868 resultados para Computer vision methods for sign language recognition


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper explores the application of semi-qualitative probabilistic networks (SQPNs) that combine numeric and qualitative information to computer vision problems. Our version of SQPN allows qualitative influences and imprecise probability measures using intervals. We describe an Imprecise Dirichlet model for parameter learning and an iterative algorithm for evaluating posterior probabilities, maximum a posteriori and most probable explanations. Experiments on facial expression recognition and image segmentation problems are performed using real data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tese de dout., Engenharia Electrónica e de Computadores, Faculdade de Ciência e Tecnologia, Universidade do Algarve, 2007

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sign language animations can lead to better accessibility of information and services for people who are deaf and have low literacy skills in spoken/written languages. Due to the distinct word-order, syntax, and lexicon of the sign language from the spoken/written language, many deaf people find it difficult to comprehend the text on a computer screen or captions on a television. Animated characters performing sign language in a comprehensible way could make this information accessible. Facial expressions and other non-manual components play an important role in the naturalness and understandability of these animations. Their coordination to the manual signs is crucial for the interpretation of the signed message. Software to advance the support of facial expressions in generation of sign language animation could make this technology more acceptable for deaf people. In this survey, we discuss the challenges in facial expression synthesis and we compare and critique the state of the art projects on generating facial expressions in sign language animations. Beginning with an overview of facial expressions linguistics, sign language animation technologies, and some background on animating facial expressions, a discussion of the search strategy and criteria used to select the five projects that are the primary focus of this survey follows. This survey continues on to introduce the work from the five projects under consideration. Their contributions are compared in terms of support for specific sign language, categories of facial expressions investigated, focus range in the animation generation, use of annotated corpora, input data or hypothesis for their approach, and other factors. Strengths and drawbacks of individual projects are identified in the perspectives above. This survey concludes with our current research focus in this area and future prospects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To define and evaluate a Computer-Vision (CV) method for scoring Paced Finger-Tapping (PFT) in Parkinson's disease (PD) using quantitative motion analysis of index-fingers and to compare the obtained scores to the UPDRS (Unified Parkinson's Disease Rating Scale) finger-taps (FT). Background: The naked-eye evaluation of PFT in clinical practice results in coarse resolution to determine PD status. Besides, sensor mechanisms for PFT evaluation may cause patients discomfort. In order to avoid cost and effort of applying wearable sensors, a CV system for non-invasive PFT evaluation is introduced. Methods: A database of 221 PFT videos from 6 PD patients was processed. The subjects were instructed to position their hands above their shoulders besides the face and tap the index-finger against the thumb consistently with speed. They were facing towards a pivoted camera during recording. The videos were rated by two clinicians between symptom levels 0-to-3 using UPDRS-FT. The CV method incorporates a motion analyzer and a face detector. The method detects the face of testee in each video-frame. The frame is split into two images from face-rectangle center. Two regions of interest are located in each image to detect index-finger motion of left and right hands respectively. The tracking of opening and closing phases of dominant hand index-finger produces a tapping time-series. This time-series is normalized by the face height. The normalization calibrates the amplitude in tapping signal which is affected by the varying distance between camera and subject (farther the camera, lesser the amplitude). A total of 15 features were classified using K-nearest neighbor (KNN) classifier to characterize the symptoms levels in UPDRS-FT. The target ratings provided by the raters were averaged. Results: A 10-fold cross validation in KNN classified 221 videos between 3 symptom levels with 75% accuracy. An area under the receiver operating characteristic curves of 82.6% supports feasibility of the obtained features to replicate clinical assessments. Conclusions: The system is able to track index-finger motion to estimate tapping symptoms in PD. It has certain advantages compared to other technologies (e.g. magnetic sensors, accelerometers etc.) for PFT evaluation to improve and automate the ratings

