932 resultados para Control Methods
Resumo:
Ticks are obligate haematophagous ectoparasites of wild and domestic animals as well as humans, considered to be second worldwide to mosquitoes as vectors of human diseases. Tick-borne diseases are responsible worldwide for great economic losses in terms of mortality and morbidity of livestock animals. This review concerns to the different tick and tick-parasites control methods having a major focus on vaccines. Control of tick infestations has been mainly based on the use of acaricides, a control measure with serious drawbacks, as responsible for the contamination of milk and meat products, as a selective factor for acaricide-resistant ticks and as an environmental contaminant. Research on alternatives to the use of acaricides is strongly represented by tick vaccines considered a more cost-effective and environmentally safe strategy. Vaccines based on the Bm86 tick antigen were used in the first commercially available cattle tick vaccines and showed good results in reducing tick numbers, affecting weight and reproductive performance of female ticks which resulted in reduction of cattle tick populations over time and consequently lower reduction of the pathogen agents they carry.
Resumo:
Introduction The use of entomopathogenic fungi to control disease vectors has become relevant because traditional chemical control methods have caused damage to the environment and led to the development of resistance among vectors. Thus, this study assessed the pathogenicity of entomopathogenic fungi in Triatoma dimidiata. Methods Preparations of 108 conidia/ml of Gliocladium virens, Talaromyces flavus, Beauveria bassiana and Metarhizium anisopliae were applied topically on T. dimidiata nymphs and adults. Controls were treated with the 0.0001% Tween-80 vehicle. Mortality was evaluated and recorded daily for 30 days. The concentration required to kill 50% of T. dimidiata (LC50) was then calculated for the most pathogenic isolate. Results Pathogenicity in adults was similar among B. bassiana, G. virens and T. flavus (p>0.05) and differed from that in triatomine nymphs (p=0.009). The most entomopathogenic strains in adult triatomines were B. bassiana and G. virens, which both caused 100% mortality. In nymphs, the most entomopathogenic strain was B. bassiana, followed by G. virens. The native strain with the highest pathogenicity was G. virens, for which the LC50 for T. dimidiata nymphs was 1.98 x108 conidia/ml at 13 days after inoculation. Conclusions Beauveria bassiana and G. virens showed entomopathogenic potential in T. dimidiata nymphs and adults. However, the native G. virens strain presents a higher probability of success in the field, and G. virens should thus be considered a potential candidate for the biological control of triatomine Chagas disease vectors.
Resumo:
The control methods used in Brazil for both cutaneous and visceral leishmaniasis by the Ministry of Health's National Health Foundation (Fundação Nacional de Saúde) are presented. Data referring to the programme between 1980 and 1991 is presented. There was an increase in the total number of notified cases of cutaneous leishmaniasis until 1987 and from this date onwards the number has remained between 23,000 and 26,000 per year. There were significantly fewer cases of visceral leishmaniasis during the same period and until 1991 the greatest number of cases reported in one year was 2,511 in 1985. The overall picture is that it is difficult to evaluate to what extent the control methods employed have reduced the number of cases of either form of the disease. It is suggested that there is an urgent need for a closer approximation of research and health workers to review the actual control strategies and to define procedures capable of assessing accurately their impact.
Resumo:
In Brazil, the use of biological vector-control methods has been largely confined to experimental research, with little or no application of such techniques by public institutions responsible for implementing control programs. The notable exceptions have been the black fly control program carried out by the Health Secretariat in the State of São Paulo. Since the 1980s, São Paulo's "Superintendência de Controle de Endemias" has been conducting studies on the viability of using Bacillus thuringiensis (H-14) for simuliid control, and the results have been so encouraging that the agency has now incorporated this method into its Simuliid Control Program.
