987 resultados para Diagnostic techniques, respiratory system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The discovery of an ever-expanding plethora of coding and non-coding RNAs with nodal and causal roles in the regulation of lung physiology and disease is reinvigorating interest in the clinical utility of the oligonucleotide therapeutic class. This is strongly supported through recent advances in nucleic acids chemistry, synthetic oligonucleotide delivery and viral gene therapy that have succeeded in bringing to market at least three nucleic acid-based drugs. As a consequence, multiple new candidates such as RNA interference modulators, antisense, and splice switching compounds are now progressing through clinical evaluation. Here, manipulation of RNA for the treatment of lung disease is explored, with emphasis on robust pharmacological evidence aligned to the five pillars of drug development: exposure to the appropriate tissue, binding to the desired molecular target, evidence of the expected mode of action, activity in the relevant patient population and commercially viable value proposition.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Endoscopic percutaneous gastrostomy is a safe technique although with potential complications before which the clinician has to be on alert in order to early detect them even after a long period of normal functioning. Most of them represent minor problems. Gastrocolocutaneous fistula is a rare but severe complication favored by some risk factors such as previous post-surgical adherences, deformities of the spine, or excessive gastric inflation at the time of performing the technique. We present the case of a patient with PEG with this complication that occurred after the first tube replacement. Our goal was in two senses: on the one hand, to analyze the preventive aspects and basic guidelines for a safe PEG placement to minimize the risks; on the other hand, to alert on the possible presence of this entity to prevent a progressive nutritional impairment. This complication ought to be included in the differential diagnosis of the diarrhea syndrome in the patient carrying a PEG. The diagnostic techniques of choice are radiologic tests such as CT scan and contrast media administration through the tube. Surgical therapy should be reserved to patients with acute peritonitis in order to perform a new gastrostomy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Obscure gastrointestinal bleeding is still a clinical challenge for gastroenterologists. The recent development of novel technologies for the diagnosis and treatment of different bleeding causes has allowed a better management of patients, but it also determines the need of a deeper comprehension of pathophysiology and the analysis of local expertise in order to develop a rational management algorithm. Obscure gastrointestinal bleeding can be divided in occult, when a positive occult blood fecal test is the main manifestation, and overt, when external sings of bleeding are visible. In this paper we are going to focus on overt gastrointestinal bleeding, describing the physiopathology of the most usual causes, analyzing the diagnostic procedures available, from the most classical to the novel ones, and establishing a standard algorithm which can be adapted depending on the local expertise or availability. Finally, we will review the main therapeutic options for this complex and not so uncommon clinical problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CD is a chronic inflammatory disorder associated to mucosal and transmural inflammation of the bowel wall. It is well known that CD can affect the entire gastrointestinal. Therefore, ileocolonoscopy and biopsies of the terminal ileum as well as of each colonic segment to look for microscopic evidence of CD are the first-line procedures to establish the diagnosis. However, it has been observed that up to 30% of the patients have only small bowel involvement. Evaluation of the small bowel has been made with radiological procedures, barium radiography, and abdominal computed tomography or by ileocolonoscopy or enteroscopy, but they have many recognized limitations. CE is undoubtedly a very useful diagnostic tool proposed to observe small-bowel lesions undetectable by conventional endoscopy or radiologic studies. We review different studies that have been published reporting the use of CE in suspected and evaluation of the extension or the recurrence in CD and also its use in pediatric population and its complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CD is a chronic inflammatory disorder associated to mucosal and transmural inflammation of the bowel wall. It is well known that CD can affect the entire gastrointestinal. Therefore, ileocolonoscopy and biopsies of the terminal ileum as well as of each colonic segment to look for microscopic evidence of CD are the first-line procedures to establish the diagnosis. However, it has been observed that up to 30% of the patients have only small bowel involvement. Evaluation of the small bowel has been made with radiological procedures, barium radiography, and abdominal computed tomography or by ileocolonoscopy or enteroscopy, but they have many recognized limitations. CE is undoubtedly a very useful diagnostic tool proposed to observe small-bowel lesions undetectable by conventional endoscopy or radiologic studies. We review different studies that have been published reporting the use of CE in suspected and evaluation of the extension or the recurrence in CD and also its use in pediatric population and its complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Drugs for inhalation are the cornerstone of therapy in obstructive lung disease. We have observed that up to 75 % of patients do not perform a correct inhalation technique. The inability of patients to correctly use their inhaler device may be a direct consequence of insufficient or poor inhaler technique instruction. The objective of this study is to test the efficacy of two educational interventions to improve the inhalation techniques in patients with Chronic Obstructive Pulmonary Disease (COPD). METHODS This study uses both a multicenter patients´ preference trial and a comprehensive cohort design with 495 COPD-diagnosed patients selected by a non-probabilistic method of sampling from seven Primary Care Centers. The participants will be divided into two groups and five arms. The two groups are: 1) the patients´ preference group with two arms and 2) the randomized group with three arms. In the preference group, the two arms correspond to the two educational interventions (Intervention A and Intervention B) designed for this study. In the randomized group the three arms comprise: intervention A, intervention B and a control arm. Intervention A is written information (a leaflet describing the correct inhalation techniques). Intervention B is written information about inhalation techniques plus training by an instructor. Every patient in each group will be visited six times during the year of the study at health care center. DISCUSSION Our hypothesis is that the application of two educational interventions in patients with COPD who are treated with inhaled therapy will increase the number of patients who perform a correct inhalation technique by at least 25 %. We will evaluate the effectiveness of these interventions on patient inhalation technique improvement, considering that it will be adequate and feasible within the context of clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the first evaluation of a novel molecular assay, the Speed-oligo Direct Mycobacterium tuberculosis (SO-DMT) assay, which is based on PCR combined with a dipstick for the detection of mycobacteria and the specific identification of M. tuberculosis complex (MTC) in respiratory specimens. A blind evaluation was carried out in two stages: first, under experimental conditions on convenience samples comprising 20 negative specimens, 44 smear- and culture-positive respiratory specimens, and 11 sputa inoculated with various mycobacterium-related organisms; and second, in the routine workflow of 566 fresh respiratory specimens (4.9% acid-fast bacillus [AFB] smear positives, 7.6% MTC positives, and 1.8% nontuberculous mycobacteria [NTM] culture positives) from two Mycobacterium laboratories. SO-DMT assay showed no reactivity in any of the mycobacterium-free specimens or in those with mycobacterium-related organisms. Compared to culture, the sensitivity in the selected smear-positive specimens was 0.91 (0.92 for MTC and 0.90 for NTM), and there was no molecular detection of NTM in a tuberculosis case or vice versa. With respect to culture and clinical data, the sensitivity, specificity, and positive and negative predictive values for the SO-DMT system in routine specimens were 0.76 (0.93 in smear positives [1.0 for MTC and 0.5 for NTM] and 0.56 in smear negatives [0.68 for MTC and 0.16 for NTM]), 0.99, 0.85 (1.00 in smear positives and 0.68 in smear negatives), and 0.97, respectively. Molecular misidentification of NTM cases occurred when testing 2 gastric aspirates from two children with clinically but not microbiologically confirmed lung tuberculosis. The SO-DMT assay appears to be a fast and easy alternative for detecting mycobacteria and differentiating MTC from NTM in smear-positive respiratory specimens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Respiration is a complex activity. If the relationship between all neurological and skeletomuscular interactions was perfectly understood, an accurate dynamic model of the respiratory system could be developed and the interaction between different inputs and outputs could be investigated in a straightforward fashion. Unfortunately, this is not the case and does not appear to be viable at this time. In addition, the provision of appropriate sensor signals for such a model would be a considerable invasive task. Useful quantitative information with respect to respiratory performance can be gained from non-invasive monitoring of chest and abdomen motion. Currently available devices are not well suited in application for spirometric measurement for ambulatory monitoring. A sensor matrix measurement technique is investigated to identify suitable sensing elements with which to base an upper body surface measurement device that monitors respiration. This thesis is divided into two main areas of investigation; model based and geometrical based surface plethysmography. In the first instance, chapter 2 deals with an array of tactile sensors that are used as progression of existing and previously investigated volumetric measurement schemes based on models of respiration. Chapter 3 details a non-model based geometrical approach to surface (and hence volumetric) profile measurement. Later sections of the thesis concentrate upon the development of a functioning prototype sensor array. To broaden the application area the study has been conducted as it would be fore a generically configured sensor array. In experimental form the system performance on group estimation compares favourably with existing system on volumetric performance. In addition provides continuous transient measurement of respiratory motion within an acceptable accuracy using approximately 20 sensing elements. Because of the potential size and complexity of the system it is possible to deploy it as a fully mobile ambulatory monitoring device, which may be used outside of the laboratory. It provides a means by which to isolate coupled physiological functions and thus allows individual contributions to be analysed separately. Thus facilitating greater understanding of respiratory physiology and diagnostic capabilities. The outcome of the study is the basis for a three-dimensional surface contour sensing system that is suitable for respiratory function monitoring and has the prospect with future development to be incorporated into a garment based clinical tool.