1000 resultados para Dental software


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Besides DNA, dental radiographs play a major role in the identification of victims in mass casualties or in corpses with major postmortem alterations. Computed tomography (CT) is increasingly applied in forensic investigations and is used to scan the dentition of deceased persons within minutes. We investigated different restoration materials concerning their radiopacity in CT for dental identification purposes. METHODS: Extracted teeth with different filling materials (composite, amalgam, ceramic, temporary fillings) were CT scanned. Radiopacities of the filling materials were analyzed in extended CT scale images. RESULTS: Radiopacity values ranged from 6000-8500HU (temporary fillings), 4500-17000HU (composite fillings) and >30710HU (Amalgam and Gold). The values were used to define presets for a 3D colored volume rendering software. CONCLUSIONS: The effects of filling material caused streak artifacts could be distinctively reduced for the assessment of the dental status and a postprocessing algorithm was introduced that allows for 3D color encoded visualization and discrimination of different dental restorations based on postmortem CT data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dental radiographs play the major role in the identification of victims in mass casualties besides DNA. Under circumstances such as those caused by the recent tsunami in Asia, it is nearly impossible to document the entire dentition using conventional x-rays as it would be too time consuming. Multislice computed tomography can be used to scan the dentition of a deceased within minutes, and the postprocessing software allows visualization of the data adapted to every possible antemortem x-ray for identification. We introduce the maximum intensity projection of cranial computed tomography data for the purpose of dental identification exemplarily in a case of a burned corpse. As transportable CT scanners already exist, these could be used to support the disaster victim identification teams in the field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of dental processing software for computed tomography (CT) data (Dentascan) is described on postmortem (pm) CT data for the purpose of pm identification. The software allows reconstructing reformatted images comparable to conventional panoramic dental radiographs by defining a curved reconstruction line along the teeth on oblique images. Three corpses that have been scanned within the virtopsy project were used to test the software for the purpose of dental identification. In every case, dental panoramic images could be reconstructed and compared to antemortem radiographs. The images showed the basic component of teeth (enamel, dentin, and pulp), the anatomic structure of the alveolar bone, missing or unerupted teeth as well as restorations of the teeth that could be used for identification. When streak artifacts due to metal-containing dental work reduced image quality, it was still necessary to perform pm conventional radiographs for comparison of the detailed shape of the restoration. Dental identification or a dental profiling seems to become possible in a noninvasive manner using the Dentascan software.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of information technology (IT) in dentistry is far ranging. In order to produce a working document for the dental educator, this paper focuses on those methods where IT can assist in the education and competence development of dental students and dentists (e.g. e-learning, distance learning, simulations and computer-based assessment). Web pages and other information-gathering devices have become an essential part of our daily life, as they provide extensive information on all aspects of our society. This is mirrored in dental education where there are many different tools available, as listed in this report. IT offers added value to traditional teaching methods and examples are provided. In spite of the continuing debate on the learning effectiveness of e-learning applications, students request such approaches as an adjunct to the traditional delivery of learning materials. Faculty require support to enable them to effectively use the technology to the benefit of their students. This support should be provided by the institution and it is suggested that, where possible, institutions should appoint an e-learning champion with good interpersonal skills to support and encourage faculty change. From a global prospective, all students and faculty should have access to e-learning tools. This report encourages open access to e-learning material, platforms and programs. The quality of such learning materials must have well defined learning objectives and involve peer review to ensure content validity, accuracy, currency, the