982 resultados para Design standards
Resumo:
Statistics has become an indispensable tool in biomedical research. Thanks, in particular, to computer science, the researcher has easy access to elementary "classical" procedures. These are often of a "confirmatory" nature: their aim is to test hypotheses (for example the efficacy of a treatment) prior to experimentation. However, doctors often use them in situations more complex than foreseen, to discover interesting data structures and formulate hypotheses. This inverse process may lead to misuse which increases the number of "statistically proven" results in medical publications. The help of a professional statistician thus becomes necessary. Moreover, good, simple "exploratory" techniques are now available. In addition, medical data contain quite a high percentage of outliers (data that deviate from the majority). With classical methods it is often very difficult (even for a statistician!) to detect them and the reliability of results becomes questionable. New, reliable ("robust") procedures have been the subject of research for the past two decades. Their practical introduction is one of the activities of the Statistics and Data Processing Department of the University of Social and Preventive Medicine, Lausanne.
Resumo:
Hihnakuljettimia käytetään muun muassa voimalaitos- ja sellutehdasympäristöissä kuljettamaan kiinteää polttoainetta tai haketta pitkiä matkoja. Pitkät hihnakuljettimet asennetaan yleensä teräsristikoista rakennettujen kuljetinsiltojen sisään. Kuljetinsilta toimii siis hihnakuljettimen ja hoitokäytävän runkona sekä suojaa kuljetinta ja kuljetettavaa materiaalia säältä. Tässä diplomityössä on laadittu mitoitustyökalu, jolla voidaan nopeasti mitoittaa ristikkorakenteisen hihnakuljetinsillan sauvat sekä määrittää rakenteen massa. Laskentaohjelma on toteutettu Microsoft Excel -taulukkolaskentana. Sillan poikkileikkaus voi olla suljettu symmetrinen umpirakenne tai avorakenne, jossa on ulokkeellinen hoitotaso. Ristikon sauvat ovat RHS-putkia. Rakenteeseen voi vaikuttaa jatkuvia kuormia, pistekuormia sekä näistä johdetut, ekvivalenttiin staattiseen voimaan perustuvat maanjäristyskuormat. Diplomityössä on perehdytty mitoitustyökalussa sovellettuihin teorioihin. Voimasuureiden laskenta perustuu 2-tukisina palkkeina käsiteltävien siltalohkojen ratkaisuun ja palkkianalogiaan, jossa ristikon sauvavoimat ratkaistaan käsittelemällä ristikkoa palkkina. Sauvojen kestävyyden laskenta perustuu SFS-EN 1993-1-1 -normiin, joka on osa Eurocode -rakennesuunnittelunormistoa. Lisäksi työssä on käsitelty ristikkoliitosten mitoitusta SFS-EN 1993-1-8 mukaan. Mitoitusohjelman toimivuutta on testattu tarkastelemalla esimerkkisiltaa laaditulla mitoituspohjalla ja Autodesk Robot Professional 2013 -FE-analyysiohjelmisuolla. Tulosten perusteella mitoitustyökalua voidaan käyttää ainakin tarjousvaiheen nopeisiin tarkasteluihin ja omamassan määritykseen, mutta myös lopulliseen mitoitukseen, mikäli hyväksytään konservatiivinen mitoitus.
