988 resultados para Coronary Flow Reserve
Resumo:
BACKGROUND The use of ultrathin Doppler angioplasty guidewires has made it possible to measure collateral flow quantitatively. Pharmacologic interventions have been shown to influence collateral flow and, thus, to affect myocardial ischaemia. METHODS Twenty-five patients with coronary artery disease undergoing PTCA were included in the present analysis. Coronary flow velocities were measured in the ipsilateral (n = 25) and contralateral (n = 6; two Doppler wires) vessels during PTCA with and without i.v. adenosine (140 microg/kg.min) before and 3 min after 5 mg metoprolol i.v., respectively. The ipsilateral Doppler wire was positioned distal to the stenosis, whereas the distal end of the contralateral wire was in an angiographically normal vessel. The flow signals of the ipsilateral wire were used to calculate the collateral flow index (CFI). CFI was defined as the ratio of flow velocity during balloon inflation divided by resting flow. RESULTS Heart rate and mean aortic pressure decreased slightly (ns) after i.v. metoprolol. The collateral flow index was 0.25+/-0.12 (one fourth of the resting coronary flow) during the first PTCA and 0.27+/-0.14 (ns versus first PTCA) during the second PTCA, but decreased with metoprolol to 0.16+/-0.08 (p<0.0001 vs. baseline) during the third PTCA. CONCLUSIONS Coronary collateral flow increased slightly but not significantly during maximal vasodilatation with adenosine but decreased in 23 of 25 patients after i.v. metoprolol. Thus, there is a reduction in coronary collateral flow with metoprolol, probably due to an increase in coronary collateral resistance or a reduction in oxygen demand.
Resumo:
The coronary collateral circulation is an alternative source of blood supply to a myocardial area jeopardized by the failure of the stenotic or occluded vessel to provide enough blood flow to this region. Until recently, only qualitative or semiqualitative methods have been available for the assessment of the coronary collateral circulation in humans, such as the patient's history of walk-through angina pectoris, the registration of intracoronary ECG signs for myocardial ischaemia or angina pectoris during coronary occlusion, or coronary angiographic classification (score 0-3) of collaterals. Studies of coronary wedge pressure measurements distal of a balloon-occluded coronary artery and the recent advent of ultrathin pressure and Doppler angioplasty guidewires have made it possible to obtain pressure or flow velocity data in remote vascular areas and, thus, to calculate functional variables for coronary collateral flow. Those coronary occlusive pressure- and flow velocity-derived parameters express collateral flow as a fraction of antegrade coronary flow during vessel patency of the collateral-receiving vessel. They are both interchangeable, and they have been validated in comparison to 'traditional' methods and against each other. The possibility of accurately measuring coronary collateral flow indices in humans undergoing coronary balloon angioplasty opens areas of investigation of the pathogenesis, pathophysiology and therapeutic promotion of the collateral circulation previously reserved for exclusively experimental studies. The purpose of this article is to review several clinically available methods for the functional characterization of the coronary collateral circulation.
Resumo:
Purpose: Best percutaneous treatment strategy for lesions in coronary bifurcations is an ongoing subject of debate. There is limited data that analyses the effect of the different bifurcation strategies on coronary flow. Our aim is to evaluate the influence of different bifurcation stenting strategies on hemodynamic parameters, both in the main vessel (MV) and side branch (SB).
