990 resultados para Diagnostic validation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study is to validate the applicability of the PolyVinyliDene Fluoride (PVDF) nasal sensor to assess the nasal airflow, in healthy subjects and patients with nasal obstruction and to correlate the results with the score of Visual Analogue Scale (VAS). Methods: PVDF nasal sensor and VAS measurements were carried out in 50 subjects (25-healthy subjects and 25 patients). The VAS score of nasal obstruction and peak-to-peak amplitude (Vp-p) of nasal cycle measured by PVDF nasal sensors were analyzed for right nostril (RN) and left nostril (LN) in both the groups. Spearman's rho correlation was calculated. The relationship between PVDF nasal sensor measurements and severity of nasal obstruction (VAS score) were assessed by ANOVA. Results: In healthy group, the measurement of nasal airflow by PVDF nasal sensor for RN and LN were found to be 51.14 +/- 5.87% and 48.85 +/- 5.87%, respectively. In patient group, PVDF nasal sensor indicated lesser nasal airflow in the blocked nostrils (RN: 23.33 +/- 10.54% and LN: 32.24 +/- 11.54%). Moderate correlation was observed in healthy group (r = 0.710, p < 0.001 for RN and r = 0.651, p < 0.001 for LN), and moderate to strong correlation in patient group (r = 0.751, p < 0.01 for RN and r = 0.885, p < 0.0001 for LN). Conclusion: PVDF nasal sensor method is a newly developed technique for measuring the nasal airflow. Moderate to strong correlation was observed between PVDF nasal sensor data and VAS scores for nasal obstruction. In our present study, PVDF nasal sensor technique successfully differentiated between healthy subjects and patients with nasal obstruction. Additionally, it can also assess severity of nasal obstruction in comparison with VAS. Thus, we propose that the PVDF nasal sensor technique could be used as a new diagnostic method to evaluate nasal obstruction in routine clinical practice. (C) 2015 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A competitive enzyme-linked immunosorbent assay (cELISA) was developed by using a whole-cell antigen from a marine Brucella sp. isolated from a harbor seal (Phoca vitulina). The assay was designed to screen sera from multiple marine mammal species for the presence of antibodies against marine-origin Brucella. Based on comparisons with culture-confirmed cases, specificity and sensitivity for cetacean samples tested were 73% and 100%, respectively. For pinniped samples, specificity and sensitivity values were 77% and 67%, respectively. Hawaiian monk seal (Monachus schauinslandi; n = 28) and bottlenose dolphin (Tursiops truncatus; n = 48) serum samples were tested, and the results were compared with several other assays designed to detect Brucella abortus antibodies. The comparison testing revealed the marine-origin cELISA to be more sensitive than the B. abortus tests by the detection of additional positive serum samples. The newly developed cELISA is an effective serologic method for detection of the presence of antibodies against marine-origin Brucella sp. in marine mammals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Emissions, fuel burn, and noise are the main drivers for innovative aircraft design. Embedded propulsion systems, such as for example used in hybrid-wing body aircraft, can offer fuel burn and noise reduction benefits but the impact of inlet flow distortion on the generation and propagation of turbomachinery noise has yet to be assessed. A novel approach is used to quantify the effects of non-uniform flow on the creation and propagation of multiple pure tone (MPT) noise. The ultimate goal is to conduct a parametric study of S-duct inlets to quantify the effects of inlet design parameters on the acoustic signature. The key challenge is that the effects of distortion transfer, noise source generation and propagation through the non-uniform flow field are inherently coupled such that a simultaneous computation of the aerodynamics and acoustics is required to capture the mechanisms at play. The technical approach is based on a body force description of the fan blade row that is able to capture the distortion transfer and the blade-to-blade flow variations that cause the MPT noise while reducing computational cost. A single, 3-D full-wheel CFD simulation, in which the Euler equations are solved to second-order spatial and