41 resultados para Anisometropia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Professor Nathan Efron recounts his experience in ‘visual no-man’s land’ – a particularly stressful phase of his ophthalmic journey of retinopexy, cryopexy, vitrectomy and IOL surgery attributed to extreme surgically-induced anisometropia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accommodation is considered to be a symmetrical response and to be driven by the least ametropic and nonamblyopic eye in anisometropia. We report the case of a 4-year-old child with anisometropic amblyopia who accommodates asymmetrically, reliably demonstrating normal accommodation in the nonamblyopic eye and antiaccommodation of the amblyopic eye to near targets. The abnormal accommodation of the amblyopic eye remained largely unchanged during 7 subsequent testing sessions undertaken over the course of therapy. We suggest that a congenital dysinnervation syndrome may result in relaxation of accommodation in relation to near cues and might be a hitherto unconsidered additional etiological factor in anisometropic amblyopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study model: observacional, retrospective. Objective: to determine the frequence of the ametropic errors and other ocular problems in children with 2 to 8 year-old at Piracicaba - SP. Patients and Method: During the school year of 2000, 1001 children enrolled at the public schools of Piracicaba - SP, age ranged from 2 to 8 years old, were referred to complete ophthalmological exam. Visual acuity was previously determined using Snellen chart, applied by school teachers. Those children presenting visual acuity equal or less than 0.8, visual complaints or visual disorders were selected to appointment. Results: 51 children (5.09%) did not attended to examination. 950 children were submitted to complete ophthalmological exam. Ametropic errors were found 70.84% of the children. The most prevalent refractive errors were Hypermetropic Astigmatism (49.62%) and Hypermetropia (32,98%). Anisometropia was found in 1.78% children. Other ocular disabilities accounted for 10.21% of the examined children, such as strabismus (3.36%), eyelid changes, allergic conjunctivitis, congenital dacryostenosis, optic atrophy, corioretinitis and congenital glaucoma. Conclusion: The frequence of ocular problems observed let us to conclude the screening programs are valid surveys on decreasing rates of preventable blindness in our country.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: to evaluate the causes and the results of occlusion amblyopia treatment. Methods: a retrospective study was done including children under 12 years old. Sex, age of starting treatment, etiology, ocular deviation affection, visual acuity and time for the occlusion treatment were evaluated. Results: 158 children had all the requirements to compose the sample. 50.6% were males. 70.2% had esotropia, 13.2% exotropia, 0.7% hypertropia and 4.4% presented horizontal and vertical strabismus. 11.4% had no ocular deviation. 6.6% presented anisometropia, 0.7% congenital cataract and 6.6% other diagnoses. Visual acuity improved in 85.5%, faster in the ortophoric children. The occlusion treatment time was long in all the deviation types. Conclusion: the treatment was beneficial in improving amblyopia in the majority of the children evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Macular pigment (MP) is the collective name for three carotenoids, lutein, zeaxanthin and meso-zeaxanthin, which are found at high concentrations in the central macula. The macular carotenoids, like all carotenoids, are entirely of dietary origin. The term ‘macular pigment optical density’ (MPOD) refers to the peak concentration of MP in the retina, which varies from one individual to the next and is measurable in vivo. On account of its blue-light-filtering and antioxidant properties, MP has become a subject of interest with respect to age-related macular degeneration (AMD), the hypothesis being that MP helps to protect against AMD; the higher the MPOD, the lower the risk for AMD. Recently, a new MPOD-measuring device, the MPS 9000 (MPS), entered the ophthalmic market. Using this device, the research described here aimed to contribute new information to the MP literature. A second MPOD instrument, the Macular Pigment Reflectometer, was also used at times, but a reliability study (included in the thesis) demonstrated that it was unsuitable for use on its own. First, a series of exploratory investigations were undertaken to maximize the accuracy and consistency of MPOD measurements taken with the MPS; a protocol was established that substantially improved repeatability. Subsequently, a series of MPOD-based studies were conducted on anisometropia, South Asian race, blue-light-filtering contact lenses, and dietary modification with kale. The principle findings were as follows: interocular MPOD differences were not attributable to interocular refractive error differences; young adults of South Asian origin had significant gender-related MPOD differences (males>females, p<0.01), and they also had significantly higher MPOD than Caucasians (p<0.0005); wearing blue-light-filtering contact lenses for eight months did not affect MPOD; and dietary modification with kale for 16 weeks did not increase MPOD. This body of research adds new insights to MP