960 resultados para Descriptive compact
Resumo:
The rat posterodorsal medial amygdala (MePD) is a brain area in which gonadal hormones induce notable plastic effects in the density of dendritic spines. Dendritic spines are post-synaptic specializations whose shape and spacing change neuronal excitability. Our aim was to obtain new data on the dendritic spines morphology and density from MePD neurons using the carbocyanine dye Dil under confocal microscopy. In adult male rats, the dendritic spine density of the medial branches of the left MePD (mean +/- SD) was 1.15 +/- 0.67 spines/dendritic mu m. From the total sampled, approximately 53% of the spines were classified as thin, 22.5% as ""mushroom-like"", and 21.5% as stubby/wide. Other spine shapes (3%) included those ramified, with a filopodium-like or a gemule appearance, and others with a protruding spinule. Additional experiment joining Dil and synaptophysin (a pre-synaptic protein) labeling suggested synaptic sites on dendritic shafts and spines. Dendritic spines showed synaptophysin puncta close to their head and neck, although some spines had no evident labeled puncta on them or, conversely, multiple puncta appeared upon one spine. These results advance previous light microscopy results by revealing features and complexities of the dendritic spines at the same time that give new insight on the possible synaptic organization of the adult rat MePD. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
In this work, a new method of optimization is successfully applied to the theoretical design of compact, actively shielded, clinical MRI magnets. The problem is formulated as a two-step process in which the desired current densities on multiple, cc-axial surface layers are first calculated by solving Fredholm equations of the first kind. Non-linear optimization methods with inequality constraints are then invoked to fit practical magnet coils to the desired current densities. The current density approach allows rapid prototyping of unusual magnet designs. The emphasis of this work is on the optimal design of short, actively-shielded MRI magnets for whole-body imaging. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric, and asymmetric MRI magnets. Magnet designs are presented for actively-shielded, symmetric magnets of coil length 1.0 m, which is considerably shorter than currently available designs of comparable dsv size. Novel, actively-shielded, asymmetric magnet designs are also presented in which the beginning of a 50-cm dsv is positioned just 11 cm from the end of the coil structure, allowing much improved access to the patient and reduced patient claustrophobia. Magn Reson Med 45:331540, 2001. (C) 2001 Wiley-Liss, Inc.
Resumo:
New designs for force-minimized compact high-field clinical MRI magnets are described. The design method is a modified simulated annealing (SA) procedure which includes Maxwell forces in the error function to be minimized. This permits an automated force reduction in the magnet designs while controlling the overall dimensions of the system. As SA optimization requires many iterations to achieve a final design, it is important that each iteration in the procedure is rapid. We have therefore developed a rapid force calculation algorithm. Novel designs for short 3- and 4-T clinical MRI systems are presented in which force reduction has been invoked. The final designs provide large homogeneous regions and reduced stray fields in remarkable short magnets. A shielded 4-T design that is approximately 30% shorter than current designs is presented. This novel magnet generates a full 50-cm diameter homogeneous region.
Resumo:
Some results are obtained for non-compact cases in topological vector spaces for the existence problem of solutions for some set-valued variational inequalities with quasi-monotone and lower hemi-continuous operators, and with quasi-semi-monotone and upper hemi-continuous operators. Some applications are given in non-reflexive Banach spaces for these existence problems of solutions and for perturbation problems for these set-valued variational inequalities with quasi-monotone and quasi-semi-monotone operators.
Resumo:
Water wetting is a crucial issue in carbon dioxide (CO.) corrosion of multiphase flow pipelines made from mild steel. This study demonstrates the use of a novel benchtop apparatus, a horizontal rotating cylinder, to study the effect of water wetting on CO2 corrosion of mild steel in two-phase flow. The setup is similar to a standard rotating cylinder except for its horizontal orientation and the presence of two phases-typically water and oil. The apparatus has been tested by using mass-transfer measurements and CO2 corrosion measurements in single-phase water flow. CO2 corrosion measurements were subsequently performed using a water/hexane mixture with water cuts varying between 5% and 50%. While the metal surface was primarily hydrophilic under stagnant. conditions, a variety of dynamic water wetting situations was encountered as the water cut and fluid velocity were altered. Threshold velocities were identified at various water cuts when the surface became oil-wet and corrosion stopped.
Testamentary capacity and aphasia: A descriptive case report with implications for clinical practice
Resumo:
Background: Testamentary capacity (the capacity to make a will) is recognised in the literature as an important issue for speech-language pathologists' assessment of people with aphasia, but current guidelines for clinical practice lack an empirical base. Aims: The research aimed to suggest some guidelines for clinical practice based on information considered relevant for the court in determining testamentary capacity. Methods & Procedures: A recent legal case involving a challenge to the will of a woman with severe aphasia was critically examined with reference to current guidelines in the literature regarding assessment of testamentary capacity. Outcomes & Results: Examination of the information available on the case indicated that the judge gave priority to accounts of the everyday communication of the person with aphasia (including reported discourse samples) over the information provided by expert medical witnesses. The extent to which communication effectiveness could be maximised was found to be a matter of key significance to the determination of capacity. Conclusions: This study has implications for speech-language pathologists' assessment practices and reports, as well as for scope of practice with regard to legal decision making of people with aphasia. These issues are discussed in relation to the World Health Organisation's ICF framework of functioning for social participation.
Resumo:
The stability of the color flavor locked phase in the presence of a strong magnetic field is investigated within the phenomenological MIT bag model. It is found that the minimum value of the energy per baryon in a color flavor locked state at vanishing pressure is lower than the corresponding one for unpaired magnetized strange quark matter and, as the magnetic field increases, the energy per baryon decreases. This implies that magnetized color flavor locked matter is more stable and could become the ground state inside neutron stars. The anisotropy of the pressures is discussed. The mass-radius relation for such stars is also studied.
Resumo:
The stability of the color flavor locked phase in the presence of a strong magnetic field is investigated within the phenomenological MIT bag model, taking into account the variation of the strange quark mass, the baryon density, the magnetic field, as well as the bag and gap parameters. It is found that the minimum value of the energy per baryon in a color flavor locked state at vanishing pressure is lower than the corresponding one for unpaired magnetized strange quark matter and, as the magnetic field increases, the energy per baryon decreases. This implies that magnetized colorflavor locked matter is more stable and could become the ground state inside neutron stars. The mass-radius relation for such stars is also studied.
Resumo:
Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.
Resumo:
Conferência: IEEE 24th International Conference on Application-Specific Systems, Architectures and Processors (ASAP)- Jun 05-07, 2013
Resumo:
Mestrado em Fisioterapia
Resumo:
A thesis submitted for the degree of Doctor of Philosophy