990 resultados para BNCT, Strahlentherapie, ICP-MS, PGAA, Radiographie


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection (FI) system to match concentrations was used as an auto-diluter in multielement determination by inductively coupled plasma-mass spectrometry (ICP-MS). The flow system comprised loop-based injection or a timed valve that introduced a variable sample volume info a spray chamber through a standard Meinhard nebulizer of an ICP-MS. Routinely analyzed samples such as water, plant, and steel were selected. The accuracy of multielement determination was checked against water standard reference material from the National Institute of Standards and Technology (1643d), plant standard reference material from the National Bureau of Standards (1572 citrus leaves), and steel standard reference material from the National Bureau of Standards (AISI 4340). The measuring system was calibrated with a multielement solution, yielding a linear plot with good precision [relative standard deviation (RSD) < 3%, n = 12]. The results were in agreement at a 95% confidence level with the certified values for the reference materials and also with those obtained by continuous aspiration and by (FI) with a discrete volume. (C) 1999 John Wiley & Sons, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma-mass spectrometry (ICP-MS). Prior to analysis, 200 l of blood samples was mixed with 500 l of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 g//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Sante Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 g/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Throughout the world, biomonitoring has become the standard for assessing exposure of individuals to toxic elements as well as for responding to serious environmental public health problems. However, extensive biomonitoring surveys require rapid and simple analytical methods. Thus, a simple and high-throughput method is proposed for the determination of arsenic (As), cadmium (Cd), copper (Cu), manganese (Mn), nickel (Ni), lead (Pb), and selenium (Se) in blood samples by using inductively coupled plasma–mass spectrometry (ICPMS). Prior to analysis, 200 ml of blood samples was mixed with 500 ml of 10% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 10 min, and subsequently diluted to 10 ml with a solution containing 0.05% w/v ethylenediamine tetraacetic acid (EDTA) + 0.005% v/v Triton X-100. After that, samples were directly analyzed by ICP-MS (ELAN DRC II). Rhodium was selected as an internal standard with matrix-matching calibration. Method detection limits were 0.08, 0.04, 0.5, 0.09, 0.12, 0.04, and 0.1 mg//L for As, Cd, Cu, Mn, Ni, Pb, and Se, respectively. Validation data are provided based on the analysis of blood samples from the trace elements inter-\comparison program operated by the Institut National de Santé Publique du Quebec, Canada. Additional validation was provided by the analysis of human blood samples by the proposed method and by using electrothermal atomic absorption spectrometry (ETAAS). The method was subsequently applied for the estimation of background metal blood values in the Brazilian population. In general, the mean concentrations of As, Cd, Cu, Mn, Ni, Pb, and Se in blood were 1.1, 0.4, 890, 9.6, 2.1, 65.4, and 89.3 mg/L, respectively, and are in agreement with other global populations. Influences of age, gender, smoking habits, alcohol consumption, and geographical variation on the values were also considered. Smoking habits influenced the levels of Cd in blood. The levels of Cu, Mn, and Pb were significantly correlated with gender, whereas Cu and Pb were significantly correlated with age. There were also interesting differences in Mn and Se levels in the population living in the north of Brazil compared to the south.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O cádmio (Cd) é um metal tóxico considerado não essencial nos organismos. As principais vias de exposição e contaminação pelo metal vem de atividades antrópicas. Há evidências suficientes de que o Cd e seus compostos são carcinogênicos, tendo como principais órgãos afetados: rins, ossos, pulmões e próstata. No citosol o Cd pode estar na forma livre (genericamente, como complexos inorgânicos lábeis) ou ligado com metalotioneinas (genericamente, ligado a proteínas). A relação do Cd (livre ou lábil) com patogenicidades faz com que seja de grande importância a elaboração de métodos para especiação do metal. Este projeto teve como objetivo propor um método para determinação seletiva do Cd lábil em baixas concentrações (μg L-1) utilizando um substrato biológico como material sorvente (S. cerevisiae). A utilização da S. cerevisiae tem sido recomendada para pré-concentração e especiação de metais em água e materiais biológicos. No entanto, estes métodos não proporcionam limites de detecção (LD) suficientes para determinação seletiva de Cd lábil em algumas situações, particularmente quando se procura estabelecer uma relação desta fração do metal com algumas patogenicidades. O método desenvolvido consiste, basicamente, em amostrar o Cd lábil no citosol pela levedura. Depois de digestão ácida em sistema pressurizado (micro-ondas) e/ou da eluição, a espécie retida pela levedura foi determinada por ICP-MS. O uso da ICP-MS permitiu atingir LD suficientes para detecção de Cd, sendo para retenção 0,004 μg L-1 e para a eluição 0,003 μg L-1

