968 resultados para Constant amplitude


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective - To investigate visual habituation – a measure of visual cortical excitability – in photosensitive patients in pediatric age and compare the findings with a matched sample with idiopathic generalized epilepsies without photosensitivity and with normally developing children. Methods - We presented a full-field black-and-white checkerboard pattern, at 3 reversal/s with 100% contrast binocularly for 600 consecutive trials and measured the N75–P100 and P100–N145 pattern-reversal visual evoked potential inter-peak amplitudes and N75, P100, N145 latencies for the six blocks of 100 responses. As a measure of habituation we used the slope of the linear regression line of the N75–P100 and P100–N145 peak-to-peak amplitudes. The slope of the linear regression line of the N75–P100 and P100–N145 latencies was also analyzed. Results - Statistical analysis revealed significant differences between the three groups in the slope index of N75–P100 PR-VEP amplitude, with increased or constant amplitude in the PS group compare to the IGE and ND across the six blocks. Conclusions - Our results support the notion that photosensitivity is associated with altered control of excitatory and inhibitory cortical processes. The causal relationship between habituation deficit and photo-paroxysmal response needs to be further investigated with longitudinal studies. Significance This study supports the hypothesis that suppression of PR-VEP is a sensitive intermediate phenotype, which discriminates patients with photosensitivity from those with generalized epilepsies in pediatric age.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study is to highlight the relation between muscle motion and electromyographyc activity during whole body vibration. This treatment is accounted for eliciting a reflex muscle activity in response to vibratory stimulation. Simultaneous recordings from quadriceps Rectus Femoris EMG and 3D muscle accelerations on fifteen subjects undergoing vibration treatments were collected. In our study vibrations were delivered via a sinusoidal oscillating platform at different frequencies (10-45 Hz), with a constant amplitude. Muscle motion was estimated by processing accelerometer data. Displacements revealed a mechanical resonant-like behaviour of the muscle; resonance frequencies and dumping factors depended on subject. Large EMG motion artifacts were removed using sharp notch filters centred at the vibration frequency and its superior harmonics. RMS values of artifact-free EMG were found correlated to the actual muscle displacement. The results were in accordance to the hypothesis of a proprioceptive response during vibration treatment. Nevertheless, motion artifacts produced an overestimation of muscle activity, therefore its removal was essential. © 2009 Springer Berlin Heidelberg.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract: We present an optical sensing methodology to estimate the fatigue damage stateof structures made of carbon fiber reinforced polymer (CFRP), by measuring variations on the surface roughness. Variable amplitude loads (VAL), which represent realistic loads during aeronautical missions of fighter aircraft (FALSTAFF) have been applied to coupons until failure. Stiffness degradation and surface roughness variations have been measured during the life of the coupons obtaining a Pearson correlation of 0.75 between both variables. The data were compared with a previous study for Constant Amplitude Load (CAL) obtaining similar results. Conclusions suggest that the surface roughness measured in strategic zones is a useful technique for structural health monitoring of CFRP structures, and that it is independent of the type of load applied. Surface roughness can be measured in the field by optical techniques such as speckle, confocal perfilometers and interferometry, among others.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents an optical non-contact technique to evaluate the fatigue damage state of CFRP structures measuring the irregularity factor of the surface. This factor includes information about surface topology and can be measured easily on field, by techniques such as optical perfilometers. The surface irregularity factor has been correlated with stiffness degradation, which is a well-accepted parameter for the evaluation of the fatigue damage state of composite materials. Constant amplitude fatigue loads (CAL) and realistic variable amplitude loads (VAL), representative of real in- flight conditions, have been applied to “dog bone” shaped tensile specimens. It has been shown that the measurement of the surface irregularity parameters can be applied to evaluate the damage state of a structure, and that it is independent of the type of fatigue load that has caused the damage. As a result, this measurement technique is applicable for a wide range of inspections of composite material structures, from pressurized tanks with constant amplitude loads, to variable amplitude loaded aeronautical structures such as wings and empennages, up to automotive and other industrial applications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Hitsattujen rakenteiden väsymiskestävyyttä pystytään parantamaan jälkikäsittelymenetelmillä, joistayksi, ultraäänikäsittely muokkaa hitsin geometriaa ja aiheuttaa puristusjäännösjännitystilan. Tässä tutkimuksessa verrataan kokeellisesti kuormaa kantamattoman hitsatun ja ui -käsitellyn rivan väsymislujuutta toisiinsa. Tutkimusohjelmaan kuuluu kahta teräslajia ja sekä vakio - että vaihtuva - amplitudista kuormitusta. Ultraäänikäsittelyllä saavutetaan väsymiskestoiän parantuminen vakio - ja vaihtuva - amplitudisella kuormituksella. Perusaineen lujuudella ei ole merkittää vaikutusta väsymislujuuteen kun liitos on hitsatussa tilassa. Tällöin väsymiskestävyyden määrää hitsin rajaviivan jännityskeskittymä. Ultraäänikäsitellyn hitsatunliitoksen väsymiskestävyys on suurempi korkeamman lujuuden omaavilla teräksillä. Tästä syystä korkealujuuksisten terästen käyttö ultraäänikäsiteltynä väsyttävästi kuormitetuissa kevytrakenteissa on perusteltua.