983 resultados para Arm-swinging
Resumo:
The benefit of bevacizumab (Bv) has been shown in different tumors including colorectal cancer, renal cancer, pulmonary non-small cell cancer and also breast cancer. However to date, there is no established test evaluating the angiogenic status of a patient and monitoring the effects of anti-angiogenic treatments. Tumor angiogenesis is the result of a balance between multiple pro- and anti¬angiogenic molecules. There is very little published clinical data exploring the impact of the anti-angiogenic therapy on the different angiogenesis-related molecules and the potential role of these molecules as prognostic or predictive factors.
Resumo:
Bone-mounted robotic guidance for pedicle screw placement has been recently introduced, aiming at increasing accuracy. The aim of this prospective study was to compare this novel approach with the conventional fluoroscopy assisted freehand technique (not the two- or three-dimensional fluoroscopy-based navigation). Two groups were compared: 11 patients, constituting the robotical group, were instrumented with 64 pedicle screws; 23 other patients, constituting the fluoroscopic group, were also instrumented with 64 pedicle screws. Screw position was assessed by two independent observers on postoperative CT-scans using the Rampersaud A to D classification. No neurological complications were noted. Grade A (totally within pedicle margins) accounted for 79% of the screws in the robotically assisted and for 83% of the screws in the fluoroscopic group respectively (p = 0.8). Grade C and D screws, considered as misplacements, accounted for 4.7% of all robotically inserted screws and 7.8% of the fluoroscopically inserted screws (p = 0.71). The current study did not allow to state that robotically assisted screw placement supersedes the conventional fluoroscopy assisted technique, although the literature is more optimistic about the former.
Resumo:
Résumé en français: Il est admis que l'inflation d'une manchette à pression au niveau du bras engendre une augmentation réactionnelle de la tension artérielle qui peut être le résultat d'une gêne lors de l'inflation et peut diminuer la précision de la mesure. Dans cette étude, nous comparons séquentiellement l'augmentation de la tension artérielle lorsque la manchette à pression est positionnée au niveau du bras et au niveau du poignet. Nous avons étudié un collectif de 34 participants normotendus et 34 patients hypertendus. Chacun d'eux était équipé de deux manchettes à pression, l'une au niveau du bras et l'autre au niveau du poignet. Nous avons randomisé l'ordre d'inflation des manchettes ainsi que la pression d'inflation maximale (180mmHg versus 240mmHg). Trois mesures étaient effectuées pour chaque pression d'inflation maximale, ceci au bras comme poignet, et leur séquence était également randomisée. En parallèle, un enregistrement continu de la tension artérielle avait lieu au niveau du majeur de la main opposée à l'aide d'un photoplethysmographe. Cette valeur était considérée comme la valeur de tension artérielle au repos. Pour les participants normotendus, aucune différence statistiquement significative n'a pu être mise en évidence en lien avec la position de la manchette à pression, ceci indépendamment de la pression d'inflation maximale. Variation de la pression systolique à 180 mmHg: 4.3+/-3.0 mmHg au bras et 3.7+/-2.9 mmHg au poignet (p=ns), à 240 mmHg: 5.5+/-3.9 au bras et 4.2+/-2.7 mmHg au poignet (p=0.052). En revanche, concernant les patients hypertendus, une augmentation significative de la tension artérielle a été mise en évidence entre le bras et le poignet. Ceci pour les valeurs de tension artérielle systolique et diastolique et quelle que soit la pression d'inflation maximale utilisée. Augmentation de la pression artérielle systolique 6.513.5 mmHg au bras et 3.812.1mmHg au poignet pour une pression d'inflation maximale de 180 mmHg (p<0.01) et respectivement 6.413.5 mmHg et 4.713.0 mmHg pour 240 mmHg (p=0.01). L'augmentation des valeurs de tension artérielle était indépendante de la valeur tensionnelle de base. Ces résultats montrent que les patients hypertendus réagissent significativement moins à l'inflation d'une manchette ä pression lorsque celle-ci est positionnée au niveau du poignet par rapport au bras, ceci indépendamment des valeurs de tension artérielle de base des patients. Nous pouvons donc suggérer que l'inflation d'une manchette à pression cause moins de désagrément lorsqu'elle est placée au niveau du poignet, notamment chez les patients hypertendus et qu'elle peut être une alternative à la mesure standard au niveau du bras.
Resumo:
Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.
Resumo:
BACKGROUND Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). METHODS Treatment: gefitinib 250 mg day(-1) until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. RESULTS Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8%; adenocarcinoma 97.2%; never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5-77.7), DCR 90.6% (95% CI 83.5-94.8), median PFS 9.7 months (95% CI 8.5-11.0), median OS 19.2 months (95% CI 17.0-NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15%; SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8-74.7). CONCLUSION First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable.
Resumo:
BACKGROUND: Phase-IV, open-label, single-arm study (NCT01203917) to assess efficacy and safety/tolerability of first-line gefitinib in Caucasian patients with stage IIIA/B/IV, epidermal growth factor receptor (EGFR) mutation-positive non-small-cell lung cancer (NSCLC). METHODS: TREATMENT: gefitinib 250 mg day(-1) until progression. Primary endpoint: objective response rate (ORR). Secondary endpoints: disease control rate (DCR), progression-free survival (PFS), overall survival (OS) and safety/tolerability. Pre-planned exploratory objective: EGFR mutation analysis in matched tumour and plasma samples. RESULTS: Of 1060 screened patients with NSCLC (859 known mutation status; 118 positive, mutation frequency 14%), 106 with EGFR sensitising mutations were enrolled (female 70.8%; adenocarcinoma 97.2%; never-smoker 64.2%). At data cutoff: ORR 69.8% (95% confidence interval (CI) 60.5-77.7), DCR 90.6% (95% CI 83.5-94.8), median PFS 9.7 months (95% CI 8.5-11.0), median OS 19.2 months (95% CI 17.0-NC; 27% maturity). Most common adverse events (AEs; any grade): rash (44.9%), diarrhoea (30.8%); CTC (Common Toxicity Criteria) grade 3/4 AEs: 15%; SAEs: 19%. Baseline plasma 1 samples were available in 803 patients (784 known mutation status; 82 positive; mutation frequency 10%). Plasma 1 EGFR mutation test sensitivity: 65.7% (95% CI 55.8-74.7). CONCLUSION: First-line gefitinib was effective and well tolerated in Caucasian patients with EGFR mutation-positive NSCLC. Plasma samples could be considered for mutation analysis if tumour tissue is unavailable.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Ideally, reconstruction of lower extremity soft tissue defects includes not only an esthetically pleasing 3-dimensional shape and solid anchoring to the underlying structures to resist shear forces, but should also address the restoration of sensation. Therefore, we present a prospective study on defect reconstruction of the lower leg and ankle to evaluate the role of sensate free fasciocutaneous lateral arm flap and the impact of sensory nerve reconstruction. Thirty patients were allocated randomly to the study group (n = 15) that obtained end-to-side sensate coaptation using the lower lateral cutaneous brachial nerve to the tibial nerve using the epineural window technique, or to the control group reconstructed without nerve coaptation. At 1-year follow-up the patients were evaluated for pain sensation, thermal sensibility, static and moving 2-point discrimination, and Semmes-Weinstein monofilament tests. Data from both groups were compared and statistically analyzed with the Mann-Whitney U test and the Fisher exact test. Flaps of the study group reached a static and moving 2-point discrimination and Semmes-Weinstein monofilament tests nearly equal to the contralateral leg area and significantly better than flaps of the control group. Donor damage morbidity of the tibial nerve did not occur. To our point of view resensation should be carried out by end-to-side neurorrhaphy to the tibial nerve because of the superior restoration of sensibility.
Resumo:
The aim of the present study was to determine whether and how rats can use local olfactory cues for spatial orientation. Rats were trained in an eight-arm radial maze under different conditions as defined by the presence or absence of supplementary olfactory cues marking each arm, the availability of distant visuospatial information, and the illumination of the maze (light or darkness). The different visual conditions were designed to dissociate among the effects of light per se and those of visuospatial cues, on the use of olfactory cues for accurate arm choice. Different procedures with modifications of the arrangement of olfactory cues were used to determine if rats formed a representation of the spatial configuration of the olfactory cues and if they could rely on such a representation for accurate arm choice in the radial maze. The present study demonstrated that the use of olfactory cues to direct arm choice in the radial arm maze was critically dependent on the illumination conditions and implied two different modes of processing of olfactory information according to the presence or the absence of light. Olfactory cues were used in an explicit manner and enabled accurate arm choice only in the absence of light. Rats, however, had an implicit memory of the location of the olfactory cues and formed a representation of the spatial position of these cues, whatever the lighting conditions. They did not memorize the spatial configuration of the olfactory cues per se but needed these cues to be linked to the external spatial frame of reference.
Resumo:
The goals of the human genome project did not include sequencing of the heterochromatic regions. We describe here an initial sequence of 1.1 Mb of the short arm of human chromosome 21 (HSA21p), estimated to be 10% of 21p. This region contains extensive euchromatic-like sequence and includes on average one transcript every 100 kb. These transcripts show multiple inter- and intrachromosomal copies, and extensive copy number and sequence variability. The sequencing of the "heterochromatic" regions of the human genome is likely to reveal many additional functional elements and provide important evolutionary information.
Resumo:
This paper estimates the effect of judicial institutions on governance at the local level in Brazil. Our estimation strategy exploits a unique institutional feature of state judiciary branches which assigns prosecutors and judges to the most populous among contiguous counties forming a judiciary district. As a result of this assignment mechanism there are counties with nearly identical populations, some with and some without local judicial presence, which we exploit to impute counterfactual outcomes. Conditional on observable county characteristics, offenses per civil servant are about 35% lower in counties that have a local seat of the state judiciary. The lower incidence of infractions stems mostly from fewer violations of financial management regulations by local administrators, fewer instances of problems in project execution and project managment, fewer cases of non-existent or ineffective civil society oversight and fewer cases of improper handling of remittances to local residents.