217 resultados para CRT
Resumo:
The benefits of cardiac resynchronization therapy (CRT) in the health-related quality of life (HRQL) are largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions that constitute HRQL are still a matter of discussion. Objective: To evaluate the impact of CRT on the HRQL of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT. Methods: 43 patients, submitted to successful implantation of CRT, were evaluated in hospital just before intervention and in the outpatient clinic within 6 months after CRT. HRQL was analyzed based on the Kansas City Cardiomyopathy Questionnaire (KCCQ). Patients were classified as super-responders (ejection fraction of left ventricle - LVEF - ≥45% post-CRT), n=15, responders (sustained improvement in functional class and LVEF increased by 15%), n=19, and non-responders (no clinical or LVEF improvement), n=9. Results: In the group of super-responders, CRT was associated with an improvement in HRQL for the various fields and sums assessed (ρ<0.05); in responders, CRT has been associated with an improvement of HRQL in the various fields and sums, except in the self-efficacy dimension (ρ<0.05); in non-responders, CRT was not associated with improvement of HRQL. Conclusion: In a population with severe CHF undergoing CRT, the patients with clinical and echocardiographic positive response, obtained a favorable impact in all dimensions of HRQL, while the group without response to CRT showed no improvement. These data reinforces the importance of HRQL as a multidimensional tool for assessment of benefits in clinical practice.
Resumo:
The benefits of cardiac resynchronization therapy (CRT) in the quality of life have been largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions of quality of life is still a matter of discussion. Objective: to evaluate the impact of CRT on the quality of life of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
OBJETIVO: Em decorrência dos questionamentos sobre o efeito deletério das radiações emitidas pelo campo eletromagnético (CEM) dos tipos ELF (extremely low frequency) e VLF (very low frequency) transmitidas pelos monitores de vídeo dos computadores (CRT), foi avaliada a freqüência de anomalias cromossômicas estruturais e a cinética do ciclo celular em indivíduos expostos por seu trabalho à radiação dos CRT. MÉTODOS: A pesquisa de aberrações cromossômicas foi realizada em 2.000 metáfases de primeira divisão celular obtidas de culturas de 48h de linfócitos de sangue venoso periférico de dez indivíduos expostos ao CRT (grupo E) e de dez controles (grupo C). A cinética do ciclo celular foi pesquisada pelos índices mitótico (IM) e de proliferação celular (IPC). RESULTADOS: A análise estatística evidenciou freqüências significativamente maiores de metáfases com anomalias cromossômicas (E=5,9%; C=3,7%) e anomalias/célula (E=0,066±0,026; C=0,040±0,026) nos indivíduos expostos aos CRTs. As alterações citogenéticas mais comuns foram as quebras cromatídicas, com freqüência de 0,034±0,016 no grupo E e de 0,016±0,015 no grupo C. As freqüências de IM e IPC não apresentaram diferenças significantes entre os grupos avaliados. CONCLUSÕES: Os resultados sugerem um efeito genotóxico do CEM emitido pelos CRTs devido à freqüência mais elevada de quebras cromatídicas, enfatizando a necessidade de haver um número maior de estudos com diferentes técnicas que vise a investigar a ação do CEM sobre o material genético.
Resumo:
OBJETIVO: Categorizar e descrever as fontes de estresse cotidianas de mulheres portadoras do vírus da imunodeficiência humana (HIV). MÉTODOS: Foram realizadas entrevistas individuais, por meio de um questionário semi-estruturado, com uma amostra consecutiva de 150 mulheres portadoras do HIV, de julho a dezembro de 1997, no Centro de Referência e Tratamento de Doenças Sexualmente Transmissíveis e Aids (CRT DST/Aids) (Secretaria de Estado da Saúde, SP). As variáveis investigadas foram: dados demográficos, estrutura familiar, percepção de risco, sexualidade, acesso ao sistema de saúde, adesão ao tratamento, uso de álcool e drogas, evento significativo e evento estressante, sendo este o foco de discussão do artigo. RESULTADOS: Apenas 14% dos eventos estressantes são diretamente resultados do tratamento ou do adoecimento. Os relatos das fontes de estresse foram distribuídos nos seguintes assuntos: familiares (17%); relacionamento com o parceiro (12%); filhos (14%); enfermidade (14%); relacionamento com outras pessoas (9%); problemas financeiros (8%) e profissionais (7%); vivências de discriminação (7%); outros (4%); e não responderam (8%). CONCLUSÕES: As fontes de estresse apresentam principalmente um conteúdo afetivo-relacional, derivadas muitas vezes do estigma associado ao HIV e, na maioria das vezes, a temas comuns a todas as mulheres. Os profissionais de saúde deveriam oferecer cuidado integral às mulheres portadoras do HIV.
