922 resultados para Computerized
Resumo:
The objectives of the present study were 1) to compare results obtained by the traditional manual method of measuring heart rate (HR) and heart rate response (HRR) to the Valsalva maneuver, standing and deep breathing, with those obtained using a computerized data analysis system attached to a standard electrocardiograph machine; 2) to standardize the responses of healthy subjects to cardiovascular tests, and 3) to evaluate the response to these tests in a group of patients with diabetes mellitus (DM). In all subjects (97 healthy and 143 with DM) we evaluated HRR to deep breathing, HRR to standing, HRR to the Valsalva maneuver, and blood pressure response (BPR) to standing up and to a sustained handgrip. Since there was a strong positive correlation between the results obtained with the computerized method and the traditional method, we conclude that the new method can replace the traditional manual method for evaluating cardiovascular responses with the advantages of speed and objectivity. HRR and BPR of men and women did not differ. A correlation between age and HRR was observed for standing (r = -0.48, P<0.001) and deep breathing (r = -0.41, P<0.002). Abnormal BPR to standing was usually observed only in diabetic patients with definite and severe degrees of autonomic neuropathy.
Resumo:
Concentration-response curves of isometric tension studies on isolated blood vessels are obtained traditionally. Although parameters such as Imax, EC50 and pA2 may be readily calculated, this method does not provide information on the temporal profile of the responses or the actual nature of the reaction curves. Computerized data acquisition systems can be used to obtain average data that represent a new source of otherwise inaccessible information, since early and late responses may be observed separately in detail
Resumo:
Arterial baroreflex sensitivity estimated by pharmacological impulse stimuli depends on intrinsic signal variability and usually a subjective choice of blood pressure (BP) and heart rate (HR) values. We propose a semi-automatic method to estimate cardiovascular reflex sensitivity to bolus infusions of phenylephrine and nitroprusside. Beat-to-beat BP and HR time series for male Wistar rats (N = 13) were obtained from the digitized signal (sample frequency = 2 kHz) and analyzed by the proposed method (PRM) developed in Matlab language. In the PRM, time series were low-pass filtered with zero-phase distortion (3rd order Butterworth used in the forward and reverse direction) and presented graphically, and parameters were selected interactively. Differences between basal mean values and peak BP (deltaBP) and HR (deltaHR) values after drug infusions were used to calculate baroreflex sensitivity indexes, defined as the deltaHR/deltaBP ratio. The PRM was compared to the method traditionally (TDM) employed by seven independent observers using files for reflex bradycardia (N = 43) and tachycardia (N = 61). Agreement was assessed by Bland and Altman plots. Dispersion among users, measured as the standard deviation, was higher for TDM for reflex bradycardia (0.60 ± 0.46 vs 0.21 ± 0.26 bpm/mmHg for PRM, P < 0.001) and tachycardia (0.83 ± 0.62 vs 0.28 ± 0.28 bpm/mmHg for PRM, P < 0.001). The advantage of the present method is related to its objectivity, since the routine automatically calculates the desired parameters according to previous software instructions. This is an objective, robust and easy-to-use tool for cardiovascular reflex studies.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Resumo:
Introduction: Contrast induced nephropathy (CIN) is one of the complications of the use of intravascular contrast agents, being defined as a reduction of the glomerular filtration rate caused by the iodinated contrast. Most CIN data derive from the cardiovascular literature, which identified as the most consistent risk factors pre-existing chronic renal insufficiency and diabetes mellitus. However, these studies limit their conclusions to a more specific patient population. Computerized tomography as a cause of CIN has been studied less often. Objective: To report on the incidence of computerized tomography contrast induced nephropathy (CIN) in an inpatient population of a tertiary general hospital, identifying potentially avoidable risk factors. Methods: We performed a prospective cohort study with inpatients admitted at a tertiary hospital requiring contrast-induced CT. The primary outcome was the development of CIN, measure by the alteration of serum creatinine or glomerular filtration rate in 48 or 72 hours. Through clinical interview, we verified possible risk factors and preventive measures instituted by the medical team and their association with development of CIN. Results: Of a total of 410 patients, 35 (8.5%) developed CIN. There was a positive correlation between CIN and the presence of diabetes mellitus (OR = 2.15; 95%CI 1.35-4.06; p = 0.02), heart failure (OR = 2.23; 95%CI 1.18-8.8; p = 0.022), and renal failure (OR = 3.36; 95%CI 1.57- 7.17; p = 0.002) Conclusion: Incidence of CIN varies according to the population. Diabetes mellitus, heart failure and renal failure were independent risk factors for the development of CT-associated CIN. Further studies are needed to better understand and treat CT-associated CIN.
