912 resultados para DIAGNOSTIC IMAGING
Resumo:
UNLABELLED Gastrin-releasing peptide receptors (GRPrs) are overexpressed on a variety of human cancers, providing the opportunity for peptide receptor targeting via radiolabeled bombesin-based peptides. As part of our ongoing investigations into the development of improved GRPr antagonists, this study aimed at verifying whether and how N-terminal modulations improve the affinity and pharmacokinetics of radiolabeled GRPr antagonists. METHODS The potent GRPr antagonist MJ9, Pip-d-Phe-Gln-Trp-Ala-Val-Gly-His-Sta-Leu-NH(2) (Pip, 4-amino-1-carboxymethyl-piperidine), was conjugated to 1,4,7-triazacyclononane, 1-glutaric acid-4,7 acetic acid (NODAGA), and 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) and radiolabeled with (68)Ga and (64)Cu. The GRPr affinity of the corresponding metalloconjugates was determined using (125)I-Tyr(4)-BN as a radioligand. The labeling efficiency of (68)Ga(3+) was compared between NODAGA-MJ9 and NOTA-MJ9 in acetate buffer, at room temperature and at 95°C. The (68)Ga and (64)Cu conjugates were further evaluated in vivo in PC3 tumor xenografts by biodistribution and PET imaging studies. RESULTS The half maximum inhibitory concentrations of all the metalloconjugates are in the high picomolar-low nanomolar range, and these are the most affine-radiolabeled GRPr antagonists we have studied so far in our laboratory. NODAGA-MJ9 incorporates (68)Ga(3+) nearly quantitatively (>98%) at room temperature within 10 min and at much lower peptide concentrations (1.4 × 10(-6) M) than NOTA-MJ9, for which the labeling yield was approximately 45% under the same conditions and increased to 75% at 95°C for 5 min. Biodistribution studies showed high and specific tumor uptake, with a maximum of 23.3 ± 2.0 percentage injected activity per gram of tissue (%IA/g) for (68)Ga-NOTA-MJ9 and 16.7 ± 2.0 %IA/g for (68)Ga-NODAGA-MJ9 at 1 h after injection. The acquisition of PET images with the (64)Cu-MJ9 conjugates at later time points clearly showed the efficient clearance of the accumulated activity from the background already at 4 h after injection, whereas tumor uptake still remained high. The high pancreas uptake for all radiotracers at 1 h after injection was rapidly washed out, resulting in an increased tumor-to-pancreas ratio at later time points. CONCLUSION We have developed 2 GRPr antagonistic radioligands, which are improved in terms of binding affinity and overall biodistribution profile. Their promising in vivo pharmacokinetic performance may contribute to the improvement of the diagnostic imaging of tumors overexpressing GRPr.
Resumo:
Owing to the demand for genuine mozzarella, some 330 water buffaloes are being slaughtered every year in Switzerland albeit a stunning procedure meeting animal welfare and occupational safety requirements remains to be established. To provide a basis for improvements, we sized anatomical specifics in water buffaloes and cattle and we assessed brain lesions after stunning with captive bolts or handguns by diagnostic imaging. In water buffaloes and cattle, the median distance from the frontal skin surface to the inner bone table was 74.0 mm (56.0–100.0 mm) vs 36.6 mm (29.3–44.3 mm) and from skin to the thalamus 144.8 mm (117.1–172.0 mm) vs 102.0 (101.0–121.0 mm), respectively. Consequently, customary captive bolt stunners may be inadequate. Free bullets are potentially suitable for stunning buffaloes but involve occupational safety hazards. The results of the present study shall be used to develop a device allowing effective and safe stunning of water buffaloes.
Resumo:
Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. Methods: An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). Results: JAFROC analysis showed a significant difference (P < 0.0001) in lesion detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Conclusion: Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified.