use of evidence-based data and the use of best practices. To ensure that the developers' intellectual rights are protected, the original content needs to be secure from unauthorized changes. Strategies and recommendations on how to improve the quality of e-learning are outlined. In the area of assessment, traditional examination schemes can be enriched by IT, whilst the Internet can provide many innovative approaches. Future trends in IT will evolve around improved uptake and access facilitated by the technology (hardware and software). The use of Web 2.0 shows considerable promise and this may have implications on a global level. For example, the one-laptop-per-child project is the best example of what Web 2.0 can do: minimal use of hardware to maximize use of the Internet structure. In essence, simple technology can overcome many of the barriers to learning. IT will always remain exciting, as it is always changing and the users, whether dental students, educators or patients are like chameleons adapting to the ever-changing landscape.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation investigated perspectives on cultural competence among African-American women patients, staff, and the administrator of a dental clinic serving people living with HIV/AIDS; and evaluated the role of the National Standards for Culturally and Linguistically Appropriate Services in Health Care (CLAS) in advancing the provision of culturally competent care in the clinic. ^ The study was qualitative with data collection via focus groups and individual interviews with a sample of African-American women patients, and individual interviews with a sample of staff and the clinic administrator. Transcripts were coded and themes identified using the software program ATLAS.ti. A cultural audit template was developed and applied to evaluate cultural competency. ^ Among attitudes and behaviors that contributed to the provision of culturally competent care at the clinic were respect and empathic communication. Formal cultural competency was not featured strongly in the methods by which the staff learned to work with diverse populations. Instead cultural competence among the staff was based on thoughtful hiring practices, natural aptitude and a climate that encouraged learning through informal sharing of experiences. The staff and administrator felt that an African-American dentist would be an asset in improving culturally competent care at the clinic. Previous research and national policy also promote the provider-patient racial/ethnic concordance to improve care. In this study, however, the patients were happy with the care provided regardless of the race/ethnicity of the staff, probably reflecting the well developed cultural competence skills of clinic staff overall. ^ The clinic administrator was unaware of the CLAS standards although the clinic was implicitly operated under their mandates. This occurred because the clinic is supported by federal funding and the CLAS standards were incorporated into the requirements. Incorporation into and monitoring of the CLAS standards in federally funded programs therefore appears to be an effective means for ensuring that they are implemented. ^ This study illustrates that cultural competence, though not universally understood, can be systematically investigated to identify what constitutes appropriate care and the factors that support or inhibit it. Among important elements of culturally competent care are respect and empathic communication. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A qualidade óssea, bem como a estabilidade inicial dos implantes, está diretamente relacionada com o sucesso das reabilitações na implantodontia. O presente estudo teve como objetivo analisar a correlação entre índices radiomorfométricos de densidade óssea por meio de radiografias panorâmicas, perfil de qualidade óssea com o auxílio de Tomografia Computadorizada de Feixe Cônico (TCFC) com o uso do software de imagens OsiriX, Análise da Frequência de Ressonância (RFA) e Torque de Inserção do implante. Foram avaliados 160 implantes de 72 indivíduos, com média etária de 55,5 (±10,5) anos. Nas radiografias panorâmicas foram obtidos os índices IM, IPM e ICM, e nas tomografias computadorizadas de feixe cônico, os valores de pixels e a espessura da cortical da crista óssea alveolar, além da estabilidade primária por meio do torque de inserção e análise da frequência de ressonância. Os resultados foram analisados pelo coeficiente de correlação de Spearman, para p<= 0,01 foi obtido entre o torque de inserção e valores de pixels (0.330), o torque de inserção e a espessura da cortical da crista alveolar (0.339), o torque de inserção e o ISQ vestibulo-lingual (0.193), os valores de pixels e espessura da cortical da crista alveolar (0.377), as duas direções vestíbulo-lingual e