temporal accuracy, simultaneously computes the MPT noise generation and its propagation in distorted inlet flow. A new method of producing the blade-to-blade variations in the body force field for MPT noise generation has been developed and validated. The numerical dissipation inherent to the solver is quantified and used to correct for non-physical attenuation in the far-field noise spectra. Source generation, acoustic propagation and acoustic energy transfer between modes is examined in detail. The new method is validated on NASA's Source Diagnostic Test fan and inlet, showing good agreement with experimental data for aerodynamic performance, acoustic source generation, and far-field noise spectra. The next steps involve the assessment of MPT noise in serpentine inlet ducts and the development of a reduced order formulation suitable for incorporation into NASA's ANOPP framework. © 2010 by Jeff Defoe, Alex Narkaj & Zoltan Spakovszky.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Loop-mediated isothermal amplification (LAMP) is an innovative technique that allows the rapid detection of target nucleic acid sequences under isothermal conditions without the need for complex instrumentation. The development, optimization, and clinical validation of a LAMP assay targeting the ctrA gene for the rapid detection of capsular Neisseria meningitidis were described. Highly specific detection of capsular N. meningitidis type strains and clinical isolates was demonstrated, with no cross-reactivity with other Neisseria spp. or with a comprehensive panel of other common human pathogens. The lower limit of detection was 6 ctrA gene copies detectable in 48 min, with positive reactions readily identifiable visually via a simple color change. Higher copy numbers could be detected in as little as 16 min. When applied to a total of 394 clinical specimens, the LAMP assay in comparison to a conventional TaqMan® based real-time polymerase chain reaction system demonstrated a sensitivity of 100% and a specificity of 98.9% with a ? coefficient of 0.942. The LAMP method represents a rapid, sensitive, and highly specific technique for the detection of N. meningitidis and has the potential to be used as a point-of-care molecular test and in resource-poor settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is a need to provide rapid, sensitive, and often high throughput detection of pathogens in diagnostic virology. Viral gastroenteritis is a serious health issue often leading to hospitalization in the young, the immunocompromised and the elderly. The common causes of viral gastroenteritis include rotavirus, norovirus (genogroups I and II), astrovirus, and group F adenoviruses (serotypes 40 and 41). This article describes the work-up of two internally controlled multiplex, probe-based PCR assays and reports on the clinical validation over a 3-year period, March 2007 to February 2010. Multiplex assays were developed using a combination of TaqMan™ and minor groove binder (MGB™) hydrolysis probes. The assays were validated using a panel of 137 specimens, previously positive via a nested gel-based assay. The assays had improved sensitivity for adenovirus, rotavirus, and norovirus (97.3% vs. 86.1%, 100% vs. 87.8%, and 95.1% vs. 79.5%, respectively) and also more specific for targets adenovirus, rotavirus, and norovirus (99% vs. 95.2%, 100% vs. 93.6%, and 97.9% vs. 92.3%, respectively). For the specimens tested, both assays had equal sensitivity and specificity for astrovirus (100%). Overall the probe-based assays detected 16 more positive specimens than the nested gel-based assay. Post-introduction to the routine diagnostic service, a total of 9,846 specimens were processed with multiplex 1 and 2 (7,053 pediatric, 2,793 adult) over the 3-year study period. This clinically validated, probe-based multiplex testing algorithm allows highly sensitive and timely diagnosis of the four most prominent causes of viral gastroenteritis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Loop-mediated isothermal amplification (LAMP) is an innovative technique that allows the rapid detection of target nucleic acid sequences under isothermal conditions without the need for complex instrumentation. The development, optimization, and clinical validation of a LAMP assay targeting the ctrA gene for the rapid detection of capsular Neisseria meningitidis were