Resumo:
Background. Stress myocardial contrast echo (MCE) is technically challenging with exercise (Ex) because of cardiacmovementandshort duration ofhyperemia.Vasodilators solve these limitations, but are less potent for inducing abnormal wall motion (WM). We sought whether a combined dipyridamole (DI; 0.56 mg/kg i.v. 4 min) and Ex stress protocol would enable MCE to provide incremental benefit toWManalysis for detection of CAD. Methods. Standard echo images were followed by real time MCE at rest and following stress in 85 pts, 70 undergoing quantitative coronary angiography and 15 low risk pts.WMAfrom standard and LVopacification images, and then myocardial perfusion were assessed sequentially in a blinded fashion. A subgroup of 13 pts also underwent Ex alone, to assess the contribution of DI to quantitative myocardial flow reserve (MFR). Results. Significant (>50%) stenoses were present in 43 pts, involving 69 territories. Addition of MCE improved SE sensitivity for detection of CAD (91% versus 74%, P = 0.02) and better appreciation of disease extent (87% versus 65%territories, P=0.003), with a non-significant reduction in specificity. In 55 territories subtended by a significant stenosis, but with no resting WM abnormality, ability to identify ischemia was also significantly increased by MCE (82% versus 60%, P = 0.002). MFR was less with Ex alone than with DIEx stress (2.4 ± 1.6 versus 4.0 ± 1.9, P = 0.05), suggesting prolongation of hyperaemia with DI may be essential to the results. Conclusions. Dipyridamole-exercise MCE adds significant incremental benefit to standard SE, with improved diagnostic sensitivity and more accurate estimation of extent of CAD.
Resumo:
BACKGROUND: Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. METHODS: Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and myocardial flow reserve (MFR) polar maps were quantified and analyzed using a 17-segment model. Comparisons used Pearson's correlation ρ (measuring precision), Bland and Altman limit-of-agreement and Lin's concordance correlation ρc = ρ·C b (C b measuring systematic bias). RESULTS: Lin's concordance and Pearson's correlation values were very similar, suggesting no systematic bias between software packages with an excellent precision ρ for MBF (ρ = 0.97, ρc = 0.96, C b = 0.99) and good precision for MFR (ρ = 0.83, ρc = 0.76, C b = 0.92). On a per-segment basis, no mean bias was observed on Bland-Altman plots, although PMOD provided slightly higher values than FlowQuant at higher MBF and MFR values (P < .0001). CONCLUSIONS: Concordance between software packages was excellent for MBF and MFR, despite higher values by PMOD at higher MBF values. Both software packages can be used interchangeably for quantification in daily practice of Rb-82 cardiac PET.
Resumo:
Objectives This prospective study investigated the effects of caffeine ingestion on the extent of adenosine-induced perfusion abnormalities during myocardial perfusion imaging (MPI). Methods Thirty patients with inducible perfusion abnormalities on standard (caffeine-abstinent) adenosine MPI underwent repeat testing with supplementary coffee intake. Baseline and test MPIs were assessed for stress percent defect, rest percent defect, and percent defect reversibility. Plasma levels of caffeine and metabolites were assessed on both occasions and correlated with MPI findings. Results Despite significant increases in caffeine [mean difference 3,106 μg/L (95% CI 2,460 to 3,752 μg/L; P < .001)] and metabolite concentrations over a wide range, there was no statistically significant change in stress percent defect and percent defect reversibility between the baseline and test scans. The increase in caffeine concentration between the baseline and the test phases did not affect percent defect reversibility (average change −0.003 for every 100 μg/L increase; 95% CI −0.17 to 0.16; P = .97). Conclusion There was no significant relationship between the extent of adenosine-induced coronary flow heterogeneity and the serum concentration of caffeine or its principal metabolites. Hence, the stringent requirements for prolonged abstinence from caffeine before adenosine MPI—based on limited studies—appear ill-founded.
