936 resultados para Computer-generated 3D imaging
Resumo:
Conventional coronary magnetic resonance angiography (MRA) techniques display the coronary blood-pool along with the surrounding structures, including the myocardium, the ventricular and atrial blood-pool, and the great vessels. This representation of the coronary lumen is not directly analogous to the information provided by x-ray coronary angiography, in which the coronary lumen displayed by iodinated contrast agent is seen. Analogous "luminographic" data may be obtained using MR arterial spin tagging (projection coronary MRA) techniques. Such an approach was implemented using a 2D selective "pencil" excitation for aortic spin tagging in concert with a 3D interleaved segmented spiral imaging sequence with free-breathing, and real-time navigator technology. This technique allows for selective 3D visualization of the coronary lumen blood-pool, while signal from the surrounding structures is suppressed.
Resumo:
We present a method for segmenting white matter tracts from high angular resolution diffusion MR. images by representing the data in a 5 dimensional space of position and orientation. Whereas crossing fiber tracts cannot be separated in 3D position space, they clearly disentangle in 5D position-orientation space. The segmentation is done using a 5D level set method applied to hyper-surfaces evolving in 5D position-orientation space. In this paper we present a methodology for constructing the position-orientation space. We then show how to implement the standard level set method in such a non-Euclidean high dimensional space. The level set theory is basically defined for N-dimensions but there are several practical implementation details to consider, such as mean curvature. Finally, we will show results from a synthetic model and a few preliminary results on real data of a human brain acquired by high angular resolution diffusion MRI.
Resumo:
En el marc del conveni de col·laboració entre el Grup de Gràfics de Girona de la Universitat de Girona i el Grup de Neuroradiologia de l’Institut de Diagnòstic per la Imatge de l’Hospital Universitari Dr. Josep Trueta de Girona, es planteja desenvolupar la plataforma StarViewer, una plataforma que incorpori les tècniques bàsiques de visualització científica complementant la visualització 2D tradicional amb una visualització 3D que permeti inspeccionar la informació del pacient de forma més eficient i facilitant-ne el seu diagnòstic. En aquest projecte s’implementen dos tècniques que formaran part de la plataforma StarViewer. El primer objectiu és implementar un mètode per facilitar la visualització i la interpretació de models de vòxels simples i models de vòxels fusionats, i el segon és implementar un mètode basat en mesures de la Teoria de la Informació per ajudar l’usuari a trobar el punt de vista òptim per a un model donat. Per assolir el primer objectiu ens centrarem en la tècnica dels Miralls màgics o Magic Mirrors, que permeten la visualització simultània del model de vòxels des de diferents punts de vista, i per al segon objectiu, en el concepte d’excess entropy, que és una mesura de la informació, per determinar quin punt de vista aporta més informació a l’usuari
Resumo:
Three-dimensional information is much easier to understand than a set of two-dimensional images. Therefore a layman is thrilled by the pseudo-3D image taken in a scanning electron microscope (SEM) while, when seeing a transmission electron micrograph, his imagination is challenged. First approaches to gain insight in the third dimension were to make serial microtome sections of a region of interest (ROI) and then building a model of the object. Serial microtome sectioning is a tedious and skill-demanding work and therefore seldom done. In the last two decades with the increase of computer power, sophisticated display options, and the development of new instruments, an SEM with a built-in microtome as well as a focused ion beam scanning electron microscope (FIB-SEM), serial sectioning, and 3D analysis has become far easier and faster.Due to the relief like topology of the microtome trimmed block face of resin-embedded tissue, the ROI can be searched in the secondary electron mode, and at the selected spot, the ROI is prepared with the ion beam for 3D analysis. For FIB-SEM tomography, a thin slice is removed with the ion beam and the newly exposed face is imaged with the electron beam, usually by recording the backscattered electrons. The process, also called "slice and view," is repeated until the desired volume is imaged.As FIB-SEM allows 3D imaging of biological fine structure at high resolution of only small volumes, it is crucial to perform slice and view at carefully selected spots. Finding the region of interest is therefore a prerequisite for meaningful imaging. Thin layer plastification of biofilms offers direct access to the original sample surface and allows the selection of an ROI for site-specific FIB-SEM tomography just by its pronounced topographic features.
Resumo:
The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.
Resumo:
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.