knowledge, which in turn may contribute to MP knowledge in the context of AMD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Distortion or deprivation of vision during an early `critical' period of visual development can result in permanent visual impairment which indicates the need to identify and treat visually at-risk individuals early. A significant difficulty in this respect is that conventional, subjective methods of visual acuity determination are ineffective before approximately three years of age. In laboratory studies, infant visual function has been quantified precisely, using objective methods based on visual evoked potentials (VEP), preferential looking (PL) and optokinetic nystagmus (OKN) but clinical assessment of infant vision has presented a particular difficulty. An initial aim of this study was to evaluate the relative clinical merits of the three techniques. Clinical derivatives were devised, the OKN method proved unsuitable but the PL and VEP methods were evaluated in a pilot study. Most infants participating in the study had known ocular and/or neurological abnormalities but a few normals were included for comparison. The study suggested that the PL method was more clinically appropriate for the objective assessment of infant acuity. A study of normal visual development from birth to one year was subsequently conducted. Observations included cycloplegic refraction, ophthalmoscopy and preferential looking visual acuity assessment using horizontally and vertically oriented square wave gratings. The aims of the work were to investigate the efficiency and sensitivity of the technique and to study possible correlates of visual development. The success rate of the PL method varied with age; 87% of newborns and 98% of infants attending follow-up successfully completed at least one acuity test. Below two months monocular acuities were difficult to secure; infants were most testable around six months. The results produced were similar to published data using the acuity card procedure and slightly lower than, but comparable with acuity data derived using extended PL methods. Acuity development was not impaired in infants found to have retinal haemorrhages as newborns. A significant relationship was found between newborn binocular acuity and anisometropia but not with other refractive findings. No strong or consistent correlations between grating acuity and refraction were found for three, six or twelve months olds. Improvements in acuity and decreases in levels of hyperopia over the first week of life were suggestive of recovery from minor birth trauma. The refractive data was analysed separately to investigate the natural history of refraction in normal infants. Most newborns (80%) were hyperopic, significant astigmatism was found in 86% and significant anisometropia in 22%. No significant alteration in spherical equivalent refraction was noted between birth and three months, a significant reduction in hyperopia was evident by six months and this trend continued until one year. Observations on the astigmatic component of the refractive error revealed a rather erratic series of changes which would be worthy of further investigation since a repeat refraction study suggested difficulties in obtaining stable measurements in newborns. Astigmatism tended to decrease between birth and three months, increased significantly from three to six months and decreased significantly from six to twelve months. A constant decrease in the degree of anisometropia was evident throughout the first year. These findings have implications for the correction of infantile refractive error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To study, for the first time, the effect of wearing ready-made glasses and glasses with power determined by self-refraction on children's quality of life. METHODS: This is a randomized, double-masked non-inferiority trial. Children in grades 7 and 8 (age 12-15 years) in nine Chinese secondary schools, with presenting visual acuity (VA) ≤6/12 improved with refraction to ≥6/7.5 bilaterally, refractive error ≤-1.0 D and <2.0 D of anisometropia and astigmatism bilaterally, were randomized to receive ready-made spectacles (RM) or identical-appearing spectacles with power determined by: subjective cycloplegic retinoscopy by a university optometrist (U), a rural refractionist (R) or non-cycloplegic self-refraction (SR). Main study outcome was global score on the National Eye Institute Refractive Error Quality of Life-42 (NEI-RQL-42) after 2 months of wearing study glasses, comparing other groups with the U group, adjusting for baseline score. RESULTS: Only one child (0.18%) was excluded for anisometropia or astigmatism. A total of 426 eligible subjects (mean age 14.2 years, 84.5% without glasses at baseline) were allocated to U [103 (24.2%)], RM [113 (26.5%)], R [108 (25.4%)] and SR [102 (23.9%)] groups, respectively. Baseline and endline score data were available for 398 (93.4%) of subjects. In multiple regression models adjusting for baseline score, older age (p = 0.003) and baseline spectacle wear (p = 0.016), but not study group assignment, were significantly associated with lower final score. CONCLUSION: Quality of life wearing ready-mades or glasses based on self-refraction did not differ from that with cycloplegic refraction by an experienced optometrist in this non-inferiority trial.