described. Highly specific detection of capsular N. meningitidis type strains and clinical isolates was demonstrated, with no cross-reactivity with other Neisseria spp. or with a comprehensive panel of other common human pathogens. The lower limit of detection was 6 ctrA gene copies detectable in 48 min, with positive reactions readily identifiable visually via a simple color change. Higher copy numbers could be detected in as little as 16 min. When applied to a total of 394 clinical specimens, the LAMP assay in comparison to a conventional TaqMan® based real-time polymerase chain reaction system demonstrated a sensitivity of 100% and a specificity of 98.9% with a ? coefficient of 0.942. The LAMP method represents a rapid, sensitive, and highly specific technique for the detection of N. meningitidis and has the potential to be used as a point-of-care molecular test and in resource-poor settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Early descriptive work and controlled family and adoption studies support the hypothesis that a range of personality and nonschizophrenic psychotic disorders aggregate in families of schizophrenic probands. Can we validate, using molecular polygene scores from genome-wide association studies (GWAS), this schizophrenia spectrum? Methods: The predictive value of polygenic findings reported by the Psychiatric GWAS Consortium (PGC) was applied to 4 groups of relatives from the Irish Study of High-Density Schizophrenia Families (ISHDSF; N = s) differing on their assignment within the schizophrenia spectrum. Genome-wide single nucleotide polymorphism data for affected and unaffected relatives were used to construct per-individual polygene risk scores based on the PGC stage-I results. We compared mean polygene scores in the ISHDSF with mean scores in ethnically matched population controls (N = 929). Results: The schizophrenia polygene score differed significantly across diagnostic categories and was highest in those with narrow schizophrenia spectrum, lowest in those with no psychiatric illness, and in-between in those classified in the intermediate, broad, and very broad schizophrenia spectrum. Relatives of all of these groups of affected subjects, including those with no diagnosis, had schizophrenia polygene scores significantly higher than the control sample. Conclusions: In the relatives of high-density families, the observed pattern of enrichment of molecular indices of schizophrenia risk suggests an underlying, continuous liability distribution and validates, using aggregate common risk alleles, a genetic basis for the schizophrenia spectrum disorders. In addition, as predicted by genetic theory, nonpsychotic members of multiply-affected schizophrenia families are significantly enriched for replicated, polygenic risk variants compared with the general population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Excessive use of empirical antibiotics is common in critically ill patients. Rapid biomarker-based exclusion of infection may improve antibiotic stewardship in ventilator-acquired pneumonia (VAP). However, successful validation of the usefulness of potential markers in this setting is exceptionally rare.

Objectives: We sought to validate the capacity for specific host inflammatory mediators to exclude pneumonia in patients with suspected VAP. 

Methods: A prospective, multicentre, validation study of patients with suspected VAP was conducted in 12 intensive care units. VAP was confirmed following bronchoscopy by culture of a potential pathogen in bronchoalveolar lavage fluid (BALF) at >104 colony forming units per millilitre (cfu/mL). Interleukin-1 beta (IL-1β), IL-8, matrix metalloproteinase-8 (MMP-8), MMP-9 and human neutrophil elastase (HNE) were quantified in BALF. Diagnostic utility was determined for biomarkers individually and in combination. 

Results: Paired BALF culture and biomarker results were available for 150 patients. 53 patients (35%) had VAP and 97 (65%) patients formed the non-VAP group. All biomarkers were significantly higher in the VAP group (p<0.001). The area under the receiver operator characteristic curve for IL-1β was 0.81; IL-8, 0.74; MMP-8, 0.76; MMP-9, 0.79 and HNE, 0.78. A combination of IL-1β and IL-8, at the optimal cut-point, excluded VAP with a sensitivity of 100%, a specificity of 44.3% and a post-test probability of 0% (95% CI 0% to 9.2%). 