Resumo:
PURPOSE: To compare different techniques for positive contrast imaging of susceptibility markers with MRI for three-dimensional visualization. As several different techniques have been reported, the choice of the suitable method depends on its properties with regard to the amount of positive contrast and the desired background suppression, as well as other imaging constraints needed for a specific application. MATERIALS AND METHODS: Six different positive contrast techniques are investigated for their ability to image at 3 Tesla a single susceptibility marker in vitro. The white marker method (WM), susceptibility gradient mapping (SGM), inversion recovery with on-resonant water suppression (IRON), frequency selective excitation (FSX), fast low flip-angle positive contrast SSFP (FLAPS), and iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) were implemented and investigated. RESULTS: The different methods were compared with respect to the volume of positive contrast, the product of volume and signal intensity, imaging time, and the level of background suppression. Quantitative results are provided, and strengths and weaknesses of the different approaches are discussed. CONCLUSION: The appropriate choice of positive contrast imaging technique depends on the desired level of background suppression, acquisition speed, and robustness against artifacts, for which in vitro comparative data are now available.
Resumo:
PURPOSE: Atherosclerosis results in a considerable medical and socioeconomic impact on society. We sought to evaluate novel magnetic resonance imaging (MRI) angiography and vessel wall sequences to visualize and quantify different morphologic stages of atherosclerosis in a Watanabe hereditary hyperlipidemic (WHHL) rabbit model. MATERIAL AND METHODS: Aortic 3D steady-state free precession angiography and subrenal aortic 3D black-blood fast spin-echo vessel wall imaging pre- and post-Gadolinium (Gd) was performed in 14 WHHL rabbits (3 normal, 6 high-cholesterol diet, and 5 high-cholesterol diet plus endothelial denudation) on a commercial 1.5 T MR system. Angiographic lumen diameter, vessel wall thickness, signal-/contrast-to-noise analysis, total vessel area, lumen area, and vessel wall area were analyzed semiautomatically. RESULTS: Pre-Gd, both lumen and wall dimensions (total vessel area, lumen area, vessel wall area) of group 2 + 3 were significantly increased when compared with those of group 1 (all P < 0.01). Group 3 animals had significantly thicker vessel walls than groups 1 and 2 (P < 0.01), whereas angiographic lumen diameter was comparable among all groups. Post-Gd, only diseased animals of groups 2 + 3 showed a significant (>100%) signal-to-noise ratio and contrast-to-noise increase. CONCLUSIONS: A combination of novel 3D magnetic resonance angiography and high-resolution 3D vessel wall MRI enabled quantitative characterization of various atherosclerotic stages including positive arterial remodeling and Gd uptake in a WHHL rabbit model using a commercially available 1.5 T MRI system.
Resumo:
Images of myocardial strain can be used to diagnose heart disease, plan and monitor treatment, and to learn about cardiac structure and function. Three-dimensional (3D) strain is typically quantified using many magnetic resonance (MR) images obtained in two or three orthogonal planes. Problems with this approach include long scan times, image misregistration, and through-plane motion. This article presents a novel method for calculating cardiac 3D strain using a stack of two or more images acquired in only one orientation. The zHARP pulse sequence encodes in-plane motion using MR tagging and out-of-plane motion using phase encoding, and has been previously shown to be capable of computing 3D displacement within a single image plane. Here, data from two adjacent image planes are combined to yield a 3D strain tensor at each pixel; stacks of zHARP images can be used to derive stacked arrays of 3D strain tensors without imaging multiple orientations and without numerical interpolation. The performance and accuracy of the method is demonstrated in vitro on a phantom and in vivo in four healthy adult human subjects.
Resumo:
The complex structural organization of the white matter of the brain can be depicted in vivo in great detail with advanced diffusion magnetic resonance (MR) imaging schemes. Diffusion MR imaging techniques are increasingly varied, from the simplest and most commonly used technique-the mapping of apparent diffusion coefficient values-to the more complex, such as diffusion tensor imaging, q-ball imaging, diffusion spectrum imaging, and tractography. The type of structural information obtained differs according to the technique used. To fully understand how diffusion MR imaging works, it is helpful to be familiar with the physical principles of water diffusion in the brain and the conceptual basis of each imaging technique. Knowledge of the technique-specific requirements with regard to hardware and acquisition time, as well as the advantages, limitations, and potential interpretation pitfalls of each technique, is especially useful.
