606 resultados para Acero inoxidable


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias de la Ingeniería Mecánica con Especialidad en Materiales) U.A.N.L. Facultad de Ingeniería Mecánica y Eléctrica, 1996

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis ( Maestro en Ciencias de la Ingeniería Mecánica con Especialidad en Materiales ) U.A.N.L.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias de la Ingeniería Mecánica con Especialidad en Materiales) U.A.N.L.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[Tesis] ( Maestría en Ciencias con Orientación a Ingeniería Cerámica ) U.A.N.L.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias de la Ingeniería Mecánica con Especialidad en Materiales) U.A.N.L.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El proyecto se realiza en el Departamento de Química Analítica de la E.U.P. de Valladolid por tres profesores del mismo. El objetivo es el diseño de experimentos que permiten estudiar el fenómeno de la corrosión en metales. Los fenómenos de corrosión se producen de forma muy lenta, pero el proceso se acelera sis e aplica un potencial eléctrico controlado, lo que posibilita obtener datos y conclusiones en el breve período de una sesión de prácticas. Para ello, se ha utilizado un potenciostato-galvanostato y un generador de funciones conectados, mediante la tarjeta de comunicación adecuada, a un ordenador. Para el desarrollo del trabajo se han ensayado distintos metales y aleaciones, de los cuales se han elegido para las dos prácticas propuestas: acero inoxidable y aluminio. Con acero inoxidable se han realizado estudios de polarización anódica en medio ácido (H2SO4), medio agresivo (NaCl) y medio inhibidor (NaNO3). Con el aluminio se han llevado a cabo estudios de la capacidad inhibidora frente a su corrosión con seis sustancias distintas. Así mismo, se ha desarrollado un sistema de adquisición de datos, que permite el tratamiento de los mismos mediante un equipo informático, que ha dado lugar a un Proyecto Fin de Carrera de un alumno de esta Escuela. Como resultados, además del Proyecto Fin de Carrera indicado, se han diseñado dos prácticas de laboratorio que favorecerán el aprendizaje de los alumnos en un tema, la corrosión metálica, que es un aspecto importante de su formación. Como materiales elaborados, además del Proyecto Fin de Carrera disponible para consulta en la biblioteca del Centro, se han realizado los guiones de dos prácticas tituladas: 'Corrosión del acero en medio acuosos' e 'Inhibidores de corrosión para el aluminio', que serán utilizados por los alumnos en el laboratorio, y que si bien no han sido publicados, se entregan para su realización.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Los costos de las barricas, por el tipo de cambio en la Argentina, son inaccesibles para muchas bodegas. Debido a esto, muchas de ellas utilizan sistemas alternativos de crianza, no conociendo claramente las consecuencias y los fenómenos que ocurren con el uso de estos sistemas. El objetivo del trabajo fue evaluar la composición polifenólica, el color y los caracteres sensoriales de vinos tratados con distintos sistemas de crianza en madera. Para ello se utilizaron métodos espectofotométricos rápidos y fácilmente realizables en bodega. Los tra tamientos a los cuales se sometió el vino fueron: barrica de roble americano de primer uso, barrica de más de cinco años de uso reacondicionada, vasija de acero inoxidable con “dominó" de roble en dosis comúnmente usadas en el medio, vasija de acero inoxidable con “dominó" de roble en dosis equivalentes a la superficie de contacto de la barrica y vino sin madera tomado como testigo. El ensayo se realizó con vinos cosecha 2007 de las variedades Malbec y Cabernet Sauvignon y el tiempo de crianza fue de 10 meses. Los resultados mostraron que en ninguna de las variedades los tratamientos con barricas obtuvieron mayor nivel de polimerización que el resto de los tratamientos ni tampoco los sistemas con agregado de fragmentos de roble superaron en polimerización al vino sin madera. Por otro lado, sólo en la variedad Cabernet Sauvignon la barrica nueva superó en intensidad de color al vino sin madera. En cambio, los tratamientos con roble favorecieron la copigmentación y los copigmentos inhibieron la polimerización, haciendo más lenta la formación de uniones tanino- antocianos pero también protegiendo el color y evitando oxidaciones, esta situación podría explicar