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple constant-current electrocutaneous stimulator for high-impedance loads using low-cost, standard high-voltage components is presented. A voltage-regulator powers an oscillator built across the primary of a transformer whose secondary delivers, after rectification, the high-voltage supply to switched current-mirrors in the driving stage. Since the compliance high-voltage is proportional to the stimulation current, overall power consumption is minimized. By adjusting the regulated voltage, control of the pulsed-current amplitude is achieved. A prototype with readily available components features stimulation currents of amplitude and pulsewidth in the range 0≤Iskin≤20mA and 50μs ≤Tpulse≤1ms, respectively. Pulse-repetition spans from 1 Hz to 10Hz. Worst-case ripple is 3.7% @Iskin=1mA. Measured pulse fall-time is shorter than 32μs. Overall consumption is 4.4W @Iskin=20mA. Subject isolation from line is 4KV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The contribution of respiratory muscle work to the development of the O(2) consumption (Vo(2)) slow component is a point of controversy because it has been shown that the increased ventilation in hypoxia is not associated with a concomitant increase in Vo(2) slow component. The first purpose of this study was thus to test the hypothesis of a direct relationship between respiratory muscle work and Vo(2) slow component by manipulating inspiratory resistance. Because the conditions for a Vo(2) slow component specific to respiratory muscle can be reached during intense exercise, the second purpose was to determine whether respiratory muscles behave like limb muscles during heavy exercise. Ten trained subjects performed two 8-min constant-load heavy cycling exercises with and without a threshold valve in random order. Vo(2) was measured breath by breath by using a fast gas exchange analyzer, and the Vo(2) response was modeled after removal of the cardiodynamic phase by using two monoexponential functions. As anticipated, when total work was slightly increased with loaded inspiratory resistance, slight increases in base Vo(2), the primary phase amplitude, and peak Vo(2) were noted (14.2%, P < 0.01; 3.5%, P > 0.05; and 8.3%, P < 0.01, respectively). The bootstrap method revealed small coefficients of variation for the model parameter, including the slow-component amplitude and delay (15 and 19%, respectively), indicating an accurate determination for this critical parameter. The amplitude of the Vo(2) slow component displayed a 27% increase from 8.1 +/- 3.6 to 10.3 +/- 3.4 ml. min(-1). kg(-1) (P < 0.01) with the addition of inspiratory resistance. Taken together, this increase and the lack of any differences in minute volume and ventilatory parameters between the two experimental conditions suggest the occurrence of a Vo(2) slow component specific to the respiratory muscles in loaded condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies periodic traveling gravity waves at the free surface of water in a flow of constant vorticity over a flat bed. Using conformal mappings the free-boundary problem is transformed into a quasilinear pseudodifferential equation for a periodic function of one variable. The new formulation leads to a regularity result and, by use of bifurcation theory, to the existence of waves of small amplitude even in the presence of stagnation points in the flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho tem por objetivo a aplicação de um método de migração com amplitudes verdadeiras, considerando-se um meio acústico onde a velocidade de propagação varia linearmente com a profundidade. O método de migração é baseado na teoria dos raios e na integral de migração de Kirchhoff, procurando posicionar de forma correta os refletores e recuperar os respetivos coeficientes de reflexão. No processo de recuperação dos coeficientes de reflexão, busca-se corrigir o fator de espalhamento geométrico de reflexões sísmicas primárias, sem o conhecimento a priori dos refletores procurados. Ao considerar-se configurações fonte-receptor arbitrárias, as reflexões primárias podem ser imageadas no tempo ou profundidade, sendo as amplitudes do campo de ondas migrado uma medida dos coeficientes de reflexão (função do ângulo de incidência). Anteriormente têm sido propostos alguns algoritmos baseados na aproximação de Born ou Kirchhoff. Todos são dados em forma de um operador integral de empilhamento de difrações, que são aplicados à entrada dos dados sísmicos. O resultado é uma seção sísmica migrada, onde cada ponto de reflexão é imageado com uma amplitude proporcional ao coeficiente de reflexão no ponto. No presente caso, o processo de migração faz uso de um modelo com velocidade que apresenta uma distribuição que varia linearmente com a profundidade, conhecido também como gradiente constante de velocidade. O esquema de migração corresponde a uma versão modificada da migração de empilhamento por difração e faz uso explícito da teoria do raio, por exemplo, na descrição de tempos de trânsito e amplitudes das reflexões primárias, com as quais a operação de empilhamento e suas propriedades podem ser entendidas geometricamente. Efeitos como o espalhamento geométrico devido à trajetória do raio levam a distorção das amplitudes. Estes efeitos têm que ser corregidos durante o processamento dos dados sísmicos. Baseados na integral de migração de Kirchhoff e na teoria paraxial dos raios, foi derivada a função peso e o operador da integral por empilhamento de difrações para um modelo sísmico 2,5-D, e aplicado a uma serie de dados sintéticos em ambientes com ruído e livre de ruído. O resultado mostra a precisão e estabilidade do método de migração em um meio 2,5-D como ferramenta para obter informação sobre as propriedades de refletividade da subsuperfície da terra. Neste método não são levados em consideração a existência de caústicas nem a atenuação devido a fricção interna.