Resumo:
PURPOSE: An optimal target for glucose control in ICU patients remains unclear. This prospective randomized controlled trial compared the effects on ICU mortality of intensive insulin therapy (IIT) with an intermediate glucose control. METHODS: Adult patients admitted to the 21 participating medico-surgical ICUs were randomized to group 1 (target BG 7.8-10.0 mmol/L) or to group 2 (target BG 4.4-6.1 mmol/L). RESULTS: While the required sample size was 1,750 per group, the trial was stopped early due to a high rate of unintended protocol violations. From 1,101 admissions, the outcomes of 542 patients assigned to group 1 and 536 of group 2 were analysed. The groups were well balanced. BG levels averaged in group 1 8.0 mmol/L (IQR 7.1-9.0) (median of all values) and 7.7 mmol/L (IQR 6.7-8.8) (median of morning BG) versus 6.5 mmol/L (IQR 6.0-7.2) and 6.1 mmol/L (IQR 5.5-6.8) for group 2 (p < 0.0001 for both comparisons). The percentage of patients treated with insulin averaged 66.2 and 96.3%, respectively. Proportion of time spent in target BG was similar, averaging 39.5% and 45.1% (median (IQR) 34.3 (18.5-50.0) and 39.3 (26.2-53.6)%) in the groups 1 and 2, respectively. The rate of hypoglycaemia was higher in the group 2 (8.7%) than in group 1 (2.7%, p < 0.0001). ICU mortality was similar in the two groups (15.3 vs. 17.2%). CONCLUSIONS: In this prematurely stopped and therefore underpowered study, there was a lack of clinical benefit of intensive insulin therapy (target 4.4-6.1 mmol/L), associated with an increased incidence of hypoglycaemia, as compared to a 7.8-10.0 mmol/L target. (ClinicalTrials.gov # NCT00107601, EUDRA-CT Number: 200400391440).
Resumo:
The Centre de Recherche sur les Méningites et les Schistosomes (CERMES) is a research institute depending on the Organisation de Coordination et de Coopération pour la lutte contre les Grandes Endémies - a West African Organization for Public Health - devoted to the studies on schistosomiasis and meningitis. The staff includes 32 persons with 11 scientists and one financial officer. The activities of the CERMES involving schistosomiasis concern three research units: (a) ecology of human and animal schistosomiasis transmission; the CERMES defined the different patterns of schistosomiasis transmission in Niger (involving African dry savana); in this field, we have shown, (i) the existence of important variability in conditions of transmission of S. haematobium and, (ii) natural hybridization between parasitic species of the ruminants (S. bovis and S. curassoni) and genetic interaction between human and animal parasites; (b) definition of morbidity indicators usable for rapid assessment methods, for appraisal of the severity of the disease and for the evaluation of the efficiency of control methods; we have established the correlation between ultrasonographic data and some cheap and simple field indicators; (c) immune response and protective immunity induced by recombinant glutathion S-transferase (Sm28, Sb28 and Sh28) in homologous and heterologous animal models including goats, sheep and non human primates (Erythrocebus patas). In Niger, we participate in all control programs against schistosomiasis to define control strategies, to supervise operations and to participate in their evaluation with external experts. International collaborations constitute a frame including four laboratories in Africa and six laboratories in developed countries (Europe and USA)
Resumo:
Malaria is a mosquito-borne infectious disease caused by Plasmodium parasites transmitted by the infectious bite of Anopheles mosquitoes. Vector control of malaria has predominantly focused on targeting the adult mosquito through insecticides and bed nets. However, current vector control methods are often not sustainable for long periods so alternative methods are needed. A novel biocontrol approach for mosquito-borne diseases has recently been proposed, it uses maternally inherited endosymbiotic Wolbachia bacteria transinfected into mosquitoes in order to interfere with pathogen transmission. Transinfected Wolbachia strains in Aedes aegypti mosquitoes, the primary vector of dengue fever, directly inhibit pathogen replication, including Plasmodium gallinaceum, and also affect mosquito reproduction to allow Wolbachia to spread through mosquito populations. In addition, transient Wolbachia infections in Anopheles gambiae significantly reduce Plasmodium levels. Here we review the prospects of using a Wolbachia-based approach to reduce human malaria transmission through transinfection of Anopheles mosquitoes.
