973 resultados para Dental Implants


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this literature review is to discuss the use of dental implants in growing patients and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended to wait for the completion of dental and skeletal growth, except for severe cases of ectodermal dysplasia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The commercial pure titanium (cp-Ti) is currently being used with great success in dental implants. In this work we investigate how the cp-Ti implants can be improved by modifying the metal surface morphology, on which a synthetic material with properties similar to that of the inorganic part of the bone, is deposited to facilitate the bone/implant bonding. This synthetic material is the hydroxyapatite, HA, a calcium-phosphate ceramic. The surface modification consists in the application of a titanium oxide (TiO2) layer, using the thermal aspersion - plasma spray technique, with posterior deposition of HA, using the biomimetic method. The X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray (EDX) and Diffuse Reflectance Infrared Fourier Transform (DRIFT) techniques have been used for characterizing phases, microstructures and morphologies of the coatings. The TiO2 deposit shows a mixture of anatase, rutilo and TiO2-x phases, and a porous and laminar morphology, which facilitate the HA deposition. After the thermal treatment, the previously amorphous structured HA coating, shows a porous homogeneous morphology with particle size of about 2-2.5 μm, with crystallinity and composition similar to that of the biological HA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The oral rehabilitation by dental implants in patients with diabetes remains a controversial issue. The aim of this study was to evaluate the influence of diabetes mellitus and insulin therapy on the bone healing around dental implants using torque removal. Twenty-seven rabbits were randomly divided into 3 groups with 9 animals each: control (C) group, induced diabetic (D) group, and insulin-treated diabetic (ITD) group (10 U/day). After 1 week, one implant was inserted at the tibial metaphysis of the animals. The glucose levels were periodically evaluated through the glucose-oxidase enzymatic method. The animals were killed at 4, 8, and 12 weeks after surgery and the biomechanical test was performed using a torque manometer. Statistically significant differences regarding the removal torque of the implant could not be found at 4 weeks (P = 0.2) among groups. Group C showed statistically higher values than groups D and ITD at the experimental periods of 8 (P = 0.0001 and P = 0.0002, respectively) and 12 weeks (P = 0.0053 and P = 0.001, respectively). There were no statistical differences between D and ITD groups in any of the experimental periods. Diabetes mellitus has negatively influenced the mechanical retention of implants placed at the tibial metaphysis of rabbits. Therapy with insulin did not induce any changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single nucleotide polymorphisms in the promoter region of the human interleukin (IL)-2 (T-330G) and IL-6 (G-174C) genes have modified the transcriptional activity of these cytokines and are associated with several diseases. The aim of this study was to investigate the possible relationship between these single nucleotide polymorphisms and early implant failure. A sample of 74 nonsmokers was divided into 2 groups: test group comprising 34 patients (mean age 49.3 years) with ĝ‰¥1 implants that failed and control group consisting of 40 patients (mean age 43.8 years) with ĝ‰¥1 healthy implants. Genomic deoxyribonucleic acid from oral mucosa was amplified by polymerase chain reaction and analyzed by restriction fragment length polymorphism. Monte Carlo simulations (P < 0.05) were used to assess differences in allele and genotypes frequencies of the single nucleotide polymorphisms between the 2 groups. No significant differences were observed in the allele and genotypes distribution of both polymorphisms when the 2 groups were compared. The results indicate that polymorphisms in the IL-2 (T-330G) and IL-6 (G-174C) genes are not associated with early implant failure, suggesting that the presence of those single nucleotide polymorphisms does not constitute a genetic risk factor for implant loss in the studied population. Copyright © 2005 by Lippincott Williams & Wilkins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the influence of a fluoridated medium on the mechanical properties of an internal hexagon implant-abutment set, by means of compression, mechanical cycling and metallographic characterization by scanning electronic microscopy. Five years of regular use of oral hygiene with a sodium fluoride solution content of 1500 ppm were simulated, immersing the samples in this medium for 184 hours, with the solutions being changed every 12 hours. Data were analyzed at a 95% confidence level with Fisher's exact test. After the action of fluoride ions, a negative influence occurred in the mechanical cycling test performed in a servohydraulic machine (Material Test System-810) set to a frequency of 15 Hz with 100,000 cycles and programmed to 60% of the maximum resistance of static compression test. The sets tended to fracture by compression on the screw, characterized by mixed ruptures with predominance of fragile fracture, as observed by microscopy. An evidence of corrosion by pitting on sample surfaces was found after the fluoride ions action. It may be concluded that prolonged contact with fluoride ions is harmful to the mechanical properties of commercially pure titanium structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this investigation was to accomplish an overview about the principles of the indication and of the success parameters involving immediate and delayed loading dental implants procedures. Studies about the philosophies (immediate and delayed loading dental implants) and their clinical indications will be discussed