964 resultados para Conventional


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study design: Single-blind randomized, controlled clinical study. Objectives: To evaluate, using kinematic gait analysis, the results obtained from gait training on a treadmill with body weight support versus those obtained with conventional gait training and physiotherapy. Setting: Thirty patients with sequelae from traumatic incomplete spinal cord injuries at least 12 months earlier; patients were able to walk and were classified according to motor function as ASIA (American Spinal Injury Association) impairment scale C or D. Methods: Patients were divided randomly into two groups of 15 patients by the drawing of opaque envelopes: group A (weight support) and group B (conventional). After an initial assessment, both groups underwent 30 sessions of gait training. Sessions occurred twice a week, lasted for 30min each and continued for four months. All of the patients were evaluated by a single blinded examiner using movement analysis to measure angular and linear kinematic gait parameters. Six patients (three from group A and three from group B) were excluded because they attended fewer than 85% of the training sessions. Results: There were no statistically significant differences in intra-group comparisons among the spatial-temporal variables in group B. In group A, the following significant differences in the studied spatial-temporal variables were observed: increases in velocity, distance, cadence, step length, swing phase and gait cycle duration, in addition to a reduction in stance phase. There were also no significant differences in intra-group comparisons among the angular variables in group B. However, group A achieved significant improvements in maximum hip extension and plantar flexion during stance. Conclusion: Gait training with body weight support was more effective than conventional physiotherapy for improving the spatial-temporal and kinematic gait parameters among patients with incomplete spinal cord injuries. Spinal Cord (2011) 49, 1001-1007; doi:10.1038/sc.2011.37; published online 3 May 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obstructive sleep apnea (OSA) is common among patients on maintenance hemodialysis. However, the factors associated with the origin of OSA as well as the cardiovascular consequences in this population are not completely understood. We evaluated, by standard overnight polysomnography, 24-hour ambulatory blood pressure (BP) monitoring and echocardiography in 30 patients (14 males, age 34 +/- 11 years, BMI 23.2 +/- 5.2) - 15 on short daily hemodialysis (SDH) and 15 matched patients on conventional hemodialysis (CHD). The hemodialysis dose (standard Kt/V) was higher in patients on SDH than on CHD (p = 0.001). OSA (apnea-hypopnea index 1 5 events/h) was present in 13 patients (43%). Patients with OSA were predominantly males (77 vs. 44%), presented a higher BMI (25.5 +/- 6.2 vs. 21.5 +/- 3.6), a larger neck circumference (38 +/- 1 vs. 34 +/- 1 cm) and a lower Kt/V (2.6 +/- 0.3 vs. 2.2 +/- 0.1) than patients with no OSA (p < 0.05). Neck circumference and lower Kt/V were independently associated with OSA on multivariate analysis. No patient with Kt/V > 2.5 (n = 10) presented OSA. On the other hand, hypertensive patients with OSA needed more BP control pills (p = 0.03). Despite similar BP control, patients with OSA presented a higher interventricular septum thickness (11.5 +/- 0.5 vs. 9.9 +/- 0.3 mm; p = 0.011). In conclusion, among patients on maintenance hemodialysis, the traditional risk factors for OSA are present and interact with hemodialysis efficiency. Among these patients, OSA is associated with difficult BP control and heart remodeling suggesting that OSA may contribute to poor cardiovascular outcome. Copyright (c) 2008 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The early identification of hearing impairment allows for an intervention still in the ""critical"" and ideal period of hearing and language stimulation. Pediatric ototoxicity is a very controversial topic. There have been variable percentages of ototoxicity cases in children with different aminoglycosides antibiotics. The main pediatric groups whom receive aminoglycosides are newborns with severe infections on the neonatal ICU. Aim: to check the functional aspect of the cochlear external hair cells and treatment regimens used to treat infections during the neonatal period. Study design: Experimental. Materials and Methods: we studied 26 albino guinea pigs, through distortion product otoacoustic emissions, before and after the use of gentamicin. Results: in all the assessments, the external hair cells functional status, studied by means of the distortion product otoacoustic emissions, proved preserved. Conclusion: In the present study, we did not notice changes in outer hair cell function in the albino guinea pigs treated with gentamicin in the doses of 4 mg/Kg/ day and 2.5 mg/Kg/day every 12 hours for 10 and 14 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the effectiveness of different irrigant agitation techniques on smear layer removal in curved root canals. Methods: Mesiobuccal canals of 62 extracted lower molars with a curvature of 33 degrees were used and instrumented up to Pro Taper F2. The samples were divided into 3 experimental groups according to the final irrigation: conventional irrigation, ultrasonic irrigation, and sonic irrigation by using the Endo Activator system. The control group was composed of 2 specimens without any final irrigation. In all of the experimental groups, 5 mL of 17% ethylenediaminetetraacetic acid was used for 1 minute, and 5 mL of 2.5% NaOCl was used for 30 seconds. The analysis of the apical region was performed via scanning electron microscopy