993 resultados para Air sampling apparatus.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper is concerned with the optimal path planning and initialization interval of one or two UAVs in presence of a constant wind. The method compares previous literature results on synchronization of UAVs along convex curves, path planning and sampling in 2D and extends it to 3D. This method can be applied to observe gas/particle emissions inside a control volume during sampling loops. The flight pattern is composed of two phases: a start-up interval and a sampling interval which is represented by a semi-circular path. The methods were tested in four complex model test cases in 2D and 3D as well as one simulated real world scenario in 2D and one in 3D.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main objective of this paper is to describe the development of a remote sensing airborne air sampling system for Unmanned Aerial Systems (UAS) and provide the capability for the detection of particle and gas concentrations in real time over remote locations. The design of the air sampling methodology started by defining system architecture, and then by selecting and integrating each subsystem. A multifunctional air sampling instrument, with capability for simultaneous measurement of particle and gas concentrations was modified and integrated with ARCAA’s Flamingo UAS platform and communications protocols. As result of the integration process, a system capable of both real time geo-location monitoring and indexed-link sampling was obtained. Wind tunnel tests were conducted in order to evaluate the performance of the air sampling instrument in controlled nonstationary conditions at the typical operational velocities of the UAS platform. Once the remote fully operative air sampling system was obtained, the problem of mission design was analyzed through the simulation of different scenarios. Furthermore, flight tests of the complete air sampling system were then conducted to check the dynamic characteristics of the UAS with the air sampling system and to prove its capability to perform an air sampling mission following a specific flight path.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nitrous oxide emissions were monitored at three sites over a 2-year period in irrigated cotton fields in Khorezm, Uzbekistan, a region located in the arid deserts of the Aral Sea Basin. The fields were managed using different fertilizer management strategies and irrigation water regimes. N2O emissions varied widely between years, within 1 year throughout the vegetation season, and between the sites. The amount of irrigation water applied, the amount and type of N fertilizer used, and topsoil temperature had the greatest effect on these emissions. Very high N2O emissions of up to 3000 μg N2O-N m−2 h−1 were measured in periods following N-fertilizer application in combination with irrigation events. These “emission pulses” accounted for 80–95% of the total N2O emissions between April and September and varied from 0.9 to 6.5 kg N2O-N ha−1.. Emission factors (EF), uncorrected for background emission, ranged from 0.4% to 2.6% of total N applied, corresponding to an average EF of 1.48% of applied N fertilizer lost as N2O-N. This is in line with the default global average value of 1.25% of applied N used in calculations of N2O emissions by the Intergovernmental Panel on Climate Change. During the emission pulses, which were triggered by high soil moisture and high availability of mineral N, a clear diurnal pattern of N2O emissions was observed, driven by daily changes in topsoil temperature. For these periods, air sampling from 8:00 to 10:00 and from 18:00 to 20:00 was found to best represent the mean daily N2O flux rates. The wet topsoil conditions caused by irrigation favored the production of N2O from NO3− fertilizers, but not from NH4+ fertilizers, thus indicating that denitrification was the main process causing N2O emissions. It is therefore argued that there is scope for reducing N2O emission from irrigated cotton production; i.e. through the exclusive use of NH4+ fertilizers. Advanced application and irrigation techniques such as subsurface fertilizer application, drip irrigation and fertigation may also minimize N2O emission from this regionally dominant agro-ecosystem.