Resumo:
This review will make familiar with new concepts in ovarian cancer and their impact on radiological practice. Disseminated peritoneal spread and ascites are typical of the most common (70–80 %) cancer type, highgrade serous ovarian cancer. Other cancer subtypes differ in origin, precursors, and imaging features. Expert sonography allows excellent risk assessment in adnexal masses. Owing to its high specificity, complementary MRI improves characterization of indeterminate lesions. Major changes in the new FIGO staging classification include fusion of fallopian tube and primary ovarian cancer and the subcategory stage IIIA1 for retroperitoneal lymph node metastases only. Inguinal lymph nodes, cardiophrenic lymph nodes, and umbilical metastases are classified as distant metastases (stage IVB). In multidisciplinary conferences (MDC), CT has been used to predict the success of cytoreductive surgery. Resectability criteria have to be specified and agreed on in MDC. Limitations in detection of metastases may be overcome using advanced MRI techniques.
Comparison of standard image segmentation methods for segmentation of brain tumors from 2D MR images
Resumo:
In the analysis of medical images for computer-aided diagnosis and therapy, segmentation is often required as a preliminary step. Medical image segmentation is a complex and challenging task due to the complex nature of the images. The brain has a particularly complicated structure and its precise segmentation is very important for detecting tumors, edema, and necrotic tissues in order to prescribe appropriate therapy. Magnetic Resonance Imaging is an important diagnostic imaging technique utilized for early detection of abnormal changes in tissues and organs. It possesses good contrast resolution for different tissues and is, thus, preferred over Computerized Tomography for brain study. Therefore, the majority of research in medical image segmentation concerns MR images. As the core juncture of this research a set of MR images have been segmented using standard image segmentation techniques to isolate a brain tumor from the other regions of the brain. Subsequently the resultant images from the different segmentation techniques were compared with each other and analyzed by professional radiologists to find the segmentation technique which is the most accurate. Experimental results show that the Otsu’s thresholding method is the most suitable image segmentation method to segment a brain tumor from a Magnetic Resonance Image.
Resumo:
This project was a preliminary step towards the development of novel methods for early stage cancer diagnosis and treatment. Diagnostic imaging agents with high Raman signal enhancement were developed based on tailored assemblies of gold nanoparticles, which demonstrated potential for non-invasive detection from deep under the skin surface. Specifically designed polymers were employed to assemble gold nanoparticles into controlled morphologies including dimers, nanochains, nanoplates, globular and core-satellite nanostructures. Our findings suggest that the Raman enhancement is strongly dependent on assembly morphology and can be tuned to adapt to the requirements of the diagnostic agent.
Resumo:
Diagnosis of articular cartilage pathology in the early disease stages using current clinical diagnostic imaging modalities is challenging, particularly because there is often no visible change in the tissue surface and matrix content, such as proteoglycans (PG). In this study, we propose the use of near infrared (NIR) spectroscopy to spatially map PG content in articular cartilage. The relationship between NIR spectra and reference data (PG content) obtained from histology of normal and artificially induced PG-depleted cartilage samples was investigated using principal component (PC) and partial least squares (PLS) regression analyses. Significant correlation was obtained between both data (R2 = 91.40%, p<0.0001). The resulting correlation was used to predict PG content from spectra acquired from whole joint sample, this was then employed to spatially map this component of cartilage across the intact sample. We conclude that NIR spectroscopy is a feasible tool for evaluating cartilage contents and mapping their distribution across mammalian joint
Resumo:
Context: Tumor-induced osteomalacia (TIO) is a rarely diagnosed disorder presenting with bone pain, fractures, muscle weakness, and moderate-to-severe hypophosphatemia resulting from fibroblast growth factor 23-mediated renal phosphate wasting. Tumors secreting fibroblast growth factor 23 are often small and difficult to find with conventional imaging. Objective: We studied the utility of 68Ga-DOTA-octreotate (DOTATATE) somatostatin receptor positron emission tomography (PET)/computed tomography (CT) imaging in the diagnosis of TIO. Design and Setting: A multicenter case series was conducted at tertiary referral hospitals. Patients and Methods: Six patients with TIO diagnosed between 2003 and 2012 in Australia were referred for DOTATATE PET imaging. We reviewed the clinical history, biochemistry, imaging characteristics, histopathology, and clinical outcome of each patient. Results: Each case demonstrated delayed diagnosis despite severe symptoms. DOTATATE PET/CT imaging demonstrated high uptake and localized the tumor with confidence in each case. After surgical excision, there was resolution of clinical symptoms and serum phosphate, except in one patient who demonstrated residual disease on PET/CT. All tumors demonstrated high somatostatin receptor subtype 2 cell surface receptor expression using immunohistochemistry. Conclusions: In patients with TIO, DOTATATE PET/CT can successfully localize phosphaturic mesenchymal tumors and may be a practical first step in functional imaging for this disorder. Serum phosphate should be measured routinely in patients with unexplained muscle weakness, bone pain, or stress fractures to allow earlier diagnosis of TIO. - See more at: http://press.endocrine.org/doi/abs/10.1210/jc.2012-3642#sthash.eXD0CopL.dpuf
Resumo:
Bone stress injuries of the foot have been known for more than 150 years. For a century, their primary diagnostic imaging tool has been radiography. However, currently the golden standard for establishing the diagnosis of stress injuries is magnetic resonance imaging (MRI). Although the injury type has been fairly well documented in the earlier literature, little information is available on the healing of stress injuries located in e.g. the talus and calcaneus. The current study retrospectively evaluated the stress injuries of the foot and ankle treated at the Central Military Hospital over a period of eight years in patients who underwent MRI for stress injury of the foot. The imaging studies of the patients were reevaluated to determine the exact nature of the stress injury. Moreover, the hospital records of the patients were reviewed to determine the healing of stress injuries of the talus and calcaneus. Patients with a stress fracture in the talus were recalled for a follow-up examination and MRI scan one to six years after the initial injury to determine if the fracture had completely healed, clinically and radiologically. The bone stress injuries of the foot were found to affect more than one bone in a majority of the cases. The talus and the calcaneus were the bones most commonly affected. In the talus, the most common site for the injuries was the head of the bone, and in the calcaneus, the posterior part of the bone. The injuries in these bones were associated with injuries in the surrounding bones. Stress injuries in the calcaneus seemed to heal well. No complications were seen in the primary healing process. The patients were, however, sometimes compelled to refrain from physical training for up to months. In the talus, minor degenerative findings of the articular surface were seen in half of the patients who participated in a follow-up MRI scan and radiographs taken one to six years after the initial injury. Half of the patients also reported minor exercise related symptoms in the follow-up. The symptoms were, however, not noticeable in everyday life.
Resumo:
Purpose: The authors aim at developing a pseudo-time, sub-optimal stochastic filtering approach based on a derivative free variant of the ensemble Kalman filter (EnKF) for solving the inverse problem of diffuse optical tomography (DOT) while making use of a shape based reconstruction strategy that enables representing a cross section of an inhomogeneous tumor boundary by a general closed curve. Methods: The optical parameter fields to be recovered are approximated via an expansion based on the circular harmonics (CH) (Fourier basis functions) and the EnKF is used to recover the coefficients in the expansion with both simulated and experimentally obtained photon fluence data on phantoms with inhomogeneous inclusions. The process and measurement equations in the pseudo-dynamic EnKF (PD-EnKF) presently yield a parsimonious representation of the filter variables, which consist of only the Fourier coefficients and the constant scalar parameter value within the inclusion. Using fictitious, low-intensity Wiener noise processes in suitably constructed ``measurement'' equations, the filter variables are treated as pseudo-stochastic processes so that their recovery within a stochastic filtering framework is made possible. Results: In our numerical simulations, we have considered both elliptical inclusions (two inhomogeneities) and those with more complex shapes (such as an annular ring and a dumbbell) in 2-D objects which are cross-sections of a cylinder with background absorption and (reduced) scattering coefficient chosen as mu(b)(a)=0.01mm(-1) and mu('b)(s)=1.0mm(-1), respectively. We also assume mu(a) = 0.02 mm(-1) within the inhomogeneity (for the single inhomogeneity case) and mu(a) = 0.02 and 0.03 mm(-1) (for the two inhomogeneities case). The reconstruction results by the PD-EnKF are shown to be consistently superior to those through a deterministic and explicitly regularized Gauss-Newton algorithm. We have also estimated the unknown mu(a) from experimentally gathered fluence data and verified the reconstruction by matching the experimental data with the computed one. Conclusions: The PD-EnKF, which exhibits little sensitivity against variations in the fictitiously introduced noise processes, is also proven to be accurate and robust in recovering a spatial map of the absorption coefficient from DOT data. With the help of shape based representation of the inhomogeneities and an appropriate scaling of the CH expansion coefficients representing the boundary, we have been able to recover inhomogeneities representative of the shape of malignancies in medical diagnostic imaging. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3679855]
