986 resultados para Atomic spectroscopy


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A donut-shaped spray chamber has been developed for the introduction of aerosol and/or volatile chemical species into the inductively coupled plasma. Compared with the Fassel-Scott spray chamber, it gives a higher efficiency of aerosol generation and transportation and superior stable inner pressure. As a result, it brings the benefits of higher intensity signal, lower background, higher measurement precision, and better detection limits. Using:his spray chamber, it is more convenient to introduce volatile chemical species into the sampling system, and more flexible for the choice of introducing aerosol and volatile chemical species separately or simultaneously into the plasma. It is also suitable for FIA technique. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this present work a method for the determination of Ca, Fe, Ga, Na, Si and Zn in alumina (Al(2)O(3)) by inductively coupled plasma optical emission spectrometry (ICP OES) with axial viewing is presented. Preliminary studies revealed intense aluminum spectral interference over the majority of elements and reaction between aluminum and quartz to form aluminosilicate, reducing drastically the lifetime of the torch. To overcome these problems alumina samples (250 mg) were dissolved with 5 mL HCl + 1.5 mLH(2)SO(4) + 1.5 mL H(2)O in a microwave oven. After complete dissolution the volume was completed to 20 mL and aluminum was precipitated as Al(OH)(3) with NH(3) (by bubbling NH(3) into the solution up to a pH similar to 8, for 10 min). The use of internal standards (Fe/Be, Ga/Dy, Zn/In and Na/Sc) was essential to obtain precise and accurate results. The reliability of the proposed method was checked by analysis of alumina certified reference material (Alumina Reduction Grade-699, NIST). The found concentrations (0.037%w(-1) CaO, 0.013% w w(-1) Fe(2)O(3), 0.012%w w(-1)Ga(2)O(3), 0.49% w w(-1) Na(2)O, 0.014% w w(-1) SiO(2) and 0.013% w w(-1) ZnO) presented no statistical differences compared to the certified values at a 95% confidence level. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work was to develop an appropriate sample preparation procedure for the flame atomic absorption spectrometry determination of Cu, Fe, Mn, and, Zn in rocks used in organic agriculture as a source of macro- and micronutrients.Six different procedures were evaluated and are classified into three groups: (a) pressure digestion system with Teflon bombs, (b) conventional wet digestion in a digester heating block, and (c) closed microwave system with pressure and temperature control.Two standard reference materials and two commercial samples were analyzed. It was found that the closed microwave system required low reagent consumption, less time, and resulted in low contamination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method for the direct determination of Ni in soft drinks by graphite furnace atomic absorption spectrometry using a transversely heated graphite atomizer (THGA), Zeeman-effect background corrector, and Co as the internal standard (IS) is proposed. Magnesium nitrate was used to stabilize both Ni and Co. All diluted samples (1+1) in 0.2% (v/v) HNO3 and reference solutions [5.0-50 mu g L-1 Ni in 0.2% (v/v) HNO3] were spiked with 50 mu g L-1 Co. For a 20-mu L sample dispensed into the atomizer, correlations between the ratio of absorbance of Ni to absorbance of Co and the analyte concentration were close to 0.9996. The relative standard deviation of the measurements varied from 0.5 to 3.4% and 1.0 to 7.0% (n=12) with and without IS, respectively. Recoveries within 98-104% for Ni spikes were obtained using IS. The characteristic mass was calculated as 43 pg Ni and the limit of detection was 1.4 mu g L-1. The accuracy of the method was checked for the direct determination of Ni in soft drinks and the results obtained with IS were better than those without IS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the development of an analytical procedure for on-line tin determination using thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). Two tubes were evaluated as atomization cells: a metallic tube (Ni-Cr, principal components composition: 73.95% Ni and 16.05% Cr) and a ceramic tube (99.8% Al2O3). The use of air as the carrier was made by employing a Rheodyne valve to inject the samples, allowing an analytical frequency of 90 h(-1) and avoiding sample dispersion. The carrier flow rate (air), sample volume injected, and acid concentration (HCl) were evaluated for the optimization of the TS-FF-AAS system. The sensitivity for 50 mL of analytical solution with TS-FF-AAS was 2 and 5 times higher (to metallic and ceramic tube, respectively) than using an acetylene-nitrous oxide flame with pneumatic aspiration (requiring a sample volume of approximately 20 times higher.