983 resultados para CHAIN-REACTION ASSAY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Members of the Culex sitiens subgroup are important vectors of arboviruses, including Japanese encephalitis virus, Murray Valley encephalitis virus and Ross River virus. Of the eight described species, Cx. annulirostris Skuse, Cx. sitiens Wiedemann, and Cx. palpalis Taylor appear to be the most abundant and widespread throughout northern Australia and Papua New Guinea (PNG). Recent investigations using allozymes have shown this subgroup to contain cryptic species that possess overlapping adult morphology. We report the development of a polymerase chain reaction-restriction fragment-length polymorphism (PCR-RFLP) procedure that reliably separates these three species. This procedure utilizes the sequence variation in the ribosomal DNA ITS1 and demonstrates species-specific PCR-RFLP profiles from both colony and field collected material. Assessment of the consistency of this procedure was undertaken on mosquitoes sampled from a wide geographic area including Australia, PNG, and the Solomon Islands. Overlapping adult morphology was observed for Cx. annulirostris and Cx. palpalis in both northern Queensland and PNG and for all three species at one site in northwest Queensland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A polymerase chain reaction was carried out to detect pathogenic leptospires isolated from animals and humans in Argentina. A double set of primers (G1/G2, B64-I/B64-II), described before, were used to amplify by PCR a DNA fragment from serogroups belonging to Leptospira interrogans but did not allow to detect saprophytic strains isolated from soil and water (L. biflexa). This fact represents an advantage since it makes possible the differentiation of pathogenic from non-pathogenic leptospires in cultures. The sensitivity of this assay has been determined, allowing to detect just only 10 leptospires in the reaction tube. Those sets of primers generated either a 285 bp or 360 bp fragment, depending on the pathogenic strain

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a polymerase chain reaction (PCR) protocol for the detection of Salmonella in artificially contaminated chicken meat. Tests were performed with different dilutions of Salmonella Typhimurium or Salmonella Enteritidis cells (10-7, 10-8 or 10-9 CFU/mL) inoculated in chicken meat samples, in order to establish the limits of detection, incubation times (0, 6, 8 and 24 hours of pre-enrichment in PBW 1%) and three DNA extraction protocols (phenol-chloroform, thermal treatment and thermal treatment and Sephaglass). The assay was able to detect until 10-9 CFU/mL of initial dilution of Salmonella cells inoculated in chicken meat, which allows detection of Salmonella within 48 hours, including 24 hours of pre-enrichment and using the phenol-chloroform DNA extraction protocol. As the results are obtained in a shorter time period than that of microbiological culture, this procedure will be useful in the methodology for detection of Salmonella in chicken.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A ligase chain reaction DNA amplification method for direct detection of Mycobacterium tuberculosis (Abbott LCx MTB) in respiratory specimens was evaluated. Results from LCx MTB Assay were compared with those from acid fast bacilli smear, culture, and final clinical diagnosis for each patient. A total of 297 respiratory specimens (sputum and bronchial lavage) from 193 patients were tested. The sensitivity, specificity, positive predictive value and negative predictive value of LCx vs culture were 92.7%, 93%, 67.8% and 98.7%, respectively. When compared to the clinical final diagnosis, the sensitivity, specificity, PPV and NPV for LCx were 88.9%, 96.8%, 86.5% and 97.4%, respectively. The sensitivity of LCx MTB assay was 75% for smear-negative, culture positive samples. The results indicate that LCx MTB assay is a rapid, simple and valuable technique as a complementary tool for the diagnosis of tuberculosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Exanthem subitum is a classical rash disease of early childhood caused by human herpesvirus 6B (HHV-6B). However, the rash is frequently misdiagnosed as that of either measles or rubella. METHODS: In this study, a nested multiplex polymerase chain reaction (PCR) was used to diagnose HHV-6B primary infection, differentiate it from infections caused by HHV-6A and compare it to antibody avidity tests. The samples were separated into case group and control group according to the results of the indirect immunofluorescence assay (IFA) technique. RESULTS: From the saliva samples analyzed, HHV-6A DNA was detected in 3.2% of the case group and in 2.6% of the control group. Regarding HHV-6B, PCR detected viral DNA in 4.8% of the case group and in 1.3% of the control group. Among the serum samples studied, a frequency of 1.7% was determined for HHV-6A in the case group and 1.2% in the control group. PCR did not detect HHV-6B DNA in serum samples. The sensitivity and specificity of the PCR technique ranged from 0% to 4.8% and 97.5% to 100%, respectively, compared to IFA. CONCLUSIONS: The PCR technique was not suitable for diagnosing primary infection by HHV-6B in children with exanthematic disease and should not substitute the IFA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Dogs play a primary role in the zoonotic cycle of visceral leishmaniasis (VL). Therefore, the accurate diagnosis of infected dogs, primarily asymptomatic dogs, is crucial to the efficiency of VL control programs. Methods We investigated the agreement of