Conclusions: Low BALF IL-1β in combination with IL-8 confidently excludes VAP and could form a rapid biomarker-based rule-out test, with the potential to improve antibiotic stewardship.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the increasing availability of digital slide viewing, and numerous advantages associated with its application, a lack of quality validation studies is amongst the reasons for poor uptake in routine practice. This study evaluated primary digital pathology reporting in the setting of routine subspecialist gastrointestinal pathology, commonplace in most tissue pathology laboratories and representing one of the highest volume specialties in most laboratories. Individual digital and glass slide diagnoses were compared amongst three pathologists reporting in a gastrointestinal subspecialty team, in a prospective series of 100 consecutive diagnostic cases from routine practice in a large teaching hospital laboratory. The study included a washout period of at least 6 months. Discordant diagnoses were classified, and the study evaluated against recent College of American Pathologists (CAP) recommendations for evaluating digital pathology systems for diagnostic use. The study design met all 12 of the CAP recommendations. The 100 study cases generated 300 pairs of diagnoses, comprising 100 glass slide diagnoses and 100 digital diagnoses from each of the three study pathologists. 286 of 300 pairs of diagnoses were concordant, representing intraobserver concordance of 95.3 %, broadly comparable to rates previously published in this field. In ten of the 14 discordant pairs, the glass slide diagnosis was favoured; in four cases, the digital diagnosis was favoured, but importantly, the 14 discordant intraobserver diagnoses were considered to be of minor clinical significance. Interobserver, or viewing modality independent, concordance was found in 94 of the total of 100 study cases, providing a comparable baseline discordance rate expected in any second viewing of pathology material. These overall results support the safe use of digital pathology in primary diagnostic reporting in this setting

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immunohistochemistry (IHC) is a widely available and highly utilised tool in diagnostic histopathology and is used to guide treatment options as well as provide prognostic information. IHC is subjected to qualitative and subjective assessment, which has been criticised for a lack of stringency, while PCR-based molecular diagnostic validations by comparison are regarded as very rigorous. It is essential that IHC tests are validated through evidence-based procedures. With the move to ISO15189 (2012), not just of the accuracy, specificity and reproducibility of each test need to be determined and managed, but also the degree of uncertainty and the delivery of such tests. The recent update to ISO 15189 (2012) states that it is appropriate to consider the potential uncertainty of measurement of the value obtained in the laboratory and how that may impact on prognostic or predictive thresholds. In order to highlight the problems surrounding IHC validity, we reviewed the measurement of Ki67and p53 in the literature. Both of these biomarkers have been incorporated into clinical care by pathology laboratories worldwide. The variation seen appears excessive even when measuring centrally stained slides from the same cases. We therefore propose in this paper to establish the basis on which IHC laboratories can bring the same level of robust validation seen in the molecular pathology laboratories and the principles applied to all routine IHC tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Practice guidelines for examining febrile patients presenting upon returning from the tropics were developed to assist primary care physicians in decision making. Because of the low level of evidence available in this field, there was a need to validate them and assess their feasibility in the context they have been designed for. OBJECTIVES: The objectives of the study were to (1) evaluate physicians' adherence to recommendations; (2) investigate reasons for non-adherence; and (3) ensure good clinical outcome of patients, the ultimate goal being to improve the quality of the guidelines, in particular to tailor them for the needs of the target audience and population. METHODS: Physicians consulting the guidelines on the Internet (www.fevertravel.ch) were invited to participate in the study. Navigation through the decision chart was automatically recorded, including diagnostic tests performed, initial and final diagnoses, and clinical outcomes. The reasons for non-adherence