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present paper describes the use of sugar cane bagasse as solid phase extractor for cadmium determination after complexation of the analyte with ammonium diethyldithiophosphate (ADDP) and sorption of the Cd-DDP complexes on the solid support. The concomitants were separated using a flow injection analysis (FIA) system coupled to flame atomic absorption spectrometry (FAAS) for determination. The main parameters such as ADDP concentration, acid medium, flow rate, reaction coil length, and reaction time were investigated.The results obtained with HNO3 showed good accuracy and precision. The enhancement factor was 20.5 times for a 120-second preconcentration time, and the analytical frequency was 25 determinations per hour. The calibration curve was linear over the concentration range of 1-40 mu g L-1 Cd with a LOD of 0.697 mu g L-1 Cd and a relative standard deviation of 0.96% after 12 successive measurements of 30 mu g L-1 Cd.The proposed method was evaluated for the FIA-FAAS analysis of certified reference materials (tomato leaves, spinach leaves, and bovine liver) and Cd-spiked foods (shrimp, sardine, tuna, chicken liver and bovine liver). Good recoveries (80.0-97.1%) for the Cd-spiked samples and certified reference materials were obtained. The results of bagasse-packed minicolumns were compared with Si-C,8 packed minicolumns. The F-test was applied between Si-C-18/Bagasse minicolumns, Si-C-18/certified values, and bagasse/certified values. It was found that the results were in agreement with the certified values at a 95% confidence level.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method has been developed for the direct and simultaneous determination of As, Cu, Mn, Sb, and Se in drinking water by electrothermal atomic absorption spectrometry (ETAAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect back- ground correction. The thermal behavior of analytes during the pyrolysis and atomization stages was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3 and 1 + 1 (v/v) diluted water using mixtures of Pd(NO3)(2) + Mg(NO3)(2) as the chemical modifier, With 5 mug Pd + 3 mug Mg as the modifier, the pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1400degreesC and 2100degreesC, respectively, and 20 muL of the water sample (sample + 0.28 mol L-1 HNO3, 1 + 1, v/v), dispensed into the graphite tube, analytical curves were established ranging from 5.00 - 50.0 mug L-1 for As, Sb, Se; 10.0 - 100 mug L-1 for Cu; and 20.0 - 200 mug L-1 for Mn. The characteristic masses were around 39 pg As, 17 pg Cu, 60 pg Mn, 43 pg Sb, and 45 pg Se, and the lifetime of the tube was around 500 firings. The limits of detection (LOD) based on integrated absorbance (0.7 mug L-1 As, 0.2 mug L-1 Cu, 0.6 mug L-1 Mn, 0.3 mug L-1 Sb, 0.9 mug L-1 Se) exceeded the requirements of the Brazilian Food Regulations (decree # 310-ANVS from the Health Department), which established the maximum permissible level for As, Cu, Mn, Sb, and Se at 50 mug L-1, 1000 mug L-1, 2000 mug L-1, 5 mug L-1, and 50 mug L-1, respectively. The relative standard deviations (n = 12) were typically < 5.3% for As, < 0.5% for Cu, < 2.1% for Mn, < 11.7% for Sb, and < 9.2% for Se. The recoveries of As, Cu, Mn, Sb, and Se added to the mineral water samples varied from 102-111%, 91-107%, 92-109%, 89-97%, and 101-109%, respectively. Accuracy for the determination of As, Cu, Mu Sb and Se was checked using standard reference materials NIST SRM 1640 - Trace Elements in Natural Water, NIST SRM 1643d - Trace Elements in Water, and 10 mineral water samples. A paired t-test showed that the results were in agreement with the certified values of the standard reference materials at the 95% confidence level.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method has been developed for the simultaneous determination of Al, As, Cu, Fe, Mn, and Ni in fuel ethanol by graphite furnace atomic absorption spectrometry (GFAAS) using a transversely heated graphite atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of analytes during the pyrolysis and atomization stages using the mixture Pd(NO3)(2) + Mg(NO3)(2) as the chemical modifier was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3, and diluted ethanol (1 + 1, v/v) containing different nitric acid concentrations. With 5 rhog Pd + 3 mug Mg as the modifiers, pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1200 C and 2200degreesC respectively. For 20 muL of diluted sample (10 muL ethanol + 10 muL of 0.28 mol L-1 HNO3) dispensed into the graphite tube, analytical curves in the 2.0 - 50 mug L-1 Al, As, Cu, Fe, Mn, Ni ranges were established. The calculated characteristic masses were - 37 pg Al, 73 pg As, 31 pg Cu, 16 pg Fe, 9 pg Mn, and 44 pg Ni, and the lifetime of the tube was around 2 50 firings. The limits of detection (LOD) based on integrated absorbance were 1.2 mug L-1 Al, 2.5 mug L-1 As. 0.22 mug L-1 Cu, 1.6 L-1 Fe 0.20 mug L-1 Mn 1.1 mug L-1 Ni. The relatively standard deviations (n = 12) were less than or equal to 3%, less than or equal to 6%, less than or equal to 2%, less than or equal to 3.4%, less than or equal to 1.3%, and less than or equal to 2% for Al, As, Cu, Fe, Mn, and Ni, respectively, the recoveries of Al, As, Cu, Fe, Mn and Ni added to fuel ethanol samples varied from 77% to 112%, 92% to 114%, 104% to 113%, 73% to 116%, 91% to 122% and 93% to 116%, respectively. Accuracy was checked for Al, As, Cu, Fe, Mn, and Ni determination in 20 samples purchased at local gas stations in Araraquara city, Brazil. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained by single-element GFAAS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(Ill) (after on-line solid-liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid-liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to online pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 mu g L-1 were obtained for total Sb and Sb (III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81 19 and I I I 15% when 120 s of sample loading were used. (c) 2006 Elsevier B.V. All rights reserved.