949 resultados para Accelerated Solvent Extraction (ASE-200)
Resumo:
The extraction of Am3+ and Eu3+ from picric acid aqueous solution by N,N-1,2-ethanediyl-bis[2-(N,N-diphenyl-carbamoyl-methoxy)-benzamide] was investigated by a radioactive tracer technique. The composition of the extracted species has been determined as ML(Pic)(3) (M = Eu, Am). The effect of various parameters such as pH, organic diluents, different extractants, picric acid concentration and extractants concentration on the extraction of Am3+ and Eu3+ has been studied. The extraction equilibrium mechanism has been also evaluated and discussed.
Resumo:
The extraction of rare earth elements from chloride medium by mixtures of sec-nonylphenoxy acetic acid (CA100) with bis(2,4,4-trimethylpentyl) dithiophosphinic acid (Cyanex301) or bis(2,4,4-trimethylpentyl) monothiophosphinic acid (Cyanex302) in n-heptane has been studied. The synergistic enhancement of the extraction of lanthanum (III) by mixtures of CA100 with Cyanex301 has been investigated using the methods of slope analysis and constant mole. The extracted complex of lanthanum (III) is determined. The logarithm of the equilibrium constant is calculated as - 1.41. The formation constants and the thermodynamic functions, Delta H, Delta G, and Delta S have also been determined.
Resumo:
The extraction of rare earth elements from chloride medium by mixtures of sec-nonylphenoxy acetic acid (CA100) with bis(2,4,4-trimethylpentyl) dithiophosphinic acid (Cyanex301) or bis(2,4,4-trimethylpentyl) monothiophosphinic acid (Cyanex302) in n-heptane has been studied. The synergistic enhancement of the extraction of lanthanum (III) by mixtures of CA100 with Cyanex301 has been investigated using the methods of slope analysis and constant mole. The extracted complex of lanthanum (III) is determined. The logarithm of the equilibrium constant is calculated as - 1.41. The formation constants and the thermodynamic functions, Delta H, Delta G, and Delta S have also been determined.
Resumo:
Mesoporous YF3 nanoflowers were successfully prepared via solvent extraction route. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) observations indicated that these nanoflowers with uneven porous architectures had a spherical shape and were consisted of many YF3 nanosheets with a thickness of about 15 not. Energy-dispersive spectroscopy (EDS) analysis was used to check the chemical composition and purity of the products. YF3 nanoflowers had bimodal mesoporous distribution and Brunauer-Emmett-Teller (BET) surface area of 116 m(2)/g.
Resumo:
NdF3 and TbF3 nanoparticles were successfully synthesized via a solvent extraction route using Cynex923 (R3P=O). X-ray diffraction (XRD) study showed that pure hexagonal phase NdF3 and pure orthorhombic phase TbF3 could be obtained under the current synthetic conditions. Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) observations indicated that as-obtained NdF3 nanoplates have a diameter of 50-80 nm and thickness of 10-20 nm and TbF3 products have sphere morphologies with diameter from 70 to 170 nm. The driving force for the growth of NdF3 nanoplates could be attributed to the hexagonal crystal structure. The luminescence properties of NdF3 and TbF3 nanoparticles were investigated, which indicated that NdF3 nanoparticles showed typical emission at 888,1064, and 1328 nm and TbF3 nanoparticles showed characteristic emission of Tb3+ (f-f).
Resumo:
The extraction behavior of lanthanides and yttrium usinsg CYANEX 925 (mixture of branched chain alkylated phosphine oxides) in n-heptane from nitrate medium has been studied. The effects of aqueous phase ionic strength, CYANEX 925 concentration in the organic phase, and temperature on Sm3+, Nd3+ and Y3+ extraction have been investigated. The extractability of the lanthanides and yttrium increases with increasing nitrate concentration, as well as with increasing CYANEX 925 concentration. An extraction mechanism is proposed based on slope analysis. Furthermore, the infra-red spectra of CYANEX 925 saturated with lanthanides are employed to provide evidence of the composition of the complex. The relationship between the logarithm of the distribution ratio and lanthanide atomic number is also discussed which indicates that yttrium can be separated from fight lanthanides. In addition separation of the light and heavy lanthanide groups is also possible using CYANEX 925. From the temperature dependence data, the thermodynamic parameters values (Delta H, Delta S and Delta G) are calculated.
Resumo:
The extractions of the selected rare earths (Sc, Y, La and Gd) from hydrochloric acid solutions have been investigated using bis(2,4,4-trimethylpentyl)-mono thiophosphinic acid (Cyanex 302, HL) in heptane as an extractant. The results demonstrate that the extractions of rare earths occur via the following reaction: Sc(OH)(2+) + 2[(HL)(2)]((O)) double left right arrow [Sc(OH)L-2 (.) 2(HL)]((O)) + 2H(+) Y3+ + 3[(HL)(2)]((O)) double left right arrow [Y(HL2)(3)]((O)) + 3H(+) La(OH)(2)(+) + 3[(HL)(2)](O) double left right arrow [La(OH)(2)L (.) 5(HL)]((O)) + H+ Gd(OH)(2+) + 3[(HL)(2)]((O)) double left right arrow [Gd(OH)L-2 (.) 4(HL)]((O)) + 2H(+) The pH(1/2) values and equilibrium constants of the extracted complexes have been deduced by taking into account the aqueous phase complexation of the metal ion with hydroxyl ligands and plausible complexes extracted into the organic phase. According to the pH(1/2) values, it is possible to realize mutual separation among Sc(III), Y(III), La(III) and Gd(III) with Cyanex 302 by controlling aqueous acidity.
