993 resultados para Deep tissue


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The deep transverse metatarsal ligaments (DTML) play an important role in stabilizing the metatarsal bones and manipulating foot transverse arch deformation. However, the biomechanical research about DTML in the foot maneuver is quite few. Due to the difficulties and lack of better measurement technology for these ligaments experimental monitor, the load transfer mechanism and internal stress state also hadn't been well addressed. The purpose of this study was to develop a detailing foot finite element model including DTML tissues, to investigate the mechanical response of DTML during the landing condition. The DTML was considered as hyperelastic material model was used to represent the nonlinear and nearly incompressible nature of the ligament tissue. From the simulation results, it is clearly to find that the peak maiximal principal stress of DTML was between the third and fourth metatarsals. Meanwhile, it seems the DTML in the middle position experienced higher tension than the sides DTML.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surgery is one of the most effective and widely used procedures in treating human cancers, but a major problem is that the surgeon often fails to remove the entire tumor, leaving behind tumor-positive margins, metastatic lymph nodes, and/or satellite tumor nodules. Here we report the use of a hand-held spectroscopic pen device (termed SpectroPen) and near-infrared contrast agents for intraoperative detection of malignant tumors, based on wavelength-resolved measurements of fluorescence and surface-enhanced Raman scattering (SERS) signals. The SpectroPen utilizes a near-infrared diode laser (emitting at 785 nm) coupled to a compact head unit for light excitation and collection. This pen-shaped device effectively removes silica Raman peaks from the fiber optics and attenuates the reflected excitation light, allowing sensitive analysis of both fluorescence and Raman signals. Its overall performance has been evaluated by using a fluorescent contrast agent (indocyanine green, or ICG) as well as a surface-enhanced Raman scattering (SERS) contrast agent (pegylated colloidal gold). Under in vitro conditions, the detection limits are approximately 2-5 × 10(-11) M for the indocyanine dye and 0.5-1 × 10(-13) M for the SERS contrast agent. Ex vivo tissue penetration data show attenuated but resolvable fluorescence and Raman signals when the contrast agents are buried 5-10 mm deep in fresh animal tissues. In vivo studies using mice bearing bioluminescent 4T1 breast tumors further demonstrate that the tumor borders can be precisely detected preoperatively and intraoperatively, and that the contrast signals are strongly correlated with tumor bioluminescence. After surgery, the SpectroPen device permits further evaluation of both positive and negative tumor margins around the surgical cavity, raising new possibilities for real-time tumor detection and image-guided surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. Aminolevulinic acid (5-ALA) diffusion through both keratinised and non-keratinised tissue, used as a model tissue substrates, was evaluated, together with the depth of permeation and the concentration achieved following delivery from bioadhesive patch and proprietary cream formulations. Materials and Methods. Moisture-activated, bioadhesive patches loaded with 5-ALA at concentrations of 19.0, 38.0 and 50.0 mg cm(-2) and an o/w cream (20% w/w 5-ALA) were radiolabelled with C14 5-ALA and applied to excised human vaginal tissue and porcine skin. After 1, 2 and 4 h, tissue was sectioned in two orientations and the 5-ALA concentration at specific depths determined using autoradiography and liquid scintillation counting (LSC). Results. The stratum corneum was a significant barrier to 5-ALA permeation, with concentrations in tissue dependent on application time and drug loading. 5-ALA was detected at 6 mm using autoradiography after 2 h, with LSC showing phototoxic concentrations at 2.375 mm after 4 h of application. Inclusion of oleic acid and dimethyl sulphoxide in bioadhesive patches increased 5-ALA significantly in neonate porcine tissue, but only for patches cast from blends containing 5% w/w oleic acid. Conclusions. The bioadhesive patch described delivered 5-ALA to depths of at least 2.5 mm in tissue types indicative of vulval skin, suggesting that photodynamic therapy of deep vulval intraepithelial neoplasia is feasible using this means of bioadhesive 5-ALA delivery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Epibiotic foraminifers selectively settle on the most food-rich area of the host substrate, even when the species acts as a facultative ectoparasite in later life stages. In 398 specimens examined of the deep-sea chiton Leptochiton arcticus from Iceland, 46% show evidence of infestation by foraminifers, with many showing extensive shell damage from present and past bioeroding epibionts. Disturbances to the inner layer of the host shell are indicative of parasitism, as evidenced both by wound healing calcification and protrusions of the foraminiferan tubules. The epibionts employ different feeding strategies at different stages of their life cycle, taking advantage of nutrient availability from the posterior respiration currents and excrement of the chitons as juveniles, and feeding parasitically as adults. Epibiont persistence on individual hosts-through successive generations, or long-term continuous bioerosion by epibionts-allow larger adult parasitic foraminifers of Hyrrokkin sarcophaga to penetrate the thick tail valve of a chiton and feed parasitically on the host tissue. The proportion of chitons infested increases with host size, indicating that epibionts are accumulated through a chiton's life, seemingly without major detriment to host survivorship.