Resumo:
BACKGROUND: Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid endarterectomy. METHODS: Patients with symptomatic carotid artery stenosis included in the International Carotid Stenting Study (ICSS) were randomly allocated to receive carotid artery stenting or carotid endarterectomy. Copies of baseline brain imaging were analysed by two investigators, who were masked to treatment, for the severity of white-matter lesions using the age-related white-matter changes (ARWMC) score. Randomisation was done with a computer-generated sequence (1:1). Patients were divided into two groups using the median ARWMC. We analysed the risk of stroke within 30 days of revascularisation using a per-protocol analysis. ICSS is registered with controlled-trials.com, number ISRCTN 25337470. FINDINGS: 1036 patients (536 randomly allocated to carotid artery stenting, 500 to carotid endarterectomy) had baseline imaging available. Median ARWMC score was 7, and patients were dichotomised into those with a score of 7 or more and those with a score of less than 7. In patients treated with carotid artery stenting, those with an ARWMC score of 7 or more had an increased risk of stroke compared with those with a score of less than 7 (HR for any stroke 2·76, 95% CI 1·17-6·51; p=0·021; HR for non-disabling stroke 3·00, 1·10-8·36; p=0·031), but we did not see a similar association in patients treated with carotid endarterectomy (HR for any stroke 1·18, 0·40-3·55; p=0·76; HR for disabling or fatal stroke 1·41, 0·38-5·26; p=0·607). Carotid artery stenting was associated with a higher risk of stroke compared with carotid endarterectomy in patients with an ARWMC score of 7 or more (HR for any stroke 2·98, 1·29-6·93; p=0·011; HR for non-disabling stroke 6·34, 1·45-27·71; p=0·014), but there was no risk difference in patients with an ARWMC score of less than 7. INTERPRETATION: The presence of white-matter lesions on brain imaging should be taken into account when selecting patients for carotid revascularisation. Carotid artery stenting should be avoided in patients with more extensive white-matter lesions, but might be an acceptable alternative to carotid endarterectomy in patients with less extensive lesions. FUNDING: Medical Research Council, the Stroke Association, Sanofi-Synthélabo, the European Union Research Framework Programme 5.
Resumo:
PURPOSE: Visualization of coronary blood flow in the right and left coronary system in volunteers and patients by means of a modified inversion-prepared bright-blood coronary magnetic resonance angiography (cMRA) sequence. MATERIALS AND METHODS: cMRA was performed in 14 healthy volunteers and 19 patients on a 1.5 Tesla MR system using a free-breathing 3D balanced turbo field echo (b-TFE) sequence with radial k-space sampling. For magnetization preparation a slab selective and a 2D selective inversion pulse were used for the right and left coronary system, respectively. cMRA images were evaluated in terms of clinically relevant stenoses (< 50 %) and compared to conventional catheter angiography. Signal was measured in the coronary arteries (coro), the aorta (ao) and in the epicardial fat (fat) to determine SNR and CNR. In addition, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: The use of a selective inversion pre-pulse allowed direct visualization of the coronary blood flow in the right and left coronary system. The measured SNR and CNR, vessel length, and vessel sharpness in volunteers (SNR coro: 28.3 +/- 5.0; SNR ao: 37.6 +/- 8.4; CNR coro-fat: 25.3 +/- 4.5; LAD: 128.0 cm +/- 8.8; RCA: 74.6 cm +/- 12.4; Sharpness: 66.6 % +/- 4.8) were slightly increased compared to those in patients (SNR coro: 24.1 +/- 3.8; SNR ao: 33.8 +/- 11.4; CNR coro-fat: 19.9 +/- 3.3; LAD: 112.5 cm +/- 13.8; RCA: 69.6 cm +/- 16.6; Sharpness: 58.9 % +/- 7.9; n.s.). In the patient study the assessment of 42 coronary segments lead to correct identification of 10 clinically relevant stenoses. CONCLUSION: The modification of a previously published inversion-prepared cMRA sequence allowed direct visualization of the coronary blood flow in the right as well as in the left coronary system. In addition, this sequence proved to be highly sensitive regarding the assessment of clinically relevant stenotic lesions.
