918 resultados para CPU load
Resumo:
Background. Many resource-limited countries rely on clinical and immunological monitoring without routine virological monitoring for human immunodeficiency virus (HIV)-infected children receiving highly active antiretroviral therapy (HAART). We assessed whether HIV load had independent predictive value in the presence of immunological and clinical data for the occurrence of new World Health Organization (WHO) stage 3 or 4 events (hereafter, WHO events) among HIV-infected children receiving HAART in Latin America. Methods. The NISDI (Eunice Kennedy Shriver National Institute of Child Health and Human Development International Site Development Initiative) Pediatric Protocol is an observational cohort study designed to describe HIV-related outcomes among infected children. Eligibility criteria for this analysis included perinatal infection, age ! 15 years, and continuous HAART for >= 6 months. Cox proportional hazards modeling was used to assess time to new WHO events as a function of immunological status, viral load, hemoglobin level, and potential confounding variables; laboratory tests repeated during the study were treated as time-varying predictors. Results. The mean duration of follow-up was 2.5 years; new WHO events occurred in 92 (15.8%) of 584 children. In proportional hazards modeling, most recent viral load 15000 copies/mL was associated with a nearly doubled risk of developing a WHO event (adjusted hazard ratio, 1.81; 95% confidence interval, 1.05-3.11; P = 033), even after adjustment for immunological status defined on the basis of CD4 T lymphocyte value, hemoglobin level, age, and body mass index. Conclusions. Routine virological monitoring using the WHO virological failure threshold of 5000 copies/mL adds independent predictive value to immunological and clinical assessments for identification of children receiving HAART who are at risk for significant HIV-related illness. To provide optimal care, periodic virological monitoring should be considered for all settings that provide HAART to children.
Resumo:
Serum hepatitis B virus (HBV) DNA [eve[ is a predictor of the development of cirrhosis and hepatocellullar carcinoma in chronic hepatitis B patients. Nevertheless, the distribution of viral load levels in chronic HBV patients in Brazil has yet to be described. This cross-sectional study included 564 participants selected in nine Brazilian cities located in four of the five regions of the country using the database of a medical diagnostics company. Admission criteria included hepatitis B surface antigen seropositivity, availability of HBV viral toad samples and age >= 18 years. Mates comprised 64.5% of the study population. Mean age was 43.7 years. Most individuals (62.1%) were seronegative for the hepatitis B e antigen (HBeAg). Median serum ALT level was 34 U/L. In 58.5% of the patients HBV-DNA levels ranged from 300 to 99,999 copies/mL; however, in 21.6% levels were undetectable. Median HBV-DNA level was 2,351 copies/mL. Over 60% of the patients who tested negative for HBeAg and in whom ALT level was less than 1.5 times the upper limit of the normal range had HBV-DNA levels > 2,000 IU/mL, which has been considered a cut-off point for indicating a liver biopsy and/or treatment. In conclusion, HBV-DNA level identified a significant proportion of Brazilian individuals with chronic hepatitis B at risk of disease progression. Furthermore, this tool. enables those individuals with high HBV-DNA levels who are susceptible to disease progression to be identified among patients with normal or stightly elevated ALT.
Resumo:
Although human T-cell lymphotropic virus type 2 (HTLV-2) is considered of low pathogenicity, serological diagnosis is important for counseling and monitoring. The confirmatory tests most used are Western blot (WB) and PCR. However, in high-risk populations, about 50% of the indeterminate WB were HTLV-2 positives by PCR. The insensitivity of the WB might be due to the use of recombinant proteins of strains that do not circulate in our country. Another possibility may be a high level of immunosuppression, which could lead to low production of virus, resulting in low stimulation of antibody. We found one mutation, proline to serine in the envelope region in the position 184, presented at least 1/3 of the samples, independent the indeterminate WB profile. In conclusion, we found no correlation of immune state, HTLV-2 proviral load, or env diversity in the K55 region and WB indeterminate results. We believe that the only WB kit available in the market is probably more accurate to detect HTLV-1 antibodies, and some improvement for HTLV-2 detection should be done in the future, especially among high-risk population. J. Med. Virol. 82:837-842,2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