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUÇÃO: A determinação dos domínios de intensidade de exercício tem importantes implicações na prescrição do treino aeróbio e na elaboração de delineamentos experimentais. OBJETIVO: Analisar os efeitos do nível de aptidão aeróbia sobre a amplitude dos domínios de intensidade de exercício durante o ciclismo. MÉTODOS: Doze ciclistas (CIC), 11 corredores (COR) e oito indivíduos não treinados (NT) foram submetidos aos seguintes protocolos em diferentes dias: 1) teste progressivo para determinação do limiar de lactato (LL), consumo máximo de oxigênio (VO2máx) e sua respectiva intensidade (IVO2máx); 2) três testes de carga constante até a exaustão a 95, 100 e 110% IVO2máx para a determinação da potência crítica (PC); 3) testes até a exaustão para determinar a intensidade superior do domínio severo (Isup). As amplitudes dos domínios (moderado < LL; LL > pesado < PC; PC > severo < Isup) foram expressas como percentual da Isup (VO2). RESULTADOS: A amplitude do domínio moderado foi similar entre CIC (52 ± 8%) e COR (47 ± 4%) e significantemente maior no CIC em relação ao NT (41 ± 7%). O domínio pesado foi significantemente menor no CIC (17 ± 6%) em relação ao COR (27 ± 6%) e NT (27 ± 9%). Em relação ao domínio severo não foram encontradas diferenças significantes entre os CIC (31 ± 7%), COR (26 ± 5%) e NT (31 ± 7%). CONCLUSÃO: O domínio pesado de exercício é mais sensível a mudanças determinadas pelo nível de aptidão aeróbia, existindo a necessidade de que se atenda ao princípio da especificidade do movimento, quando se pretende obter um elevado grau de adaptação fisiológica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During short-term postural changes, the factors determining the amplitude of intracranial pulse pressure (ICPPA) remain constant, except for cerebrovascular resistance (CVR). Therefore, it may be possible to draw conclusions from the ICPPA onto the cerebrovascular resistance (CVR) and thus the relative change in cerebral perfusion pressure (CPP).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparison of a constant (continuous delivery of 4% FiO(2)) and a variable (initial 5% FiO(2) with adjustments to induce low amplitude EEG (LAEEG) and hypotension) hypoxic/ischemic insult was performed to determine which insult was more effective in producing a consistent degree of survivable neuropathological damage in a newborn piglet model of perinatal asphyxia. We also examined which physiological responses contributed to this outcome. Thirty-nine 1-day-old piglets were subjected to either a constant hypoxic/ischemic insult of 30- to 37-min duration or a variable hypoxic/ischemic insult of 30-min low peak amplitude EEG (LAEEG < 5 mu V) including 10 min of low mean arterial blood pressure (MABP < 70% of baseline). Control animals (n = 6) received 21% FiO(2) for the duration of the experiment. At 72 h, the piglets were euthanased, their brains removed and fixed in 4% paraformaldehyde and assessed for hypoxic/ischemic injury by histological analysis. Based on neuropathology scores, piglets were grouped as undamaged or damaged; piglets that did not survive to 72 h were grouped separately as dead. The variable insult resulted in a greater number of piglets with neuropathological damage (undamaged = 12.5%, damaged = 68.75%, dead = 18.75%) while the constant insult resulted in a large proportion of undamaged piglets (undamaged = 50%, damaged = 22.2%, dead = 27.8%). A hypoxic insult varied to maintain peak amplitude EEG < 5 mu V results in a greater number of survivors with a consistent degree of neuropathological damage than a constant hypoxic insult. Physiological variables MABP, LAEEG, pH and arterial base excess were found to be significantly associated with neuropathological outcome. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When a textured surface is modulated in depth and illuminated, parts of the surface receive different levels of illumination; the resulting variations in luminance can be used to infer the shape of the depth modulations-shape from shading. The changes in illumination also produce changes in the amplitude of the texture, although local contrast remains constant. We investigated the role of texture amplitude in supporting shape from shading. If a luminance plaid is added to a binary noise texture (LM), shape from shading produces perception of corrugations in two directions. If the amplitude of the noise is also modulated (AM) such that it is in-phase with one of the luminance sinusoids and out-of-phase with the other, the resulting surface is seen as corrugated in only one directionöthat supported by the in-phase pairing. We confirmed this subjective report experimentally, using a depth-mapping technique. Further, we asked naïve observers to indicate the direction of corrugations in plaids made up of various combinations of LM and AM. LM+AM was seen as having most depth, then LM-only, then LM-AM, and then AM-only. Our results suggest that while LM is required to see depth from shading, its phase relative to any AM component is also important.