994 resultados para Calibration measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Q values and 0o cross sections of (He3, n) reactions forming seven proton-rich nuclei have been measured with accuracies varying from 6 to 18 keV. The Q values (in keV) are: Si26 (85), S30 (-573), Ar34 (-759), Ti42 (-2865), Cr48 (5550), Ni56 (4513) and Zn60 (818). At least one excited state was found for all but Ti42. The first four nuclei complete isotopic spin triplets; the results obtained agree well with charge-symmetry predictions. The last three, all multiples of the α particle, are important in the α and e-process theories of nucleo-synthesis in stars. The energy available for β decay of these three was found by magnetic spectrometer measurements of the (He3, p) Q values of reactions leading to V48, Co56, and Cu60. Many excited states were seen: V48 (3), Co56 (15), Cu60 (23). The first two states of S30 are probably 0+ and 2+ from (He3, n) angular distribution measurements. Two NaI γ-ray measurements are described: the decay of Ar34 (measured Ƭ1/2 = 1.2 ± 0.3s) and the prompt γ-ray spectrum from Fe54(He3, nγ)Ni56. Possible collective structure in Ni56 and Ca40, both doubly magic, is discussed.

The (He3, n) neutron energy and yield measurements utilized neutron-induced nuclear reactions in a silicon semiconductor detector. Cross sections for the most important detection processes, Si28 (n, α) Mg25 and Si28 (n, p) Al28, are presented for reactions leading to the first four states of both residual nuclei for neutron energies from 7.3 to 16.4 MeV. Resolution and pulse-height anomalies associated with recoil Mg25 and Al28 ions are discussed. The 0o cross section for Be9 (α, n) C12, used to provide calibration neutrons, has been measured with a stilbene spectrometer for no (5.0 ≤ Eα ≤ 12 MeV), n1 (4.3 ≤ Eα ≤ 12.0 MeV) and n2 (6.0 ≤ Eα ≤ 10.1 MeV). Resonances seen in the no yield may correspond to nine new levels in C13.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An air filled ionization chamber has been constructed with a volume of 552 liters and a wall consisting of 12.7 mg/cm2 of plastic wrapped over a rigid, lightweight aluminum frame. A calibration in absolute units, independent of previous Caltech ion chamber calibrations, was applied to a sealed Neher electrometer for use in this chamber. The new chamber was flown along with an older, argon filled, balloon type chamber in a C-135 aircraft from 1,000 to 40,000 feet altitude, and other measurements of sea level cosmic ray ionization were made, resulting in the value of 2.60 ± .03 ion pairs/cm3 sec atm) at sea level. The calibrations of the two instruments were found to agree within 1 percent, and the airplane data were consistent with previous balloon measurements in the upper atmosphere. Ionization due to radon gas in the atmosphere was investigated. Absolute ionization data in the lower atmosphere have been compared with results of other observers, and discrepancies have been discussed.

Data from a polar orbiting ion chamber on the OGO-II, IV spacecraft have been analyzed. The problem of radioactivity produced on the spacecraft during passes through high fluxes of trapped protons has been investigated, and some corrections determined. Quiet time ionization averages over the polar regions have been plotted as function of altitude, and an analytical fit is made to the data that gives a value of 10.4 ± 2.3 percent for the fractional part of the ionization at the top of the atmosphere due to splash albedo particles, although this result is shown to depend on an assumed angular distribution for the albedo particles. Comparisons with other albedo measurements are made. The data are shown to be consistent with balloon and interplanetary ionization measurements. The position of the cosmic ray knee is found to exhibit an altitude dependence, a North-South effect, and a small local time variation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New technologies can be riddled with unforeseen sources of error, jeopardizing the validity and application of their advancement. Bioelectrical impedance analysis (BIA) is a new technology in fisheries research that is capable of estimating proximate composition, condition, and energy content in fish quickly, cheaply, and (after calibration) without the need to sacrifice fish. Before BIA can be widely accepted in fisheries science, it is necessary to identify sources of error and determine a means to minimize potential errors with this analysis. We conducted controlled laboratory experiments to identify sources of errors within BIA measurements. We concluded that electrode needle location, procedure deviations, user experience, time after death, and temperature can affect resistance and reactance measurements. Sensitivity analyses showed that errors in predictive estimates of composition can be large (>50%) when these errors are experienced. Adherence to a strict protocol can help avoid these sources of error and provide BIA estimates that are both accurate and precise in a field or laboratory setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The band-by-band vicarious calibration of on-orbit satellite ocean color instruments, such as SeaWiFS and MODIS, using ground-based measurements has significant residual uncertainties. This paper applies spectral shape and population statistics to tune the calibration of the blue bands against each other to allow examination of the interband calibration and potentially provide an analysis of calibration trends. This adjustment does not require simultaneous matches of ground and satellite observations. The method demonstrates the spectral stability of the SeaWiFS calibration and identifies a drift in the MODIS instrument onboard Aqua that falls within its current calibration uncertainties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Failure of