Resumo:
Acute heart failure syndrome represents a prominent and growing health problem all around the world. Ideally, medical treatment for patients admitted to hospital because of this syndrome, in addition to alleviating the acute symptoms, should also prevent myocardial damage, modulate neurohumoral and inflammatory activation, and preserve or even improve renal function. Levosimendan is a cardiac enhancer having both inotropic and vasodilatory effects. It is approved for the short-term treatment of acutely decompensated chronic heart failure, but it has been shown to have beneficial clinical effects also in ischemic heart disease and septic shock as well as in perioperative cardiac support. In the present study, the mechanisms of action of levosimendan were studied in isolated guinea-pig heart preparations: Langendorff-perfused heart, papillary muscle and permeabilized cardiomyocytes as well as in purified phosphodiesterase isoenzyme preparations. Levosimendan was shown to be a potent inotropic agent in isolated Langendorff-perfused heart and right ventricle papillary muscle. In permeabilized cardiomyocytes, it was demonstrated to be a potent calcium sensitizer in contrast to its enantiomer, dextrosimendan. It was additionally shown to be a very selective phosphodiesterase (PDE) type-3 inhibitor, the selectivity factor for PDE3 over PDE4 being 10000 for levosimendan. Irrespective of this very selective PDE3 inhibitory property in purified enzyme preparations, the inotropic effect of levosimendan was demonstrated to be mediated mainly through calcium sensitization in the isolated heart as well as the papillary muscle preparations at clinically relevant concentrations. In the isolated Lagendorff-perfused heart, glibenclamide antagonized the levosimendan-induced increase in coronary flow (CF). Therefore, the main vasodilatory mechanism in coronary veins is believed to be the opening of the ATP-sensitive potassium (KATP) channels. In the paced hearts, CF did not increase in parallel with oxygen consumption (MVO2), thus indicating that levosimendan had a direct vasodilatory effect on coronary veins. The pharmacology of levosimendan was clearly different from that of milrinone, which induced an increase in CF in parallel with MVO2. In conclusion, levosimendan was demonstrated to increase cardiac contractility by binding to cardiac troponin C and sensitizing the myofilament contractile proteins to calcium, and further to induce coronary vasodilatation by opening KATP channels in vascular smooth muscle. In addition, the efficiency of the cardiac contraction was shown to be more advantageous when the heart was perfused with levosimendan in comparison to milrinone perfusion.
Resumo:
RESUMO: Introdução - A utilização de células e das suas propriedades para o tratamento das doenças cardiovasculares, é uma promessa para o futuro e talvez a única forma de ultrapassar algumas das insuficiências das terapêuticas atuais. A via de entrega das células mais utilizada na investigação tem sido a intracoronária, ganhando a microcirculação especial relevância, por ser onde ocorre a primeira interação com o tecido nativo. As células estaminais mesenquimais (CEM) têm propriedades que as tornam particularmente aptas para a Terapia Celular, mas as suas dimensões, superiores ao diâmetro dos capilares, tem motivado controvérsia quanto à sua entrega intracoronária. A cardiologia de intervenção tem atualmente técnicas que permitem a avaliação em tempo real e in vivo do estado da microcirculação coronária. A determinação do índice da resistência da microcirculação (IRM) fornece informação sobre a circulação dos pequenos vasos, de forma independente da circulação coronária e do estado hemodinâmico, mas a aplicabilidade clínica deste conhecimento encontra-se ainda por definir. Objectivos Esclarecer o potencial do IRM no estudo dos efeitos do transplante de CEM por via intracoronária. População e Métodos . Estudo pré-clínico com modelo animal (suíno) desenvolvido em 3 fases. Na Primeira Fase foram utilizados 8 animais saudáveis para estudar e validar a técnica de determinação de estudo da microcirculação. Efetuou-se a determinação do IRM com duas doses