920 resultados para Above-Threshold Ionization


Relevância:

80.00% 80.00%

Publicador:

Resumo:

To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrastdiscrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3 c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224--1243.] was `lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To decouple interocular suppression and binocular summation we varied the relative phase of mask and target in a 2IFC contrast-masking paradigm. In Experiment I, dichoptic mask gratings had the same orientation and spatial frequency as the target. For in-phase masking, suppression was strong (a log-log slope of ∼1) and there was weak facilitation at low mask contrasts. Anti-phase masking was weaker (a log-log slope of ∼0.7) and there was no facilitation. A two-stage model of contrast gain control [Meese, T.S., Georgeson, M.A. and Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision, 6: 1224-1243] provided a good fit to the in-phase results and fixed its free parameters. It made successful predictions (with no free parameters) for the anti-phase results when (A) interocular suppression was phase-indifferent but (B) binocular summation was phase sensitive. Experiments II and III showed that interocular suppression comprised two components: (i) a tuned effect with an orientation bandwidth of ∼±33° and a spatial frequency bandwidth of >3 octaves, and (ii) an untuned effect that elevated threshold by a factor of between 2 and 4. Operationally, binocular summation was more tightly tuned, having an orientation bandwidth of ∼±8°, and a spatial frequency bandwidth of ∼0.5 octaves. Our results replicate the unusual shapes of the in-phase dichoptic tuning functions reported by Legge [Legge, G.E. (1979). Spatial frequency masking in human vision: Binocular interactions. Journal of the Optical Society of America, 69: 838-847]. These can now be seen as the envelope of the direct effects from interocular suppression and the indirect effect from binocular summation, which contaminates the signal channel with a mask that has been suppressed by the target. © 2007 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Using a new optical configuration free from the influence of photorefractive optical nonlinearity, we investigate the main characteristics of the spatial subharmonic K/2 excited in a Bi12SiO20 crystal by a light-intensity pattern with wave vector K and frequency O. It is shown that in a large region of intensity and applied electric field the optimum value O of the frequency corresponds to the conditions of parametric excitation of the weakly damped eigenmodes of the medium: the space-charge waves. The threshold and above-threshold characteristics of the subharmonic regime are in good agreement with the theory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It is very well known that contrast detection thresholds improve with the size of a grating-type stimulus, but it is thought that the benefit of size is abolished for contrast discriminations well above threshold (e.g., Legge, G. E., & Foley, J. M. (1980)]. Here we challenge the generality of this view. We performed contrast detection and contrast discrimination for circular patches of sine wave grating as a function of stimulus size. We confirm that sensitivity improves with approximately the fourth-root of stimulus area at detection threshold (a log-log slope of -0.25) but find individual differences (IDs) for the suprathreshold discrimination task. For several observers, performance was largely unaffected by area, but for others performance first improved (by as much as a log-log slope of -0.5) and then reached a plateau. We replicated these different results several times on the same observers. All of these results were described in the context of a recent gain control model of area summation [Meese, T. S. (2004)], extended to accommodate the multiple stimulus sizes used here. In this model, (i) excitation increased with the fourth-root of stimulus area for all observers, and (ii) IDs in the discrimination data were described by IDs in the relation between suppression and area. This means that empirical summation in the contrast discrimination task can be attributed to growth in suppression with stimulus size that does not keep pace with the growth in excitation. © 2005 ARVO.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Foley [J. Opt. Soc. Am. A 11 (1994) 1710] has proposed an influential psychophysical model of masking in which mask components in a contrast gain pool are raised to an exponent before summation and divisive inhibition. We tested this summation rule in experiments in which contrast detection thresholds were measured for a vertical 1 c/deg (or 2 c/deg) sine-wave component in the presence of a 3 c/deg (or 6 c/deg) mask that had either a single component oriented at -45° or a pair of components oriented at ±45°. Contrary to the predictions of Foley's model 3, we found that for masks of moderate contrast and above, threshold elevation was predicted by linear summation of the mask components in the inhibitory stage of the contrast gain pool. We built this feature into two new models, referred to as the early adaptation model and the hybrid model. In the early adaptation model, contrast adaptation controls a threshold-like nonlinearity on the output of otherwise linear pathways that provide the excitatory and inhibitory inputs to a gain control stage. The hybrid model involves nonlinear and nonadaptable routes to excitatory and inhibitory stages as well as an adaptable linear route. With only six free parameters, both models provide excellent fits to the masking and adaptation data of Foley and Chen [Vision Res. 37 (1997) 2779] but unlike Foley and Chen's model, are able to do so with only one adaptation parameter. However, only the hybrid model is able to capture the features of Foley's (1994) pedestal plus orthogonal fixed mask data. We conclude that (1) linear summation of inhibitory components is a feature of contrast masking, and (2) that the main aftereffect of spatial adaptation on contrast increment thresholds can be assigned to a single site. © 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Using a new optical configuration free from the influence of photorefractive optical nonlinearity, we investigate the main characteristics of the spatial subharmonic K/2 excited in a Bi12SiO20 crystal by a light-intensity pattern with wave vector K and frequency O. It is shown that in a large region of intensity and applied electric field the optimum value O of the frequency corresponds to the conditions of parametric