four diagnostic tests for canine visceral leishmaniasis (CVL): parasite detection, either after myeloculture or by direct microscopic examination of tissue imprints; kinetoplast-deoxyribonucleic acid-polymerase chain reaction (kDNA-PCR); and an immunochromatographic test (ICT). An enzyme-linked immunosorbent assay (ELISA) and an indirect immunofluorescence test (IFAT), both of which were adopted as part of the screening-culling program in Brazil, were used as reference tests. Our sample set consisted of 44 seropositive dogs, 25 of which were clinically asymptomatic and 19 were symptomatic for CVL according to ELISA-IFAT. Results The highest and lowest test co-positivities were observed for ICT (77.3%) and myeloculture (58.1%), respectively. When analyzed together, the overall percentage of co-positive tests was significantly higher for the symptomatic group compared to the asymptomatic group. However, only ICT was significantly different based on the results of a separate analysis per test for each group of dogs. The majority (93.8%) of animals exhibited at least one positive test result, with an average of 2.66 positive tests per dog. Half of the symptomatic dogs tested positive for all four tests administered. Conclusions The variability between test results reinforces the need for more efficient and reliable methods to accurately diagnose canine VL, particularly in asymptomatic animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We show here a simplified reverse transcription-polymerase chain reaction (RT-PCR) for identification of dengue type 2 virus. Three dengue type 2 virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD, as a negative control, were used in this study. C6/36 cells were infected with the virus, and tissue culture fluids were collected after 7 days of infection period. The RT-PCR, a combination of RT and PCR done after a single addition of reagents in a single reaction vessel was carried out following a digestion of virus with 1% Nonidet P-40. The 50ml assay reaction mixture included 50 pmol of a dengue type 2 specific primer pair amplifying a 210 base pair sequence of the envelope protein gene, 0.1 mM of the four deoxynucleoside triphosphates, 7.5U of reverse transcriptase, and 1U of thermostable Taq DNA polymerase. The reagent mixture was incubated for 15 min at 37oC for RT followed by a variable amount of cycles of two-step PCR amplification (92oC for 60 sec, 53oC for 60 sec) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized with UV light after gel incubation in ethidium bromide solution. DNA bands were observed after 25 and 30 cycles of PCR. Virus amount as low as 102.8 TCID50/ml was detected by RT-PCR. Specific DNA amplification was observed with the three dengue type 2 strains. This assay has advantages compared to other RT-PCRs: it avoids laborious extraction of virus RNA; the combination of RT and PCR reduces assay time, facilitates the performance and reduces risk of contamination; the two-step PCR cycle produces a clear DNA amplification, saves assay time and simplifies the technique

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An hemodialysis population in Central Brazil was screened by polymerase chain reaction (PCR) and serological methods to assess the prevalence of hepatitis C virus (HCV) infection and to investigate associated risk factors. All hemodialysis patients (n=428) were interviewed in eight dialysis units in Goiânia city. Blood samples were collected and serum samples screened for anti-HCV antibodies by an enzyme-linked immunosorbent assay (ELISA). Positive samples were retested for confirmation with a line immunoassay (LIA). All samples were also tested for HCV RNA by the PCR. An overall prevalence of 46.7% (CI 95%: 42-51.5) was found, ranging from 20.7% (CI 95%: 8.8-38.1) to 90.4% (CI 95%: 79.9-96.4) depending on the dialysis unit. Of the 428 patients, 185 were found to be seropositive by ELISA, and 167 were confirmed positive by LIA, resulting in an anti-HCV prevalence of 39%. A total of 131 patients were HCV RNA-positive. HCV viremia was present in 63.5% of the anti-HCV-positive patients and in 10.3% of the anti-HCV-negative patients. Univariate analysis of risk factors showed that the number of previous blood transfusions, transfusion of blood before mandatory screening for anti-HCV, length of time on hemodialysis, and treatment in multiple units were associated with HCV positivity. However, multivariate analysis revealed that blood transfusion before screening for anti-HCV and length of time on hemodialysis were significantly associated with HCV infection in this population. These data suggest that nosocomial transmission may play a role in the spread of HCV in the dialysis units studied. In addition to anti-HCV screening, HCV RNA detection is necessary for the diagnosis of HCV infection in hemodialysis patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thirty eight patients with indeterminate leprosy (HI), at least 4 to 6 years after discharge from multibacillary (MB) or paucibacillary (PB) schemes of anti leprosy multidrug therapy (MDT), were submitted to traditional diagnostic procedures for leprosy and to polymerase chain reaction (PCR) analysis of different clinical samples for detection of Mycobacterium leprae DNA. No significant difference was observed for any of the parameters analyzed between PB or MB schemes of treatment and no indications were found for more efficient outcome of HI using the MB scheme. Remarkably, 18 (54.5%) of the individuals were PCR positive in at least one of the samples: positivity of PCR was highest in blood samples and four individuals were PCR positive in blood and some other sample. Upon comparison of PCR results with clinical and histopathological parameters, no correlation was found between PCR-positivity and eventual relapse. This is the first report on detection of M. leprae DNA in PB patients, more than half a decade after completion of MDT, suggesting that live bacilli are present and circulating much longer than expected, although reinfection of the individuals can not be excluded. Overall, we feel that because of the high sensitivity of the assay, extreme care should be taken about association of PCR results, efficacy of treatment and disease status.