diferentes de papaverina para a indução da resposta hiperémica máxima (5 e 10 mg) e após a disfunção da microcirculação com injeção intracoronária de microesferas de embozene com 40 μm de diâmetro. Na Segunda Fase foram utilizados 18 animais saudáveis, randomizados em grupo controlo e grupo recetor de 30 x 106 CEM por via intracoronária. Foram avaliados de forma cega o IRM, a pressão aórtica, o fluxo coronário epicárdico e a ocorrência de alterações electrocardiográficas. Na Terceira Fase foram utilizados 18 animais, com enfarte agudo do miocárdio provocado (EAM), randomizados em grupo controlo, grupo recetor de CEM expandidas de forma convencional e grupo recetor de CEM expandidas com metodologia inovadora e de menores dimensões. Foi realizada uma exploração da dose/efeito com infusão faseada de 10 x 106, 15 x 106 e 20 x 106 CEM, com determinação do IRM, da pressão aórtica, do fluxo coronário epicárdico e da ocorrência de alterações eletrocardiográficas. Quatro semanas após a entrega das células foi novamente avaliado o IRM e foi efetuado o estudo anatomopatológico dos animais na procura de evidência de neoangiogénese e de regeneração miocárdica, ou de um efeito positivo da resposta reparadora após o enfarte. Resultados Nas 3 fases todos os animais mantiveram estabilidade hemodinâmica e eletrocardiográfica, com exceção da elevação de ST de V1-V3 verificada após a injeção das microesferas. Na Primeira Fase as duas doses de papaverina induziram uma resposta hiperémica eficaz, sem tradução com significado na determinação do IRM (variação da pressão distal de - 11,4 ± 5 e de - 10,6± 5 mmHg com as doses de 5 e 10 mg respetivamente (p=0,5). Com a injeção das microesferas o IRM teve uma elevação média de 310 ± 190 %, para um valor médio de 41,3 ± 16 U (p = 0,001). Na Segunda Fase não houve diferenças significativas dos parâmetros hemodinâmicos, do fluxo epicárdico e da avaliação eletrocardiográfica entre os dois grupos. O IRM de base foi semelhante e após a infusão intracoronária observou-se uma elevação expressiva do IRM nos animais que receberam células em comparação com o grupo controlo (8,8 U ± 1 vs. 14,2 U ± 1,8, P=0,02) e quanto ao seu valor de base (aumento de 112%, p=0,008). Na terceira Fase não houve novamente diferenças significativas dos parâmetros hemodinâmicos, do fluxo epicárdico e da avaliação eletrocardiográfica entre os três grupos. Houve uma elevação do IRM nos animais que receberam células a partir da 2ª dose (72% nas células convencionai e 108% nas células inovadoras) e que se manteve com a 3ª dose (100% nas células convencionais e 88% nas inovadoras) com significado estatístico em comparação com o grupo controlo (p=0,034 com a 2ªdose e p=0,024 com a 3ª dose). Quatro semanas após a entrega das CEM observou-se a descida do IRM nos dois grupos que receberam células, para valores sobreponíveis aos do grupo controlo e aos valores pós-EAM. Na avaliação anatomopatológica e histológica dos corações explantados não houve diferenças entre os três grupos. Conclusões O IRM permite distinguir alterações da microcirculação coronária motivadas pela entrega intracoronária de CEM, na ausência de alterações de outros parâmetros clínicos da circulação coronária utilizados em tempo real. As alterações do IRM são progressivas e passíveis de avaliar o efeito/dose, embora não tenha sido possível determinar diferenças com os dois tipos de CEM. No nosso modelo a injeção intracoronária não se associou a evidência de efeito benéfico na reparação ou regeneração miocárdica após o EAM.---------------------------- ABSTRACT: ABSTRACT Introduction The use of cells for the treatment of cardiovascular disease is a promise for the future and perhaps the only option to overcome some of the shortcomings of current therapies. The strategy for the delivery of cells most often used in current research has been the intracoronary route and due to this microcirculation gains special relevance, mainly because it is the first interaction site of transplanted cells with the native tissue. Mesenchymal stem cells (MSC) have properties that make them suitable for Cell Therapy, but its dimensions, larger than the diameter of capillaries, have prompted