were investigated and qualitative feedback was collected. RESULTS: A total of 539 physician/patient pairs were included in this study. Full adherence to guidelines was observed in 29% of the cases. Figure-specific adherence rate was 54.8%. The main reasons for non-adherence were as follows: no repetition of malaria tests (111/352) and no presumptive antibiotic treatment for febrile diarrhea (64/153) or abdominal pain without leukocytosis (46/101). Overall, 20% of diversions from guidelines were considered reasonable because there was an alternative presumptive diagnosis or the symptoms were mild, which means that the corrected adherence rate per case was 40.6% and corrected adherence per figure was 61.7%. No death was recorded and all complications could be attributed to the underlying illness rather than to adherence to guidelines. CONCLUSIONS: These guidelines proved to be feasible, useful, and leading to good clinical outcomes. Almost one third of physicians strictly adhered to the guidelines. Other physicians used the guidelines not to forget specific diagnoses but finally diverged from the proposed attitudes. These diversions should be scrutinized for further refinement of the guidelines to better fit to physician and patient needs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carbapenemases should be accurately and rapidly detected, given their possible epidemiological spread and their impact on treatment options. Here, we developed a simple, easy and rapid matrix-assisted laser desorption ionization-time of flight (MALDI-TOF)-based assay to detect carbapenemases and compared this innovative test with four other diagnostic approaches on 47 clinical isolates. Tandem mass spectrometry (MS-MS) was also used to determine accurately the amount of antibiotic present in the supernatant after 1 h of incubation and both MALDI-TOF and MS-MS approaches exhibited a 100% sensitivity and a 100% specificity. By comparison, molecular genetic techniques (Check-MDR Carba PCR and Check-MDR CT103 microarray) showed a 90.5% sensitivity and a 100% specificity, as two strains of Aeromonas were not detected because their chromosomal carbapenemase is not targeted by probes used in both kits. Altogether, this innovative MALDI-TOF-based approach that uses a stable 10-μg disk of ertapenem was highly efficient in detecting carbapenemase, with a sensitivity higher than that of PCR and microarray.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les interventions proactives ou comportementales en classe sont reconnues empiriquement pour leur efficacité à améliorer le comportement ou le rendement scolaire des enfants ayant un TDAH (DuPaul & Eckert, 1997; Hoza, Kaiser, & Hurt, 2008; Pelham & Fabiano, 2008; Zentall, 2005). Or, l’écart entre les interventions probantes et celles retrouvées dans le milieu général de l’éducation souligne l’importance de répliquer les résultats d’études obtenus dans un environnement contrôlé dans un format de livraison réaliste. L’objectif principal de cette thèse est d’élaborer et d’évaluer un programme de consultation individuelle (PCI) fondé sur une démarche de résolution de problème et d’évaluation fonctionnelle, pour soutenir les enseignants du primaire dans la planification et la mise en œuvre cohérente des interventions privilégiées pour aider les enfants ayant un TDAH. D’abord, une recension des principales modalités d’intervention auprès des enfants ayant un TDAH est effectuée afin d’identifier les interventions à inclure lors du développement du programme. Par la suite, des solutions favorisant le transfert des interventions probantes à la classe ordinaire sont détaillées par la proposition du PCI ayant lieu entre un intervenant psychosocial et l’enseignant. Enfin, l’évaluation du PCI auprès de trente-sept paires enfant-enseignant est présentée. Tous les enfants ont un diagnostic de TDAH et prennent une médication (M). Les parents de certains enfants ont participé à un programme d’entraînement aux habiletés parentales (PEHP). L’échantillon final est: M (n = 4), M et PEHP (n = 11), M et PCI (n = 11), M, PEHP et PCI (n = 11). Les résultats confirment l’efficacité du PCI au-delà de M et M + PEHP pour éviter une aggravation des comportements inappropriés et améliorer le rendement scolaire des enfants ayant un TDAH. Par ailleurs, une augmentation de l’utilisation des stratégies efficaces par l’enseignant est observable lorsqu’il a à la fois participé au PCI et reçu une formation continue sur le TDAH en cours d’emploi. Les implications cliniques de l’intervention pour l’enfant ayant un TDAH et son enseignant de classe ordinaire sont discutées.