864 resultados para Coronary angiography


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Atherosclerotic renal artery stenosis (RAS) and coronary artery disease (CAD) arise from the same multiple risk factors. The purpose of this study was to assess the frequency of previously undiagnosed CAD in patients with angiographically confirmed RAS, by conducting coronary arteriography in the same setting. of 57 consecutive patients referred for renal arteriography on clinical grounds during a 14-month period, 28 had no RAS and 6 had RAS, but previously documented CAD. of the remainder 23 patients. 17 (74%; CI 56%-92%) had both RAS and CAD (7 single vessel, 4 two-vessel, and 7 multivessel disease). The clinical characteristics, such as age, blood pressure (BP) levels, signs of heart failure, were no different between those with and without CAD, although the 4 diabetic patients, the 4 patients with fundoscopic findings of grade III retinopathy, 11 of 14 with peripheral arterial disease, and 7 of 8 patients with prior stroke belonged in the CAD group. None developed complications as a result of the two consecutive procedures. The data suggest that in patients with RAS the frequency of silent CAD is high and cannot be predicted on clinical grounds alone, therefore coronary angiography should be routinely recommended in the same setting.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Atherosclerotic coronary artery disease (CAD) is a multifactorial process that appears to be caused by the interaction of environmental risk factors with multiple predisposing genes. It is nowadays accepted that increased levels of DNA damage induced by xenobiotics play an important role in the early phases of atherogenesis. Therefore, in this study, we focus on determining whether genetic variations in xenobiotic-metabolizing [glutathione-S-transferase theta 1 (GSTT1), glutathione-S-transferase mu 1 (GSTM1), cytochrome P450 IIEI (CYP2E1)] and DNA repair [X-ray cross-complementing group 1 (XRCC1)] genes might be associated with increased risk for CAD. Methods: A case-control study was conducted with 400 individuals who underwent subjected to coronary angiography. A total of 299 were patients diagnosed with effective coronary atherosclerosis (case group; >20% obstructive lesion), and 101 (control group) were individuals diagnosed as negative for CAD (<20% obstructive lesions). The polymorphism identifications for GSTM1 and GSTT1, and for CYP2E1 and XRCC1 genes were performed by polymerase chain reaction (PCR) amplification and by PCR-RFLP, respectively. Results and conclusions: The XRCC1 homozygous wild-type genotype Arg/Arg for codon 399 was statistically less pronounced in the case subjects (21.4%) than in controls (38.5%); individuals with the variant XRCC1 genotype had a 2.3-fold increased risk for coronary atherosclerosis than individuals with the wild-type genotype (OR=2.3, 95% CI=1.13-4.69). Conversely, no association between GSTM1, GSTT1, and CYP2E1gene polymorphisms and coronary atherosclerosis was detected. The results provide evidence of the role of DNA damage and repair in cardiovascular disease. © 2011 Elsevier Inc. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background/aims: Cardiovascular diseases are major causes of mortality in chronic renal failure patients before and after renal transplantation. Among them, coronary disease presents a particular risk; however, risk predictors have been used to diagnose coronary heart disease. This study evaluated the frequency and importance of clinical predictors of coronary artery disease in chronic renal failure patients undergoing dialysis who were renal transplant candidates, and assessed a previously developed scoring system. Methods: Coronary angiographies conducted between March 2008 and April 2013 from 99 candidates for renal transplantation from two transplant centers in Sao Paulo state were analyzed for associations between significant coronary artery diseases (>= 70% stenosis in one or more epicardial coronary arteries or >= 50% in the left main coronary artery) and clinical parameters. Results: Univariate logistic regression analysis identified diabetes, angina, and/or previous infarction, clinical peripheral arterial disease and dyslipidemia as predictors of coronary artery disease. Multiple logistic regression analysis identified only diabetes and angina and/or previous infarction as independent predictors. Conclusion: The results corroborate previous studies demonstrating the importance of these factors when selecting patients for coronary angiography in clinical pretransplant evaluation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: The pathophysiology of acute coronary syndromes (ACS) after noncardiac surgery is not established yet. Thrombosis over a vulnerable plaque or decreased oxygen supply secondary to anemia or hypotension may be involved. The purpose of this study was to investigate the pathophysiology of ACS complicating noncardiac surgery. Methods: Clinical and angiographic data were prospectively recorded into a database for 120 consecutive patients that had an ACS after noncardiac surgery (PACS), for 120 patients with spontaneous ACS (SACS), and 240 patients with stable coronary artery disease (CAD). Coronary lesions with obstructions greater than 50% were classified based on two criteria: Ambrose's classification and complex morphology. The presence of Ambrose's type II or complex lesions were compared between the three groups. Results: We analyzed 1470 lesions in 480 patients. In PACS group, 45% of patients had Ambrose's type II lesions vs. 56.7% in SACS group and 16.4% in stable CAD group (P < 0.001). Both PACS and SACS patients had more complex lesions than patients in stable CAD group (56.7% vs. 79.2% vs. 31.8%, respectively; P < 0.001). Overall, the independent predictors of plaque rupture were being in the group PACS (P < 0.001, OR 2.86; CI, 1.82-4.52 for complex lesions and P < 0.001, OR 3.43; CI, 2.1-5.6 for Ambrose's type II lesions) or SACS (P < 0.001, OR 8.71; CI, 5.15-14.73 for complex lesions and P < 0.001, OR 5.99; CI, 3.66-9.81 for Ambrose's type II lesions). Conclusions: Nearly 50% of patients with perioperative ACS have evidence of coronary plaque rupture, characterizing a type 1 myocardial infarction. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