Resumo:
This manual summarizes the roadside tree and brush control methods used by all of Iowa's 99 counties. It is based on interviews conducted in Spring 2002 with county engineers, roadside managers and others. The target audience of this manual is the novice county engineer or roadside manager. Iowa law is nearly silent on roadside tree and brush control, so individual counties have been left to decide on the level of control they want to achieve and maintain. Different solutions have been developed but the goal of every county remains the same: to provide safe roads for the traveling public. Counties in eastern and southern Iowa appear to face the greatest brush control challenge. Most control efforts can be divided into two categories: mechanical and chemical. Mechanical control includes cutting tools and supporting equipment. A chain saw is the most widely used cutting tool. Tractor mounted boom mowers and brush cutters are used to prune miles of brush but have significant safety and aesthetic limitations and boom mowers are easily broken by inexperienced operators. The advent of tree shears and hydraulic thumbs offer unprecedented versatility. Bulldozers are often considered a method of last resort since they reduce large areas to bare ground. Any chipper that violently grabs brush should not be used. Chemical control is the application of herbicide to different parts of a plant: foliar spray is applied to leaves; basal bark spray is applied to the tree trunk; a cut stump treatment is applied to the cambium ring of a cut surface. There is reluctance by many to apply herbicide into the air due to drift concerns. One-third of Iowa counties do not use foliar spray. By contrast, several accepted control methods are directed toward the ground. Freshly cut stumps should be treated to prevent resprouting. Basal bark spray is highly effective in sensitive areas such as near houses. Interest in chemical control is slowly increasing as herbicides and application methods are refined. Fall burning, a third, distinctly separate technique is underused as a brush control method and can be effective if timed correctly. In all, control methods tend to reflect agricultural patterns in a county. The use of chain saws and foliar sprays tends to increase in counties where row crops predominate, and boom mowing tends to increase in counties where grassland predominates. For counties with light to moderate roadside brush, rotational maintenance is the key to effective control. The most comprehensive approach to control is to implement an integrated roadside vegetation management (IRVM) program. An IRVM program is usually directed by a Roadside Manager whose duties may be shared with another position. Funding for control programs comes from the Rural Services Basic portion of a county's budget. The average annual county brush control budget is about $76,000. That figure is thought not to include shared expenses such as fuel and buildings. Start up costs for an IRVM program are less if an existing control program is converted. In addition, IRVM budgets from three different northeastern Iowa counties are offered for comparison in this manual. The manual also includes a chapter on temporary traffic control in rural work zones, a summary of the Iowa Code as it relates to brush control, and rules on avoiding seasonal disturbance of the endangered Indiana bat. Appendices summarize survey and forest cover data, an equipment inventory, sample forms for record keeping, a sample brush control policy, a few legal opinions, a literature search, and a glossary.
Resumo:
Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.
Resumo:
Control applications of switched mode power supplies have been widely investigated. The main objective ofresearch and development (R&D) in this field is always to find the most suitable control method to be implemented in various DC/DC converter topologies. Inother words, the goal is to select a control method capable of improving the efficiency of the converter, reducing the effect of disturbances (line and load variation), lessening the effect of EMI (electro magnetic interference), and beingless effected by component variation. The main objective of this research work is to study different control methods implemented in switched mode power supplies namely (PID control, hysteresis control, adaptive control, current programmed control, variable structure control (VSC), and sliding mode control (SMC). The advantages and drawbacks of each control method are given. Two control methods, the PID and the SMC are selected and their effects on DC/DC (Buck, Boost, and Buck-Boost) converters are examined. Matlab/SimulinkTM is used to implement PID control method in DC/DC Buck converter and SMC in DC/DC (Buck, and Buck Boost) converters. For the prototype, operational amplifiers (op-amps) are used to implement PID control in DC/DC Buck converter. For SMC op-amps are implemented in DC/DC Buck converter and dSPACETM is used to control the DC/DC Buck-Boost converter. The SMC can be applied to the DC/DC (Buck, Boost, and Buck-Boost) converters. A comparison of the effects of the PID control and the SMC on the DC/DC Buck converter response in steady state, under line variations, load variations, and different component variations is performed. Also the Conducted RF-Emissions between the PID and SMC DC/DC Buck Converter are compared. The thesis shows that, in comparison with the PID control, the SMC provides better steady-state response, better dynamic response, less EMI, inherent order reduction, robustness against system uncertainty disturbances, and an implicit stability proof. Giving a better steady-state and dynamic response, the SMC is implemented in a DC/DC resonant converter. The half-wave zero current switching (HWZCS) DC/DC Buck converter is selected as a converter topology. A general guideline to select the tank component values, needed for the designing of a HWZCS DC/DC Buck, is obtained. The implementation of the SMC to a HWZCS DC/DC Buck converter is analysed. The converter response is investigated in the steady-state region and in the dynamic region.
Resumo:
Se describen los métodos de muestreo, los umbrales de tolerancia y los métodos de control utilizados en un programa de control integrado de plagas de manzano basado en el control biológico de Panonychus ulmi Koch mediante Amblyseius andersoni Chant y en el empleo de productos selectivos cuando existen, contra el resto de las plagas, en Lleida. El programa se ha llevado a cabo en 6 fincas en las campañas 1989-90 y 1990-91. Sólo en un caso no se produjo control biológico de P. ulmi, siendo necesario un tratamiento acaricida. En general, los métodos de control del resto de las plagas han funcionado correctamente, aunque en algunos casos son tácticas conservadoras. Se discuten finalmente los distintos componentes del programa de control integrado y se señalan los objetivos del plan de trabajo futuro.