Resumo:
Electrical Impedance Tomography (EIT) is a computerized medical imaging technique which reconstructs the electrical impedance images of a domain under test from the boundary voltage-current data measured by an EIT electronic instrumentation using an image reconstruction algorithm. Being a computed tomography technique, EIT injects a constant current to the patient's body through the surface electrodes surrounding the domain to be imaged (Omega) and tries to calculate the spatial distribution of electrical conductivity or resistivity of the closed conducting domain using the potentials developed at the domain boundary (partial derivative Omega). Practical phantoms are essentially required to study, test and calibrate a medical EIT system for certifying the system before applying it on patients for diagnostic imaging. Therefore, the EIT phantoms are essentially required to generate boundary data for studying and assessing the instrumentation and inverse solvers a in EIT. For proper assessment of an inverse solver of a 2D EIT system, a perfect 2D practical phantom is required. As the practical phantoms are the assemblies of the objects with 3D geometries, the developing of a practical 2D-phantom is a great challenge and therefore, the boundary data generated from the practical phantoms with 3D geometry are found inappropriate for assessing a 2D inverse solver. Furthermore, the boundary data errors contributed by the instrumentation are also difficult to separate from the errors developed by the 3D phantoms. Hence, the errorless boundary data are found essential to assess the inverse solver in 2D EIT. In this direction, a MatLAB-based Virtual Phantom for 2D EIT (MatVP2DEIT) is developed to generate accurate boundary data for assessing the 2D-EIT inverse solvers and the image reconstruction accuracy. MatVP2DEIT is a MatLAB-based computer program which simulates a phantom in computer and generates the boundary potential data as the outputs by using the combinations of different phantom parameters as the inputs to the program. Phantom diameter, inhomogeneity geometry (shape, size and position), number of inhomogeneities, applied current magnitude, background resistivity, inhomogeneity resistivity all are set as the phantom variables which are provided as the input parameters to the MatVP2DEIT for simulating different phantom configurations. A constant current injection is simulated at the phantom boundary with different current injection protocols and boundary potential data are calculated. Boundary data sets are generated with different phantom configurations obtained with the different combinations of the phantom variables and the resistivity images are reconstructed using EIDORS. Boundary data of the virtual phantoms, containing inhomogeneities with complex geometries, are also generated for different current injection patterns using MatVP2DEIT and the resistivity imaging is studied. The effect of regularization method on the image reconstruction is also studied with the data generated by MatVP2DEIT. Resistivity images are evaluated by studying the resistivity parameters and contrast parameters estimated from the elemental resistivity profiles of the reconstructed phantom domain. Results show that the MatVP2DEIT generates accurate boundary data for different types of single or multiple objects which are efficient and accurate enough to reconstruct the resistivity images in EIDORS. The spatial resolution studies show that, the resistivity imaging conducted with the boundary data generated by MatVP2DEIT with 2048 elements, can reconstruct two circular inhomogeneities placed with a minimum distance (boundary to boundary) of 2 mm. It is also observed that, in MatVP2DEIT with 2048 elements, the boundary data generated for a phantom with a circular inhomogeneity of a diameter less than 7% of that of the phantom domain can produce resistivity images in EIDORS with a 1968 element mesh. Results also show that the MatVP2DEIT accurately generates the boundary data for neighbouring, opposite reference and trigonometric current patterns which are very suitable for resistivity reconstruction studies. MatVP2DEIT generated data are also found suitable for studying the effect of the different regularization methods on reconstruction process. Comparing the reconstructed image with an original geometry made in MatVP2DEIT, it would be easier to study the resistivity imaging procedures as well as the inverse solver performance. Using the proposed MatVP2DEIT software with modified domains, the cross sectional anatomy of a number of body parts can be simulated in PC and the impedance image reconstruction of human anatomy can be studied.