controversy about the safety of intracoronary delivery. The interventional cardiology currently has techniques that allow for real-time and in vivo assessment of coronary microcirculation state. The determination of the index of microcirculatory resistance index (IMR) provides information about small vessels, independently of the coronary circulation and hemodynamic status, but the clinical applicability of this knowledge is yet to be defined. Objectives To clarify the potential use of IMR in the study of the effects of MSC through intracoronary transplantation. Population and Methods Preclinical study with swine model developed in three phases. In Phase One 8 healthy animals were used to study and validate the IMR assessment in our animal model. IMR was assessed with two different doses of papaverine for inducing the maximal hyperaemic response (5 and 10 mg) and microcirculation dysfunction was achieved after intracoronary injection with embozene microspheres with 40 μm in diameter. In Phase Two we randomized 18 healthy animals divided between the control group and the one receiving 30 x 106 MSC through an intracoronary infusion. There we blindly evaluated IMR, the aortic pressure, the epicardial coronary flow and the occurrence of ECG changes. In Phase Three we used 18 animals with a provoked acute myocardial infarction (AMI), randomized into a control group, a MSC expanded conventionally receiver group and a MSC expanded with an innovative methodology receiver group. There was a stepwise infusion with doses of 10 x 106, 15 x 106 and 20 x 106 MSC with determination of IMR, the aortic pressure, the epicardial coronary flow and occurrence of electrocardiographic abnormalities. Four weeks after cell delivery we again measured the IMR and proceeded with the pathological study of animals in the search for evidence of neoangiogenesis and myocardial regeneration, or a positive effect in the reparative response following the infarction. Results All animals remained hemodynamically stable and with no electrocardiographic abnormalities, except for the ST elevation in V1-V3 observed after injection of the microspheres. In Phase One the two doses of papaverine achieved an hyperemic and effective response without significant differences in IMR (variation of the distal pressure -11.4 ± 5 and -10.6 ± 5 mmHg with the doses of 5 and 10 mg respectively (p = 0.5). With the injection of the microspheres the IMR had an average increase of 310 ± 190% for an average value of 41.3 ± 16 U (p = 0.001). In the second phase there were no significant differences in hemodynamic parameters, epicardial flow and electrocardiographic assessment between the two groups. The baseline IMR was similar and after intracoronary infusion there was a significant increase in animals receiving cells compared with the control group (8.8 ± U 1 vs. 14.2 ± 1.8, p = 0.02) and with their baseline (112% increase, p = 0.008). In the third phase again there were no significant differences in hemodynamic parameters, the epicardial flow and electrocardiographic evaluation between the three groups. There was a significant increase in IMR in animals that received cells from the 2nd dose (72% in conventional cells and 108% in the innovative cells) that remained with the 3rd dose (100% in conventional cells and 88% in the innovative) with statistical significance compared with the control group (p = 0.034 with 2nd dose, p = 0.024 with 3rd dose). Four weeks after delivery of the MSC we observed the fall of the IMR in the two groups that received cells with values overlapping those of the control group. In pathological and histological evaluation of removed hearts there were no differences among the three groups. Conclusions The IMR allows for the differentiation of changes in coronary microcirculation motivated by intracoronary delivery of MSC in the absence of modification in other clinical parameters. IMR changes are progressive and enable the evaluation of the effect / dose, though it has not been possible to determine differences in the two types of MSC. In our model, intracoronary injection of MSC was not associated with evidence of repair or myocardial regeneration after AMI.