in order to overview the rules for the clinical success in both techniques. In addition, studies regarding the criteria for immediate loading implants as primary stabilization, surface treatments and bone density and amount will be also analyzed. More important than the philosophy selection, is how and when to use it according to biomechanical rules and principles. Among the vast limitations pointed by the literature regarding procedures of immediate and delayed loading are evidenced the parafunctional habits, primary stabilization, bone quality, surface treatments and the number of dental implants. The anterior region of the jaw seems to be associated with a major percentage of satisfactory results, regardless of rehabilitation procedures. Although several studies have demonstrated high success rates for the immediate loading dental implants, several aspects remain without an explicit definition and further studies are needed to elucidate some reservations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the effect of an Argon-based nonthermal plasma (NTP) surface treatment-operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: Calcium-Phosphate (CaP) and CaP + NTP (CaP-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received 2 plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ca, C, O, and P for the CaP and CaP-Plasma surfaces. Both surfaces presented carbon primarily as hydro-carbon (CAC, CAH) with lower levels of oxidized carbon forms. The CaP surface presented atomic percent values of 38, 42, 11, and 7 for C, O, Ca, and P, respectively, and the CaPPlasma presented increases in O, Ca, and P atomic percent levels at 53, 12, and 13, respectively, in addition to a decrease in C content at 18 atomic percent. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC and BAFO were observed for CaPPlasma treated surfaces. Surface elemental chemistry was modified by the Ar-based NTP. Ar-based NTP improved bone formation around plateau-root form implants at 3 weeks compared with CaP treatment alone. © 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metallic biomaterials are used to reinforce or to restore the form and function of hard tissues. Implants and prosthesis are used to replace shoulders, knees, hips and teeth. When these materials are inserted in bone several biological reactions happen. This process can be associated to surface properties (topography, roughness and surface energy). In this work, the influence of biomimetic surface treatment in the osseointegration of Ti-30Ta dental implants was evaluated. Ingots were obtained from titanium and tantalum by using an arc-melting furnace. They were submitted to heat treatment at 1,100°C for 1 h, cooled in water and cold worked by swaging. Then, screw-shaped implants (2.0 mm diameter by 2.5 mm length) were manufactured and they were implanted in a rat's femur. Animals were divided into two groups: untreated (control group) and treated (biomimetic surface treatment). They were sacrificed 30 days after implantation. For histological analysis, implants with surrounding tissue were removed and immersed in formaldehyde. Samples were embedded in polymethyl methacrylate and after polymerization, cut with a saw, polished and mounted on glass slides. The results obtained suggest that biomimetic surface treatment was able to promote an increase osseointegration on the surface of dental implants. © Springer-Verlag Berlin Heidelberg 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rehabilitation with oral implants is, without any doubt, a consecrated technique. But often we face situations of high bone atrophy where the conventional installation of dental implants is not possible. The posterior mandible, when severely resorbed, generally requires complex techniques to be rehabilitated with implants, such as the lateralization of the inferior alveolar nerve. As an option for these cases, this paper proposes the use of short implants for the rehabilitation of severely resorbed posterior mandible. Copyright © 2013 by Mutaz B. Habal, MD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to evaluate mechanical behavior of implants inserted in three substrates, by measuring the pullout strength and the relative stiffness. 32 implants (Master Porous-Conexao, cylindrical, external hexagon, and surface treatment) were divided into 4 groups (n = 8): pig rib bone, polyurethane Synbone, polyurethane Nacional 40 PCF, and pinus wood. Implants were installed with the exact distance of 5 mm of another implant. The insertion torque (N·cm) was quantified using the digital Kratos torque meter and the pullout test (N) was performed by an axial traction force toward the long axis of the implant (2 min/mm) through mount implant devices attached to a piece adapted to a load cell of 200 Kg of a universal testing machine (Emic DL10000). Data of insertion torque and maximum pullout force were submitted to one-way ANOVA and Bonferroni tests (α = 0.05). Polyurethane Nacional 40 PCF and pinus wood showed the highest values of insertion torque and pullout force, with significant statistical difference (P < 0.05) with other groups. The analysis showed stiffness materials with the highest values for primary stability. © 2013 Nathalia Ferraz Oliscovicz et al.