Background: Many clinical studies have suggested a beneficial effect of GB virus type C (GBV-C) on the course of HIV-1 infection, but the mechanisms involved in such amelioration are not clear. As recent evidence has implicated cellular activation in HIV-1 pathogenesis, we investigated the effect of GBV-C viremia on T-cell activation in early HIV-1 infection. Methods: Forty-eight recently infected HIV-1 patients (23 GBV-C viremic) were evaluated for T-cell counts, expanded immunophenotyping GBV-C RNA detection, and HIV-1 viral load. Nonparametric univariate and multivariate analyses were carried out to identify variables associated with cellular activation, including GBV-C status, HIV-1 viral load, T lymphocyte counts, and CD38 and chemokine (C-C motif) receptor 5 (CCR5) surface expression. Finding: We not only confirmed the positive correlation between HIV-1 viral load and the percentage of T cells positive for CD38(+)CD8(+) but also observed that GBV-C viremic patients had a lower percentage of T cells positive for CD38(+)CD4(+), CD38(+)CD8(+), CCR5(+)CD4(+), and CCR5(+)CD8(+) compared with HIV-1-infected patients who were not GBV-C viremic. In regression models, GBV-C RNA(+) status was associated with a reduction in the CD38 on CD4(+) or CD8(+) T cells and CCR5(+) on CD8(+) T cells, independent of the HIV-1 viral load or CD4(+) and CD8(+) T-cell counts. These results were also supported by the lower expression of CD69 and CD25 in GBV-C viremic patients. Interpretation: The association between GBV-C replication and lower T-cell activation may be a key mechanism involved in the protection conferred by this virus against HIV-1 disease progression to immunodeficiency in HIV-1-infected patients. (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins
Resumo:
To examine abnormal patterns of frontal cortical-subcortical activity in response to emotional stimuli in euthymic individuals with bipolar disorder type I in order to identify trait-like, pathophysiologic mechanisms of the disorder. We examined potential confounding effects of total psychotropic medication load and illness variables upon neural abnormalities. We analyzed neural activity in 19 euthymic bipolar and 24 healthy individuals to mild and intense happy, fearful and neutral faces. Relative to healthy individuals, bipolar subjects had significantly increased left striatal activity in response to mild happy faces (p < 0.05, corrected), decreased right dorsolateral prefrontal cortical (DLPFC) activity in response to neutral, mild and intense happy faces, and decreased left DLPFC activity in response to neutral, mild and intense fearful faces (p < 0.05, corrected). Bipolar and healthy individuals did not differ in amygdala activity in response to either emotion. In bipolar individuals, there was no significant association between medication load and abnormal activity in these regions, but a negative relationship between age of illness onset and amygdala activity in response to mild fearful faces (p = 0.007). Relative to those without comorbidities, bipolar individuals with comorbidities showed a trend increase in left striatal activity in response to mild happy faces. Abnormally increased striatal activity in response to potentially rewarding stimuli and decreased DLPFC activity in response to other emotionally salient stimuli may underlie mood instabilities in euthymic bipolar individuals, and are more apparent in those with comorbid diagnoses. No relationship between medication load and abnormal neural activity in bipolar individuals suggests that our findings may reflect pathophysiologic mechanisms of the illness rather than medication confounds. Future studies should examine whether this pattern of abnormal neural activity could distinguish bipolar from unipolar depression.
Resumo:
Background: HTLV-2 infections are almost always asymptomatic, and diseases associated with the infection are rarely reported. Little information is available on the relationship between HTLV-2 proviral load and gender or expression of disease, especially among patients with HlV-1 co-infection. Methods: We studied 77 HTLV-2-infected subjects followed in our clinic for the last 9 years; 53 (69%) of them were co-infected with HIV-1. HTLV-2 DNA proviral load (PVL) was measured by real time PCR, a test with a sensitivity of 10 in 10(4) PBMCs. Results: Six of 53 HTLV-2/HIV-1 cases had a myelopathy (all of them had undetectable PVL of HTLV-2). Only 3 of 35 women (2 out of 3 co-infected with HIV) had a detectable PVL, whereas 10 of 42 men had a detectable PVL. Regardless of their HIV status women had significantly lower PVL than men (10 vs. 43 CopieS/10(4) PBMCs, p < 0.05). Conclusions: We noticed the occurrence of myelopathy in HTLV-2/HIV-1 co-infected patients, with undetectable HTLV-2 viral load. There was a sex difference in viral load for HTLV-2, what may be the result in mode of transmission or acquisition of the virus. (c) 2008 Elsevier B. V. All rights reserved.