Resumo:
Parin viime vuosikymmenen aikana on kehitetty huomattavasti entistä lujempia teräslaatuja, joiden käyttö ei kuitenkaan ole yleistynyt läheskään samaan tahtiin. Korkeamman hinnan lisäksi yksi merkittävä syy tähän on, että suunnittelijoilla ei usein ole riittäviä tietoja siitä, millaisissa tilanteissa lujemman teräslaadun käytöstä on merkittävää hyötyä. Tilannetta ei myöskään helpota se, että käytössä olevat standardit eivät tarjoa lainkaan ohjeistusta kaikkein lujimpien, myötörajaltaan yli 700MPa terästen käyttöön ja mitoitukseen. Tässä työssä pyritään tarjoamaan suunnittelijalle ohjeita ja nyrkkisääntöjä sopivan lujuusluokan ja profiilin valintaan sekä yleisesti lujempien teräslaatujen käyttöön. Lujemman teräslaadun käytöllä voidaan keventää suunniteltavaa rakennetta ja saada aikaan huomattavia painonsäästöjä. Usein ongelmaksi nousevat kuitenkin stabiiliuskriteerit, sillä teräksen lommahduskestävyys määräytyy suuresti sen lujuusluokasta siten, että mitä lujempaa teräs on, sitä helpommin se lommahtaa. Kun tämä yhdistetään siihen, että lujempaa terästä käytettäessä rakenteesta tulee optimoituna muutenkin pienempi ja kevyempi, kasvaa näiden kahden asian yhteisvaikutuksena kantokyvyn mukaan mitoitetun rakenteen taipuma korkeampiin lujuusluokkiin edetessä hyvin nopeasti sallittujen rajojen yli. Työssä etsitään siksi keinoja sopivan kompromissin löytämiseksi lujuuden ja jäykkyyden välille. Koska muotoilulla ja poikkileikkauksella on suuri merkitys sekä taipuman että stabiliteetin kannalta, tutkitaan erilaisia poikkileikkausvaihtoehtoja ja etsitään optimaalista poikkileikkausta taivutuspalkille matemaattisen optimointimallin avulla. Kun eri poikkileikkausvaihtoehdot on käsitelty ja optimoitu taivutuksen suhteen, tutkitaan poikkileikkauksia myös muissa kuormitustapauksissa. Huomattavan raskaan laskentatyön takia apuna käytetään Matlab-ohjelmistoa itse optimointiin ja Femap-ohjelmaa muiden kuormitustapausten tutkimiseen ja tulosten verifioitiin.
Resumo:
Thermal cutting methods, are commonly used in the manufacture of metal parts. Thermal cutting processes separate materials by using heat. The process can be done with or without a stream of cutting oxygen. Common processes are Oxygen, plasma and laser cutting. It depends on the application and material which cutting method is used. Numerically-controlled thermal cutting is a cost-effective way of prefabricating components. One design aim is to minimize the number of work steps in order to increase competitiveness. This has resulted in the holes and openings in plate parts manufactured today being made using thermal cutting methods. This is a problem from the fatigue life perspective because there is local detail in the as-welded state that causes a rise in stress in a local area of the plate. In a case where the static utilization of a net section is full used, the calculated linear local stresses and stress ranges are often over 2 times the material yield strength. The shakedown criteria are exceeded. Fatigue life assessment of flame-cut details is commonly based on the nominal stress method. For welded details, design standards and instructions provide more accurate and flexible methods, e.g. a hot-spot method, but these methods are not universally applied to flame cut edges. Some of the fatigue tests of flame cut edges in the laboratory indicated that fatigue life estimations based on the standard nominal stress method can give quite a conservative fatigue life estimate in cases where a high notch factor was present. This is an undesirable phenomenon and it limits the potential for minimizing structure size and total costs. A new calculation method is introduced to improve the accuracy of the theoretical fatigue life prediction method of a flame cut edge with a high stress concentration factor. Simple equations were derived by using laboratory fatigue test results, which are published in this work. The proposed method is called the modified FAT method (FATmod). The method takes into account the residual stress state, surface quality, material strength class and true stress ratio in the critical place.
Resumo:
Government websites offer great benefits to citizens and governments. Such benefits, however,cannot be realized if websites are unusable. This study investigates usability of government websites in Uganda.Using the feature investigation method, the study evaluated four Ugandan government websites according tothree perspectives. Results show that websites are partially usable in the design layout and navigationperspectives but are rather weak in stating legal policies. Evaluation results provide the Ugandan governmentwith a clear picture of what needs to be improved according to international website design standards. Moreover,the parsimonious evaluation framework proposed in the research is useful for any country that wants to do aquick and easy evaluation of their government websites.