excitation of the weakly damped eigenmodes of the medium: the space-charge waves. The threshold and above-threshold characteristics of the subharmonic regime are in good agreement with the theory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Previous contrast discrimination experiments have shown that luminance contrast is summed across ocular (T. S. Meese, M. A. Georgeson, & D. H. Baker, 2006) and spatial (T. S. Meese & R. J. Summers, 2007) dimensions at threshold and above. However, is this process sufficiently general to operate across the conjunction of eyes and space? Here we used a "Swiss cheese" stimulus where the blurred "holes" in sine-wave carriers were of equal area to the blurred target ("cheese") regions. The locations of the target regions in the monocular image pairs were interdigitated across eyes such that their binocular sum was a uniform grating. When pedestal contrasts were above threshold, the monocular neural images contained strong evidence that the high-contrast regions in the two eyes did not overlap. Nevertheless, sensitivity to dual contrast increments (i.e., to contrast increments in different locations in the two eyes) was a factor of ∼1.7 greater than to single increments (i.e., increments in a single eye), comparable with conventional binocular summation. This provides evidence for a contiguous area summation process that operates at all contrasts and is influenced little, if at all, by eye of origin. A three-stage model of contrast gain control fitted the results and possessed the properties of ocularity invariance and area invariance owing to its cascade of normalization stages. The implications for a population code for pattern size are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study computed trends in extreme precipitation events of Florida for 1950-2010. Hourly aggregated rainfall data from 24 stations of the National Climatic Data Centre were analyzed to derive time-series of extreme rainfalls for 12 durations, ranging from 1 hour to 7 day. Non-parametric Mann-Kendall test and Theil-Sen Approach were applied to detect the significance of trends in annual maximum rainfalls, number of above threshold events and average magnitude of above threshold events for four common analysis periods. Trend Free Pre-Whitening (TFPW) approach was applied to remove the serial correlations and bootstrap resampling approach was used to detect the field significance of trends. The results for annual maximum rainfall revealed dominant increasing trends at the statistical significance level of 0.10, especially for hourly events in longer period and daily events in recent period. The number of above threshold events exhibited strong decreasing trends for hourly durations in all time periods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: Walking training is considered as the first treatment option for patients with peripheral arterial disease and intermittent claudication (IC). Walking exercise has been prescribed for these patients by relative intensity of peak oxygen uptake (VO(2)peak), ranging from 40% to 70% VO(2)peak, or pain threshold (PT). However, the relationship between these methods and anaerobic threshold (AT), which is considered one of the best metabolic markers for establishing training intensity, has not been analyzed. Thus, the aim of this study was to compare, in IC patients, the physiological responses at exercise intensities usually prescribed for training (% VO(2) peak or % PT) with the ones observed at AT. METHODS: Thirty-three IC patients performed maximal graded cardiopulmonary treadmill test to assess exercise tolerance. During the test, heart rate (HR), VO(2), and systolic blood pressure were measured and responses were analyzed at the following: 40% of VO(2)peak; 70% of VO(2)peak; AT; and PT. RESULTS: Heart rate and VO(2) at 40% and 70% of VO(2)peak were lower than those at AT (HR: -13 +/- 9% and -3 +/- 8%, P < .01, respectively; VO(2): -52 +/- 12% and -13 +/- 15%, P < .01, respectively). Conversely, HR and VO(2) at PT were slightly higher than those at AT (HR: +3 +/- 8%, P < .01; VO(2): + 6 +/- 15%, P = .04). None of the patients achieved the respiratory compensation point. CONCLUSION: Prescribing exercise for IC patients between 40% and 70% of VO(2)peak will induce a lower stimulus than that at AT, whereas prescribing exercise at PT will result in a stimulus above AT. Thus, prescribing exercise training for IC patients on the basis of PT will probably produce a greater metabolic stimulus, promoting better cardiovascular benefits.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Controversy still exists concerning the potential ergogenic benefit of caffeine (CAF) for exercise performance. The purpose of this study was to compare the effects of CAF ingestion on endurance performance during exercise on a bicycle ergometer at two different intensities, i.e., approximately 10% below and 10% above the anaerobic threshold (AT). Eight untrained males, non-regular consumers of CAF, participated in this study. AT, defined as the intensity (watts) corresponding to a lactate concentration of 4 mM, was determined during an incremental exercise test from rest to exhaustion on an electrically braked cycle ergometer. On the basis of these measurements, the subjects were asked to cycle until exhaustion at two different intensities, i.e., approximately 10% below and 10% above AT. Each intensity was performed twice in a double-blind randomized order by ingesting either CAF (5 mg/kg) or a placebo (PLA) 60 min prior to the test. Venous blood was analyzed for free fatty acid, glucose, and lactate, before, during, and immediately after exercise. Rating of perceived exertion and time to exhaustion were also measured during each trial. There were no differences in free fatty acids or lactate levels between CAF and PLA during and immediately after exercise for either intensity. Immediately after exercise glucose increased in the CAF trial at both intensities. Rating of perceived exertion was significantly lower (CAF = 14.1 ± 2.5 vs PLA = 16.6 ± 2.4) and time to exhaustion was significantly higher (CAF = 46.54 ± 8.05 min vs PLA = 32.42 ± 14.81 min) during exercise below AT with CAF. However, there was no effect of CAF treatment on rating of perceived exertion (CAF = 18.0 ± 2.7 vs PLA = 17.6 ± 2.3) and time to exhaustion (CAF = 18.45 ± 7.28 min vs PLA = 19.17 ± 4.37 min) during exercise above AT. We conclude that in untrained subjects caffeine can improve endurance performance during prolonged exercise performed below AT and that the decrease of perceived exertion can be involved in this process

