991 resultados para Cisalhamento - Resistência


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to evaluate in vitro the shear bond strenght to bovine dentin, during 24h and 30 days with the following variables: resin cements Enforce and Panavia F; aesthetics restorative materials Art Glass, IPS Empress 2 and Targis, with surface treatment with microetching with aluminium oxide, fluoridric acid and silane. Two hundred eighty eight sound bovine teeth from 3 years old animals constituted the samples after inclusion on polyester resin box. lnstron model 430 Universal Testing Machine, a crosshead speed 0,5 mm/min and load cells of 500 Kg, was used for shear bond strenght testing (MPa). The results were statistically analysed by ANOVA The best result was obtained with /PS Empress 2, microetched with aluminium oxide, fluoridric acid and silane, cemented with Panavia F and stored in distilled water, 3f'C during 30 days

Relevância:

40.00% 40.00%

Publicador:

Resumo:

O sucesso das restaurações metálicas indiretas depende, dentre outros fatores, de uma união eficaz entre a estrutura metálica e o cimento dentário empregados. Sabe-se que os primers para metal atuam com comprovada eficácia na resistência adesiva dos cimentos resinosos às ligas nobres. Entretanto, pouco foi estudado sobre o efeito de tais materiais em ligas não nobres. O propósito deste estudo foi avaliar a eficácia de primers para metal na resistência ao cisalhamento da união entre cimentos resinosos e metais não nobres. Discos (9 mm de diâmetro e 3 mm de altura) foram fundidos em liga de NiCr (n=80) e em titânio comercialmente puro (Ti c.p.) (n=80) e foram incluídos em anel de PVC com resina acrílica quimicamente ativada. As superfícies dos discos foram regularizadas com lixas de carbeto de silício de granulação 320, 400 e 600 e jateadas com partículas de óxido de alumínio de 50 µm. Espécimes de cada metal foram divididos em quatro grupos (n=20). Uma matriz metálica bi-partida (5 mm de diâmetro interno e 2 mm de altura) foi posicionada na superfície do espécime. As áreas adesivas receberam um dos seguintes tratamentos: 1) Panavia F; 2) Alloy Primer e Panavia F; 3) Bistite DC e 4) Metaltite e Bistite DC. Para evitar a exposição dos cimentos à luz, estes foram espatulados e inseridos na matriz dentro de uma câmara de revelação radiográfica. Quarenta minutos após a confecção, os espécimes foram armazenados em água destilada a 37ºC por 24 horas e então termociclados (1.000 ciclos, 5ºC e 55ºC, 30 segundos cada banho). Após a termociclagem, os espécimes foram armazenados novamente nas mesmas condições descritas anteriormente por um período de 24 horas (n=10) ou de 6 meses (n=10) antes do ensaio de cisalhamento em uma máquina de ensaios mecânicos (Material Test System 810).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is little information regarding bond strengths of polyglass to metal alloys. This study evaluated the influence of bonding system on shear bond strength of a composite resin (Artglass/Heraeus Kulzer) to cast titanium (Ti). Twenty metallic structures (4mm in diameter, 5mm thick) of titanium grade I were cast shaped and abraded with 250mm aluminum oxide and separated into two groups. For each group was applied one bonding system (Siloc or Retention Flow) before opaque and dentin polymer superposition. This procedure was managed using teflon matrices. They were manipulated and polymerized according to the manufacturer's recommendations. The samples were stored in distilled water for 24 hours at 37º and thermocycled (5º and 55ºC/500 cycles). Shear bond strength tests were performed by using an Instron Universal testing machine at a crosshead speed of 5mm/min. Results were analyzed statistically with one-way ANOVA (a=0,5) and they indicated that the Retention Flow system was statistically better than Siloc (20.74 MPa and 11.65 MPa , respectively). It was possible to conclude that the bonding agent influenced the adhesion between polymer and cast titanium.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The disadvantages generated by the acid etching of the dentin, such as an increase in its permeability, in the surface moisture and in the potential to denature the external dentinal collagen, the formation of a fragility zone and the citotoxicity of the adhesive monomers; which are all aggravated by the depth of the dentin, have stimulated new and different treatment philosophies of the dentin. The purpose of the present study, therefore, was to investigate the effects of three dentin treatments: laser irradiation, acid etching and hypermineralization, in the shear bond strength of the SMP Plus bonding system. Sixty bovine incisors were extracted and randomly selected immediatly alter the animal's death. They were kept frozen (-18°C) for no longer than 14 days. After buccal dentinal surface had been exposed, X-Rays were taken to control the dentin thickness. The specimens were separated into two groups: (1) Control, kept in distilled water at 4ºC; (2) Mineralized, kept in hypermineralized solution at 4°C for 14 days. Each group was divided into three sub-groups according to the type of dentin treatment used: group F - followed the manufacturer instructions (acid-etching + primer + bond), group AL (acid-etching + primer + bond + laser) and group LA (laser + (laser + acid-etching + primer + bond). A composite resin standard cylinder (Z100-3M) was bond to the dentinal surface and the shear bond strength performed on a Universal lnstron machine 4301, with 500 Kg load and at 0,5mm/min. speed. The analysis of variance (ANOVA) determined that the treatments influenced the shear bond strength values (p<0,05) with the following average shearing load at failure: AL (9,96 MPa), F (7,28MPa) e LA (4,87 MPa). The interaction between the two factors analyzed Group (control and mineralized) and treatment (F, AL, LA) also influenced the shear bond strength (p<0,05). The highest values were obtained...