Resumo:
Problem Statement: Classroom facilities developed as new construction or renovation projects for UT System institutions tend to be developed as individual, ad hoc project. There are significant opportunities for process improvement is establishing standard business processes for developing Smart Classroom, establishing design standards and referring to prototype facilities developed at other institutions. [See PDF for complete abstract]
Resumo:
Background. Cardiovascular disease (CVD) exhibits the most striking public health significance due to its high prevalence and mortality as well as huge economic burdens all over the world, especially in industrialized countries. Major risk factors of CVDs have been the targets of population-wide prevention in the United States. Economic evaluations provide structured information in regard to the efficiency of resource utilization which can inform decisions of resource allocation. The main purpose of this review is to investigate the pattern of study design of economic evaluations for interventions of CVDs. ^ Methods. Primary journal articles published during 2003-2008 were systematically retrieved via relevant keywords from Medline, NHS Economic Evaluation Database (NHS EED) and EBSCO Academic Search Complete. Only full economic evaluations for narrowly defined CVD interventions were included for this review. The methodological data of interest were extracted from the eligible articles and reorganized in Microsoft Access database. Chi-square tests in SPSS were used to analyze the associations between pairs of categorical data. ^ Results. One hundred and twenty eligible articles were reviewed after two steps of literature selection with explicit inclusion and exclusion criteria. Descriptive statistics were reported regarding the evaluated interventions, outcome measures, unit costing and cost reports. The chi-square test of the association between prevention level of intervention and category of time horizon showed no statistical significance. The chi-square test showed that sponsor type was significantly associated with whether new or standard intervention being concluded as more cost effective. ^ Conclusions. Tertiary prevention and medication interventions are the major interests for economic evaluators. The majority of the evaluations were claimed from either a provider’s or a payer’s perspective. Almost all evaluations adopted gross costing strategy for unit cost data rather than micro costing. EQ-5D is the most commonly used instrument for subjective outcome measurement. More than half of the evaluations used decision analytic modeling techniques. The lack of consistency in study design standards in published evaluations appears in several aspects. Prevention level of intervention is not likely to be a factor for evaluators to decide whether to design an evaluation in a lifetime horizon or not. Published evaluations sponsored by industry are more likely to conclude that new intervention is more cost effective than standard intervention.^
Resumo:
Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^
Resumo:
Es conocido que las dimensiones de los puentes de ferrocarril han ido cambiando debido a las estrictas condiciones de trazado impuestas en las líneas de alta velocidad. Además, la creciente preocupación de la sociedad por cuidar y proteger el medio ambiente, reflejado en la correspondiente normativa, ha generado nuevos condicionantes en el diseño de estas infraestructuras. En concreto, se ha limitado el movimiento de grandes volúmenes de terreno particularmente en los espacios protegidos. Por estas razones, hoy en día se proyectan y construyen puentes de ferrocarril más altos y más largos en todo el mundo. En España se han construido varios viaductos de pilas altas para líneas de alta velocidad. Ejemplos de estas infraestructuras son el Viaducto O’Eixo y el Viaducto de Barbantiño, situados en la línea de alta velocidad Madrid-Galicia, Estos viaductos altos se caracterizan por tener una mayor flexibilidad lateral y una frecuencia fundamental de oscilación baja, de hasta 0.2 Hz. La respuesta dinámica de este tipo de estructura puede aumentar como consecuencia de la aproximación entre la frecuencias propias de la misma y las de excitación debidas al paso del tren y a la acción del viento. Por lo tanto, estas estructuras pueden presentar problemas a la hora de cumplir con las limitaciones impuestas en las normas de diseño de puentes de ferrocarril, y otras, para garantizar la seguridad del tráfico y el confort de los viajeros. La respuesta dinámica lateral de viaductos de pilas altas no ha sido suficientemente estudiada en la literatura científica. Se pueden intuir varios de los motivos para explicar esta carencia. El primero es la relativamente reciente aparición de este tipo de viaductos asociados al desarrollo de la alta velocidad. Por otro lado, se hace necesario, para estudiar este tema, construir nuevos modelos numéricos adecuados para el estudio de la interacción dinámica lateral del puente y del tren. La interacción entre el puente y un tren viajando sobre él es un problema dinámico no lineal, dependiente del tiempo y de acoplamiento entre los dos subsistemas que intervienen (vehículo y puente). Los dos subsistemas, que pueden ser modelados como estructuras elásticas, interaccionan el uno con el otro a través de las fuerzas de contacto, que tiene una marcada naturaleza no lineal por el rozamiento entre rueda y carril, y por la geometría de los perfiles de estos dos elementos en contacto. En esta tesis, se desarrolla la formulación completa de un modelo no lineal de interacción tren-vía-puente-viento que reproduce adecuadamente las fuerzas laterales de contacto rueda-carril, fuerzas que van a tener una gran influencia en los índices de seguridad del tráfico. Este modelo se ha validado a partir de casos resueltos en la literatura científica, y de medidas experimentales tomadas en eventos dinámicos ocurridos en los viaductos de Arroyo de Valle y Arroyo de las Piedras. Puentes altos que han estado monitorizados en servicio durante dos años. En los estudios realizados en este trabajo, se cuantifican, empleando el modelo construido, los niveles de seguridad del tráfico y de confort de los pasajeros de trenes ligeros de alta velocidad, como el tren articulado AVE S-100, que viajan sobre viaductos altos sometidos, o no, a fuertes vientos laterales racheados. Finalmente, se ha obtenido el grado de mejora de la seguridad del tráfico y del confort de los viajeros, cuando se emplean pantallas anti-viento en el tablero y amortiguadores de masa sintonizados en la cabeza de las pilas de un viaducto alto. Resultando, el uso simultaneo de estos dos dispositivos (pantallas y amortiguadores de masa), en puentes altos de líneas de alta velocidad, una opción a considerar en la construcción de estas estructuras para elevar significativamente el nivel de servicio de las mismas. It is known that dimensions of railway bridges have been changing due to the strict high-speed lines layout parameters. Moreover, the growing concern of society to take care of and protect the environment, reflected in the corresponding regulations, has created new environment requirements for the design of these infrastructures. Particularly, the mentioned regulations do not allow designers to move far from terrain to build these railway lines. Due to all these reasons, longer and higher railway bridges are being designed and built around the world. In Spain, several high pier railway viaducts have been built for high speed lines. Barbantiño Viaduct and Eixo Viaduct, belonging to the Madrid-Galicia high speed line, are examples of this kind of structures. These high viaducts have great lateral flexibility and a low fundamental vibration frequency of down to 0.2 Hz. The dynamic response of high speed railway bridges may increase because of the approximation between the natural viaduct frequencies and the excitation ones due to the train travel and the wind action. Therefore, this bridge response could not satisfy the serviceability limits states, for traffic safety and for passenger comfort, considered by the design standards of high speed bridges. It is difficult to find papers in the scientific literature about the lateral response of high-speed trains travel over long viaducts with high piers. Several reasons could explain this issue. On one hand, the construction of this kind of viaduct is relatively recent and it is associated to the development of the high speed railway. On the other hand, in order to study the dynamic lateral interaction between the train and the high bridge, it is necessary to build new numerical and complex models. The interaction between the bridge-track subsystem and the vehicle subsystem travelling over the bridge is a coupling, nonlinear and time dependent problem. Both subsystems, train and bridge, which can be modelled as elastic structures, interact each other through the contact forces. These forces have a strong nonlinear nature due to the friction and the geometry of rail and wheel profiles. In this thesis, the full formulation of a train-track-bridge-wind nonlinear interaction model is developed. This model can reproduce properly the lateral contact wheel-rail forces, which have a great influence on traffic safety indices. The validation of the model built has been reached through interaction solved cases found in the scientific literature and experimental measures taken in dynamic events which happened at Arroyo de las Piedras and Arroyo del Valle Viaducts. These high bridges have been controlled during two years of service by means of structural health monitoring. In the studies carried out for this thesis, the levels of traffic safety and passenger comfort are quantified using the interaction model built, in the cases of high speed and light trains, as AVE S-100, travelling over high pier bridges and with or without lateral turbulent winds acting. Finally, the improvement rate of the traffic safety and passenger comfort has been obtained, when wind barriers are used at the bridge deck and tuned mass dampers are installed at the pier heads of a high viaduct. The installation of both devices, wind barriers and tuned mass damper, at the same time, turned out to be a good option to be considered in the design of high pier railway viaducts, to improve significantly the serviceability level of this kind of structures.