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le biais de confusion est un défi majeur des études observationnelles, surtout s'ils sont induits par des caractéristiques difficiles, voire impossibles, à mesurer dans les banques de données administratives de soins de santé. Un des biais de confusion souvent présents dans les études pharmacoépidémiologiques est la prescription sélective (en anglais « prescription channeling »), qui se manifeste lorsque le choix du traitement dépend de l'état de santé du patient et/ou de son expérience antérieure avec diverses options thérapeutiques. Parmi les méthodes de contrôle de ce biais, on retrouve le score de comorbidité, qui caractérise l'état de santé d'un patient à partir de médicaments délivrés ou de diagnostics médicaux rapportés dans les données de facturations des médecins. La performance des scores de comorbidité fait cependant l'objet de controverses car elle semble varier de façon importante selon la population d'intérêt. Les objectifs de cette thèse étaient de développer, valider, et comparer les performances de deux scores de comorbidité (un qui prédit le décès et l’autre qui prédit l’institutionnalisation), développés à partir des banques de services pharmaceutiques de la Régie de l'assurance-maladie du Québec (RAMQ) pour leur utilisation dans la population âgée. Cette thèse vise également à déterminer si l'inclusion de caractéristiques non rapportées ou peu valides dans les banques de données administratives (caractéristiques socio-démographiques, troubles mentaux ou du sommeil), améliore la performance des scores de comorbidité dans la population âgée. Une étude cas-témoins intra-cohorte fut réalisée. La cohorte source consistait en un échantillon aléatoire de 87 389 personnes âgées vivant à domicile, répartie en une cohorte de développement (n=61 172; 70%) et une cohorte de validation (n=26 217; 30%). Les données ont été obtenues à partir des banques de données de la RAMQ. Pour être inclus dans l’étude, les sujets devaient être âgés de 66 ans et plus, et être membres du régime public d'assurance-médicaments du Québec entre le 1er janvier 2000 et le 31 décembre 2009. Les scores ont été développés à partir de la méthode du Framingham Heart Study, et leur performance évaluée par la c-statistique et l’aire sous les courbes « Receiver Operating Curves ». Pour le dernier objectif qui est de documenter l’impact de l’ajout de variables non-mesurées ou peu valides dans les banques de données au score de comorbidité développé, une étude de cohorte prospective (2005-2008) a été réalisée. La population à l'étude, de même que les données, sont issues de l'Étude sur la Santé des Aînés (n=1 494). Les variables d'intérêt incluaient statut marital, soutien social, présence de troubles de santé mentale ainsi que troubles du sommeil. Tel que décrit dans l'article 1, le Geriatric Comorbidity Score (GCS) basé sur le décès, a été développé et a présenté une bonne performance (c-statistique=0.75; IC95% 0.73-0.78). Cette performance s'est avérée supérieure à celle du Chronic Disease Score (CDS) lorsqu'appliqué dans la population à l'étude (c-statistique du CDS : 0.47; IC 95%: 0.45-0.49). Une revue de littérature exhaustive a montré que les facteurs associés au décès étaient très différents de ceux associés à l’institutionnalisation, justifiant ainsi le développement d'un score spécifique pour prédire le risque d'institutionnalisation. La performance de ce dernier s'est avérée non statistiquement différente de celle du score de décès (c-statistique institutionnalisation : 0.79 IC95% 0.77-0.81). L'inclusion de variables non rapportées dans les banques de données administratives n'a amélioré que de 11% la performance du score de décès; le statut marital et le soutien social ayant le plus contribué à l'amélioration observée. En conclusion, de cette thèse, sont issues trois contributions majeures. D'une part, il a été démontré que la performance des scores de comorbidité basés sur le décès dépend de la population cible, d'où l'intérêt du Geriatric Comorbidity Score, qui fut développé pour la population âgée vivant à domicile. D'autre part, les médicaments associés au risque d'institutionnalisation diffèrent de ceux associés au risque de décès dans la population âgé, justifiant ainsi le développement de deux scores distincts. Cependant, les performances des deux scores sont semblables. Enfin, les résultats indiquent que, dans la population âgée, l'absence de certaines caractéristiques ne compromet pas de façon importante la performance des scores de comorbidité déterminés à partir de banques de données d'ordonnances. Par conséquent, les scores de comorbidité demeurent un outil de recherche important pour les études observationnelles.