Resumo:
The need for high performance, high precision, and energy saving in rotating machinery demands an alternative solution to traditional bearings. Because of the contactless operation principle, the rotating machines employing active magnetic bearings (AMBs) provide many advantages over the traditional ones. The advantages such as contamination-free operation, low maintenance costs, high rotational speeds, low parasitic losses, programmable stiffness and damping, and vibration insulation come at expense of high cost, and complex technical solution. All these properties make the use of AMBs appropriate primarily for specific and highly demanding applications. High performance and high precision control requires model-based control methods and accurate models of the flexible rotor. In turn, complex models lead to high-order controllers and feature considerable computational burden. Fortunately, in the last few years the advancements in signal processing devices provide new perspective on the real-time control of AMBs. The design and the real-time digital implementation of the high-order LQ controllers, which focus on fast execution times, are the subjects of this work. In particular, the control design and implementation in the field programmable gate array (FPGA) circuits are investigated. The optimal design is guided by the physical constraints of the system for selecting the optimal weighting matrices. The plant model is complemented by augmenting appropriate disturbance models. The compensation of the force-field nonlinearities is proposed for decreasing the uncertainty of the actuator. A disturbance-observer-based unbalance compensation for canceling the magnetic force vibrations or vibrations in the measured positions is presented. The theoretical studies are verified by the practical experiments utilizing a custom-built laboratory test rig. The test rig uses a prototyping control platform developed in the scope of this work. To sum up, the work makes a step in the direction of an embedded single-chip FPGA-based controller of AMBs.
Resumo:
Direct torque control (DTC) is a new control method for rotating field electrical machines. DTC controls directly the motor stator flux linkage with the stator voltage, and no stator current controllers are used. With the DTC method very good torque dynamics can be achieved. Until now, DTC has been applied to asynchronous motor drives. The purpose of this work is to analyse the applicability of DTC to electrically excited synchronous motor drives. Compared with asynchronous motor drives, electrically excited synchronous motor drives require an additional control for the rotor field current. The field current control is called excitation control in this study. The dependence of the static and dynamic performance of DTC synchronous motor drives on the excitation control has been analysed and a straightforward excitation control method has been developed and tested. In the field weakening range the stator flux linkage modulus must be reduced in order to keep the electro motive force of the synchronous motor smaller than the stator voltage and in order to maintain a sufficient voltage reserve. The dynamic performance of the DTC synchronous motor drive depends on the stator flux linkage modulus. Another important factor for the dynamic performance in the field weakening range is the excitation control. The field weakening analysis considers both dependencies. A modified excitation control method, which maximises the dynamic performance in the field weakening range, has been developed. In synchronous motor drives the load angle must be kept in a stabile working area in order to avoid loss of synchronism. The traditional vector control methods allow to adjust the load angle of the synchronous motor directly by the stator current control. In the DTC synchronous motor drive the load angle is not a directly controllable variable, but it is formed freely according to the motor’s electromagnetic state and load. The load angle can be limited indirectly by limiting the torque reference. This method is however parameter sensitive and requires a safety margin between the theoretical torque maximum and the actual torque limit. The DTC modulation principle allows however a direct load angle adjustment without any current control. In this work a direct load angle control method has been developed. The method keeps the drive stabile and allows the maximal utilisation of the drive without a safety margin in the torque limitation.
Resumo:
In this doctoral thesis, a power conversion unit for a 10 kWsolid oxide fuel cell is modeled, and a suitable control system is designed. The need for research was identified based on an observation that there was no information available about the characteristics of the solid oxide fuel cell from the perspective of power electronics and the control system, and suitable control methods had not previously been studied in the literature. In addition, because of the digital implementation of the control system, the inherent characteristics of the digital system had to be taken into account in the characteristics of the solid oxide fuel cell (SOFC). The characteristics of the solid oxide fuel cell as well the methods for the modeling and control of the DC/DC converter and the grid converter are studied by a literature survey. Based on the survey, the characteristics of the SOFC as an electrical power source are identified, and a solution to the interfacing of the SOFC in distributed generation is proposed. A mathematical model of the power conversion unit is provided, and the control design for the DC/DC converter and the grid converter is made based on the proposed interfacing solution. The limit cycling phenomenon is identified as a source of low-frequency current ripple, which is found to be insignificant when connected to a grid-tied converter. A method to mitigate a second harmonic originating from the grid interface is proposed, and practical considerations of the operation with the solid oxide fuel cell plant are presented. At the theoretical level, the thesis discusses and summarizes the methods to successfully derive a model for a DC/DC converter, a grid converter, and a power conversion unit. The results of this doctoral thesis can also be used in other applications, and the models and methods can be adopted to similar applications such as photovoltaic systems. When comparing the results with the objectives of the doctoral thesis, we may conclude that the objectives set for the work are met. In this doctoral thesis, theoretical and practical guidelines are presented for the successful control design to connect a SOFC-based distributed generation plant to the utility grid.