical tracking system to estimate and record the trajectory of the device. By registering the OCT axial scan with the spatial information obtained from the tracking system, one can use this system to simply ‘paint’ a desired volume and get any arbitrary scanning pattern by manually waving the endoscope over the region of interest. The accuracy of the tracking system was measured to be about 10 microns, which is comparable to the lateral resolution of most OCT system. Targeted phantom sample and biological samples were manually scanned and the reconstructed images verified the method.
Next, we investigated a mechanical way to steer the beam in an OCT endoscope, which is termed as Paired-angle-rotation scanning (PARS). This concept was proposed by my colleague and we further developed this technology by enhancing the longevity of the device, reducing the diameter of the probe, and shrinking down the form factor of the hand-piece. Several families of probes have been designed and fabricated with various optical performances. They have been applied to different applications, including the collector channel examination for glaucoma stent implantation, and vitreous remnant detection during live animal vitrectomy.
Lastly a novel non-moving scanning method has been devised. This approach is based on the EO effect of a KTN crystal. With Ohmic contact of the electrodes, the KTN crystal can exhibit a special mode of EO effect, termed as space-charge-controlled electro-optic effect, where the carrier electron will be injected into the material via the Ohmic contact. By applying a high voltage across the material, a linear phase profile can be built under this mode, which in turn deflects the light beam passing through. We constructed a relay telescope to adapt the KTN deflector into a bench top OCT scanning system. One of major technical challenges for this system is the strong chromatic dispersion of KTN crystal within the wavelength band of OCT system. We investigated its impact on the acquired OCT images and proposed a new approach to estimate and compensate the actual dispersion. Comparing with traditional methods, the new method is more computational efficient and accurate. Some biological samples were scanned by this KTN based system. The acquired images justified the feasibility of the usage of this system into a endoscopy setting. My research above all aims to provide solutions to implement an OCT endoscope. As technology evolves from manual, to mechanical, and to electrical approaches, different solutions are presented. Since all have their own advantages and disadvantages, one has to determine the actual requirements and select the best fit for a specific application.
Resumo:
Recent research has indicated that the pupil diameter (PD) in humans varies with their affective states. However, this signal has not been fully investigated for affective sensing purposes in human-computer interaction systems. This may be due to the dominant separate effect of the pupillary light reflex (PLR), which shrinks the pupil when light intensity increases. In this dissertation, an adaptive interference canceller (AIC) system using the H∞ time-varying (HITV) adaptive algorithm was developed to minimize the impact of the PLR on the measured pupil diameter signal. The modified pupil diameter (MPD) signal, obtained from the AIC was expected to reflect primarily the pupillary affective responses (PAR) of the subject. Additional manipulations of the AIC output resulted in a processed MPD (PMPD) signal, from which a classification feature, PMPDmean, was extracted. This feature was used to train and test a support vector machine (SVM), for the identification of stress states in the subject from whom the pupil diameter signal was recorded, achieving an accuracy rate of 77.78%. The advantages of affective recognition through the PD signal were verified by comparatively investigating the classification of stress and relaxation states through features derived from the simultaneously recorded galvanic skin response (GSR) and blood volume pulse (BVP) signals, with and without the PD feature. The discriminating potential of each individual feature extracted from GSR, BVP and PD was studied by analysis of its receiver operating characteristic (ROC) curve. The ROC curve found for the PMPDmean feature encompassed the largest area (0.8546) of all the single-feature ROCs investigated. The encouraging results seen in affective sensing based on pupil diameter monitoring were obtained in spite of intermittent illumination increases purposely introduced during the experiments. Therefore, these results confirmed the benefits of using the AIC implementation with the HITV adaptive algorithm to isolate the PAR and the potential of using PD monitoring to sense the evolving affective states of a computer user.
Resumo:
Recent research has indicated that the pupil diameter (PD) in humans varies with their affective states. However, this signal has not been fully investigated for affective sensing purposes in human-computer interaction systems. This may be due to the dominant separate effect of the pupillary light reflex (PLR), which shrinks the pupil when light intensity increases. In this dissertation, an adaptive interference canceller (AIC) system using the H∞ time-varying (HITV) adaptive algorithm was developed to minimize the impact of the PLR on the measured pupil diameter signal. The modified pupil diameter (MPD) signal, obtained from the AIC was expected to reflect primarily the pupillary affective responses (PAR) of the subject. Additional manipulations of the AIC output resulted in a processed MPD (PMPD) signal, from which a classification feature, PMPDmean, was extracted. This feature was used to train and test a support vector machine (SVM), for the identification of stress states in the subject from whom the pupil diameter signal was recorded, achieving an accuracy rate of 77.78%. The advantages of affective recognition through the PD signal were verified by comparatively investigating the classification of stress and relaxation states through features derived from the simultaneously recorded galvanic skin response (GSR) and blood volume pulse (BVP) signals, with and without the PD feature. The discriminating potential of each individual feature extracted from GSR, BVP and PD was studied by analysis of its receiver operating characteristic (ROC) curve. The ROC curve found for the PMPDmean feature encompassed the largest area (0.8546) of all the single-feature ROCs investigated. The encouraging results seen in affective sensing based on pupil diameter monitoring were obtained in spite of intermittent illumination increases purposely introduced during the experiments. Therefore, these results confirmed the benefits of using the AIC implementation with the HITV adaptive algorithm to isolate the PAR and the potential of using PD monitoring to sense the evolving affective states of a computer user.