Resumo:
BACKGROUND: Three small trials suggest that intravenous immunoglobulin can affect biomarkers and symptoms of mild-to-moderate Alzheimer's disease. We tested the safety, effective dose, and infusion interval of intravenous immunoglobulin in such patients. METHODS: We did a multicentre, placebo-controlled phase 2 trial at seven sites in the USA and five in Germany. Participants with probable Alzheimer's disease aged 50-85 years were randomly assigned (by a computer-generated randomisation sequence, with block sizes of eight) to infusions every 4 weeks (0·2, 0·5, or 0·8 g intravenous immunoglobulin per kg bodyweight, or placebo) or infusions every 2 weeks (0·1, 0·25, or 0·4 g/kg, or placebo). Patients, caregivers, investigators assessing outcomes, and staff at imaging facilities and the clinical research organisation were masked to treatment allocation, but dispensing pharmacists, the statistician, and the person responsible for final PET analyses were not. Treatment was masked with opaque pouches and infusion lines. The primary endpoint was median area under the curve (AUC) of plasma amyloid β (Aβ)(1-40) between the last infusion and the final visit (2 weeks or 4 weeks depending on infusion interval) in the intention-to-treat population. The trial is registered at ClinicalTrials.gov (NCT00812565) and controlled-trials.com (ISRCTN64846759). FINDINGS: 89 patients were assessed for eligibility, of whom 58 were enrolled and 55 included in the primary analysis. Median AUC of plasma Aβ(1-40) was not significantly different for intravenous immunoglobulin compared with placebo for five of the six intervention groups (-18·0 [range -1347·0 to 1068·5] for 0·2 g/kg, -364·3 [-5834·5 to 1953·5] for 0·5 g/kg, and -351·8 [-1084·0 to 936·5] for 0·8 g/kg every 4 weeks vs -116·3 [-1379·0 to 5266·0] for placebo; and -13·8 [-1729·0 to 307·0] for 0·1 g/kg, and -32·5 [-1102·5 to 451·5] for 0·25 g/kg every 2 weeks vs 159·5 [51·5 to 303·0] for placebo; p>0·05 for all). The difference in median AUC of plasma Aβ(1-40) between the 0·4 g/kg every 2 weeks group (47·0 [range -341·0 to 72·5]) and the placebo group was significant (p=0·0216). 25 of 42 (60%) patients in the intervention group versus nine of 14 (64%) receiving placebo had an adverse event. Four of 42 (10%) patients in the intravenous immunoglobulin group versus four of 14 (29%) receiving placebo had a serious adverse event, including one stroke in the intervention group. INTERPRETATION: Intravenous immunoglobulin may have an acceptable safety profile. Our results did not accord with those from previous studies. Longer trials with greater power are needed to assess the cognitive and functional effects of intravenous immunoglobulin in patients with Alzheimer's disease.
Resumo:
Lasertekniikkaa hyödyntävä 3D-kuvaustekniikka tuo uusia mahdollisuuksia robotilla suoritettavaan kasastapoimintaan. Kasasta otetun syvyyskuvan avulla tuotteista voidaan määrittää perinteisen XY-paikkatiedon lisäksi tuotteen korkeus- ja asentotieto. Näitä uusia ominaisuuksia hyödyntämällä robotilla voidaan suorittaa yksittäisen tuotteen poiminta kasasta eri korkeuksilta ja eri asennoista. Diplomityö kuuluu osana Master Automation Groupin ensimmäiseen 3D-tekniikkaan perustuvaan MAG PixCell 3D -robosoituun kappaleenkäsittelysoluun. Työn tavoitteena on kehittääsyvyyskuvan käsittelyyn algoritmeja, joiden avulla robotilla voidaan poimia yksitellen kasassa olevia metallisia saksen teriä. Algoritmien tarkoituksena on varmistaa kasasta löydettyjen terien poimittavuus sekä määrittää poimittavien terien korkeudet ja asennot. Tarkastusten jälkeen robotille välitetään terien XYZ-koordinaatti- ja asentotiedot.
Resumo:
Human-like computer interaction systems requires far more than just simple speech input/output. Such a system should communicate with the user verbally, using a conversational style language. It should be aware of its surroundings and use this context for any decisions it makes. As a synthetic character, it should have a computer generated human-like appearance. This, in turn, should be used to convey emotions, expressions and gestures. Finally, and perhaps most important of all, the system should interact with the user in real time, in a fluent and believable manner.