Resumo:
Imagens de tomografia computadorizada (TC) permitem a visualização, sem distorções ou sobreposições, do complexo maxilo-facial, principalmente do osso alveolar. Estudos demonstraram boa reprodutibilidade e precisão da mensuração da altura da borda alveolar, todavia a influência da espessura óssea ainda é pouco descrita. Através da comparação com a mensuração direta, o objetivo deste estudo foi avaliar a precisão, reprodutibilidade e a influência da espessura óssea, na mensuração da altura da borda alveolar em imagens volumétricas e imagens bidimensionais multiplanares em TC de feixe cônico (TCFC) e em TC espiral (TCE). Utilizando 10 mandíbulas secas de humanos, 57 dentes anteriores foram tomografados em equipamentos iCAT (Imaging Science International, Hatfield, PA, EUA) e Brilliance 64 canais (Philips Eletronics, Eindhoven, Holanda), ambos utilizando voxels de 0,25 mm. Através de imagens volumétricas (3D) e imagens bidimensionais (2D) de cortes multiplanares, foi comparada a mensuração da altura da borda alveolar dessas imagens com a mensuração direta nas mandíbulas, feita por vestibular e lingual, por três avaliadores, com o auxílio de um paquímetro, totalizando 114 bordas alveolares medidas. Alta reprodutibilidade intra-avaliador (0,999 a 0,902) e interavaliador (0,998 e 0,868) foi observada através do índice de correlação intraclasse (ICC). Observou-se alta correlação entre a mensuração direta e indireta da altura da borda alveolar em imagens 2D, sendo r=0,923** e 0,916**, e em imagens 3D, com r=0,929** e 0,954*, em TCFC e TCE, respectivamente. Imagens 2D superestimam a altura da borda alveolar em 0,32 e 0,49 mm e imagens 3D em 0,34 e 0,30 mm, em TCFC e TCE respectivamente. Quando o osso alveolar apresenta espessura de no mínimo 0,6 mm a média da diferença entre medidas diretas e indiretas é de 0,16 e 0,28 mm em imagens 2D e de 0,12 e 0,03 mm em imagens 3D para TCFC e TCE respectivamente, sendo que 95% do limite de concordância varia de -0,46 a 0,79 mm e -0,32 a 0,88 mm em imagens 2D, e de -0,64 a 0,67 mm e -0,57 a 0,62 mm em imagens 3D, para TCFC e TCE respectivamente. Quando o osso alveolar é mais fino do que 0,6 mm a TC é imprecisa, pois 95% do limite de concordância variou de -1,74 a 5,42 mm e -1,64 a 5,42 mm em imagens 2D, e de -3,70 a 4,28 mm e -3,49 a 4,25 mm em imagens 3D, para TCFC e TCE respectivamente. Conclui-se que a mensuração da altura da borda alveolar através de imagens tomográficas apresenta alta reprodutibilidade, sendo que quando a borda alveolar apresenta pelo menos 0,6 mm, a precisão da mensuração é alta, todavia quando esta espessura é menor do que 0,6 mm a técnica é imprecisa.
Resumo:
The activation parameters and the rate constants of the water-exchange reactions of Mn(III)TE-2-PyP(5+) (meso-tetrakis(N-ethylpyridinium-2-yl)porphyrin) as cationic, Mn(III)TnHex-2-PyP(5+) (meso-tetrakis(N-n-hexylpyridinium-2-yl)porphyrin) as sterically shielded cationic, and Mn(III)TSPP(3-) (meso-tetrakis(4-sulfonatophenyl)porphyrin) as anionic manganese(iii) porphyrins were determined from the temperature dependence of (17)O NMR relaxation rates. The rate constants at 298 K were obtained as 4.12 x 10(6) s(-1), 5.73 x 10(6) s(-1), and 2.74 x 10(7) s(-1), respectively. On the basis of the determined entropies of activation, an interchange-dissociative mechanism (I(d)) was proposed for the cationic complexes (DeltaS(double dagger) = approximately 0 J mol(-1) K(-1)) whereas a limiting dissociative mechanism (D) was proposed for Mn(III)TSPP(3-) complex (DeltaS(double dagger) = +79 J mol(-1) K(-1)). The obtained water exchange rate of Mn(III)TSPP(3-) corresponded well to the previously assumed value used by Koenig et al. (S. H. Koenig, R. D. Brown and M. Spiller, Magn. Reson. Med., 1987, 4, 52-260) to simulate the (1)H NMRD curves, therefore the measured value supports the theory developed for explaining the anomalous relaxivity of Mn(III)TSPP(3-) complex. A magnitude of the obtained water-exchange rate constants further confirms the suggested inner sphere electron transfer mechanism for the reactions of the two positively charged Mn(iii) porphyrins with the various biologically important oxygen and nitrogen reactive species. Due to the high biological and clinical relevance of the reactions that occur at the metal site of the studied Mn(iii) porphyrins, the determination of water exchange rates advanced our insight into their efficacy and mechanism of action, and in turn should impact their further development for both diagnostic (imaging) and therapeutic purposes.