los resultados contradictorios entre distintos autores. En el aspecto sensorial los vinos en barricas no obtuvieron mayor intensidad de color ni menor astringencia que los vinos con agregado de roble y tampoco estos últimos lograron diferencias con el vino testigo. Por otro lado en ambas variedades, la barrica nueva y el tratamiento con alta dosis de dominó de roble tuvieron la mayor intensidad aromática con descriptores como vainilla y chocolate aunque la alternativa de crianza con “dominó" estuvo muy ligada al descriptor “tabla". La barrica reacondicionada mostró el mayor nivel del descriptor betún y en el tratamiento testigo se detectaron aromas de reducción. El tratamiento con dominó de roble en dosis comerciales se encontró más ligado a los aromas frutados.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En las décadas de 1930, 1940 y 1950 se utilizó con cierta profusión en las fachadas españolas la solución de molduras horizontales resueltas con elementos huecos prefabricados de piedra artificial. Con el paso del tiempo, dichas molduras han sufrido procesos de desprendimiento debido a la entrada de agua por el tablero superior, con la consiguiente corrosión y rotura de los alambres de anclaje, por lo que requieren una reparación. Se describe un caso de rehabilitación mediante reanclado desde el exterior de las diferentes molduras de una fachada de un edificio singular en Madrid, con varillas roscadas de acero inoxidable y resina epoxi de adherencia, así como la introducción de juntas de dilatación con el objeto de reducir las variaciones dimensionales del conjunto.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La utilización de armaduras de acero inoxidable, de los tipos austeníticos y dúplex, con el objetivo de prolongar la vida útil de las estructuras de hormigón, es una alternativa que está recibiendo cada vez más consideración. Los aceros inoxidables son aleaciones fundamentalmente de cromo y níquel, con muy alta resistencia a la corrosión, especialmente por cloruros. El elevado coste del níquel y sus grandes fluctuaciones en el mercado, han favorecido la aparición de nuevos aceros inoxidables con bajo contenido en dicha aleación y, por lo tanto, más económicos, que sin embargo presentan una resistencia a la corrosión similar a los tradicionales. En este trabajo se ha evaluado la resistencia a la corrosión por cloruros de dos nuevos aceros inoxidables de bajo contenido en níquel. Uno de los aceros es austenítico, de producción en forma de chapa, y el otro dúplex, que se comercializa como barra corrugada. La resistencia a la corrosión se ha evaluado, respectivamente, mediante ensayos electroquímicos de dichos aceros embebidos en solución simulada de poros de hormigón y en probetas de mortero contaminados con diferentes cuantías de cloruros. Los resultados de los ensayos se han comparado con los del acero austenítico tradicional AISI 304 y del acero al carbono B500SD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present investigation addresses the overall and local mechanical performance of dissimilar joints of low carbon steel (CS) and stainless steel (SS) thin sheets achieved by laser welding in case of heat source displacement from the weld gap centreline towards CS. Microstructure characterization and residua! strain scanning, carried out by neutron diffraction, were used to assess the joints features. It was found that the heat source position influences the base metals dilution and the residua! stress field associated to the welding process; the transverse residual stress is smaller than for the longitudinal component, of magnitudes close to the parent CS yield strength. Furthermore, compressive transverse residual stresses were encountered at the SS-weld interface. The tensile behavior of the joint different zones assessed by using a video-image based system (VIC-2D) reveals that the residual stress field, together with the positive difference in yield between the weld metal and the base materials protects the joint from being piastically deformed. The tensile loadings of flat transverse specimens generate the strain localization and failure in CS, far away from the weld.En este trabajo se exponen los resultados de una investigacion sobre el comportamiento mecanico de soldaduras disimiles acero inoxidable-acero al carbono, realizadas para unir chapas delgadas, desplazando la fuente de calor del eje longitudinal de la union soldada por laser