High serum phosphorus levels have been associated with mortality and cardiovascular events in patients with chronic kidney disease and in the general population. In addition, high phosphorus levels have been shown to induce vascular calcification and endothelial dysfunction in vitro. The aim of this study was to evaluate the relation of phosphorus and coronary calcification and atherosclerosis in the setting of normal renal function. This was a cross-sectional study involving 290 patients with suspected coronary artery disease and undergoing elective coronary angiography, with a creatinine clearance >60 ml/min/1.73 m(2). Coronary artery obstruction was assessed by the Friesinger score and coronary artery calcification by multislice computed tomography. Serum phosphorus was higher in patients with an Agatston score >10 than in those with an Agatston score <= 10 (3.63 +/- 0.55 versus 3.49 +/- 0.52 mg/dl; p = 0.02). In the patients with Friesinger scores >4, serum phosphorus was higher (3.6 +/- 0.5 versus 3.5 +/- 0.6 mg/dl, p = 0.04) and median intact fibroblast growth factor 23 was lower (40.3 pg/ml versus 45.7 pg/ml, p = 0.01). Each 0.1-mg/dl higher serum phosphate was associated with a 7.4% higher odds of having a Friesinger score >4 (p = 0.03) and a 6.1% greater risk of having an Agatston score >10 (p = 0.01). Fibroblast growth factor 23 was a negative predictor of Friesinger score ( p = 0.002). In conclusion, phosphorus is positively associated with coronary artery calcification and obstruction in patients with suspected coronary artery disease and preserved renal function.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To investigate the prognostic significance of ST-segment elevation (STE) in aVR associated with ST-segment depression (STD) in other leads in patients with non-STE acute coronary syndrome (NSTE-ACS). Background: In NSTE-ACS patients, STD has been extensively associated with severe coronary lesions and poor outcomes. The prognostic role of STE in aVR is uncertain. Methods: We enrolled 888 consecutive patients with NSTE-ACS. They were divided into two groups according to the presence or not on admission ECG of aVR STE≥ 1mm and STD (defined as high risk ECG pattern). The primary and secondary endpoints were: in-hospital cardiovascular (CV) death and the rate of culprit left main disease (LMD). Results: Patients with high risk ECG pattern (n=121) disclosed a worse clinical profile compared to patients (n=575) without [median GRACE (Global-Registry-of-Acute-Coronary-Events) risk score =142 vs. 182, respectively]. A total of 75% of patients underwent coronary angiography. The rate of in-hospital CV death was 3.9%. On multivariable analysis patients who had the high risk ECG pattern showed an increased risk of CV death (OR=2.88, 95%CI 1.05-7.88) and culprit LMD (OR=4.67,95%CI 1.86-11.74) compared to patients who had not. The prognostic significance of the high risk ECG pattern was maintained even after adjustment for the GRACE risk score (OR = 2.28, 95%CI:1.06-4.93 and OR = 4.13, 95%CI:2.13-8.01, for primary and secondary endpoint, respectively). Conclusions: STE in aVR associated with STD in other leads predicts in-hospital CV death and culprit LMD. This pattern may add prognostic information in patients with NSTE-ACS on top of recommended scoring system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: This study evaluates cardiovascular risk factors associated with progression of coronary artery disease (CAD) in patientswith silent ischemia followingmyocardial infarction. Hypothesis: Coronary artery disease only progresses slowly with comprehensive risk factor intervention. Methods: A total of 104 of 201 patients (51.7%) of the Swiss Interventional Study on Silent Ischemia Type II (SWISSI II) with baseline and follow-up coronary angiography were included. All patients received comprehensive cardiovascular risk factor intervention according to study protocol. Logistic regression was used to evaluate associationsbetween baseline cardiovascular risk factors and CAD progression. Results: The mean duration of follow-upwas 10.3 ± 2.4 years. At baseline, 77.9% of patients were smokers, 45.2% had hypertension, 73.1% had dyslipidemia, 7.7% had diabetes, and 48.1% had a family history of CAD. At last follow-up, only 27 patients of the initial 81 smokers still smoked, only 2.1% of the patients had uncontrolled hypertension, 10.6%of the patientshad uncontrolled dyslipidemia, and 2.1%of the patientshad uncontrolled diabetes. Coronary artery disease progression was found in up to 81 (77.9%) patients. Baseline diabetes and younger age were associatedwith increased odds of CAD progression.The time intervalbetween baseline and follow-up angiography was also associatedwith CAD progression. Conclusion: Coronary artery disease progressionwas highly prevalent in these patients despite comprehensive risk factor intervention. Further research is needed to optimize treatment of known risk factors and to identify other unknown and potentiallymodifiable risk factors.