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a rapid method for arsenic (As) speciation by LC-ICP-MS in several types of food samples. Prior to analysis, samples were milled and the As species extracted from biological tissues by sonication in only 2 min with a solution containing MeOH (10%, v/v) plus HNO3 (2%, v/v). As species were separated by LC using an anion exchange column. Method detection limits for AsB, As3+,DMA, MMA and As5+ were 1.3, 0.9, 0.6, 0.7 and 0.8 ng g(-1), respectively. Method accuracy and precision were traceable to Certified Reference Materials SRM1577 bovine liver from the National Institute of Standards and Technology, CE278 mussel tissue from the Institute of Reference Materials and Measurements and DOLT-3 dogfish liver tissue and DORM-3 fish protein from the National Research Council of Canada. Finally, the method was applied to speciate As in food samples (egg, fish muscle, beef and chicken) purchased in Brazilian markets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

LA-MC-ICP-MS U-Pb zircon dating was performed on syntectonic, early post-collisional granitic and associated mafic rocks that are intrusive in the Brusque Metamorphic Complex and in the Florianopolis Batholith, major tectonic domains separated by the Neoproterozoic Major Gercino Shear Zone (MGSZ) in south Brazil. The inferred ages of magmatic crystallization are consistent with field relationships, and show that the syntectonic granites from both domains are similar, with ages around 630-620 Ma for high-K calc-alkaline metaluminous granites and ca. 610 Ma for slightly peraluminous granites. Although ca. 650 Ma inherited zircon components are identified in granites from both domains, important contrasts on the crustal architecture in each domain are revealed by the patterns of zircon inheritance, indicating different crustal sources for the granites in each domain. The granites from the southern domain (Floriandpolis Batholith) have essentially Neoproterozoic (650-700 Ma and 900-950 Ma) inheritance; with a single 2.0-2.2 Ga inherited age obtained in the peraluminous Mariscal Granite. In the northern Brusque Metamorphic Complex, the metaluminous Rio Pequeno Granite and associated mafic rocks have scarce inherited cores with ages around 1.65 Ga, whereas the slightly peraluminous Serra dos Macacos Granite has abundant Paleoproterozoic (1.8-2.2 Ga) and Archean (2.9-3.4 Ga) inherited zircons. Our results are consistent with the hypothesis that the MGSZ separates domains with distinct geologic evolution; however, the contemporaneity of 630-610 Ma granitic magmatism with similar structural and geochemical patterns on both sides of this major shear zone indicates that these domains were already part of a single continental mass at 630 Ma, reinforcing the post-collisional character of these granites. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The LA-MC-ICP-MS method applied to U-Pb in situ dating is still rapidly evolving due to improvements in both lasers and ICP-MS. To test the validity and reproducibility of the method, 5 different zircon samples, including the standard Temora-2, ranging in age between 2.2 Ga and 246 Ma, were dated using both LA-MC-ICP-MS and SHRIMP. The selected zircons were dated by SHRIMP and, after gentle polishing, the laser spot was driven to the same site or on the same zircon phase with a 213 nm laser microprobe coupled to a multi-collector mixed system. The data were collected with a routine spot size of 25 μm and, in some cases, of 15 and 40 μm. A careful cross-calibration using a diluted U-Th-Pb solution to calculate the Faraday reading to counting rate conversion factors and the highly suitable GJ-1 standard zircon for external calibrations were of paramount importance for obtaining reliable results. All age results were concordant within the experimental errors. The assigned age errors using the LA-MC-ICP-MS technique were, in most cases, higher than those obtained by SHRIMP, but if we are not faced with a high resolution stratigraphy, the laser technique has certain advantages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit ist es gelungen, ein GC/ICP-MSIVA-Verfahren zur zuverlässigen und richtigen Bestimmung von Methylquecksilbergehalten (MeHg+) in aquatischen Systemen zu entwickeln. Unter Verwendung eines hergestellten Me201Hg+-Indikators konnte bei der Überprüfung der weltweit gängigen Probenaufbereitung mittels NaBEt4 zur Überführung von MeHg+ in MeEtHg gezeigt werden, daß während dieser Probenaufbereitung in Gegenwart von Halogeniden eine MeHg+-Speziesumwandlung zu Hg0 stattfinden kann. Es konnte mit Hilfe von Modellösungen erstmalig eindeutig nachgewiesen werden, daß die MeHg+-Speziesumwandlungen ihre Ursache nur im Zusammenwirken von vorliegenden Halogeniden mit dem verwendeten Derivatisierungsreagenz NaBEt4 haben. Ebenso