sobre el acero al carbono. Se han determinado las caracteristicas microestructurales de la union soldada, las tensiones residuales generadas (mediante difraccion de neutrones) y las curvas tension-deformacion locales y globales, mediante medidas locales de deformacion empleando el sistema VIC-2D "video image correlation". El desplazamiento de la fuente de calor infiuye en la dilution de los metales base y el campo de tensiones residuales asociado al proceso de soldeo; las tensiones residuales medidas en direction longitudinal se aproximan al limite elastico del acero al carbono, mientras que las tensiones residuales transversales son menores, e incluso de compresion. El ensayo a traccion de la union soldada revela que las tensiones residuales y la diferencia de limite elastico entre los metales base y la soldadura propician que la rotura se produzca por inestabilidad plastica del acero al carbono, lejos de la soldadura, sin que la union plastifique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Un caloducto en bucle cerrado o Loop Heat Pipe (LHP) es un dispositivo de transferencia de calor cuyo principio de operación se basa en la evaporación/condensación de un fluido de trabajo, que es bombeado a través de un circuito cerrado gracias a fuerzas de capilaridad. Gracias a su flexibilidad, su baja masa y su mínimo (incluso nulo) consumo de potencia, su principal aplicación ha sido identificada como parte del subsistema de control térmico de vehículos espaciales. En el presente trabajo se ha desarrollado un LHP capaz de funcionar eficientemente a temperaturas de hasta 125 oC, siguiendo la actual tendencia de los equipos a bordo de satélites de incrementar su temperatura de operación. En la selección del diseño optimo para dicho LHP, la compatibilidad entre materiales y fluido de trabajo se identificó como uno de los puntos clave. Para seleccionar la mejor combinación, se llevó a cabo una exhaustiva revisión del estado del arte, además de un estudio especifico que incluía el desarrollo de un banco de ensayos de compatibilidad. Como conclusión, la combinación seleccionada como la candidata idónea para ser integrada en el LHP capaz de operar hasta 125 oC fue un evaporador de acero inoxidable, líneas de titanio y amoniaco como fluido de trabajo. En esa línea se diseñó y fabricó un prototipo para ensayos y se desarrolló un modelo de simulación con EcosimPro para evaluar sus prestaciones. Se concluyó que el diseño era adecuado para el rango de operación definido. La incompatibilidad entre el fluido de trabajo y los materiales del LHP está ligada a la generación de gases no condensables. Para un estudio más detallado de los efectos de dichos gases en el funcionamiento del LHP se analizó su comportamiento con diferentes cantidades de nitrógeno inyectadas en su cámara de compensación, simulando un gas no condensable formado en el interior del dispositivo. El estudio se basó en el análisis de las temperaturas medidas experimentalmente a distintos niveles de potencia y temperatura de sumidero o fuente fría. Adicionalmente, dichos resultados se compararon con las predicciones obtenidas por medio del modelo en EcosimPro. Las principales conclusiones obtenidas fueron dos. La primera indica que una cantidad de gas no condensable más de dos veces mayor que la cantidad generada al final de la vida de un satélite típico de telecomunicaciones (15 años) tiene efectos casi despreciables en el funcionamiento del LHP. La segunda es que el principal efecto del gas no condensable es una disminución de la conductancia térmica, especialmente a bajas potencias y temperaturas de sumidero. El efecto es más significativo cuanto mayor es la cantidad de gas añadida. Asimismo, durante la campaña de ensayos se observó un fenómeno no esperado para grandes cantidades de gas no condensable. Dicho fenómeno consiste en un comportamiento oscilatorio, detectado tanto en los ensayos como en la simulación. Este efecto es susceptible de una investigación más profunda y los resultados obtenidos pueden constituir la base para dicha tarea. ABSTRACT Loop Heat Pipes (LHPs) are heat transfer devices whose operating principle is based on the evaporation/condensation of a working fluid, and which use capillary pumping forces to ensure the fluid circulation. Thanks to their flexibility, low mass and minimum (even null) power consumption, their main application has been identified as part of the thermal control subsystem in