Resumo:
Esta tesis trata sobre la construcción modular ligera, dentro del contexto de la eficiencia energética y de cara a los conceptos de nZEB (near Zero Energy Building) y NZEB (Net Zero Energy Building) que se manejan en el ámbito europeo y específicamente dentro del marco regulador de la Directiva 2010/31 UE. En el contexto de la Unión Europea, el sector de la edificación representa el 40% del total del consumo energético del continente. Asumiendo la necesidad de reducir este consumo se han planteado, desde los organismos de dirección europeos, unos objetivos (objetivos 20-20-20) para hacer más eficiente el parque edificatorio. Estos objetivos, que son vinculantes en términos de legislación, comprometen a todos los estados miembros a conseguir la meta de reducción de consumo y emisiones de GEI (Gases de Efecto Invernadero) antes del año 2020. Estos conceptos de construcción modular ligera (CML) y eficiencia energética no suelen estar asociados por el hecho de que este tipo de construcción no suele estar destinada a un uso intensivo y no cuenta con unos cerramientos con niveles de aislamiento de acuerdo a las normativas locales o códigos de edificación de cada país. El objetivo de nZEB o NZEB, e incluso Energy Plus, según sea el caso, necesariamente (y así queda establecido en las normativas), dependerá no sólo de la mejora de los niveles de aislamiento de los edificios, sino también de la implementación de sistemas de generación renovables, independientemente del tipo de sistema constructivo con el que se trabaje e incluso de la tipología edificatoria. Si bien es cierto que los niveles de industrialización de la sociedad tecnológica actual han alcanzado varias de las fases del proceso constructivo - sobre todo en cuanto a elementos compositivos de los edificios- también lo es el hecho de que las cotas de desarrollo conseguidas en el ámbito de la construcción no llegan al nivel de evolución que se puede apreciar en otros campos de las ingenierías como la aeronáutica o la industria del automóvil. Aunque desde finales del siglo pasado existen modelos y proyectos testimoniales de construcción industrializada ligera (CIL) e incluso ya a principios del siglo XX, ejemplos de construcción modular ligera (CML), como la Casa Voisin, la industrialización de la construcción de edificios no ha sido una constante progresiva con un nivel de comercialización equiparable al de la construcción masiva y pesada. Los términos construcción industrializada, construcción prefabricada, construcción modular y construcción ligera, no siempre hacen referencia a lo mismo y no siempre son sinónimos entre sí. Un edificio puede ser prefabricado y no ser modular ni ligero y tal es el caso, por poner un ejemplo, de la construcción con paneles de hormigón prefabricado. Lo que sí es una constante es que en el caso de la construcción modular ligera, la prefabricación y la industrialización, casi siempre vienen implícitas en muchos ejemplos históricos y actuales. Con relación al concepto de eficiencia energética (nZEB o incluso NZEB), el mismo no suele estar ligado a la construcción modular ligera y/o ligera industrializada; más bien se le ve unido a la idea de cerramientos masivos con gran inercia térmica propios de estándares de diseño como el Passivhaus; y aunque comúnmente a la construcción ligera se le asocian otros conceptos que le restan valor (corta vida útil; función y formas limitadas, fuera de todo orden estético; limitación en los niveles de confort, etc.), los avances que se van alcanzando en materia de tecnologías para el aprovechamiento de la energía y sistemas de generación renovables, pueden conseguir revertir estas ideas y unificar el criterio de eficiencia + construcción modular ligera. Prototipos y proyectos académicos– como el concurso Solar Decathlon que se celebra desde el año 2002 promovido por el DOE (Departamento de Energía de los Estados Unidos), y que cuenta con ediciones europeas como las de los años 2010 y 2012, replantean la idea de la construcción industrializada, modular y ligera dentro del contexto de la eficiencia energética, con prototipos de viviendas de ± 60m2, propuestos por las universidades concursantes, y cuyo objetivo es alcanzar y/o desarrollar el concepto de NZEB (Net Zero Energy Building) o edificio de energía cero. Esta opción constructiva no sólo representa durabilidad, seguridad y estética, sino también, rapidez en la fabricación y montaje, además de altas prestaciones energéticas como se ha podido demostrar en las sucesivas ediciones del Solar Decathlon. Este tipo de iniciativas de desarrollo de tecnologías constructivas, no sólo apuntan a la eficiencia energética sino al concepto global de energía neta, Energía plus o cero emisiones de CO2. El nivel de emisiones por la fabricación y puesta en obra de los materiales de construcción depende, en muchos casos, no solo de la propia naturaleza del material, sino también de la cantidad de recursos utilizados para producir una unidad de medida determinada (kg, m3, m2, ml, etc). En este sentido podría utilizarse, en muchos casos, el argumento válido de que a menos peso, y a menos tamaño, menos emisiones globales de gases de efecto invernadero y menos contaminación. Para el trabajo de investigación de esta tesis se han tomado como referencias válidas para estudio, prototipos tanto de CML (Modular 3D) como de CIL (panelizado y elementos 2D), dado que para los fines de análisis de las prestaciones energéticas de los materiales de cerramiento, ambos sistemas son equiparables. Para poder llegar a la conclusión fundamental de este trabajo de tesis doctoral - que consiste en demostrar la viabilidad tecnológica/ industrial que supone la combinación de la eficiencia energética y la construcción modular ligera - se parte del estudio del estado de la técnica ( desde la selección de los materiales y los posibles procesos de industrialización en fábrica, hasta su puesta en obra, funcionamiento y uso, bajo los conceptos de consumo cero, cero emisiones de carbono y plus energético). Además -y con un estado de la técnica que identifica la situación actual- se llevan a cabo pruebas y ensayos con un prototipo a escala natural y células de ensayo, para comprobar el comportamiento de los elementos compositivos de los mismos, frente a unas condicionantes climáticas determinadas. Este tipo de resultados se contrastan con los obtenidos mediante simulaciones informáticas basadas en los mismos parámetros y realizadas en su mayoría mediante métodos simplificados de cálculos, validados por los organismos competentes en materia de eficiencia energética en la edificación en España y de acuerdo a la normativa vigente. ABSTRACT This thesis discusses lightweight modular construction within the context of energy efficiency in nZEB (near Zero Energy Building) and NZEB (Net Zero Energy Building) both used in Europe and, specifically, within the limits of the regulatory framework of the EU Directive 2010/31. In the European Union the building sector represents 40% of the total energy consumption of the continent. Due to the need to reduce this consumption, European decision-making institutions have proposed aims (20-20-20 aims) to render building equipment more efficient. These aims are bound by law and oblige all member States to endeavour to reduce consumption and GEI emissions before the year 2020. Lightweight modular construction concepts and energy efficiency are not generally associated because this type of building is not normally meant for intensive use and does not have closures with insulation levels which fit the local regulations or building codes of each country. The objective of nZEB or NZEB and even Energy Plus, depending on each case, will necessarily be associated (as established in the guidelines) not only with the improvement of insulation levels in buildings, but also with the implementation of renewable systems of generation, independent of the type of building system used and of the building typology. Although it is true that the levels of industrialisation in the technological society today have reached several of the building process phases - particularly in the composite elements of buildings - it is also true that the quotas of development achieved in the area of construction have not reached the evolutionary levelfound in other fields of engineering, such as aeronautics or the automobile industry. Although there have been models and testimonial projects of lightweight industrialised building since the end of last century, even going back as far as the beginning of the XX century with examples of lightweight modular construction such as the Voisin House, industrialisation in the building industry has not been constant nor is its comercialisation comparable to massive and heavy construction. The terms industrialised building, prefabricated building, modular building and lightweight building, do not always refer to the same thing and they are not always synonymous. A building can be prefabricated yet not be modular or lightweight. To give an example, this is the case of building with prefabricated concrete panels. What is constant is that, in the case of lightweight modular construction, prefabrication and industrialisation are almost always implicit in many historical and contemporary examples. Energy efficiency (nZEB or even NZEB) is not normally linked to lightweight modular construction and/or industrialised lightweight; rather, it is united to the idea of massive closureswith high thermal inertia typical of design standards such as the Passive House; and although other concepts that subtract value from it are generally associated with lightweight building (short useful life, limited forms and function, inappropriate toany aesthetic pattern; limitation in comfort levels, etc.), the advances being achieved in technology for benefitting from energy and renewable systems of generation may well reverse these ideas and unify the criteria of efficiency + lightweight modular construction. Academic prototypes and projects - such as the Solar Decathlon competition organised by the US Department of Energy and celebrated since 2002, with its corresponding European events such as those held in 2010 and 2012, place a different slant on the idea of industrialised, modular and lightweight building within the context of energy efficiency, with prototypes of homes measuring approximately 60m2, proposed by university competitors, whose aim is to reach and/or develop the NZEB concept, or the zero energy building. This building option does not only signify durability, security and aesthetics, but also fast manufacture and assembly. It also has high energy benefits, as has been demonstrated in successive events of the Solar Decathlon. This type of initiative for the development of building technologies, does not only aim at energy efficiency, but also at the global concept of net energy, Energy Plus and zero CO2 emissions. The level of emissions in the manufacture and introduction of building materials in many cases depends not only on the inherent nature of the material, but also on the quantity of resources used to produce a specific unit of measurement (kg, m3, m2, ml, etc.). Thus in many cases itcould be validly arguedthat with less weight and smaller size, there will be fewer global emissions of greenhouse effect gases and less contamination. For the research