retaining walls is observed after many recent seismic events. Design of these walls are based on the pseudo-static force designs based on the Mononobe-Okabe earth pressure coefficient equations. However, it is clear that there are limitations attached with this approach. This paper investigates the seismic behaviour of sheet pile retaining walls using dynamic centrifuge testing facilities. In addition to using bending moment strain gauges on the wall, new generation earth pressure cells have also been used to investigate the generation of active and passive earth pressures. The results indicate that Mononobe-Okabe equations give relatively good estimates of active earth pressures but may be over-predicting passive earth pressures at certain peak ground acceleration levels. Based on this series of centrifuge tests it is concluded that earth pressure cells are successful in providing good qualitative data, but need to be supplemented by good calibration methods. © 2010 Taylor & Francis Group, London.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An accurate and simple technique for measuring the input reflection coefficient and the frequency response of semiconductor laser diode chips is proposed and demonstrated. All the packaging parasitics could be obtained accurately using a calibrated probe, and the impedance of the intrinsic diode chip is deduced from the directly measured reflection coefficient. The directly measured impedance of a laser diode is affected strongly by the short bond wire. In the frequency response (S(2)1) measurements of semiconductor laser diode chips, the test fixture consists of a microwave probe, a submount, and a bond wire. The S-parameters of the probe could be determined using the short-open-match (SOM) method. Both the attenuation and the reflection of the test fixture have a strong influence on the directly measured frequency response, and in our proposed technique, the effect of test fixture is completely removed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper begins from the thru-short-open (TSO) and thru-line-match (TLM) methods to investigate the correlation of the calibration equations of these two methods, The relations among the measurements with the corresponding standards are obtained. It is found that the line standard with zero length can be used instead of ideal open and short, in case that two test fixtures are symmetrical. For asymmetrical fixtures, the measurements with the standards line, open and short are related at certain frequencies, and the matched load can be replaced by the line standards. The relations established are used to test short and match standards and analyze the freqPuency limits of the TSO method, Good agreement between theory and experiment is obtained, It is found that the TSO method becomes very poor when the insertion phase of the thru standard is near n pi/4, and this method has a lower frequency limit. The TLM method is found unsuitable for calibrating asymmetrical fixtures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new ocean wave and sea surface current monitoring system with horizontally-(HH) and vertically-(VV) polarized X-band radar was developed. Two experiments into the use of the radar system were carried out at two sites, respectively, for calibration process in Zhangzi Island of the Yellow Sea, and for validation in the Yellow Sea and South China Sea. Ocean wave parameters and sea surface current velocities were retrieved from the dual polarized radar image sequences based on an inverse method. The results obtained from dual-polarized radar data sets acquired in Zhangzi Island are compared with those from an ocean directional buoy. The results show that ocean wave parameters and sea surface current velocities retrieved from radar image sets are in a good agreement with those observed by the buoy. In particular, it has been found that the vertically-polarized radar is better than the horizontally-polarized radar in retrieving ocean wave parameters, especially in detecting the significant wave height below 1.0 m.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative optical spectroscopy has the potential to provide an effective low cost, and portable solution for cervical pre-cancer screening in resource-limited communities. However, clinical studies to validate the use of this technology in resource-limited settings require low power consumption and good quality control that is minimally influenced by the operator or variable environmental conditions in the field. The goal of this study was to evaluate the effects of two sources of potential error: calibration and pressure on the extraction of absorption and scattering properties of normal cervical tissues in a resource-limited setting in Leogane, Haiti. Our results show that self-calibrated measurements improved scattering measurements through real-time correction of system drift, in addition to minimizing the time required for post-calibration. Variations in pressure (tested without the potential confounding effects of calibration error) caused local changes in vasculature and scatterer density that significantly impacted the tissue absorption and scattering properties Future spectroscopic systems intended for clinical use, particularly where operator training is not viable and environmental conditions unpredictable, should incorporate a real-time self-calibration channel and collect diffuse reflectance spectra at a consistent pressure to maximize data integrity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Very short-lived halocarbons are significant sources of reactive halogen in the marine boundary layer, and likely in the upper troposphere and lower stratosphere. Quantifying ambient concentrations in the surface ocean and atmosphere is essential for understanding the atmospheric impact of these trace gas fluxes. Despite