spacecraft. In the present work, an LHP able to operate efficiently up to 125 oC has been developed, which is in line with the current tendency of satellite on-board equipment to increase their operating temperatures. In selecting the optimal LHP design for the elevated temperature application, the compatibility between the materials and working fluid has been identified as one of the main drivers. An extensive literature review and a dedicated trade-off were performed, in order to select the optimal combination of fluids and materials for the LHP. The trade-off included the development of a dedicated compatibility test stand. In conclusion, the combination of stainless steel evaporator, titanium piping and ammonia as working fluid was selected as the best candidate to operate up to 125 oC. An LHP prototype was designed and manufactured and a simulation model in EcosimPro was developed to evaluate its performance. The first conclusion was that the defined LHP was suitable for the defined operational range. Incompatibility between the working fluid and LHP materials is linked to Non Condensable Gas (NCG) generation. Therefore, the behaviour of the LHP developed with different amounts of nitrogen injected in its compensation chamber to simulate NCG generation, was analyzed. The LHP performance was studied by analysis of the test results at different temperatures and power levels. The test results were also compared to simulations in EcosimPro. Two additional conclusions can be drawn: (i) the effects of an amount of more than two times the expected NCG at the end of life of a typical telecommunications satellite (15 years) is almost negligible on the LHP operation, and (ii) the main effect of the NCG is a decrease in the LHP thermal conductance, especially at low temperatures and low power levels. This decrease is more significant with the progressive addition of NCG. An unexpected phenomenon was observed in the LHP operation with large NCG amounts. Namely, an oscillatory behaviour, which was observed both in the tests and the simulation. This effect provides the basis for further studies concerning oscillations in LHPs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Existe una creciente necesidad de hacer el mejor uso del agua para regadío. Una alternativa eficiente consiste en la monitorización del contenido volumétrico de agua (θ), utilizando sensores de humedad. A pesar de existir una gran diversidad de sensores y tecnologías disponibles, actualmente ninguna de ellas permite obtener medidas distribuidas en perfiles verticales de un metro y en escalas laterales de 0.1-1,000 m. En este sentido, es necesario buscar tecnologías alternativas que sirvan de puente entre las medidas puntuales y las escalas intermedias. Esta tesis doctoral se basa en el uso de Fibra Óptica (FO) con sistema de medida de temperatura distribuida (DTS), una tecnología alternativa de reciente creación que ha levantado gran expectación en las últimas dos décadas. Específicamente utilizamos el método de fibra calentada, en inglés Actively Heated Fiber Optic (AHFO), en la cual los cables de Fibra Óptica se utilizan como sondas de calor mediante la aplicación de corriente eléctrica a través de la camisa de acero inoxidable, o de un conductor eléctrico simétricamente posicionado, envuelto, alrededor del haz de fibra óptica. El uso de fibra calentada se basa en la utilización de la teoría de los pulsos de calor, en inglés Heated Pulsed Theory (HPP), por la cual el conductor se aproxima a una fuente de calor lineal e infinitesimal que introduce calor en el suelo. Mediante el análisis del tiempo de ocurrencia y magnitud de la respuesta térmica ante un pulso de calor, es posible estimar algunas propiedades específicas del suelo, tales como el contenido de humedad, calor específico (C) y conductividad térmica. Estos parámetros pueden ser estimados utilizando un sensor de temperatura adyacente a la sonda de calor [método simple, en inglés single heated pulsed probes (SHPP)], ó a una distancia radial r [método doble, en inglés dual heated pulsed probes (DHPP)]. Esta tesis doctoral pretende probar la idoneidad de los sistemas de fibra óptica calentada para la aplicación de la teoría clásica de sondas calentadas. Para ello, se desarrollarán dos sistemas FO-DTS. El primero se sitúa en un campo agrícola de La Nava de Arévalo (Ávila, España), en el cual se aplica la teoría SHPP para estimar θ. El segundo sistema se