mesio-distal do ISQ (0.674), o ISQ vestíbulo-lingual e a espessura da cortical da crista alveolar (0.270); os índices radiomorfométricos foram correlacionados entre eles e para p<= 0,05 foi obtido entre torque de inserção e ISQ mesio-distal (0.131), entre o ISQ vestibulo-lingual e os valores de pixels (0.156) e ISQ mesio-distal e IPMI esquerdo (0.149) e ISQ mesio-distal e IPMS esquerdo (0.145). Existe correlação entre a TCFC, o torque de inserção e a RFA na avaliação da qualidade óssea. É possível utilizar, pré-cirurgicamente, os exames de TCFC para avaliar a qualidade e quantidade óssea, tendo em vista as correlações obtidas neste estudo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a series of design games, specifically aimed at exploring shifts in human agency in order to inform the design of context-aware applications. The games focused on understanding information handling issues in dental practice with participants from a university dental school playing an active role in the activities. Participatory design activities help participants to reveal potential implicit technical resources that can be presented explicitly in technologies in order to assist humans in managing their interactions with and amidst technical systems gracefully.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Computer-Aided-Design (CAD) and Computer-Aided-Manufacture (CAM) has been developed to fabricate fixed dental restorations accurately, faster and improve cost effectiveness of manufacture when compared to the conventional method. Two main methods exist in dental CAD/CAM technology: the subtractive and additive methods. While fitting accuracy of both methods has been explored, no study yet has compared the fabricated restoration (CAM output) to its CAD in terms of accuracy. The aim of this present study was to compare the output of various dental CAM routes to a sole initial CAD and establish the accuracy of fabrication. The internal fit of the various CAM routes were also investigated. The null hypotheses tested were: 1) no significant differences observed between the CAM output to the CAD and 2) no significant differences observed between the various CAM routes. Methods: An aluminium master model of a standard premolar preparation was scanned with a contact dental scanner (Incise, Renishaw, UK). A single CAD was created on the scanned master model (InciseCAD software, V2.5.0.140, UK). Twenty copings were then fabricated by sending the single CAD to a multitude of CAM routes. The copings were grouped (n=5) as: Laser sintered CoCrMo (LS), 5-axis milled CoCrMo (MCoCrMo), 3-axis milled zirconia (ZAx3) and 4-axis milled zirconia (ZAx4). All copings were micro-CT scanned (Phoenix X-Ray, Nanotom-S, Germany, power: 155kV, current: 60µA, 3600 projections) to produce 3-Dimensional (3D) models. A novel methodology was created to superimpose the micro-CT scans with the CAD (GOM Inspect software, V7.5SR2, Germany) to indicate inaccuracies in manufacturing. The accuracy in terms of coping volume was explored. The distances from the surfaces of the micro-CT 3D models to the surfaces of the CAD model (CAD Deviation) were investigated after creating surface colour deviation maps. Localised digital sections of the deviations (Occlusal, Axial and Cervical) and selected focussed areas were then quantitatively measured using software (GOM Inspect software, Germany). A novel methodology was also explored to digitally align (Rhino software, V5, USA) the micro-CT scans with the master model to investigate internal fit. Fifty digital cross sections of the aligned scans were created. Point-to-point distances were measured at 5 levels at each cross section. The five levels were: Vertical Marginal Fit (VF), Absolute Marginal Fit (AM), Axio-margin Fit (AMF), Axial Fit (AF) and Occlusal Fit (OF). Results: The results of the volume measurement were summarised as: VM-CoCrMo (62.8mm3 ) > VZax3 (59.4mm3 ) > VCAD (57mm3 ) > VZax4 (56.1mm3 ) > VLS (52.5mm3 ) and were all significantly different (p presented as areas with different colour. No significant differences were observed at the internal aspect of the cervical aspect between all groups of copings. Significant differences (p< M-CoCrMo Internal Occlusal, Internal Axial and External Axial 2 ZAx3 > ZAx4 External Occlusal, External Cervical 3 ZAx3 < ZAx4 Internal Occlusal 4 M-CoCrMo > ZAx4 Internal Occlusal and Internal Axial The mean values of AMF and AF were significantly (p M-CoCrMo and CAD > ZAx4. Only VF of M-CoCrMo was comparable with the CAD Internal Fit. All VF and AM values were within the clinically acceptable fit (120µm). Conclusion: The investigated CAM methods reproduced the CAD accurately at the internal cervical aspect of the copings. However, localised deviations at axial and occlusal aspects of the copings may suggest the need for modifications in these areas prior