Resumo:
Introdução: Este trabalho tem como principal objectivo comparar os efeitos secundários agudos da Radioterapia por Intensidade Modulada (IMRT) e a Radioterapia Tridimensional Conformada (3 D-CRT) no carcinoma de Próstata; Materiais e métodos: Foram observados os processos clínicos de 30 doentes e analisados os efeitos colaterais da RT ocorridos no decurso do tratamento. Resultados: A percentagem de toxicidade aguda dermatológica foi superior no grupo tratado com 3D-CRT. Nenhum doente apresentou toxicidade aguda grave. Conclusões: O tamanho reduzido da amostra e a ausência de valores estatisticamente significativos, não permite concluir a influência da técnica de RT no desenvolvimento de efeitos secundários agudos.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações
Resumo:
Mestrado Integrado em Engenharia Biomédica
Resumo:
This work presents a novel surface Smart Polymer Antibody Material (SPAM) for Carnitine (CRT, a potential biomarker of ovarian cancer), tested for the first time as ionophore in potentiometric electrodes of unconventional configuration. The SPAM material consisted of a 3D polymeric network created by surface imprinting on graphene layers. The polymer was obtained by radical polymerization of (vinylbenzyl) trimethylammonium chloride and 4-styrenesulfonic acid (signaling the binding sites), and vinyl pivalate and ethylene glycol dimethacrylate (surroundings). Non-imprinted material (NIM) was prepared as control, by excluding the template from the procedure. These materials were then used to produce several plasticized PVC membranes, testing the relevance of including the SPAM as ionophore, and the need for a charged lipophilic additive. The membranes were casted over solid conductive supports of graphite or ITO/FTO. The effect of pH upon the potentiometric response was evaluated for different pHs (2-9) with different buffer compositions. Overall, the best performance was achieved for membranes with SPAM ionophore, having a cationic lipophilic additive and tested in HEPES (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) buffer, pH 5.1. Better slopes were achieved when the membrane was casted on conductive glass (-57.4 mV/decade), while the best detection limits were obtained for graphite-based conductive supports (3.6 × 10−5mol/L). Good selectivity was observed against BSA, ascorbic acid, glucose, creatinine and urea, tested for concentrations up to their normal physiologic levels in urine. The application of the devices to the analysis of spiked samples showed recoveries ranging from 91% (± 6.8%) to 118% (± 11.2%). Overall, the combination of the SPAM sensory material with a suitable selective membrane composition and electrode design has lead to a promising tool for point-of-care applications.
Resumo:
Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.
Resumo:
1st ASPIC International Congress
Resumo:
III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013
Resumo:
Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013
Resumo:
INTRODUCTION: The significant risk of sudden arrhythmic death in patients with congestive heart failure and electromechanical ventricular dyssynchrony has led to increased use of combined cardiac resynchronization therapy defibrillator (CRT-D) devices. OBJECTIVES: To evaluate the echocardiographic variables in patients undergoing CRT-D that predict the occurrence of appropriate therapies (AT) for ventricular tachyarrhythmia. METHODS: We analyzed 38 consecutive patients (mean age 60 +/- 12 years, 63% male) with echocardiographic evaluation before and 6 months after CRT-D implantation. Patients with AT were identified in a mean follow-up of 471 +/- 323 days. A standard echocardiographic study was performed including tissue Doppler imaging (TDI). Responders were defined as patients with improvement in NYHA class of < or = 1 in the first six months, and reverse remodeling as a decrease in left ventricular end-systolic volume of < or = 15% and/or an increase in left ventricular ejection fraction of > 25%. RESULTS: The responder rate was 74%, and the reverse remodeling rate was 55%. AT occurred in 21% of patients, who presented with greater left ventricular end-diastolic internal diameter (LVEDD) before implantation (86 +/- 8 vs. 76 +/- 11 mm, p = 0.03) and at 6 months (81 +/- 8 vs. 72 +/- 14 mm, p = 0.08), and increased left ventricular end-systolic internal diameter (66 +/- 14 vs. 56 +/- 14 mm, p = 0.03) and lower ejection fraction (24 +/- 6 vs. 34 +/- 14%, p = 0.08) at 6 months. In the group with AT, the responder rate was lower (38 vs. 83%, p = 0.03), without significant differences in reverse remodeling (38% for the AT group vs. 60%, p = 0.426) or in the other variables. By univariate analysis, predictors of AT were LVEDD before implantation and E' after implantation. Age, gender, ischemic etiology, use of antiarrhythmic drugs, reverse remodeling and the other echocardiographic parameters did not predict AT. In multivariate logistic regression analysis, both LVEDD before implantation (OR 1.24, 95% CI 1.04-1.48, p = 0.019) and postimplantation E' (OR 0.27, 95% CI 0.09-0.76, p = 0.014) remained as independent predictors of AT. CONCLUSIONS: In patients undergoing CRT-D, episodes of ventricular tachyarrhythmia occur with high incidence, independently of echocardiographic response, with LVEDD before implantation and E' after implantation as the only independent predictors of AT in the medium-term. These results highlight the importance of combined devices with defibrillation capability.