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Here we present a one-tube nested PCR test, which allows the detection of minimal quantities of Chlamydia trachomatis in human fluids. This assay includes the use of an internal control to avoid false negative results due to the presence of inhibitors. The results obtained show that this assay is robust enough to be used for clinical diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed at implementing a Nested-polymerase chain reaction (Nested-PCR) for the molecular diagnosis of human T-cell lymphotropic virus type I/II (HTLV-I and HTLV-II) infections in peripheral blood mononuclear cells of infected subjects in Argentina. The sensitivity and specificity of the assay for the detection of regional strains were assessed by comparing them with the molecular assay of reference PCR-hybridization. The Nested-PCR detected 1 MT-2 cell (³ 8 proviral copies)/1x106 non-infected cells showing high sensitivity for provirus detection. While both molecular assays showed high specificity (100%) for HTLV-I and HTLV-II detection, the sensitivity values differed: 100% for Nested-PCR and 67% for PCR-hybridization assay. Moreover, this technique showed less sensitivity for the detection of DNA sequences of HTLV-II (33%) than for the detection of DNA sequences of HTLV-I (75%). The high sensitivity and specificity of the Nested-PCR for regional strains and its low costs indicate that this assay could replace the PCR-hybridization assay for the molecular diagnosis of HTLV-I/II infections. It will be interesting to assess the usefulness of this assay as a tool for the molecular diagnosis of HTLV-I/II infections in other developing countries. Other studies that include a greater number of samples should be conducted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a nested reverse transcription-polymerase chain reaction (RT-PCR) assay for hantavirus using primers selected to match high homology regions of hantavirus genomes detected from the whole blood of hantavirus cardiopulmonary syndrome (HCPS) patients from Brazil, also including the N gene nucleotide sequence of Araraquara virus. Hantavirus genomes were detected in eight out of nine blood samples from the HCPS patients by RT-PCR (88.9% positivity) and in all 9 blood samples (100% positivity) by nested-PCR. The eight amplicons obtained by RT-PCR (P1, P3-P9), including one obtained by nested-PCR (P-2) and not obtained by RT-PCR, were sequenced and showed high homology (94.8% to 99.1%) with the N gene of Araraquara hantavirus. Although the serologic method ELISA is the most appropriate test for HCPS diagnosis, the use of nested RT-PCR for hantavirus in Brazil would contribute to the diagnosis of acute hantavirus disease detecting viral genomes in patient specimens as well as initial genomic characterization of circulating hantaviruses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A multiplex polymerase chain reaction (PCR) assay was performed on 167 thermophilic campylobacters isolated from non-human primates. Samples were first identified by phenotypic methods resulting in 64 Campylobacter jejuni and 103 C. coli strains. Four strains identified biochemically as C. coli, were then determined to be C. jejuni by PCR. Comparison of methodologies showed that the main discrepancies were attributed to the hippurate hydrolysis test and sensitivity to cephalothin and nalidixic acid. Analysis of data showed that the application of phenotypic methods should be supplemented by a molecular method to offer a more reliable Campylobacter identification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnosis of bacterial meningitis has long been based on classical methods of Gram stain, serological tests, and culture of cerebrospinal fluid (CSF). The performance of these methods, especially culture and direct smear, is thwarted by failure to detect bacteria following administration of antimicrobial agents and reluctance to performance lumbar punctures at admission. Indeed, patients with meningitis frequently receive antibiotics orally or by injection before the diagnosis is suspected or established. Thus an alternative method has become necessary to help clinicians and epidemiologists to management and control of bacterial meningitis. We evaluate the application of a polymerase chain reaction-based (PCR) assay for amplification of pneumolysin gene (ply) to diagnosis of Streptococcus pneumoniae meningitis. The PCR assay sensitivity for CSF was 96% (95% confidence interval, CI, 90-99%) compared to a sensitivity of 59% for culture (95% CI 49-69%), 66% for Gram stain (95% CI 56-74%), and 78% for latex agglutination test (95% CI 69-86%); PCR specificity was 100% (95% CI 83-100%). PCR results were available within 4 h of the start of the assay. This molecular approach proved to be reliable and useful to identify this bacterium compared with other classical laboratory methods for identification of bacterial meningitis pathogens.