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tese de Doutoramento, Ciências do Mar, especialidade de Biologia Marinha, 18 de Dezembro de 2015, Universidade dos Açores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deep brain stimulation has emerged as an effective method to treat certain medical conditions. Electrical charges are injected into the target tissue through a conducting electrode exciting the tissue. A variety of DBS devices have been developed based on different operation principles. Majority of these devices, however, employ complex circuitry and are bulky. In clinical trials, laboratory animals need to freely move around and perform activities whilst receiving brain stimulation for days. This paper presents a simple lightweight head mountable deep brain stimulation device that can be carried by the animal during the course of a clinical trial. The device produces continuous current pulses of specific characteristics. It employs passive charge balancing to minimize undesirable effects on the target tissue. The device is constructed and its performance tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A compact meandered three-layer stacked circular planar inverted-F antenna is designed and simulated at the UHF band (902.75 – 927.25 MHz) for passive deep brain stimulation implants. The UHF band is used because it offers small antenna size, and high data rate. The top and middle radiating layers are meandered, and low cost substrate and superstrate materials are used to limit the radius and height of the antenna to 5 mm and 1.64 mm, respectively. A dielectric substrate of FR-4 of εr= 4.7 and δ= 0.018, and a biocompatible superstrate of silicone of er= 3.7 and d= 0.003 with thickness of 0.2 mm are used in the design. The resonance frequency of the proposed antenna is 918 MHz with a bandwidth of 24 MHz at return loss of −10 dB in free space. The antenna parameter such as 3D gain pattern of the designed antenna within a skin-tissue model is evaluated by using the finite element method. The compactness, wide bandwidth, round shape, and stable characteristics in skin make this antenna suitable for DBS. The feasibility of the wireless power transmission to the implant in the human head is also examined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deep brain stimulation has emerged as an effective medical procedure that has therapeutic efficacy in a number of neuropsychiatric disorders. Preclinical research involving laboratory animals is being conducted to study the principles, mechanisms, and therapeutic effects of deep brain stimulation. A bottleneck is, however, the lack of deep brain stimulation devices that enable long term brain stimulation in freely moving laboratory animals. Most of the existing devices employ complex circuitry, and are thus bulky. These devices are usually connected to the electrode that is implanted into the animal brain using long fixed wires. In long term behavioral trials, however, laboratory animals often need to continuously receive brain stimulation for days without interruption, which is difficult with existing technology. This paper presents a low power and lightweight portable microdeep brain stimulation device for laboratory animals. Three different configurations of the device are presented as follows: 1) single piece head mountable; 2) single piece back mountable; and 3) two piece back mountable. The device can be easily carried by the animal during the course of a clinical trial, and that it can produce non-stop stimulation current pulses of desired characteristics for over 12 days on a single battery. It employs passive charge balancing to minimize undesirable effects on the target tissue. The results of bench, in-vitro, and in-vivo tests to evaluate the performance of the device are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this article is to report the use of the subepithelial connective tissue graft technique combined with the coronally positioned flap on a composite resin-restored root surface to treat Miller Class I gingival recessions associated with deep cervical abrasions in maxillary central incisors. Clinical measurements, including gingival recession height, probing depth, and bleeding on probing (BoP), were recorded during the preoperative clinical examination and at 2, 6, 12, and 24 months postoperatively. During the follow-up periods, no periodontal pockets or BoP were observed. The periodontal tissue of the teeth presented normal color, texture, and contouring. In addition, it was observed that creeping attachment had occurred on the restoration. This case report shows that this form of treatment can be highly effective and predictable in resolving gingival recession associated with a deep cervical abrasion. (Quintessence Int 2012;43:597-602)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. To evaluate the response of the pulpo-dentin complex following application of a resin-modified glass-ionomer cement or an adhesive system in deep cavities performed in human teeth.Methods. Deep class V cavities were prepared on the buccal surface of 26 premolars. In Group I the cavity walls (dentin) and enamel were conditioned with 32% phosphoric acid and the dentin adhesive system One Step (Bisco, Inc., Itasca, IL, USA) was applied. In Groups 2 and 3, before total etching and application of bonding agent, the cavity floor was lined with the resin-modified glass-ionomer cement-Vitrebond (3M ESPE Dental Products Division, St. Paul, MN, USA) or the calcium hydroxide cement-Dycal (control group, Dentsply, Mildford, DE, USA), respectively. The cavities were restored using light-cured Z-100 composite resin (3M ESPE). The teeth were extracted between 5 and 30 days and prepared for microscopic assessment. Serial sections were stained with H/E, Masson's trichrome, and Brown and Brenn techniques.Results. In Group 1, the inflammatory response was more evident than in Groups 2 and 3. Diffusion of dental material components across dentinal tubules was observed only in Group 1, in which the intensity of the pulp response increased as the remaining dentin thickness decreased. Bacteria were evidenced in the lateral walls of two samples (Group 2) which exhibited no inflammatory response or tissue disorganization.Conclusions. Based on the experimental conditions, it was concluded total acid etching followed by application of One Step bonding agent cannot be recommended as adequate procedures. In this clinical condition the cavity walls should be lined with a biocompatible dental material, such as Vitrebond or Dycal. 