wie in Modellösungen wurden auch MeHg+-Speziesumwandlungen in Realproben bei der Derivatisierung mit NaBEt4 überprüft. Die Proben, die bei der Derivatisierung mit NaBEt4 eine MeHg+-Umwandlung zeigten, wurden auch mit dem weltweit bisher wenig eingesetzten Reagenz NaBPr4 derivatisiert. Hier konnte bei keiner der Untersuchungen eine MeHg+-Umwandlung festgestellt werden. Des weiteren wurden MeHg+-Gehalte in Süßwasserproben unter Verwendung von NaBEt4 und NaBPr4 bestimmt. Die Ergebnisse hinsichtlich beider Derivatisierungsreagenzien stimmten sehr gut überein. Diese Resultate zeigten eindrucksvoll, daß Substanzverluste durch die Speziesumwandlung bei MeHg+-Bestimmungen mit MSIVA keine Rolle spielen, da die Umwandlung erst nach der Isotopenvermischung einsetzte. Mit dem entwickelten GC/ICP-MSIVA-Verfahrens wurde der MeHg+-Gehalt im Referenzmaterial CRM 463 analysiert, der sehr gut mit dem zertifizierten Wert übereinstimmte.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Deutsch:Schwerpunkt dieser Arbeit war die Entwicklung einer Methode zur Spurenbestimmung von Silicium in organischen und anorganischen Matrices unter Verwendung der massenspektrometrischen Isotopenverdünnungsanalyse (MSIVA) an einem hochauflösenden induktiv gekoppelten Plasma-Massenspektrometer (HR-ICP-MS). Zusätzlich zur Elementspurenbestimmung wurde eine GC/HR-ICP-MS Kopplung entwickelt, die zur Analyse linearer und cyclischer Siloxane verwendet wurde.Die hier entwickelte Analysenmethode erlaubt Nachweisgrenzen für Silicium sowohl in organischen als auch in anorganischen Matrices im oberen ng/g-Bereich und ergab für die im Rahmen dieser Arbeit analysierten Proben Reproduzierbarkeiten von < 20%. Durch einfache Verdünnung nach der Probenvorbereitung in Verbindung mit dem sehr empfindlichen Detektionsverfahren sowie der internen Standardisierung mittels MSIVA erlaubt das Verfahren eine präzise Bestimmung von Silicium in jeglicher Matrix. Neben der Schnelligkeit und Einfachheit eignet sich die hier entwickelte Methode besonders für die Routineanalytik. Die gute Reproduzierbarkeit und der Vergleich mit Ergebnissen von zwei Interlaborstudien unterstreicht zusätzlich die Fähigkeit präzise und richtige Ergebnisse zur Zertifizierung an Standardreferenzmaterialien bezüglich des Siliciums im Spurenbereich zu liefern.Neben dem Gesamtgehalt von Silicium konnten medizinisch relevante Siliciumverbindungen analysiert und quantifiziert werden. Hierbei wurden niedermolekulare Polydimethlysiloxane (PDMS) untersucht, die als Nebenprodukte vor allem in Brustimplantaten auftreten. Grundlage für die Bestimmung dieser Siliciumspezies ist die Kopplung eines hochauflösenden ICP-MS an einen Gaschromatographen. Der hohe Ionisierungsgrad des ICP, gerade unter trockenen Plasmabedingungen, und der elementspezifische und sehr empfindliche massenspektrometrische Detektor erlauben in Verbindung mit dem GC die Bestimmung von Siloxanen bis in den pg/g-Bereich. Aus der Bestimmung des Gesamtgehalts an Silicium und der Bestimmung des Gehalts an den untersuchten Siliciumverbindungen können Vergleiche gemacht werden. Die Analyse beider Parameter ist mit Hilfe in dieser Arbeit entwickelten Methode möglich.Zusätzlich zur Siliciumbestimmung wurde der Gehalt an Platin in Humanproben analysiert, da bei der Herstellung der Füllung von Siliconimplantaten Platinkatalysatoren verwendet werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dieser Arbeit wurde erstmalig eine massenspektrometrische Isotopenverdünnungsanalyse (MSIVA) als Quantifizierungsmethode für die Multielementbestimmung in pulverförmigen Proben mittels Laserablations-induktiv gekoppelter Plasma-Massenspektrometrie (LA-ICP-MS) entwickelt. Diese LA-ICP-MSIVA wurde zur Bestimmung von Elementspuren in optisch-reinem Calciumfluorid eingesetzt und anhand der Analyse mehrerer zertifizierter Referenzmaterialien unterschiedlicher Matrixzusammensetzung validiert.Mit den in dieser Arbeit entwickelten direkten LA-ICP-MS-Analysenmethoden dürfte es in der Zukunft möglich sein, Routineanalysen von optisch-reinem Calciumfluorid durchzuführen, wobei sich im Vergleich zu naßchemischen Aufschlußverfahren eindeutige Vorteile ergeben. Neben einer deutlich einfacheren und weniger kontaminationsanfälligen Probenvorbereitung liegen die Nachweisgrenzen (im Bereich von 0.05 ng/g für Zr bis 20 ng/g für Mg) um etwa ein bis drei Größenordnungen niedriger.Die am Beispiel der Multielementbestimmung in Calciumfluorid entwickelte LA-ICP-MSIVA wurde nachfolgend anhand der Analyse von sieben zertifizierten Referenzmaterialien mit organischer und anorganischer Matrix validiert. Hierbei wurde für 28 von insgesamt 32 analysierten Elementkonzentrationen eine hervorragende Übereinstimmung mit den zertifizierten Werten erhalten. Im Mittel weichen die mittels LA-ICP-MSIVA analysierten Gehalte nur um 1.6 % von den zertifizierten Werten ab. Die erzielte Präzision von durchschnittlich 4.9 % relativer Standardabweichung für drei unabhängig analysierte Proben liegt im Bereich der durchschnittlichen zertifizierten Unsicherheit der Referenzmaterialien von 4.4 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.