983 resultados para Cooking (Honey)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooking efficiency and related fuel economy issues have been studied in a particular rural area of India. Following a description of the cooking practices and conditions in this locale, cooking efficiency is examined. A cooking efficiency of only 6% was found. The use of aluminium rather than clay pots results in an increased efficiency. In addition, cooking efficiency correlates very well with specific fuel consumption. The latter parameter is much simpler to analyse than cooking efficiency. The energy losses during cooking are examined in the second part of this case study. The major energy losses are heating of excess air, heat carried away by the combustion products, heat transmitted to the stove body and floor, and the chemical energy in charcoal residue. The energy loss due to the evaporation of cooking water is also significant because it represents about one-third of the heat reaching the pots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Honey is valued for its medicinal properties. There interest from industry to develop a rapid method to detect the bioactivity of honey and also to develop value added products from high antibacterial honey.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To improve the yield of Honey Gold mango through nutrition, pruning and growth regulators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vapour heat treatment of honey gold mango for access to the Japanese market.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Honey Gold mango is a new Australian variety owned by a Queensland company, and in high demand because of very good flavour and appearance. It develops under skin browning (USB) when grown in hot areas. It appears after packing and the fruit need to be re-sorted at the markets to remove affected fruit. Production and postharvest treatments will be developed to reduce USB and increase profitability. Other production and harvest factors causing quality loss will be also be identified through a commercial downgrade analysis program in the packhouse. Grower training will reduce downgrades and improve the percentage of fruit in premium grade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

'Honey Gold' mango is a relatively new cultivar in Australia, with an appealing skin colour and a sweet fibre-free flesh. However, fruit can develop 'under-skin browning' (USB), which appears several days after packing as a distinct 'bruise'-like discolouration under the epidermis and can affect large areas of the fruit surface. We investigated the anatomy of USB and the impact of post-harvest fruit handling conditions on the disorder. Starch accumulated around the resin canals and discoloured cells in the affected area, with no visible change to the cuticle or epidermis. Delays of 1 d at ambient temperature (27 degrees - 35 degrees C) before packing, and 2 d at 18 degrees - 20 degrees C (after packing), before placing fruit at 12 degrees - 14 degrees C and road transportation, reduced the incidence of USB by 83% compared to placing fruit at 12 degrees - 14 degrees C within 13 h of picking. The incidence of USB was 88 100% higher in fruit that were cooled to 12 degrees - 14 degrees C within 13 h of picking, then commercially road-freighted for 4 d at 12 degrees - 14 degrees C, than in fruit held under similar temperature conditions, but not road-freighted. Wrapping each fruit in bubble-wrap to minimise direct contact with other fruit, with the plastic insert, or with the cardboard tray, reduced the incidence of USB by 84% after road-freight compared to not using bubble-wrap. These results suggest that USB is a unique disorder of mango skin associated with a rapid post-harvest reduction in temperature, from high ambient temperatures to 12 degrees - 14 degrees C, and with physical damage during road-freight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report of field observations April 2007 to September 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To measure the effect of maturity and cooking on phytochemical composition and antioxidant capacity of fruit and leaves of four commercially available Australian papaya cultivars (RB1, RB2, RB4 and YB1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reproductive isolation between closely related species is often incomplete. The Western honey bee, Apis mellifera, and the Eastern hive bee, A. cerana have been allopatric for millions of years, but are nonetheless similar in morphology and behaviour. During the last century the two species were brought into contact anthropogenically, providing potential opportunities for interspecific matings. Hybrids between A. mellifera and A. cerana are inviable, so natural interspecific matings are of concern because they may reduce the viability of A. cerana and A. mellifera populations – two of the world's most important pollinators. We examined the mating behaviour of A. mellifera and A. cerana queens and drones from Caoba Basin, China and Cairns, Australia. Drone mating flight times overlap in both areas. Analysis of the spermathecal contents of queens with species-specific genetic markers indicated that in Caoba Basin, 14% of A. mellifera queens mated with at least one A. cerana male, but we detected no A. cerana queens that had mated with A. mellifera males. Similarly, in Cairns, no A. cerana queens carried A. mellifera sperm, but one third of A. mellifera queens had mated with at least one A. cerana male. No hybrid embryos were detected in eggs laid by interspecifically-mated A. mellifera queens in either location. However A. mellifera queens artificially inseminated with A. cerana sperm produced inviable hybrid eggs, or unfertilised drones. This suggests that reproductive interference will impact the viability of honey bee populations wherever A. cerana and A. mellifera are in contact. This article is protected by copyright. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project has investigated the correlation between antimicrobial activity and the non-peroxide activity of particular Leptospermum-derived honeys. Initial investigations tested the efficacy of these honeys against one particular bacteria (Staphylococcus aureus), while later studies assessed the effect of this honey on a range of food pathogens, animal pathogens (e.g. in mastitis) and human pathogens (e.g. golden Staph). Using honeys sourced from around Australia and screened against several reference microorganisms, the anti-microbial potency of one particular Australian honey (from Leptospermum polygalifolium) was shown to be comparable to NZ Manuka honey (from L.scoparium). The results of this screening of active honeys against pathogenic bacteria has supported the registration of honey by Capilano Honey Limited as a “Drug” with the Therapeutic Goods Administration based on its antimicrobial activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a hybrid solar cooking system where the solar energy is transported to the kitchen. The thermal energy source is used to supplement the Liquefied Petroleum Gas (LPG) that is in common use in kitchens. Solar energy is transferred to the kitchen by means of a circulating fluid. Energy collected from sun is maximized by changing the flow rate dynamically. This paper proposes a concept of maximum power point tracking (MPPT) for the solar thermal collector. The diameter of the pipe is selected to optimize the overall energy transfer. Design and sizing of different components of the system are explained. Concept of MPPT is validated with simulation and experimental results. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the existing traditional solar cookers, the cooking is performed near the collector which may be at an inconvenient location for cooking purposes. This paper proposes a hybrid solar cooking system where the solar energy is brought to the kitchen. The energy source is a combination of the solar thermal energy and the Liquefied Petroleum Gas (LPG) that is very common in kitchens. The solar thermal energy is transferred to the kitchen by means of a circulating fluid like oil. The transfer of solar heat is a two fold process wherein the energy from the collector is transferred first to an intermediate energy storage tank and then the energy is subsequently transferred from the tank to the cooking load. There are three parameters that are controlled in order to maximize the energy transfer from the collector to the load viz. the fluid flow rate from collector to tank, fluid flow rate from tank to load and the diameter of the pipes. The entire system is modeled using the bond graph approach. This paper discusses the implementation of such a system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a hybrid solar cooking system where the solar energy is brought to the kitchen. The energy source is a combination of the solar thermal energy and the Liquefied Petroleum Gas (LPG) that is in common use in kitchens. The solar thermal energy is transferred to the kitchen by means of a circulating fluid. The transfer of solar heat is a twofold process wherein the energy from the collector is transferred first to an intermediate energy storage buffer and the energy is subsequently transferred from the buffer to the cooking load. There are three parameters that are controlled in order to maximize the energy transfer from the collector to the load viz, the fluid flow rate from collector to buffer, fluid flow rate from buffer to load and the diameter of the pipes. This is a complex multi energy domain system comprising energy flow across several domains such as thermal, electrical and hydraulic. The entire system is modeled using the bond graph approach with seamless integration of the power flow in these domains. A method to estimate different parameters of the practical cooking system is also explained. Design and life cycle costing of the system is also discussed. The modeled system is simulated and the results are validated experimentally. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A swarm is a temporary structure formed when several thousand honey bees leave their hive and settle on some object such as the branch of a tree. They remain in this position until a suitable site for a new home is located by the scout bees. A continuum model based on heat conduction and heat generation is used to predict temperature profiles in swarms. Since internal convection is neglected, the model is applicable only at low values of the ambient temperature T-a. Guided by the experimental observations of Heinrich (1981a-c, J. Exp. Biol. 91, 25-55; Science 212, 565-566; Sci. Am. 244, 147-160), the analysis is carried out mainly for non-spherical swarms. The effective thermal conductivity is estimated using the data of Heinrich (1981a, J. Exp. Biol. 91, 25-55) for dead bees. For T-a = 5 and 9 degrees C, results based on a modified version of the heat generation function due to Southwick (1991, The Behaviour and Physiology of Bees, PP 28-47. C.A.B. International, London) are in reasonable agreement with measurements. Results obtained with the heat generation function of Myerscough (1993, J. Theor. Biol. 162, 381-393) are qualitatively similar to those obtained with Southwick's function, but the error is more in the former case. The results suggest that the bees near the periphery generate more heat than those near the core, in accord with the conjecture of Heinrich (1981c, Sci. Am. 244, 147-160). On the other hand, for T-a = 5 degrees C, the heat generation function of Omholt and Lonvik (1986, J. Theor. Biol. 120, 447-456) leads to a trivial steady state where the entire swarm is at the ambient temperature. Therefore an acceptable heat generation function must result in a steady state which is both non-trivial and stable with respect to small perturbations. Omholt and Lonvik's function satisfies the first requirement, but not the second. For T-a = 15 degrees C, there is a considerable difference between predicted and measured values, probably due to the neglect of internal convection in the model.