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The TV is a potential midia of communication that affects all social classes and it is available in 98% of Brazilian homes. It has been used as a distributor of educational materials since the 1950s. By 2016 the Open Digital TV (ODTV) in Brazil might cover the entire national territory, replacing the TV with analog signals. Concerns about accessibility for People with Special Needs (PSN) in that media have become more intense since the 1990s worldwide. In Brazil, it is estimated 24.6 million of PSN, 23% of them having some type of hearing loss. Of these, 2.9% are reported as deafs. Brazilian Sign Language (LIBRAS) is considered the first literacy language for deaf people in Brazil. In this context, this paper presents a proposal to facilitate the generation of educational content for ODTV based on two components. One is called SynchrLIBRAS and allows subtitles synchronization in Portuguese and a LIBRAS translator window of videos downloaded from the Web. The second component allows the visualization of this content through the Brazilian System of Digital TV and IPTV - environments that implement the middleware Ginga-NCL. The main focus of this paper is the presentation of the first component: SynchrLIBRAS. This proposal has educational purposes, contributing to teach LIBRAS to people who may collaborate with social inclusion of the deaf people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[ES]This paper describes some simple but useful computer vision techniques for human-robot interaction. First, an omnidirectional camera setting is described that can detect people in the surroundings of the robot, giving their angular positions and a rough estimate of the distance. The device can be easily built with inexpensive components. Second, we comment on a color-based face detection technique that can alleviate skin-color false positives. Third, a simple head nod and shake detector is described, suitable for detecting affirmative/negative, approval/dissaproval, understanding/disbelief head gestures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La tesi tratta i temi di computer vision connessi alle problematiche di inserimento in una piattaforma Web. Nel testo sono spiegate alcune soluzioni per includere una libreria software per l'emotion recognition in un'applicazione web e tecnologie per la registrazione di un video, catturando le immagine da una webcam.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Sensor-based recordings of human movements are becoming increasingly important for the assessment of motor symptoms in neurological disorders beyond rehabilitative purposes. ASSESS MS is a movement recording and analysis system being developed to automate the classification of motor dysfunction in patients with multiple sclerosis (MS) using depth-sensing computer vision. It aims to provide a more consistent and finer-grained measurement of motor dysfunction than currently possible. Objective: To test the usability and acceptability of ASSESS MS with health professionals and patients with MS. Methods: A prospective, mixed-methods study was carried out at 3 centers. After a 1-hour training session, a convenience sample of 12 health professionals (6 neurologists and 6 nurses) used ASSESS MS to capture recordings of standardized movements performed by 51 volunteer patients. Metrics for effectiveness, efficiency, and acceptability were defined and used to analyze data captured by ASSESS MS, video recordings of each examination, feedback questionnaires, and follow-up interviews. Results: All health professionals were able to complete recordings using ASSESS MS, achieving high levels of standardization on 3 of 4 metrics (movement performance, lateral positioning, and clear camera view but not distance positioning). Results were unaffected by patients’ level of physical or cognitive disability. ASSESS MS was perceived as easy to use by both patients and health professionals with high scores on the Likert-scale questions and positive interview commentary. ASSESS MS was highly acceptable to patients on all dimensions considered, including attitudes to future use, interaction (with health professionals), and overall perceptions of ASSESS MS. Health professionals also accepted ASSESS MS, but with greater ambivalence arising from the need to alter patient interaction styles. There was little variation in results across participating centers, and no differences between neurologists and nurses. Conclusions: In typical clinical settings, ASSESS MS is usable and acceptable to both patients and health professionals, generating data of a quality suitable for clinical analysis. An iterative design process appears to have been successful in accounting for factors that permit ASSESS MS to be used by a range of health professionals in new settings with minimal training. The study shows the potential of shifting ubiquitous sensing technologies from research into the clinic through a design approach that gives appropriate attention to the clinic environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a preprocessing module for improving the performance of a Spanish into Spanish Sign Language (Lengua de Signos Espanola: LSE) translation system when dealing with sparse training data. This preprocessing module replaces Spanish words with associated tags. The list with Spanish words (vocabulary) and associated tags used by this module is computed automatically considering those signs that show the highest probability of being the translation of every Spanish word. This automatic tag extraction has been compared to a manual strategy achieving almost the same improvement. In this analysis, several alternatives for dealing with non-relevant words have been studied. Non-relevant words are Spanish words not assigned to any sign. The preprocessing module has been incorporated into two well-known statistical translation architectures: a phrase-based system and a Statistical Finite State Transducer (SFST). This system has been developed for a specific application domain: the renewal of Identity Documents and Driver's License. In order to evaluate the system a parallel corpus made up of 4080 Spanish sentences and their LSE translation has been used. The evaluation results revealed a significant performance improvement when including this preprocessing module. In the phrase-based system, the proposed module has given rise to an increase in BLEU (Bilingual Evaluation Understudy) from 73.8% to 81.0% and an increase in the human evaluation score from 0.64 to 0.83. In the case of SFST, BLEU increased from 70.6% to 78.4% and the human evaluation score from 0.65 to 0.82.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a methodology for adapting an advanced communication system for deaf people in a new domain. This methodology is a user-centered design approach consisting of four main steps: requirement analysis, parallel corpus generation, technology adaptation to the new domain, and finally, system evaluation. In this paper, the new considered domain has been the dialogues in a hotel reception. With this methodology, it was possible to develop the system in a few months, obtaining very good performance: good speech recognition and translation rates (around 90%) with small processing times.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