the body of literature increasing substantially over recent years, calibration issues complicate the comparison of results and limit the utility of building larger-scale databases that would enable further development of the science (e.g. sea-air flux quantification, model validation, etc.). With this in mind, thirty-one scientists from both atmospheric and oceanic halocarbon communities in eight nations gathered in London in February 2008 to discuss the scientific issues and plan an international effort toward developing common calibration scales (http://tinyurl.com/c9cg58). Here, we discuss the outputs from this meeting, suggest the compounds that should be targeted initially, identify opportunities for beginning calibration and comparison efforts, and make recommendations for ways to improve the comparability of previous and future measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study presents a methods evaluation and intercalibration of active fluorescence-based measurements of the quantum yield ( inline image) and absorption coefficient ( inline image) of photosystem II (PSII) photochemistry. Measurements of inline image, inline image, and irradiance (E) can be scaled to derive photosynthetic electron transport rates ( inline image), the process that fuels phytoplankton carbon fixation and growth. Bio-optical estimates of inline image and inline image were evaluated using 10 phytoplankton cultures across different pigment groups with varying bio-optical absorption characteristics on six different fast-repetition rate fluorometers that span two different manufacturers and four different models. Culture measurements of inline image and the effective absorption cross section of PSII photochemistry ( inline image, a constituent of inline image) showed a high degree of correspondence across instruments, although some instrument-specific biases are identified. A range of approaches have been used in the literature to estimate inline image and are evaluated here. With the exception of ex situ inline image estimates from paired inline image and PSII reaction center concentration ( inline image) measurements, the accuracy and precision of in situ inline image methodologies are largely determined by the variance of method-specific coefficients. The accuracy and precision of these coefficients are evaluated, compared to literature data, and discussed within a framework of autonomous inline image measurements. This study supports the application of an instrument-specific calibration coefficient ( inline image) that scales minimum fluorescence in the dark ( inline image) to inline image as both the most accurate in situ measurement of inline image, and the methodology best suited for highly resolved autonomous inline image measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The University of Waikato, Hamilton, New Zealand and The Queen's University of Belfast, Northern Ireland radiocarbon dating laboratories have undertaken a series of high-precision measurements on decadal samples of dendrochronologically dated oak (Quercus petraea) from Great Britain and cedar (Libocedrus bidwillii) and silver pine (Lagarostrobos colensoi) from New Zealand. The results show an average hemispheric offset over the 900 yr of measurement of 40±13 yr. This value is not constant but varies with a periodicity of about 130 yr. The Northern Hemisphere measurements confirm the validity of the Pearson et al. (1986) calibration dataset.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have conducted a series of radiocarbon measurements on decadal samples of dendrochronologically dated wood from both hemispheres, spanning 1000 years (McCormac et al. 1998; Hogg et al. this issue). Using the data presented in Hogg et al., we show that during the period AD 950-1850 the 14C offset between the hemispheres is not constant, but varies periodically (~130 yr periodicity) with amplitudes varying between 1 and 10‰ (i.e. 8-80 yr), with a consequent effect on the 14C calibration of material from the Southern Hemisphere. A large increase in the offset occurs between AD 1245 and 1355. In this paper, we present a Southern Hemisphere high-precision calibration data set (SHCal02) that comprises measurements from New Zealand, Chile, and South Africa. This data, and a new value of 41 ± 14 yr for correction of the IntCal98 data for the period outside the range given here, is proposed for use in calibrating Southern Hemisphere 14C dates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radiocarbon dating has been rarely used for chronological problems relating to the Anglo-Saxon period. The "flatness" of the calibration curve and the resultant wide range in calendrical dates provide little advantage over traditional archaeological dating in this period. Recent advances in Bayesian methodology have, however, created the possibility of refining and checking the established chronologies, based on typology of artifacts, against 14C dates. The calibration process, within such a confined age range, however, relies heavily on the structural accuracy of the calibration curve. We have therefore re-measured, at decadal intervals, a section of the Irish oak chronology for the period AD 495–725. These measurements have been included in IntCal04.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent measurements on dendrochronologically-dated wood from the Southern Hemisphere have shown that there are differences between the structural form of the radiocarbon calibration curves from each hemisphere. Thus, it is desirable, when possible, to use calibration data obtained from secure dendrochronologically-dated wood from the corresponding hemisphere. In this paper, we outline the recent work and point the reader to the internationally recommended data set that should be used for future calibration of Southern Hemisphere 14C dates.