990 resultados para Contrast media


Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To compare volume-targeted and whole-heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. MATERIALS AND METHODS: Six healthy adult subjects underwent a navigator-gated and -corrected (NAV) free breathing volume-targeted cardiac-triggered inversion recovery (IR) 3D steady-state free precession (SSFP) coronary MRA sequence (t-CMRA) (spatial resolution = 1 x 1 x 3 mm(3)) and high spatial resolution IR 3D SSFP whole-heart coronary MRA (WH-CMRA) (spatial resolution = 1 x 1 x 2 mm(3)) after the administration of an intravascular contrast agent B-22956. Subjective and objective image quality parameters including maximal visible vessel length, vessel sharpness, and visibility of coronary side branches were evaluated for both t-CMRA and WH-CMRA. RESULTS: No significant differences (P = NS) in image quality were observed between contrast-enhanced t-CMRA and WH-CMRA. However, using an intravascular contrast agent, significantly longer vessel segments were measured on WH-CMRA vs. t-CMRA (right coronary artery [RCA] 13.5 +/- 0.7 cm vs. 12.5 +/- 0.2 cm; P < 0.05; and left circumflex coronary artery [LCX] 11.9 +/- 2.2 cm vs. 6.9 +/- 2.4 cm; P < 0.05). Significantly more side branches (13.3 +/- 1.2 vs. 8.7 +/- 1.2; P < 0.05) were visible for the left anterior descending coronary artery (LAD) on WH-CMRA vs. t-CMRA. Scanning time and navigator efficiency were similar for both techniques (t-CMRA: 6.05 min; 49% vs. WH-CMRA: 5.51 min; 54%, both P = NS). CONCLUSION: Both WH-CMRA and t-CMRA using SSFP are useful techniques for coronary MRA after the injection of an intravascular blood-pool agent. However, the vessel conspicuity for high spatial resolution WH-CMRA is not inferior to t-CMRA, while visible vessel length and the number of visible smaller-diameter vessels and side-branches are improved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To evaluate gadocoletic acid (B-22956), a gadolinium-based paramagnetic blood pool agent, for contrast-enhanced coronary magnetic resonance angiography (MRA) in a Phase I clinical trial, and to compare the findings with those obtained using a standard noncontrast T2 preparation sequence. MATERIALS AND METHODS: The left coronary system was imaged in 12 healthy volunteers before B-22956 application and 5 (N = 11) and 45 (N = 7) minutes after application of 0.075 mmol/kg of body weight (BW) of B-22956. Additionally, imaging of the right coronary system was performed 23 minutes after B-22956 application (N = 6). A three-dimensional gradient echo sequence with T2 preparation (precontrast) or inversion recovery (IR) pulse (postcontrast) with real-time navigator correction was used. Assessment of the left and right coronary systems was performed qualitatively (a 4-point visual score for image quality) and quantitatively in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, visible vessel length, maximal luminal diameter, and the number of visible side branches. RESULTS: Significant (P < 0.01) increases in SNR (+42%) and CNR (+86%) were noted five minutes after B-22956 application, compared to precontrast T2 preparation values. A significant increase in CNR (+40%, P < 0.05) was also noted 45 minutes postcontrast. Vessels (left anterior descending artery (LAD), left coronary circumflex (LCx), and right coronary artery (RCA)) were also significantly (P < 0.05) sharper on postcontrast images. Significant increases in vessel length were noted for the LAD (P < 0.05) and LCx and RCA (both P < 0.01), while significantly more side branches were noted for the LAD and RCA (both P < 0.05) when compared to precontrast T2 preparation values. CONCLUSION: The use of the intravascular contrast agent B-22956 substantially improves both objective and subjective parameters of image quality on high-resolution three-dimensional coronary MRA. The increase in SNR, CNR, and vessel sharpness minimizes current limitations of coronary artery visualization with high-resolution coronary MRA.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Specifically we aim to demonstrate that the results of our earlier safety data hold true in this much larger multi-national and multi-ethnical population. BACKGROUND: We sought to re-evaluate the frequency, manifestations, and severity of acute adverse reactions associated with administration of several gadolinium- based contrast agents during routine CMR on a European level. METHODS: Multi-centre, multi-national, and multi-ethnical registry with consecutive enrolment of patients in 57 European centres. RESULTS: During the current observation 37,788 doses of Gadolinium based contrast agent were administered to 37,788 patients. The mean dose was 24.7 ml (range 5-80 ml), which is equivalent to 0.123 mmol/kg (range 0.01 - 0.3 mmol/kg). Forty-five acute adverse reactions due to contrast administration occurred (0.12%). Most reactions were classified as mild (43 of 45) according to the American College of Radiology definition. The most frequent complaints following contrast administration were rashes and hives (15 of 45), followed by nausea (10 of 45) and flushes (10 of 45). The event rate ranged from 0.05% (linear non-ionic agent gadodiamide) to 0.42% (linear ionic agent gadobenate dimeglumine). Interestingly, we also found different event rates between the three main indications for CMR ranging from 0.05% (risk stratification in suspected CAD) to 0.22% (viability in known CAD). CONCLUSIONS: The current data indicate that the results of the earlier safety data hold true in this much larger multi-national and multi-ethnical population. Thus, the "off-label" use of Gadolinium based contrast in cardiovascular MR should be regarded as safe concerning the frequency, manifestation and severity of acute events.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To evaluate the necessity of the non contrast-enhanced phase in abdominal computed tomography scans. Materials and Methods: A retrospective, cross-sectional, observational study was developed, evaluating 244 consecutive abdominal computed tomography scans both with and without contrast injection. Initially, the contrast-enhanced images were analyzed (first analysis). Subsequently, the observers had access to the non-contrast-enhanced images for a second analysis. The primary and secondary diagnoses were established as a function of the clinical indications for each study (such as tumor staging, acute abdomen, investigation for abdominal collection and hepatocellular carcinoma, among others). Finally, the changes in the diagnoses resulting from the addition of the non-contrast-enhanced phase were evaluated. Results: Only one (0.4%; p > 0.999; non-statistically significant) out of the 244 reviewed cases had the diagnosis changed after the reading of non-contrast-enhanced images. As the secondary diagnoses are considered, 35 (14%) cases presented changes after the second analysis, as follows: nephrolithiasis (10%), steatosis (3%), adrenal nodule (0.7%) and cholelithiasis (0.3%). Conclusion: For the clinical indications of tumor staging, acute abdomen, investigation of abdominal collections and hepatocellular carcinoma, the non-contrast-enhanced phase can be excluded from abdominal computed tomography studies with no significant impact on the diagnosis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Recent studies have demonstrated that the use of paramagnetic hepatobiliary contrast agents in the acquisition of magnetic resonance images remarkably improves the detection and differentiation of focal liver lesions, as compared with extracellular contrast agents. Paramagnetic hepatobiliary contrast agents initially show the perfusion of the lesions, as do extracellular agents, but delayed contrast-enhanced images can demonstrate contrast uptake by functional hepatocytes, providing further information for a better characterization of the lesions. Additionally, this intrinsic characteristic increases the accuracy in the detection of hepatocellular carcinomas and metastases, particularly the small-sized ones. Recently, a hepatobiliary contrast agent called gadolinium ethoxybenzyl dimeglumine, that is simply known as gadoxetic acid, was approved by the National Health Surveillance Agency for use in humans. The authors present a literature review and a practical approach of magnetic resonance imaging utilizing gadoxetic acid as contrast agent, based on patients' images acquired during their initial experiment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective:To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality.Materials and Methods:Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration.Results:As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions.Conclusion:Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Contrast-induced nephropathy is a common complication of radiographic procedures. Different measures have been used to avoid this damage, but the evidence is controversial. New investigations are required to clarify it. We investigated the efficacy and safety of sodium bicarbonate solution compared with sodium chloride solution to prevent contrast induced nephropathy in patients with or at risk of renal dysfunction. Methods: A prospective, single-center, randomized clinical trial conducted from May 1, 2007 to February 8, 2008. Inpatients in a tertiary center, scheduled to undergo a procedure with the nonionic radiographic contrast agent iohexol. There were 220 patients with serum creatinine levels of at least 1.2 mg/dL (106.1 µmol/L) and/or type 2 diabetics, who were randomized to receive an infusion of sodium chloride (n = 113) or sodium bicarbonate (n = 107) before and after contrast dye administration. The intervention were "A" group received 1 ml/kg/hour of normal