Resumo:
Nowadays, image analysis is one of the most modern tools in evaluating physiological potential of seeds. This study aimed at verifying the efficiency of the seedling imaging analysis to assess physiological potential of wheat seeds. The seeds of wheat, cultivars IAC 370 and IAC 380, each of which represented by five different lots, were stored during four months under natural environmental conditions of temperature (T) and relative humidity (RH), in municipality of Piracicaba, Stated of São Paulo, Brazil. For this, bimonthly assessments were performed to quantify moisture content and physiological potential of seeds by means of tests of: germination, first count, accelerated aging, electrical conductivity, seedling emergence, and computerized analysis of seedlings, using the Seed Vigor Imaging System (SVIS®). It has been concluded that the computerized analyses of seedling through growth indexes and vigor, using the SVIS®, is efficient to assess physiological potential of wheat seeds.
Resumo:
The use of information and communication technologies in the health and social service sectors, and the development of multi-centred and international research networks present many benefits for society: for example, better follow-up on an individual’s states of health, better quality of care, better control of expenses, and better communication between healthcare professionals. However, this approach raises issues relative to the protection of privacy: more specifically, to the processing of individual health information.
Resumo:
Resumen tomado de la publicaci??n
Resumo:
Resumen tomado de la publicaci??n
Resumo:
This study assessed visual working memory through Memonum computerized test in schoolchildren. The effects of three exposure times (1, 4 and 8 seconds) have been evaluated, and the presentation of a distractor on the mnemonic performance in the test Memonum in 72 children from a college in the metropolitan area of Bucaramanga, Colombia, aged between 8 and 11 in grades third, fourth and fifth grade. It has been found significant difference regarding the exposure time in the variables number of hits and successes accumulated, showing a better mnemonic performance in participants who took the test during 8 seconds compared to children who took the test during 1 second; in addition, the presence of a distractor showed a significant difference regarding the strengths and successes accumulated. Such distractor is considered a stimulus generator interference that disrupts the storage capacity of working memory in children. Additionally, a significant difference was found with respect to the use of mental rehearsal strategy, indicating that participants who took the test in 4 and 8 seconds, respectively, assigned higher scores than children who took the test in 1 second. A long exposure time to stimuli during Memonum test increases the holding capacity. Also, the use of a distractor affects the storage capacity and this, at the same time, increases the school progression due to the use of mnemonic strategies that children use to ensure the memory of the numerical series
Resumo:
El contexto teórico y empírico de esta investigación sobre entonación, se enmarca dentro de la filosofía lingüística de la teoría sistémico-funcional. El modelo metodológico empleado se basa en la Lingüística de Corpus. La descripción de la adquisición y aprendizaje de la lengua extranjera está justificada dentro del marco teórico de la teoría de interlengua y la adquisición de segundas lenguas y lenguas extranjeras.. El presente estudio del corpus comparativo y longitudinal de aprendices y hablantes nativos de lengua inglesa, tiene como objetivo principal investigar los modelos de entonación producidos por ambos grupos de hablantes. Se pretende demostrar que la diferencia a nivel entonativo entre estos dos grupos no sólo tiene como resultado que los no nativos tengan acento extranjero; sino que puede afectar al mensaje transmitido, en cuanto a la estructura y organización de la información dentro del discurso oral en las metafunciones textual e interpersonal.. Se asume la existencia de un sistema entonativo de interlengua, de esta forma este análisis tiene como objeto no sólo reflejar los errores sino también los posibles sistemas aproximativos de los aprendices mencionados..
Resumo:
This paper discusses the development of a computerized version of the CID Early Speech Perception Test.
Resumo:
This paper discusses the creation of a condensed list SRT application of the W-1 for the Macintosh computer.
Resumo:
The goal of the study was to identify what effect headshaking in the horizontal plane has on Computerized Dynamic Posturography results in normals and patients with unilateral vestibular dysfunction. Additionally, the results were compared to results of the dynamic subjective visual vertical test.
Resumo:
This paper discusses the rationale, clinical applications, advantages and disadvantages of three common balance function tests: Electronystagmography (ENG), Rotational Chair Testing (RCT), and Computerized Dynamic Posturography (CDP).