carried out in this thesis prototypes such as the CML (3D Module) and CIL (panelled and elements) have been used as valid study references, becauseboth systems are comparablefor the purpose of analysing the energy benefits of closure materials. So as to reach a basic conclusion in this doctoral thesis - that sets out to demonstrate the technological/industrial viability of the combination of energy efficiency and lightweight modular construction - the departure point is the study of the state of the technique (from the selection of materials and the possible processes of industrialisation in manufacture, to their use on site, functioning and use, respecting the concepts of zero consumption, zero emissions of carbon and Energy Plus). Moreover, with the state of the technique identifying the current situation, tests and practices have been carried out with a natural scale prototype and test cells so as to verify the behaviour of the composite elements of these in certain climatic conditions. These types of result are contrasted with those obtained through computer simulation based on the same parameters and done, principally, using simplified methods of calculation, validated by institutions competent in energy efficiency in Spanish building and in line with the rules in force.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Bus stops are key links in the journeys of transit patrons with disabilities. Inaccessible bus stops prevent people with disabilities from using fixed-route bus services, thus limiting their mobility. The Americans with Disabilities Act (ADA) of 1990 prescribes the minimum requirements for bus stop accessibility by riders with disabilities. Due to limited budgets, transit agencies can only select a limited number of bus stop locations for ADA improvements annually. These locations should preferably be selected such that they maximize the overall benefits to patrons with disabilities. In addition, transit agencies may also choose to implement the universal design paradigm, which involves higher design standards than current ADA requirements and can provide amenities that are useful for all riders, like shelters and lighting. Many factors can affect the decision to improve a bus stop, including rider-based aspects like the number of riders with disabilities, total ridership, customer complaints, accidents, deployment costs, as well as locational aspects like the location of employment centers, schools, shopping areas, and so on. These interlacing factors make it difficult to identify optimum improvement locations without the aid of an optimization model. This dissertation proposes two integer programming models to help identify a priority list of bus stops for accessibility improvements. The first is a binary integer programming model designed to identify bus stops that need improvements to meet the minimum ADA requirements. The second involves a multi-objective nonlinear mixed integer programming model that attempts to achieve an optimal compromise among the two accessibility design standards. Geographic Information System (GIS) techniques were used extensively to both prepare the model input and examine the model output. An analytic hierarchy process (AHP) was applied to combine all of the factors affecting the benefits to patrons with disabilities. An extensive sensitivity analysis was performed to assess the reasonableness of the model outputs in response to changes in model constraints. Based on a case study using data from Broward County Transit (BCT) in Florida, the models were found to produce a list of bus stops that upon close examination were determined to be highly logical. Compared to traditional approaches using staff experience, requests from elected officials, customer complaints, etc., these optimization models offer a more objective and efficient platform on which to make bus stop improvement suggestions.
Resumo:
The study analyzes the need for a four-lane highway between St. Louis and St. Paul, and finds it to be needed; it analyzes the highway's feasibility, and finds it to be feasible; it analyzes alternative design standards and suggests that it be built to expressway standards; and, the study evaluates alternative routes and presents four "finalist" routes for your consideration.
Resumo:
The study analyzes the need for a four-lane highway between St. Louis and St. Paul, and finds it to be needed; it analyzes the highway's feasibility, and finds it to be feasible; it analyzes alternative design standards and suggests that it be built to expressway standards; and, the study evaluates alternative routes and presents four "finalist" routes for your consideration.
Resumo:
Tässä diplomityössä perehdytään WAP:in Push -viitekehykseen. WAP-standardit määrittelevät kuinka Internet-tyyppisiä palveluita, joita voidaan käyttää erilaisia mobiileja päätelaiteitteita käyttäen, toteutetaan tehokkaalla ja verkkoteknologiasta riippumattomalla tavalla. WAP pohjautuu Internet:iin, mutta huomioi pienten päätelaitteiden ja mobiiliverkkojen rajoitukset ja erikoisominaisuudet. WAP Push viitekehys määrittelee verkon aloittaman palvelusisällön toimittamisen. Työn teoriaosassa käydään läpi yleinen WAP-arkkitehtuuri ja WAP-protokollapino käyttäen vertailukohtina lanka-Internetin arkkitehtuuria ja protokollapinoa. Edellistä perustana käyttäen tutustaan WAP Push -viitekehykseen. Käytännönosassa kuvataan WAP Push -välityspalvelimen suunnittelu ja kehitystyö. WAP Push -välityspalvelin on keskeinen verkkoelementti WAP Push -viitekehyksessä. WAP Push -välityspalvelin yhdistää Internetin ja mobiiliverkon tavalla, joka piilottaa teknologiaeroavaisuudet Internetissä olevalta palveluntuottajalta.