968 resultados para Crack closure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fracture mechanics tests were carried out for AerMet 100 in distilled water and NaCl (3.5 and 35 gl(-1)). The initiation period at higher values of the stress intensity factor indicated that load application in the stress corrosion cracking (SCC) environment is a necessary but not sufficient factor for SCC and that time is needed for some other factor (e.g., the local hydrogen concentration) to reach an appropriate value. The threshold stress intensity factor, K-ISSC, was found to increase with decreasing NaCl concentration. The plateau stress corrosion crack velocity was 2 x 10(-8) ms(-1) for NaCl (3.5 and 35 gl(-1)). The fracture mode was transgranular with small areas of an intergranular nature. (C) 1998 Chapman & Hall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first paper in a study on the influence of the environment on the crack tip strain field for AISI 4340. A stressing stage for the environmental scanning electron microscope (ESEM) was constructed which was capable of applying loads up to 60 kN to fracture-mechanics samples. The measurement of the crack tip strain field required preparation (by electron lithography or chemical etching) of a system of reference points spaced at similar to 5 mu m intervals on the sample surface, loading the sample inside an electron microscope, image processing procedures to measure the displacement at each reference point and calculation of the strain field. Two algorithms to calculate strain were evaluated. Possible sources of errors were calculation errors due to the algorithm, errors inherent in the image processing procedure and errors due to the limited precision of the displacement measurements. Estimation of the contribution of each source of error was performed. The technique allows measurement of the crack tip strain field over an area of 50 x 40 mu m with a strain precision better than +/- 0.02 at distances larger than 5 mu m from the crack tip. (C) 1999 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crack tip strain maps have been measured for AISI 4340 high strength steel. No significant creep was observed. The measured values of CTOD were greater than expected from the HRR model. Crack tip branching was observed in every experiment. The direction of crack branching was in the same direction as a major ridge'' of epsilon(yy) strain, which in turn was in the same direction as predicted by the HRR model. Furthermore, the measured magnitudes of the epsilon(y)y strain in this same direction were in general greater than the values predicted by the HRR model. This indicates more plasticity in the crack tip region than expected from the HRR model. This greater plasticity could be related to the larger than expected CTOD values. The following discrepancies between the measured strain fields for AISI 4340 and the HRR predictions are noteworthy: (1) The crack branching. (2) Values of CTOD significantly higher than predicted by HRR. (3) The major ridge'' of epsilon(yy) strain an angle of about 60 degrees with the direction of overall propagation of the fatigue precrack, in which the measured magnitudes of the epsilon(yy) strain were greater than the values predicted by the HRR model. (4) Asymmetric shape of the plastic zone as measured by the epsilon(yy) strain. (5) Values of shear strain gamma(xy) significantly higher than predicted by the HRR model. (C) 1999 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studied the influence of hydrogen and water vapour environments on the plastic behaviour in the vicinity of the crack tip for AISI 4340. Hydrogen and water vapour (at a pressure of 15 Torr) significantly increased the crack tip opening displacement. The crack tip strain distribution in 15 Torr hydrogen was significantly different to that measured in vacuum. In the presence of sufficient hydrogen, the plastic zone was larger, was elongated in the direction of crack propagation and moreover there was significant creep. These observations support the hydrogen enhanced localised plasticity model for hydrogen embrittlement in this steel. The strain distribution in the presence of water vapour also suggests that SCC in AISI 4340 occurs via the hydrogen enhanced localised plasticity mechanism. (C) 1999 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon monoxide is the chief killer in fires. Dangerous levels of CO can occur when reacting combustion gases are quenched by heat transfer, or by mixing of the fire plume in a cooled under- or overventilated upper layer. In this paper, carbon monoxide predictions for enclosure fires are modeled by the conditional moment closure (CMC) method and are compared with laboratory data. The modeled fire situation is a buoyant, turbulent, diffusion flame burning under a hood. The fire plume entrains fresh air, and the postflame gases are cooled considerably under the hood by conduction and radiation, emulating conditions which occur in enclosure fires and lead to the freezing of CO burnout. Predictions of CO in the cooled layer are presented in the context of a complete computational fluid dynamics solution of velocity, temperature, and major species concentrations. A range of underhood equivalence ratios, from rich to lean, are investigated. The CMC method predicts CO in very good agreement with data. In particular, CMC is able to correctly predict CO concentrations in lean cooled gases, showing its capability in conditions where reaction rates change considerably.