Resumo:
The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This study evaluated the influence of adhesive layer thickness (ADL) on the resin-dentin bond strength of two adhesive systems (AS) after ther-mal and mechanical loading (TML). A flat superficial dentin surface was exposed with 600-grit SiC paper on 40 molars. After primer application, the adhesive layer of Scotchbond Multipurpose (SBMP) or Clearfil SE Bond (CSEB) was applied in one or two layers to a delimited area (52 mm(2)) and resin blocks (Filtek 2250) were built incrementally: Half of the sample was stored in distilled water (37 C, 24 hours) and submitted to thermal (1,000; 5 degrees-55 degrees C) and mechanical cycles (500,000; 10kgf) [TML]. The other half was stored in distilled water (72 hours). The teeth were then sectioned to obtain sticks (0.8 mm(2)) to be tested under tensile mode (1.0 mm/minute). The fracture mode was analyzed at 400x. The BS from all sticks from the same tooth was averaged for statistical purposes. The data was analyzed by three-way ANOVA. The x(2) test was used (p<0.05) to compare the frequency of pre-testing failure specimens. Higher BS values were observed for SBMP regardless of the ADL. The TML reduced the BS values irrespective of the adhesive employed and the ADL. A higher frequency of pre-testing failure specimens was observed for the cycled groups. A thicker adhesive layer, acting as an intermediate flexible layer, did not min-imize the damage caused by thermal/mechanical load cycling for a three-step etch-and-rinse and two-step self-etch system.
Resumo:
In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.
Resumo:
Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load Introduction: Millions of people around the world do not have access to the benefits of osseointegration. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in the oral medicine field. This is an alternative therapy for retention and stability achievement in total prosthesis with conventional treatment, and two implants are enough to establish a satisfactory overdenture. Objective: The objectives of the study were to evaluate 16 patients of both sexes, with an average age of 47.4 +/- 4 years, using electromyographic analysis of masseter and temporal muscles and analyse the increase of incisive and molar maximal bite force with their existing complete dentures and following mandibular implant overdenture therapy to assess the benefits of this treatment. Materials and methods: For these tests, the Myosystem-BR1 electromyograph and the IDDK Kratos dynamometer were used. Statistical analysis was performed using the repeated measures test (SPSS 17.0). Results: A decrease in electromyographic activity during the rest, lateral and protrusion movements and increase of the maximal incisive and molar bite force after 15 months with a mandibular implant overdenture was observed. Conclusion: All the patients in this study reported a considerable improvement in the masticatory function and prostheses stability following treatment. It is possible to propose that the use of mandibular implants overdenture should become the selected treatment for totally edentulous patients to facilitate oral function and quality of life.
Resumo:
This paper proposed a novel model for short term load forecast in the competitive electricity market. The prior electricity demand data are treated as time series. The forecast model is based on wavelet multi-resolution decomposition by autocorrelation shell representation and neural networks (multilayer perceptrons, or MLPs) modeling of wavelet coefficients. To minimize the influence of noisy low level coefficients, we applied the practical Bayesian method Automatic Relevance Determination (ARD) model to choose the size of MLPs, which are then trained to provide forecasts. The individual wavelet domain forecasts are recombined to form the accurate overall forecast. The proposed method is tested using Queensland electricity demand data from the Australian National Electricity Market. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Primary infection with the human herpesvirus, Epstein-Barr virus (EBV), may result in subclinical seroconversion or may appear as infectious mononucleosis (IM), a lymphoproliferative disease of variable severity. Why primary infection manifests differently between patients is unknown, and, given the difficulties in identifying donors undergoing silent seroconversion, little information has been reported. However, a longstanding assumption has been held that IM represents an exaggerated form of the virologic and immunologic events of asymptomatic infection. T-cell receptor (TCR) repertoires of a unique cohort of subclinically infected patients undergoing silent infection were studied, and the results highlight a fundamental difference between the 2 forms of infection. In contrast to the massive T-cell expansions mobilized during the acute symptomatic phase of IM, asymptomatic donors largely maintain homeostatic T-cell control and peripheral blood repertoire diversity. This disparity cannot simply be linked to severity or spread of the infection because high levels of EBV DNA were found in the blood from both types of acute infection. The results suggest that large expansions of T cells within the blood during IM may not always be associated with the control of primary EBV infection and that they may represent an overreaction that exacerbates disease. (C) 2001 by The American Society of Hematology.
Resumo:
This paper discusses the design and characterisation of a short, and hence portable impact load cell for in-situ quantification of ore breakage properties under impact loading conditions. Much literature has been published in the past two decades about impact load cells for ore breakage testing. It has been conclusively shown that such machines yield significant quantitative energy-fragmentation information about industrial ores. However, documented load cells are all laboratory systems that are not adapted for in-situ testing due to their dimensions and operating requirements. The authors report on a new portable impact load cell designed specifically for in-situ testing. The load cell is 1.5 m in height and weighs 30 kg. Its physical and operating characteristics are detailed in the paper. This includes physical dimensions, calibration and signal deconvolution. Emphasis is placed on the deconvolution issue, which is significant for such a short load cell. Finally, it is conclusively shown that the short load cell is quantitatively as accurate as its larger laboratory analogues. (C) 2062 Elsevier Science B.V. All rights reserved.