to fitting and veneering with porcelain. The CAM groups evaluated also showed different levels of Internal Fit thus rejecting the null hypotheses. The novel non-destructive methodologies for CAD/CAM accuracy and internal fit testing presented in this thesis may be a useful evaluation tool for similar applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Questões de ‘preencha as lacunas’ que abordam a etiopatogenia da cárie dental, com ênfase nos fatores etiológicos da cárie precoce da infância, e práticas pertinentes sobre higiene bucal de bebês como forma de orientar pais e cuidadores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microabrasion technique of enamel consists of selectively abrading the discolored areas or causing superficial structural changes in a selective way. In microabrasion technique, abrasive products associated with acids are used, and the evaluation of enamel roughness after this treatment, as well as surface polishing, is necessary. This in-vitro study evaluated the enamel roughness after microabrasion, followed by different polishing techniques. Roughness analyses were performed before microabrasion (L1), after microabrasion (L2), and after polishing (L3).Thus, 60 bovine incisive teeth divided into two groups were selected (n=30): G1- 37% phosphoric acid (37%) (Dentsply) and pumice; G2- hydrochloric acid (6.6%) associated with silicon carbide (Opalustre - Ultradent). Thereafter, the groups were divided into three sub-groups (n=10), according to the system of polishing: A - Fine and superfine granulation aluminum oxide discs (SofLex 3M); B - Diamond Paste (FGM) associated with felt discs (FGM); C - Silicone tips (Enhance - Dentsply). A PROC MIXED procedure was applied after data exploratory analysis, as well as the Tukey-Kramer test (5%). No statistical differences were found between G1 and G2 groups. L2 differed statistically from L1 and showed superior amounts of roughness. Differences in the amounts of post-polishing roughness for specific groups (1A, 2B, and 1C) arose, which demonstrated less roughness in L3 and differed statistically from L2 in the polishing system. All products increased enamel roughness, and the effectiveness of the polishing systems was dependent upon the abrasive used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teeth are often included in the radiation field during head and neck radiotherapy, and recent clinical evidence suggests that dental pulp is negatively affected by the direct effects of radiation, leading to impaired sensitivity of the dental pulp. Therefore, this study aimed to investigate the direct effects of radiation on the microvasculature, innervation, and extracellular matrix of the dental pulp of patients who have undergone head and neck radiotherapy. Twenty-three samples of dental pulp from patients who finished head and neck radiotherapy were analyzed. Samples were histologically processed and stained with hematoxylin-eosin for morphologic evaluation of the microvasculature, innervation, and extracellular matrix. Subsequently, immunohistochemical analysis of proteins related to vascularization (CD34 and smooth muscle actin), innervation (S-100, NCAM/CD56, and neurofilament), and extracellular matrix (vimentin) of the dental pulp was performed. The morphologic study identified preservation of the microvasculature, nerve bundles, and components of the extracellular matrix in all studied samples. The immunohistochemical analysis confirmed the morphologic findings and showed a normal pattern of expression for the studied proteins in all samples. Direct effects of radiotherapy are not able to generate morphologic changes in the microvasculature, innervation, and extracellular matrix components of the dental pulp in head and neck cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy dispersive X-ray spectroscopy microanalysis (EDX), scanning electron microscopy (SEM), and Archimedes' Principle were used to determine the characteristics of inorganic filler particles in five dental alginates, including Cavex ColorChange (C), Hydrogum 5 (H5), Hydrogum (H), Orthoprint (O), and Jeltrate Plus (JP). The different alginate powders (0.5 mg) were fixed on plastic stubs (n = 5) and sputter coated with carbon for EDX analysis, then coated with gold, and observed using SEM. Volume fractions were determined by weighing a sample of each material in water before and after calcining at 450(°)C for 3 h. The alginate materials were mainly composed of silicon (Si) by weight (C-81.59%, H-79.89%, O-78.87%, H5-77.95%, JP-66.88%, wt). The filler fractions in volume (vt) were as follows: H5-84.85%, JP-74.76%, H-70.03%, O-68.31%, and C-56.10%. The tested materials demonstrated important differences in the inorganic elemental composition, filler fraction, and particle morphology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.