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. The aim of this in vivo study was to evaluate the human dental pulp response when a one-bottle adhesive system was applied on etched or unetched deep dentine.Methods. Eighteen class V deep cavity preparations were divided in three groups: group 1-total etching + two coats of single bond (SB) + composite resin (Z-100); group 2-enamel etching + two coats of SB + Z-100, group 3-cavity floor lined with a calcium hydroxide liner (Dycal) + acid-etching of enamel and lateral walls + two coats of SB + Z-100. Two teeth were used as intact control group. After 30 days the teeth were extracted and processed through H and E, Masson's trichrome and Brown and Brenn staining techniques.Results. Moderate inflammatory response, disorganization of pulp tissue, as well as, deposition of thin layer of reactionary dentin were observed in group 1 teeth in which the remaining dentin thickness (RDT) was less than 300 mum. These histological findings appear to be related to long resin tags formation and bonding agent diffusion through dentinal tubules. In group 2, slight inflammatory response was observed only in one tooth in which the RDT was 162 mum. In group 3, all the teeth showed normal histological characteristics which were similar to the intact control group. Presence of bacteria was not correlated with the intensity of pulpal response. The patients reported no symptoms during the experiment. Radiographic evaluation showed no periapical pathology for any of the teeth,Significance and conclusions. Acid-etched deep dentin (RDT less than 300 mum) lined with SB causes more intense pulpal response than unetched deep dentin. Based on the results observed in the present study and the conditions in which it was carried out, we recommend the application of a biocompatible liner before etching deep dentin and applying SB. (C) 2002 Academy of Dental Materials. Published by Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of lysine amino acid supplementation on the growth characteristics and morphological pattern of skeletal muscle tissue in Nile tilapia Oreochromis niloticus larvae was evaluated. There were four treatments (T) with increasing levels of lysine supplement (T1 = 0.0%: T2 =1.1%; T3 = 1.7%; T4 = 4.0%) and one treatment with a commercial diet (T5). In all treatments, morphological and histochemical muscle tissue analyses were similar. Two distinct layers were identified: a superficial red layer, more developed in the lateral line region, formed by fibres with intense to moderate NADH-TR reaction and strong acid-stable mATPase activity, and a deep white one, most of the Muscle mass, formed by fibres with weak NADH-TR reaction and strong alkali-stable mATPase activity. There was an intermediate layer between these two layers with fibres exhibiting either weak acid-stable or acid-labile mATPase activity. Body mass increase was significantly higher in T5 than in the lysine treatments (T1-T4). There was no difference in number and diameters of muscle fibres between lysine treatments. In T5, muscle fibre diameter and number were higher. The frequency of red fibres with diameters <= 8 mu m was higher in the lysine treatments, and with diameters between 16 and 24 mu m, was higher in T5. Most white fibre diameters in T5 were significantly larger than 24 mu m and in T1-T4 were between 8 and 16 mu m. Cell proliferation was higher in the lysine treatments and muscle growth in T5 was mainly by fibre hypertrophy. (c) 2005 the Fisheries Society of the British

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are several methods for identifying carious dentinal tissue aiming to avoid removal of healthy dentinal tissue. Objectives: The purpose of this study was to test different methods for the detection of carious dentinal tissue regarding the amount of carious tissue removed and the remaining dentin microhardness after caries removal. Material and methods: The dentin surfaces of 20 bovine teeth were exposed and half of the surface was protected with nail polish. Cariogenic challenge was performed by immersion in a demineralizing solution for 14 days. After transverse cross-section of the crown, the specimens were divided into four groups (n=10), according to the method used to identify and remove the carious tissue: "Papacarie", Caries-detector dye, DIAGNOdent and Tactile method. After caries removal, the cross-sectional surface was included in acrylic resin and polished. In a microhardness tester, the removed dentin thickness and the Vickers microhardness of the following regions were evaluated: remaining dentin after caries removal and superficial and deep healthy dentin. Results: ANOVA and Tukey's test (alpha=0.05) were performed, except for DIAGNOdent, which did not detect the presence of caries. Results for removed dentin thickness were: "Papacarie" (424.7 +/- 105.0; a), Caries-detector dye (370.5 +/- 78.3; ab), Tactile method (322.8 +/- 51.5; bc). Results for the remaining dentin microhardness were: "Papacarie" (42.2 +/- 10.5; bc), Caries-detector dye (44.6 +/- 11.8; bc), Tactile method (24.3 +/- 9.0; d). Conclusions: DIAGNOdent did not detect the presence of carious tissue; Tactile method and "Papacarie" resulted in the least and the most dentinal thickness removal, respectively; Tactile method differed significantly from "Papacarie" and Caries-detector dye in terms of the remaining dentin microhardness, and Tactile method was the one which presented the lowest microhardness values.