desarrolla en laboratorio y emplea la teoría DHPP para medir tanto θ como C. La teoría SHPP puede ser implementada con fibra óptica calentada para obtener medidas distribuidas de θ, mediante la utilización de sistemas FO-DTS y el uso de curvas de calibración específicas para cada suelo. Sin embargo, la mayoría de aplicaciones AHFO se han desarrollado exclusivamente en laboratorio utilizando medios porosos homogéneos. En esta tesis se utiliza el programa Hydrus 2D/3D para definir tales curvas de calibración. El modelo propuesto es validado en un segmento de cable enterrado en una instalación de fibra óptica y es capaz de predecir la respuesta térmica del suelo en puntos concretos de la instalación una vez que las propiedades físicas y térmicas de éste son definidas. La exactitud de la metodología para predecir θ frente a medidas puntuales tomadas con sensores de humedad comerciales fue de 0.001 a 0.022 m3 m-3 La implementación de la teoría DHPP con AHFO para medir C y θ suponen una oportunidad sin precedentes para aplicaciones medioambientales. En esta tesis se emplean diferentes combinaciones de cables y fuentes emisoras de calor, que se colocan en paralelo y utilizan un rango variado de espaciamientos, todo ello en el laboratorio. La amplitud de la señal y el tiempo de llegada se han observado como funciones del calor específico del suelo. Medidas de C, utilizando esta metodología y ante un rango variado de contenidos de humedad, sugirieron la idoneidad del método, aunque también se observaron importantes errores en contenidos bajos de humedad de hasta un 22%. La mejora del método requerirá otros modelos más precisos que tengan en cuenta el diámetro del cable, así como la posible influencia térmica del mismo. ABSTRACT There is an increasing need to make the most efficient use of water for irrigation. A good approach to make irrigation as efficient as possible is to monitor soil water content (θ) using soil moisture sensors. Although, there is a broad range of different sensors and technologies, currently, none of them can practically and accurately provide vertical and lateral moisture profiles spanning 0-1 m depth and 0.1-1,000 m lateral scales. In this regard, further research to fulfill the intermediate scale and to bridge single-point measurement with the broaden scales is still needed. This dissertation is based on the use of Fiber Optics with Distributed Temperature Sensing (FO-DTS), a novel approach which has been receiving growing interest in the last two decades. Specifically, we employ the so called Actively Heated Fiber Optic (AHFO) method, in which FO cables are employed as heat probe conductors by applying electricity to the stainless steel armoring jacket or an added conductor symmetrically positioned (wrapped) about the FO cable. AHFO is based on the classic Heated Pulsed Theory (HPP) which usually employs a heat probe conductor that approximates to an infinite line heat source which injects heat into the soil. Observation of the timing and magnitude of the thermal response to the energy input provide enough information to derive certain specific soil thermal characteristics such as the soil heat capacity, soil thermal conductivity or soil water content. These parameters can be estimated by capturing the soil thermal response (using a thermal sensor) adjacent to the heat source (the heating and the thermal sources are mounted together in the so called single heated pulsed probe (SHPP)), or separated at a certain distance, r (dual heated pulsed method (DHPP) This dissertation aims to test the feasibility of heated fiber optics to implement the HPP theory. Specifically, we focus on measuring soil water content (θ) and soil heat capacity (C) by employing two types of FO-DTS systems. The first one is located in an agricultural field in La Nava de Arévalo (Ávila, Spain) and employ the SHPP theory to estimate θ. The second one is developed in the laboratory using the procedures described in the DHPP theory, and focuses on estimating both C and θ. The SHPP theory can be implemented with actively heated fiber optics (AHFO) to obtain distributed measurements of soil water content (θ) by using reported soil thermal responses in Distributed Temperature Sensing (DTS) and with a soil-specific calibration relationship. However, most reported AHFO applications have been calibrated under laboratory homogeneous soil conditions, while inexpensive efficient calibration procedures