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A nation-wide passive air sampling campaign recorded concentrations of persistent organic pollutants in Australia's atmosphere in 2012. XAD-based passive air samplers were deployed for one year at 15 sampling sites located in remote/background, agricultural and semi-urban and urban areas across the continent. Concentrations of 47 polychlorinated biphenyls ranged from 0.73 to 72 pg m-3 (median of 8.9 pg m-3) and were consistently higher at urban sites. The toxic equivalent concentration for the sum of 12 dioxin-like PCBs was low, ranging from below detection limits to 0.24 fg m-3 (median of 0.0086 fg m-3). Overall, the levels of polychlorinated biphenyls in Australia were among the lowest reported globally to date. Among the organochlorine pesticides, hexachlorobenzene had the highest (median of 41 pg m-3) and most uniform concentration (with a ratio between highest and lowest value [similar]5). Bushfires may be responsible for atmospheric hexachlorobenzene levels in Australia that exceeded Southern Hemispheric baseline levels by a factor of [similar]4. Organochlorine pesticide concentrations generally increased from remote/background and agricultural sites to urban sites, except for high concentrations of [small alpha]-endosulfan and DDTs at specific agricultural sites. Concentrations of heptachlor (0.47-210 pg m-3), dieldrin (ND-160 pg m-3) and trans- and cis-chlordanes (0.83-180 pg m-3, sum of) in Australian air were among the highest reported globally to date, whereas those of DDT and its metabolites (ND-160 pg m-3, sum of), [small alpha]-, [small beta]-, [gamma]- and [small delta]-hexachlorocyclohexane (ND-6.7 pg m-3, sum of) and [small alpha]-endosulfan (ND-27 pg m-3) were among the lowest.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This technical report describes a Light Detection and Ranging (LiDAR) augmented optimal path planning at low level flight methodology for remote sensing and sampling Unmanned Aerial Vehicles (UAV). The UAV is used to perform remote air sampling and data acquisition from a network of sensors on the ground. The data that contains information on the terrain is in the form of a 3D point clouds maps is processed by the algorithms to find an optimal path. The results show that the method and algorithm are able to use the LiDAR data to avoid obstacles when planning a path from a start to a target point. The report compares the performance of the method as the resolution of the LIDAR map is increased and when a Digital Elevation Model (DEM) is included. From a practical point of view, the optimal path plan is loaded and works seemingly with the UAV ground station and also shows the UAV ground station software augmented with more accurate LIDAR data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ENGLISH: This study is based on collections of larvae of Thunnus albacares, Euthynnus llneatus, and Auxis sp. obtained from surface and oblique net tows made during seven cruises, each along a comparable track in the entrance of the Gulf of California and each during a different month. Concomitant measurements of surface temperature, salinity, and zooplankton were made at each of the plankton stations. The catches of larval Auxis sp. were examined by analysis of variance techniques to determine which environmental features were associated with the spawning of this tuna as indicated by the distribution of larvae and to gain some insight into the behavior of the larvae themselves. The testing indicated that the spawning of Auxis sp. varied significantly among the different months of the cruises. The testing also indicated that if the larvae were capable of avoiding the sampling apparatus, this ability was not related to features associated with time of day such as light conditions. The analysis did not detect any change in the vertical distribution of the larvae among the months of the experiment. It was concluded that the larvae did not exhibit a diel vertical movement. The measurements of temperature, salinity, and zooplankton volumes were treated as covariates in the analysis. The surface temperature proved to be a highly important factor in explaining the distribution of larvae, but salinity and zooplankton volumes were not. Catches of Thunnus albaeares and Euthynnus lineatus were rare during the course of the study; these are discussed in qualitative terms with respect to the time of the year and the surface temperature. The distribution of larval tunas in the area of study was compared with the distribution of surface water masses. It appeared that these masses had no influence per se on the distribution of larvae. SPANISH: Este estudio está basado en las recolecciones de larvas de Thunnus albacares, Eutbynnus lineatus, y Auxis sp. obtenidas según los arrastres superficiales y oblicuos de la red, realizados durante siete cruceros, cada uno a la entrada del Golfo de California a lo largo de un derrotero comparable, y cada uno durante distintos meses. Las mediciones correspondientes de la temperatura superficial, salinidad y de zooplancton se realizaron en cada una de las estaciones de plancton. Las capturas de larvas Auxís sp. fueron examinadas mediante el análisis de la varianza para determinar cuales características ambientales