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon monoxide, the chief killer in fires, and other species are modelled for a series of enclosure fires. The conditions emulate building fires where CO is formed in the rich, turbulent, nonpremixed flame and is transported frozen to lean mixtures by the ceiling jet which is cooled by radiation and dilution. Conditional moment closure modelling is used and computational domain minimisation criteria are developed which reduce the computational cost of this method. The predictions give good agreement for CO and other species in the lean, quenched-gas stream, holding promise that this method may provide a practical means of modelling real, three-dimensional fire situations. (c) 2005 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crack cocaine-dependent individuals (CCDI) present abnormalities in both social adjustment and decision making, but few studies have examined this association. This study investigated cognitive and social performance of 30 subjects (CCDI x controls); CCDI were abstinent for 2 weeks. We used the Social Adjustment Scale (SAS), Wisconsin Card Sorting Test (WCST), and Iowa Gambling Task (IGT). Disadvantageous choices on the IGT were associated with higher levels of social dysfunction in CCDI, suggesting the ecological validity of the IGT. Social dysfunction and decision making may be linked to the same underlying prefrontal dysfunction, but the nature of this association should be further investigated. (Am J Addict 2010;00: 1-9).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Spain, crack cocaine use is silently increasing. In Barcelona, an intentional sample was selected to describe the general characteristics of this consumption. Participants were submitted to an interview and data were analyzed through qualitative research procedures. Users are young males and of low socioeconomic status and formal education. The major pattern of use is compulsive. Illegal income activities are the choice for crack cocaine or money acquisition, increasing individual and social health costs. Polydrug use is a matter of concern. Although these findings can not be generalized, they should be considered for the development of public policies to adequately address crack cocaine users` needs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smoked cocaine (crack cocaine) causes several forms of injury to the respiratory tract, including asthma exacerbations, lung edema and hemorrhage, and nasal mucosal alterations. Few studies, however, have assessed respiratory tract pathology in habitual users of crack cocaine. Here, we describe the histological alterations in the respiratory tract of mice caused by chronic inhalation of crack cocaine. Twenty 2-month-old BALB/c mice were exposed to the smoke of 5 g crack cocaine in an inhalation chamber once a day for two months and compared to controls (n = 10). We then morphometrically analyzed nose and bronchiolar epithelial alterations, bronchiolar and alveolar macrophage cell density, alveolar hemosiderin content, and in addition determined the vasoconstriction index and the wall thickness of pulmonary arteries. The serum cocaine level was 212.5 ng/mL after a single inhalation. The mucus content of the nasal epithelium increased in crack-exposed animals, and the nasal and bronchial epithelium thickness decreased significantly. The alveolar hemosiderin content and the alveolar and bronchiolar macrophage cell density increased in animals exposed to crack. The vasoconstriction index increased in the pulmonary arteries of the exposed group. Chronic crack cocaine inhalation causes extensive histological changes along the entire respiratory tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To develop a new endoscopic approach to the correction of a myelomeningocele-like defect in fetal sheep. Methods: The fetuses of 9 pregnant ewes, with an average gestational age of 115 days, were subjected to a 3.0 x 2.0 cm removal of the skin over the lumbar spine, performed through hysterotomy. The uterus was closed, and three 5-mm endoscopic cannulas, without valve mechanisms, were inserted. In the pilot phase (2 animals), we initially worked exclusively in the amniotic fluid space. In the study phase, we partially withdrew the fetus from the amniotic fluid to completely expose its back. By simply allowing air to enter the amniotic cavity (without gas injection), a working space was created using a uterine lift device. The skin around the defect was dissected, and a biosynthetic cellulose material was applied to cover the area. A continuous suture of the skin was performed to completely hide the material. Results: The combined air/fluid space allowed the skin to be successfully closed in 6 out of 7 cases in the study phase. All fetuses were alive at the end of the procedures. Time to complete the endoscopic part of the procedure fell from 3 to 1 h by the end of this series. Premature birth occurred in 2 of the 4 cases allowed to continue with the pregnancy. Conclusion: A new gasless fetoscopic surgery technique was developed as an alternative to current techniques used for fetal endoscopic surgery. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the ability of a three-layer graft in the closuse of large fetal skin defects. Methods: Ovine fetuses underwent a large (4 x 3 cm) full-thickness skin defect over the lumbar region at 105 days` gestation (term = 140 days). A bilaminar artificial skin was placed over a cellulose interface to cover the defect (3-layer graft). The skin was partially reapproximated with a continuous nylon suture. Pregnancy was allowed to continue and the surgical site was submitted to histopathological analysis at different post-operative intervals. Results: Seven fetuses underwent surgery. One maternal/fetal death occurred, and the remaining 6 fetuses were analyzed. Artificial skin adherence to the wound edges was observed in cases that remained in utero for at least 15 days. Neoskin was present beneath the silicone layer of the bilaminar artificial skin. Conclusions: Our study shows that neoskin can develop in the fetus using a 3-layer graft, including epidermal growth beneath the silicone layer of the bilaminar skin graft. These findings suggest that the fetus is able to reepithelialise even large skin defects. Further experience is necessary to assess the quality of this repair.