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the correlations between clinical-radiographical aspects and histomorphometric-molecular parameters of endosseous dental implant sites in humans. Material and methods: The study sample consisted of bone implant sites from the jawbones of 32 volunteers, which were classified according to two different systems: (1) based only on periapical and panoramic images (PP); (2) as proposed by Lekholm & Zarb (L&Z). Bone biopsies were removed using trephine during the first drilling for implant placement. Samples were stained with haematoxylin-eosin (HE), and histomorphometric analysis was performed to obtain the following parameters: trabecular thickness (Tb.Th), trabecular number, bone volume density (BV/TV), bone specific surface (BS/BV), bone surface density and trabecular separation (Tb.Sp). In addition, immunohistochemistry analysis was performed on bone tissue samples for the proteins, Receptor activator of nuclear factor kappa-B (RANK), RANK ligand (RANKL), osteoprotegerin (OPG) and Osteocalcin (OC). Also, the determination of the relative levels of gene expression was performed using Reverse transcription-real-time Polymerase Chain Reaction (RT-PCR). Results: PP and L&Z classification systems revealed a moderate correlation with BV/TV, BS/BV, Tb.Th and Tb.Sp. L&Z's system identified differences among bone types when BV/TV, BS/BV, Tb.Th and Tb.Sp were compared. A weak correlation between PP/L&Z classifications and the expression of bone metabolism regulators (RANK, RANKL, OPG e OC) was found. The analysis of mRNA expression showed no difference between the bone types evaluated. Conclusions: Our results suggest that PP and L&Z subjective bone-type classification systems are related to histomorphometric aspects. These data may contribute to the validation of these classifications. Bone remodelling regulatory molecules do not seem to influence morphological aspects of the jawbone © 2011 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dentists are often faced with extensively resorbed mandibular ridges with shallow buccal vestibule and high insertion of the mentalis muscle in relation to the crest of the ridge, causing the displacement of the prosthesis. Vestibuloplasty techniques aim at eliminating the muscle insertions, reposition the mucosa, and increase the area chapeável, giving more stability to the prosthesis. Among the techniques to deepen the vestibule are submucosal vestibuloplasties by secondary epithelialization and with mucosal and skin grafts. We will discuss vestibuloplasty by secondary epithelialization with emphasis on the so-called modified Kazanjian technique. This technique provides an appropriate result and does not require hospitalization, additional surgery at the donor, or prolonged periods without the use of prosthesis. © 2013 by Mutaz B. Habal, MD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Application of recombinant human bone morphogenetic protein 2 (rhBMP-2) to implant surfaces has been of great interest due to its osteoinductive potential. However, the optimal coating methodology has not been clarified. The objective of the study was to determine whether the application of rhBMP-2 onto plasma-sprayed hydroxyapatite implant surfaces by immersion in protein solution before implant installation would result in significantly improved bone apposition. Using a sheep iliac model, titanium (Ti) and plasma-sprayed calcium-phosphate (PSCaP)-coated implants uncoated and coated with rhBMP-2 were assessed for their osteogenic effects in the peri-implant area over time in terms of osseointegration and de novo bone formation. After 3 and 6 weeks postoperatively, the samples were retrieved and were subjected to bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) evaluation. When rhBMP-2 was applied to the PSCaP surface, significant increases in BIC and BAFO were observed at 3 weeks in vivo, whereas when adsorbed directly onto the titanium implant surface, rhBMP-2 did not as effectively improve the bone response (although significantly higher than control Ti). The outcomes of the present study suggested that the combination of plasma-sprayed calcium-phosphate surface and rhBMP-2 coating significantly enhanced osseointegration, which validated the postulated hypothesis. © 2013 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tribocorrosion plays an important role in the lifetime of metallic implants. Once implanted, biomaterials are subjected to micro-movements in aggressive biological fluids. Titanium is widely used as an implant material because it spontaneously forms a compact and protective nanometric thick oxide layer, mainly TiO2, in ambient air. That layer provides good corrosion resistance, and very low toxicity, but its low wear resistance is a concern. In this work, an anodizing treatment was performed on commercial pure titanium to form a homogeneous thick oxide surface layer in order to provide bioactivity and improve the biological, chemical and mechanical properties. Anodizing was performed in an electrolyte containing β-glycerophosphate and calcium acetate. The influence of the calcium acetate content on the tribocorrosion behaviour of the anodized material was studied. The concentration of calcium acetate in the electrolyte was found to largely affect the crystallographic structure of the resulting oxide layer. Better tribocorrosion behaviour was noticed on increasing the calcium acetate concentration. © 2013 IOP Publishing Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the release of bone markers during osseointegration of immediately loaded and nonloaded implants. Forty patients who were indicated for rehabilitation with dental implants randomly received either implant and prosthesis placement within 72 hours (group IM) or implant insertion and no prosthesis placement (group NL). Peri-implant crevicular fluid was collected immediately after implant insertion and 7, 15, 30, 60, 90, and 120 days after surgery and levels of osteoprotegerin, transforming growth factors, osteocalcin, osteopontin, and parathyroid hormone were evaluated using Luminex assay. Bleeding index and peri-implantar sulcus depth were also evaluated. The data were compared using statistical tests ( = 5%). No statistical difference was found regarding demographic and clinical parameters (p > .05). Transforming growth factors, osteoprotegerin, osteopontin, and parathyroid hormone presented an earlier release peak in group IM than in NL group (p < .05). Osteocalcin achieved higher levels in group IM versus group NL between 7 and 30 days of evaluation (p < .05). It may be concluded that earlier loading positively modulates bone mediators release around immediately loaded implants when compared with nonloaded dental implants (ClinicalTrials.gov NCT01909999).