saline solution, starting 12 hours before and continuing 12 hours after iohexol contrast. "B" group received 3 ml/kg of sodium bicarbonate solution (150 mEq/L) one hour prior to procedure and then drip rate was decreased to 1 ml/kg/hour until 6 hours post procedure. Our main outcome measure was change in serum creatinine. Results: The mean creatinine value after the procedure was 1.26 mg/dL in the saline group and 1.22 mg/dL in the bicarbonate group (mean difference: 0.036; CI 95%: -0.16 to 0.23, p = 0.865). The diagnosis of contrast-induced nephropathy, defined by increase in serum creatinine on 25% or more within 2 days after administration of radiographic contrast, was done in twelve patients (12%) in the bicarbonate group and eighth patients (7.1%) in the saline group (RR: 1.68, CI 95%: 0.72 to 3.94). Conclusion: Our investigation showed that there were no differences between normal saline solution (extended infusion) vs. bicarbonate solution for nephroprotection.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Contrast induced nephropathy (CIN) is one of the complications of the use of intravascular contrast agents, being defined as a reduction of the glomerular filtration rate caused by the iodinated contrast. Most CIN data derive from the cardiovascular literature, which identified as the most consistent risk factors pre-existing chronic renal insufficiency and diabetes mellitus. However, these studies limit their conclusions to a more specific patient population. Computerized tomography as a cause of CIN has been studied less often. Objective: To report on the incidence of computerized tomography contrast induced nephropathy (CIN) in an inpatient population of a tertiary general hospital, identifying potentially avoidable risk factors. Methods: We performed a prospective cohort study with inpatients admitted at a tertiary hospital requiring contrast-induced CT. The primary outcome was the development of CIN, measure by the alteration of serum creatinine or glomerular filtration rate in 48 or 72 hours. Through clinical interview, we verified possible risk factors and preventive measures instituted by the medical team and their association with development of CIN. Results: Of a total of 410 patients, 35 (8.5%) developed CIN. There was a positive correlation between CIN and the presence of diabetes mellitus (OR = 2.15; 95%CI 1.35-4.06; p = 0.02), heart failure (OR = 2.23; 95%CI 1.18-8.8; p = 0.022), and renal failure (OR = 3.36; 95%CI 1.57- 7.17; p = 0.002) Conclusion: Incidence of CIN varies according to the population. Diabetes mellitus, heart failure and renal failure were independent risk factors for the development of CT-associated CIN. Further studies are needed to better understand and treat CT-associated CIN.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Introduction: Contrast induced nephropathy is the third most prevalent preventable cause of acute kidney injury in hospitalized patients. It defined as an absolute increase in serum creatinine ≥ 0.5 mg/dL and relative ≥ 25% increase. Objective: We studied the risk factors to intravenous injection contrast nephropathy after computed tomography. Methods: We studied 400 patients prospectively. Results: The incidence of contrast induced nephropathy, with an absolute or a relative increase were 4.0% and 13.9%, respectively. Diabetes and cardiac failure were independent risk factors for CIN a relative increase de serum creatinine (O.R.: 3.5 [95% CI: 1.92-6.36], p < 0.01, 2.61 [95% CI: 1.14-6.03%], p < 0.05, respectively). Conclusions: We showed association between uses of intravenous injection contrast after computed tomography with acute injury renal, notably with diabetes and heart failure.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In order to assess experimentally the usefulness of some procedures employed in man to prevent venous thrombosis following phlebography, thrombosis was induced in rats using sodium diatrizoate in a temporarily isolated segment of a jugular vein. The prevention of thrombosis was attempted by washing out the vein with physiologic saline or saline plus heparin or by injecting saline plus heparin in the opposite jugular vein. Thrombosis occurred in all animals in the control group and in the group treated with saline alone. Both treatment schemes with heparin significantly reduced the incidence of thrombosis, the wash out with heparin being more effective than systemic heparin.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background. Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. Method. A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n=7) or 15 min (group 2; n=7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview®; Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. Results. Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. Conclusion. Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications.