984 resultados para April 25th


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Increasing health care costs, limited resources and increased demand makes cost effective and cost-efficient delivery of Adolescent Idiopathic Scoliosis (AIS) management paramount. Rising implant costs in deformity correction surgery have prompted analysis of whether high implant densities are justified. The objective of this study was to analyse the costs of thoracoscopic scoliosis surgery, comparing initial learning curve costs with those of the established technique and to the costs involved in posterior instrumented fusion from the literature. METHODS: 189 consecutive cases from April 2000 to July 2011 were assessed with a minimum of 2 years follow-up. Information was gathered from a prospective database covering perioperative factors, clinical and radiological outcomes, complications and patient reported outcomes. The patients were divided into three groups to allow comparison; 1. A learning curve cohort, 2. An intermediate cohort and 3. A third cohort of patients, using our established technique. Hospital finance records and implant manufacturer figures were corrected to 2013 costs. A literature review of AIS management costs and implant density in similar curve types was performed. RESULTS: The mean pre-op Cobb angle was 53°(95%CI 0.4) and was corrected postop to mean 22.9°(CI 0.4). The overall complication rate was 20.6%, primarily in the first cohort, with a rate of 5.6% in the third cohort. The average total costs were $46,732, operating room costs of $10,301 (22.0%) and ICU costs of $4620 (9.8%). The mean number of screws placed was 7.1 (CI 0.04) with a single rod used for each case giving average implant costs of $14,004 (29.9%). Comparison of the three groups revealed higher implant costs as the technique evolved to that in use today, from $13,049 in Group 1 to $14577 in Group 3 (P<0.001). Conversely operating room costs reduced from $10,621 in Group 1 to $7573 (P<0.001) in Group 3. ICU stay was reduced from an average of 1.2 to 0 days. In-patient stay was significantly (P=0.006) lower in Groups 2 and 3 (5.4 days) than Group 1 (5.9 days) (i.e. a reduction in cost of approximately $6,140). CONCLUSIONS: The evolution of our thoracoscopic anterior scoliosis correction has resulted in an increase in the number of levels fused and reduction in complication rate. Implant costs have risen as a result, however, there has been a concurrent decrease in those costs generated by operating room use, ICU and in-patient stay with increasing experience. Literature review of equivalent curve types treated posteriorly shows similar perioperative factors but higher implant density, 69-83% compared to the 50% in this study. Thoracoscopic Scoliosis surgery presents a low density, reliable, efficient and effective option for selected curves. A cost analysis of Thoracoscopic Scoliosis Surgery using financial records and a prospectively collected database of all patients since 2000, demonstrating a clear cost advantage compared to equivalent posterior instrumentation and fusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Intervertebral stapling is a leading method of fusionless scoliosis treatment which attempts to control growth by applying pressure to the convex side of a scoliotic curve in accordance with the Hueter-Volkmann principle. In addition to that, staples have the potential to damage surrounding bone during insertion and subsequent loading. The aim of this study was to assess the extent of bony structural damage including epiphyseal injury as a result of intervertebral stapling using an in vitro bovine model. Materials and Methods Thoracic spines from 6-8 week old calves were dissected and divided into motion segments including levels T4-T11 (n=14). Each segment was potted in polymethylemethacrylate. An Instron Biaxial materials testing machine with a custom made jig was used for testing. The segments were tested in flexion/extension, lateral bending and axial rotation at 37⁰C and 100% humidity, using moment control to a maximum 1.75 Nm with a loading rate of 0.3 Nm per second for 10 cycles. The segments were initially tested uninstrumented with data collected from the tenth load cycle. Next an anterolateral 4-prong Shape Memory Alloy (SMA) staple (Medtronic Sofamor Danek, USA) was inserted into each segment. Biomechanical testing was repeated as before. The staples were cut in half with a diamond saw and carefully removed. Micro-CT scans were performed and sagittal, transverse and coronal reformatted images were produced using ImageJ (NIH, USA).The specimens were divided into 3 grades (0, 1 and 2) according to the number of epiphyses damaged by the staple prongs. Results: There were 9 (65%) segments with grade 1 staple insertions and 5 (35%) segments with grade 2 insertions. There were no grade 0 staples. Grade 2 spines had a higher stiffness level than grade 1 spines, in all axes of movement, by 28% (p=0.004). This was most noted in flexion/extension with an increase of 49% (p=0.042), followed by non-significant change in lateral bending 19% (p=0.129) and axial rotation 8% (p=0.456) stiffness. The cross sectional area of bone destruction from the prongs was only 0.4% larger in the grade 2 group compared to the grade 1 group (p=0.961). Conclusion Intervertebral staples cause epiphyseal damage. There is a difference in stiffness between grade 1 and grade 2 staple insertion segments in flexion/extension only. There is no difference in the cross section of bone destruction as a result of prong insertion and segment motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction There is growing interest in the biomechanics of ‘fusionless’ implant constructs used for deformity correction in the thoracic spine. Intervertebral stapling is a leading method of fusionless corrective surgery. Although used for a number of years, there is limited evidence as to the effect these staples have on the stiffness of the functional spinal unit. Materials and Methods Thoracic spines from 6-8 week old calves were dissected and divided into motion segments including levels T4-T11 (n=14). Each segment was potted in polymethylemethacrylate. An Instron Biaxial materials testing machine with a custom made jig was used for testing. The segments were tested in flexion/extension, lateral bending and axial rotation at 37⁰C and 100% humidity, using moment control to a maximum 1.75 Nm with a loading rate of 0.3 Nm per second. This torque was found sufficient to achieve physiologically representative ranges of movement. The segments were initially tested uninstrumented with data collected from the tenth load cycle. Next a left anterolateral Shape Memory Alloy (SMA) staple was inserted (Medtronic Sofamor Danek, USA). Biomechanical testing was repeated as before with data collected from the tenth load cycle. Results In flexion/extension there was an insignificant drop in stiffness of 3% (p=0.478). In lateral bending there was a significant drop in stiffness of 21% (p<0.001). This was mainly in lateral bending away from the staple, where the stiffness reduced by 30% (p<0.001). This was in contrast to lateral bending towards the staple where it dropped by 12% which was still statistically significant (p=0.036). In axial rotation there was an overall near significant drop in stiffness of 11% (p=0.076). However, this was more towards the side of the staple measuring a decrease of 14% as opposed to 8% away from the staple. In both cases it was a statistically insignificant drop (p=0.134 and p=0.352 respectively). Conclusion Insertion of intervertebral SMA staples results in a significant reduction in motion segment stiffness in lateral bending especially in the direction away from the staple. The staple had less effect on axial rotation stiffness and minimal effect on flexion/extension stiffness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The CSIRO Indigenous Livelihoods Project sought to work with Indigenous communities, government and non-government stakeholders to bring together western science and Indigenous knowledge in order to understand the potential livelihood benefits of enterprises based on natural resource management. The research focus was to enhance livelihood opportunities for Indigenous communities derived from new enterprises and activities based on natural resource management in regional and remote Australia. Underpinning outcomes were: · Identification of effective policy and institutional arrangements required to establish and maintain sustainable livelihoods; · Improved systems understanding of factors that enhance or inhibit sustainable livelihoods based on natural resource management; · Tools and methods for measuring the livelihood benefits of natural resource management; · Education, training, employment and capacity building for Indigenous communities and researchers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinically, the Cobb angle method measures the overall scoliotic curve in the coronal plane but does not measure individual vertebra and disc wedging. The contributions of the vertebrae and discs in the growing scoliotic spine were measured using sequential MRI scans to investigate coronal plane deformity progression with growth. Sequential MRI data showed complex patterns of deformity progression. Changes to the wedging of individual vertebrae and discs may occur in patients who have no increase in overall Cobb angle measure; the Cobb method alone may be insufficient to capture the complex mechanisms of deformity progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poems by Vera LaRouche compiled in North Africa between December 10, 1940 and April 1, 1942. (6p/typed)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes F 9244 - F 9263

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biography of Hermann Falck and story of his execution; contains copies of various letters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obverse: 10 Lirot silver coin; inscription. Reverse: Part of Israel's Declaration of Independence with the signatures of the founding fathers of the state of Israel, David Ben Gurion's signature is in the upper right.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obverse: Silver 10 Lirot coin with inscription. Reverse: Part of Israel's Declaration of Independence with signature of the founding fathers of the State of Israel, David Ben Gurion's signature is in the upper right part of the coin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obverse: Official emblem of the Israel's 25th Anniversary, menorah entwined by ribbon creating the number 25. Reverse: The twelve signs of Zodiac seen on the mosaic of a 6th century synagogue floor discovered in Beth Alpha.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obverse: Inscription. Reverse: The life insurance emblem, a house with family inside, shekel coin on the roof of the house.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many cases, a mobile user has the option of connecting to one of several IEEE 802.11 access points (APs),each using an independent channel. User throughput in each AP is determined by the number of other users as well as the frame size and physical rate being used. We consider the scenario where users could multihome, i.e., split their traffic amongst all the available APs, based on the throughput they obtain and the price charged. Thus, they are involved in a non-cooperative game with each other. We convert the problem into a fluid model and show that under a pricing scheme, which we call the cost price mechanism, the total system throughput is maximized,i.e., the system suffers no loss of efficiency due to selfish dynamics. We also study the case where the Internet Service Provider (ISP) could charge prices greater than that of the cost price mechanism. We show that even in this case multihoming outperforms unihoming, both in terms of throughput as well as profit to the ISP.