Resumo:
Introducción: Las enfermedades cardiovasculares son la causa de muerte más frecuente en el mundo desarrollado, la mayoría de éstas se relacionan con alteraciones de las arterias coronarias, sin embargo un subgrupo de pacientes presentan como causa de isquemia cardiaca alteraciones estructurales. Material y métodos: Estudio Descriptivo. Se utilizó la base de datos recolectada en un servicio de hemodinamia de Bogotá durante dos años. Se aplicaron criterios de inclusión y exclusión y se determinaron cuatro grupos etáreos, a todos los pacientes se les practicó cateterismo cardiaco diagnóstico. Las variables analizadas fueron: diagnóstico de referencia, antecedentes y resultados del cateterismo incluyendo presencia de anomalías estructurales como las valvulopatias, el origen anómalo de las coronarias y los puentes miocárdicos. Para el análisis descriptivo se utilizó reporte de prevalencias y para el análisis de asociaciones se utilizaron tablas de contingencia y el estadístico de prueba Chi cuadrado, no se realizó análisis multivariado debido a que no se encontraron asociaciones estadísticamente significativas. Resultados: La edad promedio de los pacientes fue de 62 años (DS= 10,5), la representación del género masculino fue del 61,7%, la prevalencia de angina estable fue del 61,6%, los 3 antecedentes más prevalentes fueron: hipertensión arterial (41,4%), la hiperlipidemia (19,1%) y la Diabetes Mellitus (17,7%). La prevalencia de las alteraciones estructurales en la población de estudio de manera general fue del 12,9%, y su distribución por tipo fue: 1,4% para puentes miocárdicos, 0,7% para origen anómalo de las arterias coronarias y 10,8% de enfermedad valvular. Conclusiones: Se encontró una asociación entre los antecedentes médicos y la presencia de valvulopatias cardiacas. Se evidenció que el género no tiene relación con la presencia de alteraciones cardíacas a pesar de la mayor participación de hombres en la población de estudio. Las limitantes de este estudio se relacionaron con el tamaño de muestra, debido a la baja prevalencia de las anomalías estructurales medidas.
Resumo:
The effects of ATP, ADP, and adenosine in the processes of platelet aggregation, vasodilatation, and coronary flow have been known for many years. The sequential hydrolysis of ATP to adenosine by soluble nucleotidases constitutes the main system for rapid inactivation of circulating adenine nucleotides. Thyroid disorders affect a number of biological factors including adenosine levels in different fractions. Then, we intend to investigate if the soluble nucleotidases responsible for the ATP, ADP, and AMP hydrolysis are affected by variations in the thyroid hormone levels in blood serum from adult rats. Hyperthyroidism was induced by daily intraperitoneal injections of L-thyroxine (T4) (2.5 and 10.0 mu g/100 g body weight, respectively) for 7 or 14 days. Hypothyroidism was induced by thyroidectomy and methimazole (0.05%) added to their drinking water during 7 or 14 days. The treatments efficacy was confirmed by determination of hemodynamic parameters and cardiac hypertrophy evaluation. T4 treatment predominantly inhibited, and hypothyroidism (14 days after thyroidectomy) predominantly increased the ATP, ADP, and AMP hydrolysis in rat blood serum. These results suggest that both excess and deficiency of thyroid hormones can modulate the ATP diphosphohydrolase and 5`-nucleotidase activities in rat blood serum and consequently modulate the effects mediated by these enzymes and their products in vascular system. (C) 2010 International Union of Biochemistry and Molecular Biology, Inc.
Resumo:
Bothrops marajoensis is found in the savannah of Marajo Island in the State of Par S and regions of Amapa State, Brazil. The aim of the work was to study the renal and cardiovascular effects of the B. marajoensis venom and phospholipase A(2) (PLA(2)). The venom was fractionated by Protein Pack 5PW. N-terminal amino acid sequencing of sPLA(2) showed amino acid identity with other lysine K49sPLA(2)s of snake venom. B. marajoensis venom (30 mu g/mL) decreased the perfusion pressure, renal vascular resistance, urinary flow, glomerular filtration rate and sodium tubular transport. PLA(2) did not change the renal parameters. The perfusion pressure of the mesenteric bed did not change after infusion of venom. In isolated heart, the venom decreased the force of contraction and increased PP but did not change coronary flow. In the arterial pressure, the venom and PLA(2) decreased mean arterial pressure and cardiac frequency. The presence of atrial flutter and late hyperpolarisation reversed, indicating QRS complex arrhythmia and dysfunction in atrial conduction. In conclusion, B. marajoensis venom and PLA(2) induce hypotension and bradycardia while simultaneously blocking electrical conduction in the heart. Moreover, the decrease in glomerular filtration rate, urinary flow and electrolyte transport demonstrates physiological changes to the renal system. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Background: There is a growing need to improve myocardial protection, which will lead to better performance of cardiac operations and reduce morbidity and mortality. Therefore, the objective of this study was to compare the efficacy of myocardial protection solution using both intracellular and extracellular crystalloid type regarding the performance of the electrical conduction system, left ventricular contractility and edema, after being subjected to ischemic arrest and reperfusion. Methods: Hearts isolated from male Wistar (n=32) rats were prepared using Langendorff method and randomly divided equally into four groups according the cardioprotective solutions used Krebs-Henseleit-Buffer (KHB), Bretschneider-HTK (HTK), St. Thomas-1 (STH-1) and Celsior (CEL). After stabilization with KHB at 37 degrees C, baseline values (control) were collected for heart rate (HR), left ventricle systolic pressure (LVSP), maximum first derivate of rise left ventricular pressure (+dP/dt), maximum first derivate of fall left ventricular pressure (-dP/dt) and coronary flow (CF). The hearts were then perfused at 10 degrees C for 5 min and kept for 2 h in static ischemia at 20 degrees C in each cardioprotective solution. Data evaluation was done using analysis of variance in completely randomized One-Way ANOVA and Tukey's test for multiple comparisons. The level of statistical significance chosen was P<0.05. Results: HR was restored with all the solutions used. The evaluation of left ventricular contractility (LVSP, +dP/dt and -dP/dt) showed that treatment with CEL solution was better compared to other solutions. When analyzing the CF, the HTK solution showed better protection against edema. Conclusion: Despite the cardioprotective crystalloid solutions studied are not fully able to suppress the deleterious effects of ischemia and reperfusion in the rat heart, the CEL solution had significantly higher results followed by HTK>KHB>STH-1.
Resumo:
Background. There is a growing need to improve heart preservation benefit the performance of cardiac operations, decrease morbidity, and more important, increase the donor pool. Therefore, the objective of this study was to evaluate the cardioprotective effects of Krebs-Henseleit buffer (KHB), Bretschneider-HTK (HTK), St. Thomas No. 1 (STH-1), and Celsior (CEL) solutions infused at 10 degrees C and 20 degrees C. Methods. Hearts isolated from male albino Wistar rats and prepared according to Langendorff were randomly divided equally into 8 groups according to the temperature of infusion (10 degrees C or 20 degrees C) and cardioprotective solutions (KHB, HTK, STH-1, and CEL). After stabilization with KHB at 37 degrees C, baseline values were collected (control) for heart rate (HR), left ventricle systolic pressure (LVSP), coronary flow (CF), maximum rate of rise of left ventricular pressure during ventricular contraction (+dP/dt) and maximum rate of fall of left ventricular pressure during left ventricular relaxation (-dP/dt). The hearts were then perfused with cardioprotective solutions for 5 minutes and kept for 2 hours in static ischemia at 20 degrees C. Data evaluation used analysis of variance (ANOVA) in all together randomized 2-way ANOVA and Tukey's test for multiple comparisons. The level of significance chosen was P < .05. Results. We observed that all 4 solutions were able to recover HR, independent of temperature. Interestingly, STH-1 solution at 20 degrees C showed HR above baseline throughout the experiment. An evaluation of the corresponding hemodynamic values (LVSP, +dP/dt, and -dP/dt) indicated that treatment with CEL solution was superior at both temperatures compared with the other solutions, and had better performance at 20 degrees C. When analyzing performance on CF maintenance, we observed that it was temperature dependent. However, when applying both HTK and CEL, at 10 degrees C and 20 degrees C respectively, indicated better protection against development of tissue edema. Multiple comparisons between treatments and hemodynamic variable outcomes showed that using CEL solution resulted in significant improvement compared with the other solutions at both temperatures. Conclusion. The solutions investigated were not able to fully suppress the deleterious effects of ischemia and reperfusion of the heart. However, these results allow us to conclude that temperature and the cardioprotective solution are interdependent as far as myocardial protection. Although CEL solution is the best for in myocardial protection, more studies are needed to understand the interaction between temperature and perfusion solution used. This will lead to development of better and more efficient cardioprotective methods.
Resumo:
Aims Cardiac grafts from non-heartbeating donors (NHBDs) could significantly increase organ availability and reduce waiting-list mortality. Reluctance to exploit hearts from NHBDs arises from obligatory delays in procurement leading to periods of warm ischemia and possible subsequent contractile dysfunction. Means for early prediction of graft suitability prior to transplantation are thus required for development of heart transplantation programs with NHBDs. Methods and Results Hearts (n = 31) isolated from male Wistar rats were perfused with modified Krebs-Henseleit buffer aerobically for 20 min, followed by global, no-flow ischemia (32°C) for 30, 50, 55 or 60 min. Reperfusion was unloaded for 20 min, and then loaded, in working-mode, for 40 min. Left ventricular (LV) pressure was monitored using a micro-tip pressure catheter introduced via the mitral valve. Several hemodynamic parameters measured during early, unloaded reperfusion correlated significantly with LV work after 60 min reperfusion (p<0.001). Coronary flow and the production of lactate and lactate dehydrogenase (LDH) also correlated significantly with outcomes after 60 min reperfusion (p<0.05). Based on early reperfusion hemodynamic measures, a composite, weighted predictive parameter, incorporating heart rate (HR), developed pressure (DP) and end-diastolic pressure, was generated and evaluated against the HR-DP product after 60 min of reperfusion. Effective discriminating ability for this novel parameter was observed for four HR*DP cut-off values, particularly for ≥20 *103 mmHg*beats*min−1 (p<0.01). Conclusion Upon reperfusion of a NHBD heart, early evaluation, at the time of organ procurement, of cardiac hemodynamic parameters, as well as easily accessible markers of metabolism and necrosis seem to accurately predict subsequent contractile recovery and could thus potentially be of use in guiding the decision of accepting the ischemic heart for transplantation.
Resumo:
OBJECTIVES: Donation after circulatory declaration of death (DCDD) could significantly improve the number of cardiac grafts for transplantation. Graft evaluation is particularly important in the setting of DCDD given that conditions of cardio-circulatory arrest and warm ischaemia differ, leading to variable tissue injury. The aim of this study was to identify, at the time of heart procurement, means to predict contractile recovery following cardioplegic storage and reperfusion using an isolated rat heart model. Identification of reliable approaches to evaluate cardiac grafts is key in the development of protocols for heart transplantation with DCDD. METHODS: Hearts isolated from anaesthetized male Wistar rats (n = 34) were exposed to various perfusion protocols. To simulate DCDD conditions, rats were exsanguinated and maintained at 37°C for 15-25 min (warm ischaemia). Isolated hearts were perfused with modified Krebs-Henseleit buffer for 10 min (unloaded), arrested with cardioplegia, stored for 3 h at 4°C and then reperfused for 120 min (unloaded for 60 min, then loaded for 60 min). Left ventricular (LV) function was assessed using an intraventricular micro-tip pressure catheter. Statistical significance was determined using the non-parametric Spearman rho correlation analysis. RESULTS: After 120 min of reperfusion, recovery of LV work measured as developed pressure (DP)-heart rate (HR) product ranged from 0 to 15 ± 6.1 mmHg beats min(-1) 10(-3) following warm ischaemia of 15-25 min. Several haemodynamic parameters measured during early, unloaded perfusion at the time of heart procurement, including HR and the peak systolic pressure-HR product, correlated significantly with contractile recovery after cardioplegic storage and 120 min of reperfusion (P < 0.001). Coronary flow, oxygen consumption and lactate dehydrogenase release also correlated significantly with contractile recovery following cardioplegic storage and 120 min of reperfusion (P < 0.05). CONCLUSIONS: Haemodynamic and biochemical parameters measured at the time of organ procurement could serve as predictive indicators of contractile recovery. We believe that evaluation of graft suitability is feasible prior to transplantation with DCDD, and may, consequently, increase donor heart availability.