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cardiogoniometry (CGM), a spatiotemporal electrocardiologic 5-lead method with automated analysis, may be useful in primary healthcare for detecting coronary artery disease (CAD) at rest. Our aim was to systematically develop a stenosis-specific parameter set for global CAD detection. In 793 consecutively admitted patients with presumed non-acute CAD, CGM data were collected prior to elective coronary angiography and analyzed retrospectively. 658 patients fulfilled the inclusion criteria, 405 had CAD verified by coronary angiography; the 253 patients with normal coronary angiograms served as the non-CAD controls. Study patients--matched for age, BMI, and gender--were angiographically assigned to 8 stenosis-specific CAD categories or to the controls. One CGM parameter possessing significance (P < .05) and the best diagnostic accuracy was matched to one CAD category. The area under the ROC curve was .80 (global CAD versus controls). A set containing 8 stenosis-specific CGM parameters described variability of R vectors and R-T angles, spatial position and potential distribution of R/T vectors, and ST/T segment alterations. Our parameter set systematically combines CAD categories into an algorithm that detects CAD globally. Prospective validation in clinical studies is ongoing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The cause of angina in patients presenting at coronary angiography without significant coronary artery disease (CAD) has not been systematically assessed in a large prospective cohort. This study is aimed to identify the cause of angina in these patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Two young women with angiographically normal coronary arteries suffered an acute myocardial infarction. Both were found to have a patent foramen ovale (PFO), the likely pathway of a paradoxical embolus causing the infarction. The PFOs were diagnosed and closed percutaneously with an Amplatzer PFO Occluder during the emergency coronary angiography.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Paclitaxel-eluting stents (PES) have been shown to reduce the rate of restenosis and the need for repeated revascularization procedures compared with bare metal stents. However, long-term effects of paclitaxel on vascular function are unknown. The purpose of the present study was to assess coronary vasomotor response to exercise after paclitaxel-eluting stent implantation. METHODS: Coronary vasomotion was evaluated by biplane quantitative coronary angiography at rest and during supine bicycle exercise in 27 patients with coronary artery disease. Twelve patients were treated with a bare metal stent (controls), and fifteen patients with a paclitaxel-eluting stent. All patients were restudied 6+/-2 (range 2-12) months after stent implantation. Minimal luminal diameter, stent diameter, proximal, distal and a reference vessel diameter were determined. RESULTS: Reference vessels showed exercise-induced vasodilation in both groups (+20+/-5% controls; +26+/-3% PES group). Vasomotion within the stented vessel segments was abolished. In the controls, the adjacent segments proximal and distal to the stent showed exercise-induced vasodilation (+17+/-3% and +24+/-4%). In contrast, there was exercise-induced vasoconstriction of the proximal and distal vessel segments adjacent to the paclitaxel-eluting stent (-13+/-6% and -18+/-4%; p<0.005). After sublingual nitroglycerin, the proximal and distal vessel segments dilated in both groups. Exercise-induced vasoconstriction adjacent to paclitaxel-eluting stent correlated inversely with the time interval after stent implantation. CONCLUSIONS: Paclitaxel-eluting stent implantation is associated with exercise-induced vasoconstriction in the persistent region suggesting endothelial dysfunction as the underlying mechanism. Improvement of vascular function occurs over time, indicating delayed vascular healing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The coronary artery calcium (CAC) score is a readily and widely available tool for the noninvasive diagnosis of atherosclerotic coronary artery disease (CAD). The aim of this study was to investigate the added value of the CAC score as an adjunct to gated SPECT for the assessment of CAD in an intermediate-risk population. METHODS: Seventy-seven prospectively recruited patients with intermediate risk (as determined by the Framingham Heart Study 10-y CAD risk score) and referred for coronary angiography because of suspected CAD underwent stress (99m)Tc-tetrofosmin SPECT myocardial perfusion imaging (MPI) and CT CAC scoring within 2 wk before coronary angiography. The sensitivity and specificity of SPECT alone and of the combination of the 2 methods (SPECT plus CAC score) in demonstrating significant CAD (>/=50% stenosis on coronary angiography) were compared. RESULTS: Forty-two (55%) of the 77 patients had CAD on coronary angiography, and 35 (45%) had abnormal SPECT results. The CAC score was significantly higher in subjects with perfusion abnormalities than in those who had normal SPECT results (889 +/- 836 [mean +/- SD] vs. 286 +/- 335; P < 0.0001). Similarly, with rising CAC scores, a larger percentage of patients had CAD. Receiver-operating-characteristic analysis showed that a CAC score of greater than or equal to 709 was the optimal cutoff for detecting CAD missed by SPECT. SPECT alone had a sensitivity and a specificity for the detection of significant CAD of 76% and 91%, respectively. Combining SPECT with the CAC score (at a cutoff of 709) improved the sensitivity of SPECT (from 76% to 86%) for the detection of CAD, in association with a nonsignificant decrease in specificity (from 91% to 86%). CONCLUSION: The CAC score may offer incremental diagnostic information over SPECT data for identifying patients with significant CAD and negative MPI results.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.