College personnel are required to provide accommodations for students who are deaf and hard of hearing (D/HoH), but few empirical studies have been conducted on D/HoH students as they learn under the various accommodation conditions (sign language interpreting, SLI, real-time captioning, RTC, and both). Guided by the experiences of students who are D/HoH at Miami-Dade College (MDC) who requested RTC in addition to SLI as accommodations, the researcher adopted Merten’s transformative-emancipatory theoretical framework that values perceptions and voice of students who are D/HoH. A mixed methods design addressed two research questions: Did student learning differ for each accommodation? What did students experience while learning through accommodations? Participants included 30 students who were D/HoH (60% women). They represented MDC’s majority minority population: 10% White (non-Hispanic), 20% Black (non-Hispanic, including Haitian/Caribbean), 67% Hispanic, and 3% other. Hearing loss, ranged from severe-profound (70%) to mild-moderate (30%). All were able to communicate with American Sign Language: Learning was measured while students who were D/HoH viewed three lectures under three accommodation conditions (SLI, RTC, SLI+RTC). The learning measure was defined as the difference in pre- and post-test scores on tests of the content presented in the lectures. Using repeated measure ANOVA and ANCOVA, confounding variables of fluency in American Sign Language and literacy skills were treated as covariates. Perceptions were obtained through interviews and verbal protocol analysis that were signed, videotaped, transcribed, coded, and examined for common themes and metacognitive strategies. No statistically significant differences were found among the three accommodations on the learning measure. Students who were D/HoH expressed thoughts about five different aspects of their learning while they viewed lectures: (a) comprehending the information, (b) feeling a part of the classroom environment, (c) past experiences with an accommodation, (d) individual preferences for an accommodation, (e) suggestions for improving an accommodation. They exhibited three metacognitive strategies: (a) constructing knowledge, (b) monitoring comprehension, and (c) evaluating information. No patterns were found in the types of metacognitive strategies used for any particular accommodation. The researcher offers recommendations for flexible applications of the standard accommodations used with students who are D/HoH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work explores the use of statistical methods in describing and estimating camera poses, as well as the information feedback loop between camera pose and object detection. Surging development in robotics and computer vision has pushed the need for algorithms that infer, understand, and utilize information about the position and orientation of the sensor platforms when observing and/or interacting with their environment.

The first contribution of this thesis is the development of a set of statistical tools for representing and estimating the uncertainty in object poses. A distribution for representing the joint uncertainty over multiple object positions and orientations is described, called the mirrored normal-Bingham distribution. This distribution generalizes both the normal distribution in Euclidean space, and the Bingham distribution on the unit hypersphere. It is shown to inherit many of the convenient properties of these special cases: it is the maximum-entropy distribution with fixed second moment, and there is a generalized Laplace approximation whose result is the mirrored normal-Bingham distribution. This distribution and approximation method are demonstrated by deriving the analytical approximation to the wrapped-normal distribution. Further, it is shown how these tools can be used to represent the uncertainty in the result of a bundle adjustment problem.

Another application of these methods is illustrated as part of a novel camera pose estimation algorithm based on object detections. The autocalibration task is formulated as a bundle adjustment problem using prior distributions over the 3D points to enforce the objects' structure and their relationship with the scene geometry. This framework is very flexible and enables the use of off-the-shelf computational tools to solve specialized autocalibration problems. Its performance is evaluated using a pedestrian detector to provide head and foot location observations, and it proves much faster and potentially more accurate than existing methods.

Finally, the information feedback loop between object detection and camera pose estimation is closed by utilizing camera pose information to improve object detection in scenarios with significant perspective warping. Methods are presented that allow the inverse perspective mapping traditionally applied to images to be applied instead to features computed from those images. For the special case of HOG-like features, which are used by many modern object detection systems, these methods are shown to provide substantial performance benefits over unadapted detectors while achieving real-time frame rates, orders of magnitude faster than comparable image warping methods.

The statistical tools and algorithms presented here are especially promising for mobile cameras, providing the ability to autocalibrate and adapt to the camera pose in real time. In addition, these methods have wide-ranging potential applications in diverse areas of computer vision, robotics, and imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Much of the bridge stock on major transport links in North America and Europe was constructed in the 1950s and 1960s and has since deteriorated or is carrying loads far in excess of the original design loads. Structural Health Monitoring Systems (SHM) can provide valuable information on the bridge capacity but the application of such systems is currently limited by access and bridge type. This paper investigates the use of computer vision systems for SHM. A series of field tests have been carried out to test the accuracy of displacement measurements using contactless methods. A video image of each test was processed using a modified version of the optical flow tracking method to track displacement. These results have been validated with an established measurement method using linear variable differential transformers (LVDTs). The results obtained from the algorithm provided an accurate comparison with the validation measurements. The calculated displacements agree within 2% of the verified LVDT measurements, a number of post processing methods were then applied to attempt to reduce this error.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Much of the bridge stock on major transport links in North America and Europe was constructed in the 1950’s and 1960’s and has since deteriorated or is carrying loads far in excess of the original design loads. Structural Health Monitoring Systems (SHM) can provide valuable information on the bridge capacity but the application of such systems is currently limited by access and system cost. This paper investigates the development of a low cost portable SHM system using commercially available cameras and computer vision techniques. A series of laboratory tests have been carried out to test the accuracy of displacement measurements using contactless methods. The results from each of the tests have been validated with established measurement methods, such as linear variable differential transformers (LVDTs). A video image of each test was processed using two different digital image correlation programs. The results obtained from the digital image correlation methods provided an accurate comparison with the validation measurements. The calculated displacements agree within 4% of the verified measurements LVDT measurements in most cases confirming the suitability full camera based SHM systems