by 3 examiners. The data were submitted to the Kruskal-Wallis and Dunn tests (P<.05). Results: The activation systems removed significantly more smear layer than did conventional irrigation. Conclusions: Sonic and ultrasonic irrigation resulted in better removal of the smear layer in the apical third of curved root canals than did conventional irrigation. (J Endod 2011;37:1268-1271)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this in vitro study was to compare the degree of microleakage of composite restorations performed by lasers and conventional drills associated with two adhesive systems. Materials and Methods: Sixty bovine teeth were divided into 6 groups (n = 10). The preparations were performed in groups 1 and 2 with a high-speed drill (HID), in groups 3 and 5 with Er:YAG laser, and in groups 4 and 6 with Er,Cr:YSGG laser. The specimens were restored with resin composite associated with an etch-and-rinse two-step adhesive system (Single Bond 2 [SB]) (groups 1, 3, 4) and a self-etching adhesive (One-Up Bond F [OB]) (groups 2, 5, 6). After storage, the specimens were polished, thermocycled, immersed in 50% silver nitrate tracer solution, and then sectioned longitudinally. The specimens were placed under a stereomicroscope (25X) and digital images were obtained. These were evaluated by three blinded evaluators who assigned a microleakage score (0 to 3). The original data were submitted to Kruskal-Wallis and Mann-Whitney statistical tests. Results: The occlusal/enamel margins demonstrated no differences in microleakage for all treatments (p > 0.05). The gingival/dentin margins presented similar microleakage in cavities prepared with Er:YAG, Er,Cr:YSGG, and HD using the etch-and-rinse two-step adhesive system (SB) (p > 0.05); otherwise, both Er:YAG and Er,Cr:YSGG lasers demonstrated lower microleakage scores with OB than SB adhesive (p < 0.05). Conclusion: The microleakage score at gingival margins is dependent on the interaction of the hard tissue removal tool and the adhesive system used. The self-etching adhesive system had a lower microleakage score at dentin margins for cavities prepared with Er:YAG and Er,Cr:YSGG than the etch-and-rinse two-step adhesive system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling. Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05). Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps. Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simulation of competitively primed allele-specific DNA amplification has been constructed and its behavior examined, This has shown that when the ratio of the amount of homoduplex misprime product to the total amount of amplimer is low, it increases by approximately one-fourth of the mispriming frequency with each doubling of the total amount of amplimer, When the ratio is high acid reverse mispriming becomes significant, it asymptotes toward a value

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A randomized controlled trial was carried out to measure the societal costs of realtime teledermatology compared with those of conventional hospital care in New Zealand. Two rural health centres were linked to a specialist hospital via ISDN at 128 kbit/s. Over 10 months, 203 patients were referred for a specialist dermatological consultation and 26 were followed up, giving a total of 229 consultations. Fifty-four per cent were randomized to the teledermatology consultation and 46% to the conventional hospital consultation. A cost-minimization analysis was used to calculate the total costs of both types of dermatological consultation. The total cost of the 123 teledermatology consultations was NZ$34,346 and the total cost of the 106 conventional hospital consultations was NZ$30,081. The average societal cost of the teledermatology consultation was therefore NZ$279.23 compared with NZ$283.79 for the conventional hospital consultation. The marginal cost of seeing an additional patient was NZ$135 via teledermatology and NZ$284 via conventional hospital appointment. From a societal viewpoint, and assuming an equal outcome, teledermatology was a more cost-efficient use of resources than conventional hospital care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A randomized controlled trial was carried out to measure the cost-effectiveness of realtime teledermatology compared with conventional outpatient dermatology care for patients from urban and rural areas. One urban and one rural health centre were linked to a regional hospital in Northern Ireland by ISDN at 128 kbit/s. Over two years, 274 patients required a hospital outpatient dermatology referral -126 patients (46%) were randomized to a telemedicine consultation and 148 (54%) to a conventional hospital outpatient consultation. Of those seen by telemedicine, 61% were registered with an urban practice, compared with 71% of those seen conventionally. The clinical outcomes of the two types of consultation were similar - almost half the patients were managed after a single consultation with the dermatologist. The observed marginal cost per patient of the initial realtime teledermatology consultation was f52.85 for those in urban areas and f59.93 per patient for those from rural areas. The observed marginal cost of the initial conventional consultation was f47.13 for urban patients and f48.77 for rural patients. The total observed costs of teledermatology were higher than the costs of conventional care in both urban and rural areas, mainly because of the fixed equipment costs. Sensitivity analysis using a real-world scenario showed that in urban areas the average costs of the telemedicine and conventional consultations were about equal, while in rural areas the average cost of the telemedicine consultation was less than that of the conventional consultation.