947 resultados para Dental Instruments


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1 - steel brush, L2 - nylon brush, L3 - ultrasound  +  distilled water, L4 - ultrasound + descaling solution and L5 - no cleaning method (control). The burs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5 ) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1  = 0.3558 g; L2  = 0.4275 g; L3  = 0.4652 g; L4  = 0.4396 g e L5  = 0.4854 g; significant differences in the time of use (p  <  0.001) and cleaning method (p  <  0.001). The L1 group showed the worst performance. Regardless of the experimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this in vitro study was to comparatively evaluate the mesio and distal furcation entrance measurements of first maxillary premolar. The measurements were compared with different curette blades. A caliper was used by an examinator to acquire the measurements of root trunk (TR); 1 mm (D1) and 2 mm (D2) both below the furcation entrance. For this study Gracey, Mini Gracey, Padua Lima (PL) and Goldman Fox 4 curettes (Millenium) were selected. Measurements of DT - total distance of the active blade length, DI - width of the active blade, DM - width of the medium part of the active blade were obtained for the curettes. The measurements were obtained in both the coronary face and in the lateral face. The data TR, D1 and D2 presented normal distribution and were statistically analyzed by paired t-test. Statistically significant differences were found in the mesial root trunk region (TR) of both premolars. The mean of the measurements was greater than the distal. Mean and standard deviation were obtained, and both Gracey and Mini Gracey showed mean measurements compatible with the closer furcation entrance (D1 - 1 mm). Goldman Fox 4 showed adaptation only in the mesial face, and Padua Lima showed no access to any of the faces. Thereby it is concluded that the access of the furcation is narrow (D1). The mesial face of the root trunk (TR) showed mean measurement greater than distal face. Gracey and Mini Gracey curettes demonstrated to be compatible for both faces, mesial and distal of the first maxillary premolars studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This report describes a protocol for managing the accidental swallowing of dental instruments in implant dentistry, illustrated by a patient who accidentally swallowed a hexagonal wrench. The first step was to refer the patient to the medical emergency hospital service for radiographic and clinical evaluation. The hexagonal wrench was located in the stomach and was immediately removed with an endoscopic procedure. The gastric mucosa was sampled via biopsy and the sample submitted to the urease test, which was positive for Helicobacter pylori. Triple treatment was instituted for gastritis caused by H pylori to avoid exposing the patient to unnecessary risk. Removal of a foreign body by means of an endoscopic procedure constitutes a safe and effective treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La resistencia de algunos niños a la atención odontológica constituye un problema para los profesionales, el niño y sus padres. Una forma de prevenirla es preparar al niño con anticipación utilizando el juego como espacio transicional para la aceptación de los procedimientos de curación. La experiencia nos ha demostrado su eficacia en la construcción de representaciones en la mente del niño del diagnóstico y del tratamiento. Al anticipar la experiencia a través del juego disminuye su temor. La metodología implementada es la técnica de juego en grupos pequeños de pares. Los niños comprenden la situación odontológica a través de dramatizaciones, dibujos y juegos con instrumental y juguetes En un clima Iúdico, aprenden el uso del instrumental odontológico, se familiariza con el mobiliario y aparatología del consultorio y posteriormente se evalúa la disposición para recibir atención odontológica.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the use of optical coherence tomography (OCT) to detect and quantify demineralization process induced by S. mutans biofilm in third molars human teeth. Artificial lesions were induced by a S. mutans microbiological culture and the samples (N = 50) were divided into groups according to the demineralization time: 3, 5, 7, 9, and 11days. The OCT system was implemented using a light source delivering an average power of 96 mu W in the sample arm, and spectral characteristics allowing 23 mu m of axial resolution. The images were produced with lateral scans step of 10 pan and analyzed individually. As a result of the evaluation of theses images, lesion depth was calculated as function of demineralization time. The depth of the lesion in the root dentine increased from 70 pm to 230,urn (corrected by the enamel refraction index, 1.62 @ 856 nm), depending of exposure time. The lesion depth in root dentine was correlated to demineralization time, showing that it follows a geometrical progression like a bacteria growth law. [GRAPHICS] Progression of lesion depth in root dentine as function of exposure time, showing that it follows a geometrical progression like a bacteria growth law(C) 2009 by Astro Ltd. Published exclusively by WILEY-VCH Verlag GmbH & Co. KGaA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the hypothesis that low-level laser therapy (LLLT) 688 nm and 785 nm accelerate dentin barrier formation and repair process after traumatic pulp exposure. The sample consisted of 45 premolars of capuchin monkeys (Cebus apella) with pulp exposure Class V cavities. All premolars were treated with calcium hydroxide (Ca(OH)(2)), divided in groups of 15 teeth each, and analyzed on 7(th), 25(th), and 60(th) day. Group GI - only Ca(OH)(2), GIF- laser 688 nm, and GIII - laser 785 nm. Laser beam was used in single and punctual dose with the parameters: continuous, 688 nm and 785 nm wavelength, tip`s area of 0.00785 cm(2), power 50 mW, application time 20 s, dose 255 J/cm(2), energy 2 J. Teeth were capped with Ca(OH)(2), Ca(OH)(2) cement and restored with amalgam. All groups presented pulp repair. On 25(th) day the thickness of the formed dentin barrier was different between the groups GI and GII (p < 0.05) and between groups GI and GIII (p < 0.01). On 60(th) day there was difference between GI and GIII (p < 0.01). It may be concluded that, LLLT 688 nm and 785 nm accelerated dentin barrier formation and consequently pulp repair process, with best results using infrared laser 785 nm. (c) 2009 by Astro Ltd. Published exclusively by WLLEY-VCH Verlag GmbH & Co. KGaA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the cohesive strength of composite using self-etching adhesive systems (SE) in the lubrication of instruments between layers of composite. The specimens were made by using a Teflon (R) device. SE were used at the interface to lubricate the instruments: Group 1(G1) - control group, no lubricant was used; Group 2(G2) -Futurabond (R) M; Group 3(G3) - Optibond (R) All-In-One; Group 4(G4) - Clearfil (R) SE Bond; Group 5(G5) - Futurabond (R) NR; Group 6(G6) - Adper (R) SE Plus; Group 7(G7) - One Up Bond (R) F. Specimens were submitted to the tensile test to evaluate the cohesive strength. Data were submitted to the ANOVA and Tukey tests. ANOVA showed a value of p = 0.00. The average means (SD): G2 = 11.33(+/-3.44) a, G3 = 15.36(+/-4.06) ab, G4 = 18.9(+/-4.72) bc, G7 = 19.62(+/-4.46) bc, G5 = 21.02(+/-5.09) bc, G6 = 23.39(+/-4.17) cd, and G1 = 28.49(+/-2.89) d. All SE decreased the cohesive strength of the composite, except for Adper (R) SE Plus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the cohesive strength of the composite using different resinous monomers to lubricate instruments used in the Restorative Dental Modeling Insertion Technique (RDMIT).Materials and Methods: The composite specimens were made by using a prefabricated Teflon device. Different resinous monomers were used at the interface to lubricate the instruments, for a total of 72 specimens divided into 6 groups: 1. control group, no resinous monomer was used; 2. Composite Wetting Resin; 3. C & B Liquid; 4. Scotchbond Multi-Purpose Adhesive; 4. Adper Single Bond Adhesive; 6. Prime & Bond NT. Specimens were submitted to the circular area tensile test to evaluate the cohesive strength at the composite interfaces. Data were analyzed using ANOVA and Tukey's test (alpha = 0.05).Results: ANOVA showed a value of p < 0.0001, which indicated that there were significant differences among the groups. The means (SD) for the different groups were: Adper Single Bond Adhesive: 26 (12) a; control group: 28 (3) ab; Prime & Bond NT: 32 (12) ab; Composite Wetting Resin: 36 (9) abc; C&B Liquid: 38 (7) bc; Scotchbond Multi-Purpose Adhesive: 46 (10) c. Groups denoted with the same letters were not significantly different. Only Scotchbond Multi-Purpose Adhesive, used for direct restorations, had a statistically significantly higher bond strength than the control group, Adper Single Bond Adhesive, and Prime & Bond NT. Adper Single Bond with Adhesive showed a statistically significantly lower mean value than C & B Liquid.Conclusion: The results of this study indicate that the resinous monomers used for lubricating the instruments in the RDMIT did not alter the mechanical properties of the composite, and therefore did not reduce the cohesive bond strength at the composite interfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate, through scanning electronic microscopy, the effect of sharpening with different sharpening stones on the cutting angle of periodontal curettes (Gracey 5-6), and the influence on root surfaces after debridement and planing. The experimental model consisted of two different phases. In the first, the cutting angles of fifteen stainless steel Gracey 5-6 curettes were analyzed under a scanning electronic microscope after being sharpened with different types of stones. In the second phase, the root surfaces of 25 newly extracted teeth were evaluated with a scanning electronic microscope after being debrided with curettes sharpened with different stones. Analysis of the results showed that the synthetic stones (aluminum oxide and carborundum) are more abrasive and produce more irregular cutting angles, whereas Arkansas stones are less abrasive and produce smoother and more defined cutting angles. There was no significant statistical differences among the five groups tested with regard to the degree of irregularity of the root surfaces after instrumentation.