Resumo:
In this paper, a new process is proposed to recover rare earths from nitric acid leaching of apatite without interfering with the normal route for fertilizer production using solvent extraction with dimethyl heptyl methyl phosphonate CH3P(O)(OC8H17)(2) (P-350, B). In the present work, the leaching conditions are studied. In selected condition, apatite was dissolved in 20% (v/v) nitric acid solution at 60-70 degrees C while agitating. The most suitable acidity for extraction is 0.4 M HNO3. More than 98% of rare earths in apatite can be recovered using countercurrent extraction process with six stages when phase ratio = 0.5, and defluorination is unnecessary. The influences of phase ratio, stage number, acidity and salting-out agent on extractabilities Of P-350 are studied. The results show that rare earths can be separated with P-350 from Ca, P, Fe and other impurities. Mixed rare earth oxides (REO) of which purity is more than 95% with yield over 98% can be obtained.
Resumo:
Such physicochemical properties of sec-nonylphenoxy acetic acid (CA-100) as the solubility in water, acid dissociation constant in water, dimerization constant in heptane, and distribution constant in organic solvent-water were measured by two-phase titration. The extraction behaviors of scandium (III), yttrium (III), lanthanides (III), and divalent metal ions from hydrochloric acid solutions with CA-100 in heptane have been investigated, and the possibilities of separating scandium (yttrium) from lanthanides and divalent metal ions have been carefully discussed. The stoichiometries of the extracted metal complexes were investigated by the slope-analysis technique. The effect of the nature of diluent on the extraction of yttrium (III) with CA100 has been studied and correlated with the dielectric constant.
Resumo:
A novel method for the highly sensitive determination of perchlorate was proposed. It was based on solvent extraction in the presence of Ru(bpy)(3)(2+) followed by Ru(bpy)(3)(2+) electrochemiluminescent determination. A linear calibration was obtained over the range of 0.1 to 10 mu mol l(-1) with a correlation coefficient of 0.998. The detection limit (S/N = 3) was 5.0 x 10(-8) mol l(-1). The relative standard deviation for 10 replicates of 1 mu mol l(-1) perchlorate was 1.6%. Interference studies suggest that this method is selective for the determination of perchlorate. Application of this method to the highly sensitive determination of other anions is suggested. (C) 1999 Elsevier Science S.A. All rights reserved.
Resumo:
The extraction equilibria of Sc(III), Zr(IV), Ti(IV), Th(IV), Fe(III) and Lu(III) from sulphuric or hydrochloric acid media by Cyanex 923 (mixture of straight chain alkylated phosphine oxides) and Cyanex 925 (mixture of branched chain alkylated phosphine oxides) were studied at various aqueous acidities. The extractant Cyanex 923 demonstrated better scandium loading and selectivity for TI(IV). Fe(III) and Lu(III) than Cyanex 925. The effects of extractant concentration on the extractions of sulphuric acid and Sc(III) by Cyanex 923 were examined. The stoichiometries of the extraction reactions were postulated based on slope analysis. The experimental results indicate that Cyanex 923 can be employed to recover scandium directly from the hydrolytic mother solution arising from TiO2 production via the sulphate process. The parameters studied were scandium loading capacity, phase ratio, concentrations of Ti(IV) scrubbing and Sc(III) stripping agents. A new solvent extraction technology of scandium recovery was developed. The purity of the final Sc(III) product is above 95% with a yield > 94%. (C) 1998 Elsevier Science B.V.
Resumo:
The solvent extraction of Sc(III), Zr(IV), Th(IV), Fe(III) and Lu(III) with Cyanex 302 (bis(2,4,4-trimethylpentyl)monothiophosphinic acid) and Cyanex 301 ( bis(2,4,4-trimethylpentyl) dithiophosphinic acid) in n-hexane from acidic aqueous solutions has been investigated systematically. The effect of equilibrium aqueous acidity on the extraction with these reagents was studied. The separation of Th(IV), Fe(III) and Lu(III) from Sc(III), or the separation of other metals from Lu(III) with Cyanex 302, can be achieved by controlling the aqueous acidity. However, Cyanex 301 exhibited a poor selectivity for the above metals, except for Lu(III). The extraction of these metals with Cyanex 272, Cyanex 302 and Cyanex 301 has been compared. The stripping percentages of Sc(III) for Cyanex 302 and Cyanex 301 in a single stage are near 78% and 75% with 3.5 mol/L and 5.8 mol/L sulphuric acid solutions, respectively. The effects of extractant concentration and temperature on the extraction of Sc(III) were investigated. The stoichiometry of the extraction of Sc(III) with Cyanex 302 was determined. The role of different components of Cyanex 302 in the extraction of Sc(III) was discussed.
Resumo:
The differences between the solvent extraction of Tb(III) and Tb(IV) periodate complexes with quaternary amine were studied carefully for the first time. The effects of extractant concentration, phase ratio, the pH value of stock solution, salting-out agent, extractant form, diluent, and extraction time were comprehensively investigated. Under optimal conditions the separation factor between Tb(IV) and Tb(III) periodate complexes is over 5.5.
Resumo:
An expert system for solvent extraction of rare earths has been developed using LISP. The goal of this project was to mimic the chemists' inferential abilities to assist in the process of solvent extraction of rare earths. The system includes frequently used extractants, separation of specific rare earths, recommendation of procedures for the separation of mixtures of rare earths using (2-ethylhexyl)phosphonic acid 2-ethylhexyl monoester, selection of parameters for counter-current extraction and methods for evaluation of the technique, and the economics of the processing. The expert system runs on an IBM-PC/XT.
Resumo:
An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 µg g-1. Recovery experiments for the global procedure, at the 0.500 µg g-1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection.