981 resultados para Detectability with ELISA


Relevância:

40.00% 40.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Human schistosomiasis, caused by Schistosoma mansoni, is highly prevalent in Brazil and usually diagnosed by time consuming stool analysis. Serological tests are of limited use in this disease, mainly for epidemiological studies, showing no discrimination between previous contact with the parasite and active infections. In the present study, we standardized and compared a Dot-ELISA for IgM and IgG antibodies against S. mansoni antigens from eggs and worms with a routine IgG and IgM immunofluorescence assay using similar antigens, in the study of sera from 27 patients who had quantified egg stool excretion. The positivity obtained for IgG Dot-ELISA was 96.3% and 88.9% for IgM Dot-ELISA with worm antigen and 92.6% and 90.9% with egg antigen. The IFI presented similar positivities using worm antigen, 92.6% (IgG) and 96.3% (IgM),and lower results with egg antigen, 77.8% (IgG and IgM). The patients studied were divided into two groups according to their egg excretion, with greater positivity of serological tests in higher egg excreters. When comparing the quantitative egg excretion and the serological titers of the patients, we detected a correlation only with IgM Dot-ELISA, with r=0.552 (p=0.0127). These data show that Dot-ELISA can be used for the detection of specific antibodies against S. mansoni in sera from suspected patients or in epidemiological studies and, with further purification of egg antigen and larger samples, IgM Dot-ELISA could be a possible tool for rough estimates of parasite burden in epidemiological studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Twenty-seven mycologically proven cases of paracoccidioidomycosis (PCM) were treated with itraconazole (100-200 mg/day in month 1 and 100 mg/day until month 6-8) and evaluated clinically and serologically, up to 3.5 years post-therapy, using Dot-blot and ELISA for measuring the titers of IgG, IgA and IgM anti-P. brasiliensis antibodies and Western-blot for determining IgG, IgA and IgM antibodies against the antigen components of the fungus. Before treatment, 81.5% (Dot-blot) and 84% (ELISA) of the patients presented elevated IgG anti-P. brasiliensis antibody titers which dropped slightly with treatment. On the other hand, the percentages of pre-treatment high-titered sera for IgA and IgM anti-P.brasiliensis were lower (5l.9% and 5l.8%: Dot-blot; 16.5 and 36%: ELISA, respectively) but the titers tended to become negative more frequently with treatment. Prior to treatment, the percentages of positivity for IgG, IgA and IgM anti-P.brasiliensis antibodies in Western-blot were 96%, 20.8% and 41.6%, respectively. Antigens with molecular weights varying from 16-78 kDa, from 21-76 kDa and from 27-78 kDa were reactive for IgG, IgA and IgM antibodies, respectively. The most frequently reactive antigenic components had molecular weights of 27, 33 and 43 kDa for IgG, and 70 for IgA and IgM antibodies. During the period of study, the patients responded well to treatment. The present data confirm the diversity and complexity of the humoral response in PCM, and the importance of utilizing different serological tests to detect IgG, IgA and IgM anti-P. brasiliensis antibodies

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An indirect ELISA for determination of post-vaccination rabies antibody was applied. Purified rabies virus was used as antigen to coat plates, and staphylococcal protein A linked with horseradish peroxidase was used for detecting IgG antibody in human sera. Sera from humans, vaccinated with cell-culture vaccine or suckling-mouse-brain vaccine, were examined. ELISA results were compared to those obtained from the virus neutralization test. The mean and standard deviation of OD were determined for 126 negative sera (pre-vaccination) and for 73 sera from vaccinated persons showing antibody titers lower than 0.5 IU/ml. Results were defined as ELISA -positive, -negative or -doubtful. Establishment of a doubtful region reduced the number of sera otherwise classified as positive (false-positive sera). In this way, the sensitivity, specificity and agreement values were respectively 87.5%, 92.4% and 88.5%. No significant differences were observed in these values when the group vaccinated with cell-culture vaccine and the group vaccinated with suckling-mouse-brain vaccine were compared. It was shown that much of the disagreement between the values obtained by neutralization test and ELISA occurred in sera obtained at the beginning of the immunization process, and was probably due to the presence of IgM in the serum samples, detected only by the former test. This ELISA method can be used as a screening test in rabies laboratories regardless of the kind of vaccine used for immunization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Sera from 88 patients from Santa Catarina and São Paulo states of Brazil, with epileptic seizures who underwent cerebral computed tomography (CT) were analyzed for the detection of antibodies to T. solium cysticercus by ELISA and Immunoblot (IB) with the following antigens: Taenia solium cysticercus total saline (Tso), Taenia crassiceps cysticercus vesicular fluid (Tcra-vf) and T. crassiceps cysticercus glycoproteins (Tcra-gp). ELISA carried out with Tso, Tcra-vf and Tcra-gp antigens showed 95%, 90% and 80% sensitivities, respectively, and 68%, 85% and 93% specificities, respectively. In the epileptic patients group, ELISA positivity was 30%, 51% and 35% with Tso, Tcra-vf and Tcra-gp antigens respectively. Considering the IB as the confirmatory test, the positivity was 16% (14/88) in the epileptic patients total group and 22% (12/54) in the epileptic patients with positive CT and signals of cysticercosis. We found a significant statistical correlation among ELISA or IB results and the phase of the disease when any antigens were used (p < 0.05). We emphasize the need to introduce in the laboratory routine the search for neurocysticercosis (NC) in patients presenting with epileptic seizures because of the high risk of acquiring NC in our region and its potential cause of epilepsy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main serological marker for the diagnosis of recent toxoplasmosis is the specific IgM antibody, along with IgG antibodies of low avidity. However, in some patients these antibodies may persist long after the acute/recent phase, contributing to misdiagnosis in suspected cases of toxoplasmosis. In the present study, the diagnostic efficiency of ELISA was evaluated, with the use of peptides derived from T. gondii ESA antigens, named SAG-1, GRA-1 and GRA-7. In the assay referred to, we studied each of these peptides individually, as well as in four different combinations, as Multiple Antigen Peptides (MAP), aiming to establish a reliable profile for the acute/recent toxoplasmosis with only one patient serum sample. The diagnostic performance of the assay using MAP1, with the combination of SAG-1, GRA-1 and GRA-7 peptides, demonstrated better discrimination of the acute/recent phase from non acute/recent phase of toxoplasmosis. Our results show that IgM antibodies to MAP1 may be useful as a serological marker, enhancing the diagnostic efficiency of the assay for acute/recent phase of toxoplasmosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work compared the time at which negative seroconversion was detected by conventional serology (CS) and by the ELISA-F29 test on a cohort of chronic chagasic patients treated with nifurtimox or benznidazole. A retrospective study was performed using preserved serum from 66 asymptomatic chagasic adults under clinical supervision, and bi-annual serological examinations over a mean follow-up of 23 years. Twenty nine patients received trypanocide treatment and 37 remained untreated. The ELISA-F29 test used a recombinant antigen which was obtained by expressing the Trypanosoma cruzi flagellar calcium-binding protein gene in Escherichia coli. Among the untreated patients, 36 maintained CS titers. One patient showed a doubtful serology in some check-ups. ELISA-F29 showed constant reactivity in 35 out of 37 patients and was negative for the patient with fluctuating CS. The treated patients were divided into three groups according to the CS titers: in 13 they became negative; in 12 they decreased and in four they remained unchanged. ELISA-F29 was negative for the first two groups. The time at which negativization was detected was significantly lower for the ELISA-F29 test than for CS, 14.5 ± 5.7 and 22 ± 4.9 years respectively. Negative seroconversion was observed in treated patients only. The results obtained confirm that the ELISA-F29 test is useful as an early indicator of negative seroconversion in treated chronic patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: The laboratory diagnosis of schistosomiasis is based mainly on the detection of parasite eggs in stool samples through the Kato-Katz (KK) technique, reading one slide by test. However, a widely known limitation of parasitological methods is reduced sensitivity, particularly in low endemic areas. METHODS: To increase sensitivity, we conducted further slide readings from the same stool sample using the parasitological method associated with a serological test. We used the KK method (three slides) and the IgG anti-Schistosoma mansoni-enzyme-linked immunosorbent assay (ELISA) technique to diagnose schistosomiasis in low endemic areas in the Brazilian State of Ceará. Fecal samples and sera from 250 individuals were analyzed. RESULTS: Sixteen percent and 47.2% of samples were positive in parasitological tests and serological tests, respectively. Parasitological methods showed that 32 (80%) individuals tested positive on the first slide, 6 (15%) on the second slide, and 2 (5%) on the third. The performance of the ELISA test in the diagnosis, using the KK method as diagnostic reference, showed a negative predictive value of 100%, with specificity and positive predictive values of 62.8% and 33.9%, respectively. CONCLUSIONS: In this study, the increase from one to three slides analyzed per sample using the KK technique was shown to be a useful procedure for increasing the diagnostic sensitivity of this technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Toxoplasma gondii causes posterior uveitis and the specific diagnosis is based on clinical criteria. The presence of anti-T. gondii secretory IgA (sIgA) antibodies in patients' tears has been reported and an association was found between ocular toxoplasmosis and the anti-T. gondii sIgA isotype in Brazilian patients. The purpose of this study was to provide an objective validation of the published ELISA test for determining the presence of anti-T. gondii sIgA in the tears of individuals with ocular toxoplasmosis. Tears from 156 patients with active posterior uveitis were analysed; 82 of them presented characteristics of ocular toxoplasmosis (standard lesion) and 74 patients presented uveitis due to other aetiologies. Cases of active posterior uveitis were considered standard when a new inflammatory focus satellite to old retinochoroidal scars was observed. The determination of anti-T. gondii sIgA was made using an ELISA test with crude tachyzoite antigenic extracts. Tears were collected without previous stimulation. Detection of sIgA showed 65.9% sensitivity (95% CI = 54.5-74.4), 71.6% specificity (95% CI = 59.8-81.2), a positive predictive value of 72% (95% CI = 60.3-81.5) and a negative predictive value of 65.4% (95% CI = 54.0-75.4). sIgA reactivity was higher in the tears of patients with active posterior uveitis due to T. gondii (p < 0.05). The test is useful for differentiating active posterior uveitis due to toxoplasmosis from uveitis caused by other diseases.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The levels of total of IgG, IgG1, IgG2, IgG3 and IgG4 were evaluated in 54 patients with chronic paracoccidioidomycosis (PCM) before, during and after treatment using an enzyme-linked immunosorbent assay with Mexo and recombinant Pb27 (rPb27) as the antigens. Mexo was effective in distinguishing PCM patients from individuals in the negative control group (NC) based on total IgG and rPb27 performed worse than Mexo when these two groups were compared. IgG1, IgG2, IgG3 and IgG4 could not be used to clearly distinguish PCM patients from those in the NC group using either antigen. There was no clear relationship between antibody levels and the period of treatment. The majority of patients presented with decreased antibody levels during treatment, with no statistically significant differences among the different periods of treatment. Only IgG4 presented a negative correlation between its levels and clinical improvement during treatment. In total, 65% of untreated PCM patients showed reactivity against IgG4 when the Mexo antigen was used and this reactivity decreased over the course of treatment. There was a tendency towards decreasing antibody levels during treatment, but these antibody levels did not necessarily clear after the treatment was stopped. Mexo was useful for PCM diagnosis using total IgG; however, more studies are necessary before this antigen can be used in measuring the levels of total IgG and its subclasses for monitoring patients during treatment.