se encontraban asociadas con el desove de este atún según lo indicaba la distribución de las larvas, y para obtener alguna idea del comportamiento de las larvas en sí mismas. Las pruebas indicaron que el desove de Auxis sp. varió significativamente entre los diferentes meses de los cruceros; indicaron también que si las larvas eran capaces de evitar el aparato de muestreo, esta habilidad no se relacionaba a las características asociadas con la hora del día de acuerdo a las condiciones de luz. El análisis no demostró ningún cambio en la distribución vertical de las larvas durante los meses del experimento. Se determinó que las larvas no exhiben un movimiento vertical diario. Las mediciones de temperatura, salinidad, y de los volúmenes de zooplancton fueron tratadas como covariables en el análisis. La temperatura superficial demostró ser un factor altamente importante en la explicación de la distribución de las larvas, pero la salinidad y los volúmenes de zooplancton no lo fueron. Las capturas de Thunnus albacares y Eutbynnus lineatus fueron pocas durante el curso de este estudio; éstas se discuten en términos cualitativos respecto a la época del año y a la temperatura superficial. La distribución de los atunes larvales en el área de estudio fue comparada con la distribución de las masas superficiales de agua. Parece que estas masas no tienen influencia per se en la distribución de las larvas. (PDF contains 40 pages.)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The importance of hand hygiene in reducing the spread of pathogens has been long established and this has been highlighted recently in initiatives such as the NHS’s ‘clean your hands’ campaign. However, much of the focus on hand hygiene has concerned effective hand washing; there has been less emphasis on hand drying and its role in hygienic practices. This study aimed to compare three hand drying methods namely paper towels, a warm air dryer and a jet air dryer for their relative ability to disseminate virus particles into the washroom environment during hand drying. A bacteriophage model was used to compare these methods; hands were artificially contaminated with MS2 phage and dried using each device. Both air sampling and contact plates were assessed and a plaque assay was used to quantify virus dissemination. Samples were collected at set times, heights, angles and distances around each device. Both air sampling and contact plate results indicated that the jet air dryer produced significantly more virus dispersal than either paper towels or the warm air dryer in terms of quantity, distance travelled and the time spent circulating in the air around the device and potentially in the washroom environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background World Health Organization hand hygiene guidelines state that if electric hand dryers are used, they should not aerosolize pathogens. Previous studies have investigated the dispersal by different hand-drying devices of chemical indicators, fungi and bacteria on the hands. This study assessed the aerosolization and dispersal of virus on the hands to determine any differences between hand-drying devices in their potential to contaminate other occupants of public washrooms and the washroom environment. Methods A suspension of MS2, an Escherichia coli bacteriophage virus, was used to artificially contaminate the hands of participants prior to using three different handdrying devices: jet air dryer, warm air dryer, paper towel dispenser. Virus was detected by plaque formation on agar plates layered with the host bacterium. Vertical dispersal of virus was assessed at a fixed distance (0.4 m) and over a range of different heights (0.0 – 1.8 m) from the floor. Horizontal dispersal was assessed at different distances of up to three metres from the hand-drying devices. Virus aerosolization and dispersal was also assessed at different times up to 15 minutes after use by means of air sampling at two distances (0.1 and 1.0 m) and at a distance behind and offset from each of the hand-drying devices. Results Over a range of heights, the jet air dryer was shown to produce over 60 times greater vertical dispersal of virus from the hands than a warm air dryer and over 1300 times greater than paper towels; the maximum being detected between 0.6 and 1.2 metres from the floor. Horizontal dispersal of virus by the jet air dryer was over 20 times greater than a warm air dryer and over 190 times greater than paper towels; virus being detected at distances of up to three metres. Air sampling at three different positions from the hand-drying devices 15 minutes after use showed that the jet air dryer produced over 50-times greater viral contamination of the air than a warm air dryer and over 110-times greater than paper towels. Conclusions