Resumo:
BACKGROUND: Diagnostic imaging represents the fastest growing segment of costs in the US health system. This study investigated the cost-effectiveness of alternative diagnostic approaches to meniscus tears of the knee, a highly prevalent disease that traditionally relies on MRI as part of the diagnostic strategy. PURPOSE: To identify the most efficient strategy for the diagnosis of meniscus tears. STUDY DESIGN: Economic and decision analysis; Level of evidence, 1. METHODS: A simple-decision model run as a cost-utility analysis was constructed to assess the value added by MRI in various combinations with patient history and physical examination (H&P). The model examined traumatic and degenerative tears in 2 distinct settings: primary care and orthopaedic sports medicine clinic. Strategies were compared using the incremental cost-effectiveness ratio (ICER). RESULTS: In both practice settings, H&P alone was widely preferred for degenerative meniscus tears. Performing MRI to confirm a positive H&P was preferred for traumatic tears in both practice settings, with a willingness to pay of less than US$50,000 per quality-adjusted life-year. Performing an MRI for all patients was not preferred in any reasonable clinical scenario. The prevalence of a meniscus tear in a clinician's patient population was influential. For traumatic tears, MRI to confirm a positive H&P was preferred when prevalence was less than 46.7%, with H&P preferred above that. For degenerative tears, H&P was preferred until the prevalence reaches 74.2%, and then MRI to confirm a negative was the preferred strategy. In both settings, MRI to confirm positive physical examination led to more than a 10-fold lower rate of unnecessary surgeries than did any other strategy, while MRI to confirm negative physical examination led to a 2.08 and 2.26 higher rate than H&P alone in primary care and orthopaedic clinics, respectively. CONCLUSION: For all practitioners, H&P is the preferred strategy for the suspected degenerative meniscus tear. An MRI to confirm a positive H&P is preferred for traumatic tears for all practitioners. Consideration should be given to implementing alternative diagnostic strategies as well as enhancing provider education in physical examination skills to improve the reliability of H&P as a diagnostic test. CLINICAL RELEVANCE: Alternative diagnostic strategies that do not include the use of MRI may result in decreased health care costs without harm to the patient and could possibly reduce unnecessary procedures.
Resumo:
This article presents our most recent advances in synchronous fluorescence (SF) methodology for biomedical diagnostics. The SF method is characterized by simultaneously scanning both the excitation and emission wavelengths while keeping a constant wavelength interval between them. Compared to conventional fluorescence spectroscopy, the SF method simplifies the emission spectrum while enabling greater selectivity, and has been successfully used to detect subtle differences in the fluorescence emission signatures of biochemical species in cells and tissues. The SF method can be used in imaging to analyze dysplastic cells in vitro and tissue in vivo. Based on the SF method, here we demonstrate the feasibility of a time-resolved synchronous fluorescence (TRSF) method, which incorporates the intrinsic fluorescent decay characteristics of the fluorophores. Our prototype TRSF system has clearly shown its advantage in spectro-temporal separation of the fluorophores that were otherwise difficult to spectrally separate in SF spectroscopy. We envision that our previously-tested SF imaging and the newly-developed TRSF methods will combine their proven diagnostic potentials in cancer diagnosis to further improve the efficacy of SF-based biomedical diagnostics.