useful in heterogeneous soils are lacking. In this PhD thesis, we employ the Hydrus 2D/3D code to define these soil-specific calibration curves. The model is then validated at a selected FO transect of the DTS installation. The model was able to predict the soil thermal response at specific locations of the fiber optic cable once the surrounding soil hydraulic and thermal properties were known. Results using electromagnetic moisture sensors at the same specific locations demonstrate the feasibility of the model to detect θ within an accuracy of 0.001 to 0.022 m3 m-3. Implementation of the Dual Heated Pulsed Probe (DPHP) theory for measurement of volumetric heat capacity (C) and water content (θ) with Distributed Temperature Sensing (DTS) heated fiber optic (FO) systems presents an unprecedented opportunity for environmental monitoring. We test the method using different combinations of FO cables and heat sources at a range of spacings in a laboratory setting. The amplitude and phase-shift in the heat signal with distance was found to be a function of the soil volumetric heat capacity (referred, here, to as Cs). Estimations of Cs at a range of θ suggest feasibility via responsiveness to the changes in θ (we observed a linear relationship in all FO combinations), though observed bias with decreasing soil water contents (up to 22%) was also reported. Optimization will require further models to account for the finite radius and thermal influence of the FO cables, employed here as “needle probes”. Also, consideration of the range of soil conditions and cable spacing and jacket configurations, suggested here to be valuable subjects of further study and development.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Se ha estudiado el acero inoxidable pulvimetalúrgico AISI 430L, comparando la sinterización en dos atmósferas diferentes; en vacío, y en una atmósfera que contiene nitrógeno. Se ha desarrollado un tratamiento térmico con objeto de incrementar las propiedades mecánicas, mediante la modificación microestructural de los nitruros complejos de hierro y cromo precipitados durante la etapa de sinterización. Se han evaluado las propiedades físicas y a la vez se ha realizado un análisis microestructural con el fin de relacionar la microestructura con el incremento en las propiedades mecánicas. Influence of sintering atmosphere on the mechanical properties of steel P / M AISI 430L. It has studied the stainless steel powder metallurgy AISI 430L. It has compared the sintering in two different atmospheres; in vacuum, and in an atmosphere containing nitrogen. It has developed a heat treatment with the aim of improving the mechanical properties. This has been done through microstructural modification of complex nitrides of iron and chromium precipitates during the phase of sintering. Physical properties have been evaluated and are been performing a microstructural analysis for microstructure related to the increase in mechanical properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En estudios previos desarrollados en la central Nuclear de cofrentes (Valencia) se ha observado que los microorganismos presentes en las aguas radiactivas de las piscinas de almacenamiento de combustible nuclear gastado son capaces de colonizar las superficies metálicas de las paredes y conducciones y formar biopelículas sobre éstas. Estas biopelículas retienen los radionúclidos de las aguas contributyendo a su descontaminación. En este proyecto se ha diseñado una planta piloto para la biodescontaminación de las aguas radiactivas. Actualmente el agua radiactiva procedente de las piscinas de combustible se hace pasar por resinas de intercambio iónico que posteriormente tienen que ser gestionadas como residuos radiactivos. En este proyecto, el agua se hace pasar por un biorreactor que contiene ovillos de acero inoxidable capaces de ser colonizados por los microorganismos existentes en dichas aguas. A su paso por el biorreactor, el agua entra en contacto con el material del ovillo, formándose una biopelícula que retiene los radioisótopos presentes en el agua. La biopelícula es fácilmente eliminada por cualquier procedimiento convencional de descontaminación radioquímica de materiales y los radionúclidos se pueden concentrar en un volumen pequeño de eluyente para su recuperación, disposición final o contención. A continuación, el material del biorreactor puede ser gestionado como material no radiactivo.