Due to their high air speed, jet air dryers aerosolize and disperse more virus over a range of heights, greater distances, and for longer times than other hand drying devices. If hands are inadequately washed, they have a greater potential to contaminate other occupants of a public washroom and the washroom environment. Main messages: Jet air dryers with claimed air speeds of over 600 kph have a greater potential than warm air dryers or paper towels to aerosolize and disperse viruses on the hands of users. The choice of hand-drying device should be carefully considered. Jet air dryers may increase the risk of transmission of human viruses, such as norovirus, particularly if hand washing is inadequate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background World Health Organization and EU hand hygiene guidelines state that if electric hand dryers are used, they should not aerosolize pathogens. Previous studies have investigated the dispersal by different hand-drying devices of chemical indicators, fungi and bacteria on the hands. This study assessed the aerosolization and dispersal of virus on the hands to determine any differences between hand-drying devices in their potential to contaminate other occupants of public washrooms and the washroom environment. Methods A suspension of MS2, an Escherichia coli bacteriophage virus, was used to artificially contaminate the hands of participants prior to using three different hand-drying devices: jet air dryer, warm air dryer, paper towel dispenser. Virus was detected by plaque formation on agar plates layered with the host bacterium. Vertical dispersal of virus was assessed at a fixed distance (0.4 m) and over a range of different heights (0.0 – 1.8 m) from the floor. Horizontal dispersal was assessed at different distances of up to three metres from the hand-drying devices. Virus aerosolization and dispersal was also assessed at different times up to 15 minutes after use by means of air sampling at two distances (0.1 and 1.0 m) and at a distance behind and offset from each of the hand-drying devices. Results Over a range of heights, the jet air dryer was shown to produce over 60 times greater vertical dispersal of virus from the hands than a warm air dryer and over 1300 times greater than paper towels; the maximum being detected between 0.6 and 1.2 metres from the floor. Horizontal dispersal of virus by the jet air dryer was over 20 times greater than a warm air dryer and over 190 times greater than paper towels; virus being detected at distances of up to three metres. Air sampling at three different positions from the hand-drying devices 15 minutes after use showed that the jet air dryer produced over 50-times greater viral contamination of the air than a warm air dryer and over 110-times greater than paper towels. Conclusions Due to their high air speed, jet air dryers aerosolize and disperse more virus over a range of heights, greater distances, and for longer times than other hand drying devices. If hands are inadequately washed, they have a greater potential to contaminate other occupants of a public washroom and the washroom environment. Main messages: Jet air dryers with claimed air speeds of over 600 kph have a greater potential than warm air dryers or paper towels to aerosolize and disperse viruses on the hands of users. The choice of hand-drying device should be carefully considered. Jet air dryers may increase the risk of transmission of human viruses, such as norovirus, particularly if hand washing is inadequate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Il est reconnu que le benzène, le toluène, l’éthylbenzène et les isomères du xylène, composés organiques volatils (COVs) communément désignés BTEX, produisent des effets nocifs sur la santé humaine et sur les végétaux dépendamment de la durée et des niveaux d’exposition. Le benzène en particulier est classé cancérogène et une exposition à des concentrations supérieures à 64 g/m3 de benzène peut être fatale en 5–10 minutes. Par conséquent, la mesure en temps réel des BTEX dans l’air ambiant est essentielle pour détecter rapidement un danger associé à leur émission dans l’air et pour estimer les risques potentiels pour les êtres vivants et pour l’environnement. Dans cette thèse, une méthode d’analyse en temps réel des BTEX dans l’air ambiant a été développée et validée. La méthode est basée sur la technique d’échantillonnage direct de l’air couplée avec la spectrométrie de masse en tandem utilisant une source d’ionisation chimique à pression atmosphérique (APCI-MS/MS directe). La validation analytique a démontré la sensibilité (limite de détection LDM 1–2 μg/m3), la précision (coefficient de variation CV < 10%), l’exactitude (exactitude > 95%) et la sélectivité de la méthode. Des échantillons d’air ambiant