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nos estudos referentes à estabilidade de maciços rochosos, é de capital importância a identificação dos planos de fraqueza do maciço rochoso. Estes planos de fraques condicionam a estabilidade do maciço, tanto mais quanto mais adversa a posição dos mesmos com relação ás tensões cisalhantes atuantes. De modo geral, os planos de fraqueza consistem de camadas e intercalações de rocha fraca ou alterada, ou de fraturas e outras descontinuidades as quais são frequentemente preenchidas por solo. Quando uma intercalação de solo, argilito, folhelho, etc, apresenta-se em intercalação a camadas de rochas duras, (ou mesmo de preenchimentos alterados de fraturas e falhas) tem sido prática comum adotar a resistência ao cisalhamento do material de preenchimento como sendo o valor mais baixo da resistência da descontinuidade. Entretanto, conforme foi sugerido por Patton (1968), existe a hipótese de que a prática acima não seja válida, e que a resistência ao cisalhamento do contacto seja inferior à obtida para o solo de preenchimento propriamente dito. O objetivo desta investigação é o de iniciar o estudo da resistência ao cisalhamento de contactos solo-rocha, e de compara essa resistência às do solo e da rocha obtidas separadamente

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The soil resistance to penetration and shear can be used as indicators of soil compaction and to indicate the susceptibility of a soil to erosion. The objective of this study was to quantify and compare the impact provided by different land uses in a haplic cambissol in areas of permanent preservation, from the soil resistance to penetration and shear. The experimental area was located in an area of permanent preservation, the sub-basin of the Ribeira Iguape River - SP, with different land uses: banana cultivation - CBAN, degraded pasture - PDEG, silvopastoral system - MPIS and native forest - MNAT. The test for resistance to penetration was accomplished with a digital penetrometer compaction of manual effort, to a depth of 40 cm. The soil shear strength was determined by Vane Test at a depth between 0 and 5 cm. The degraded pasture was similar to native forest, with less resistance to penetration. The banana cultivation and silvopastoral system were the land uses with the highest resistance to penetration, bringing serious risk of erosion in areas of permanent preservation. The soil under native forest had lower shear strength. The cultivation of bananas, degraded pasture and silvopastoral system were the land uses with higher shear strength of soil, indicating that the use of these soils in areas of permanent preservation is promoting the same compression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recentemente a utilização de estruturas mistas, aço concreto, vem ganhando espaço nas construções. Isso deve-se principalmente a economia de tempo em sua execução. Além disto, nesta solução a utilização do aço e do concreto otimiza as características estruturais de seus elementos: a resistência a tração do aço e a compressão do concreto. A transferência dos esforços entre os dois materiais possui grande influência no desempenho de uma estrutura mista, sendo comum a utilização de conectores de cisalhamento na região da interface entre estes dois materiais. O Eurocode 4 define um ensaio experimental denominado push-out de modo a determinar a resistência e ductilidade de conectores de cisalhamento. Seu desempenho é influenciado pelas resistências do concreto a compressão, as dimensões e taxa de armadura da laje de