provenant d’un site d’enfouissement de déchets industriels et de divers garages d’entretien automobile ont été analysés par la méthode développée. La comparaison des résultats avec ceux obtenus par la technique de chromatographie gazeuse on-line couplée avec un détecteur à ionisation de flamme (GC-FID) a donné des résultats similaires. La capacité de la méthode pour l’évaluation rapide des risques potentiels associés à une exposition aux BTEX a été prouvée à travers une étude de terrain avec analyse de risque pour la santé des travailleurs dans trois garages d’entretien automobile et par des expériences sous atmosphères simulées. Les concentrations mesurées dans l’air ambiant des garages étaient de 8,9–25 µg/m3 pour le benzène, 119–1156 µg/m3 pour le toluène, 9–70 µg/m3 pour l’éthylbenzène et 45–347 µg/m3 pour les xylènes. Une dose quotidienne environnementale totale entre 1,46 10-3 et 2,52 10-3 mg/kg/jour a été déterminée pour le benzène. Le risque de cancer lié à l’exposition environnementale totale au benzène estimé pour les travailleurs étudiés se situait entre 1,1 10-5 et 1,8 10-5. Une nouvelle méthode APCI-MS/MS a été également développée et validée pour l’analyse directe de l’octaméthylcyclotétrasiloxane (D4) et le décaméthylcyclopentasiloxane (D5) dans l’air et les biogaz. Le D4 et le D5 sont des siloxanes cycliques volatils largement utilisés comme solvants dans les processus industriels et les produits de consommation à la place des COVs précurseurs d’ozone troposphérique tels que les BTEX. Leur présence ubiquitaire dans les échantillons d’air ambiant, due à l’utilisation massive, suscite un besoin d’études de toxicité. De telles études requièrent des analyses qualitatives et quantitatives de traces de ces composés. Par ailleurs, la présence de traces de ces substances dans un biogaz entrave son utilisation comme source d’énergie renouvelable en causant des dommages coûteux à l’équipement. L’analyse des siloxanes dans un biogaz s’avère donc essentielle pour déterminer si le biogaz nécessite une purification avant son utilisation pour la production d’énergie. La méthode développée dans cette étude possède une bonne sensibilité (LDM 4–6 μg/m3), une bonne précision (CV < 10%), une bonne exactitude (> 93%) et une grande sélectivité. Il a été également démontré qu’en utilisant cette méthode avec l’hexaméthyl-d18-disiloxane comme étalon interne, la détection et la quantification du D4 et du D5 dans des échantillons réels de biogaz peuvent être accomplies avec une meilleure sensibilité (LDM ~ 2 μg/m3), une grande précision (CV < 5%) et une grande exactitude (> 97%). Une variété d’échantillons de biogaz prélevés au site d’enfouissement sanitaire du Complexe Environnemental de Saint-Michel à Montréal a été analysée avec succès par cette nouvelle méthode. Les concentrations mesurées étaient de 131–1275 µg/m3 pour le D4 et 250–6226 µg/m3 pour le D5. Ces résultats représentent les premières données rapportées dans la littérature sur la concentration des siloxanes D4 et D5 dans les biogaz d’enfouissement en fonction de l’âge des déchets.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A nephelometric technique based on a liquid drop is described for the measurement of atmospheric sulfur dioxide. A 40-mul drop of barium chloride and hydrogen peroxide solution is suspended in a flowing-air sampling stream. The sulfur (IV) collected is oxidized to sulfur (VI) and finally precipitated as barium sulfate. Nephelometric detection of drop is achieved by an appropriate arrangement consisting of an optical fiber contacting the drop and a photodiode placed at 90degrees relative to the fiber. The design and characteristics of this drop-based gas sensor system are described. The analytical response, as photocurrent, is proportional to the product of the sampling period and the sulfur dioxide concentration. The detection limit is ca. 1.1 mg m(-3) for a 10-min sampling time. The present technique is fairly rapid and simple, uses a small amount of reagent and is set up with low-cost equipment, making this system economically viable. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A simple and sensitive method based on a liquid droplet is described for the measurement of atmospheric ozone. A 30 μL drop of indigo blue solution is suspended in a flowing-air sampling stream. The ozone collected reacts with the indigo solution resulting in its decolorization. The colorimetric sensor is composed of two optical fibers and the source of monochromatic light was a red LED (625 nm). The calibration curve was constructed with ozone standard concentrations ranging from 37 - 123 ppbv. The detection limit achieved was 7.3 ppbv. The method considered here showed itself to be easy to apply with a fast response and a total analysis time of only 5 minutes.