concreto, dimensões do perfil de aço, a disposição e a geometria dos conectores e pelas características dos aços utilizados no conector, no perfil e nas barras de reforço. Nota-se com isso uma grande quantidade de variáveis que influenciam o ensaio. Assim, o presente trabalho apresenta o desenvolvimento de um modelo em elementos finitos com base no programa ANSYS para simulação de ensaios push-out. Os resultados numéricos apresentados neste trabalho foram calibrados com resultados obtidos em ensaios experimentais existentes na literatura de ensaios push-out para conectores do tipo pino com cabeça (stud) e conectores tipo perfobond. Estes últimos apresentam elevada resistência sendo influenciados por inúmeros fatores como: número e diâmetro dos furos no conector e a inclusão ou não de barras de reforço extras nestes furos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente estudo visa avaliar a influência da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro em diferentes regiões do conduto radicular (cervical, médio e apical), cimentados com cimento resinoso autoadesivo, com e sem a adição de Rodamina B, por meio do teste de push-out. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Após sete dias, os condutos foram desobstruídos e aleatoriamente divididos em 4 grupos (n=10), de acordo com as brocas do sistema de pinos de fibra WhitePost DC (FGM) usadas: (G1) broca #2; (G2) broca #3; (G3) broca #4; (G4) broca #2. O preparo foi realizado a uma profundidade de 10 mm. A cimentação foi realizada com o cimento resinoso autoadesivo RelyX U100 (3M ESPE), e apenas nos grupos G1, G2 e G3 uma pequena quantidade de Rodamina B em pó foi usada como corante no cimento. Após uma semana, cada raiz foi seccionada em máquina de corte, obtendo-se 6 fatias de 1 0,1 mm de espessura. Antes do ensaio de push-out, imagens digitais foram obtidas, por meio de um estereomicroscópio, de ambas as faces de cada fatia, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram obtidas para determinação do modo de falha. Para determinar a espessura de cimento, foi desenvolvida uma rotina (macro) no software KS 400. Os dados foram estatisticamente analisados com análise de variância (ANOVA) 2 fatores (influência do diâmetro da broca e influência dos terços) e Kruskal-Wallis (influência da espessura do filme de cimento). Comparações múltiplas foram realizadas com o teste Duncan. Todos os testes foram aplicados com α=0,05. Houve diferenças significantes entre os grupos em relação ao diâmetro da broca (p<0,0001), sendo G2 (14,62 5,15 MPa) > G1 (10,04 5,13 MPa) > G3 (7,68 6,14 MPa). O terço do conduto exerceu influência significativa sobre a resistência adesiva (p<0,0001), sendo os maiores valores obtidos no terço apical. As espessuras do filme de cimento foram estatisticamente diferentes nos grupos. Os maiores valores de espessura de cimento foram obtidos no G3 (248,78 μm), seguido de G2 (185,91 μm) e G1 (110,16 μm), sendo o último estatisticamente semelhante ao G4 (119,99 μm). Os resultados de G1(10,04 5,13 MPa) e G4 (8,89 + 5,18 MPa) foram estatisticamente semelhantes, indicando que a presença da Rodamina B não influencia significativamente na resistência de união. O tipo de falha predominante no G1 foi mista, no G2, adesiva entre pino e cimento, e no G3 e G4, adesiva entre cimento e dentina. O diâmetro da broca influenciou significativamente nos resultados de resistência de união ao teste de push-out. O ligeiro aumento na espessura do filme de cimento promoveu um aumento nos valores de resistência, quando comparado com filmes de cimento muito finos ou muito espessos.