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Krypton atoms were excited by photons in the energy range from the threshold for photoionization of the 3d-electrons up to 120 eV. and the fluorescence radiation in the spectral range from 780 to 965 A was observed and analyzed. Cross sections for the population of excited states in KrIII with at least one 4s-hole resulting from an Auger transition as the first decay step and for KrII satellites were determined. The energy dependence of the 3d-ionization cross section in the 3d{_5/2}- and the 3d{_3/2}-threshold range was derived from the experimental data. The cross sections for production of KrII states were found to follow the energy dependence of the 3d-cross sections.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Controversy still exists concerning the potential ergogenic benefit of caffeine (CAF) for exercise performance. The purpose of this study was to compare the effects of CAF ingestion on endurance performance during exercise on a bicycle ergometer at two different intensities, i.e., approximately 10% below and 10% above the anaerobic threshold (AT). Eight untrained males, non-regular consumers of CAF, participated in this study. AT, defined as the intensity (watts) corresponding to a lactate concentration of 4 mM, was determined during an incremental exercise test from rest to exhaustion on an electrically braked cycle ergometer. on the basis of these measurements, the subjects were asked to cycle until exhaustion at two different intensities, i.e., approximately 10% below and 10% above AT. Each intensity was performed twice in a double-blind randomized order by ingesting either CAF (5 mg/kg) or a placebo (PLA) 60 min prior to the test. Venous blood was analyzed for free fatty acid, glucose, and lactate, before, during, and immediately after exercise. Rating of perceived exertion and time to exhaustion were also measured during each trial. There were no differences in free fatty acids or lactate levels between CAF and PLA during and immediately after exercise for either intensity. Immediately after exercise glucose increased in the CAF trial at both intensities. Rating of perceived exertion was significantly lower (CAF = 14.1 ± 2.5 vs PLA = 16.6 ± 2.4) and time to exhaustion was significantly higher (CAF = 46.54 ± 8.05 min vs PLA = 32.42 ± 14.81 min) during exercise below AT with CAF. However, there was no effect of CAF treatment on rating of perceived exertion (CAF = 18.0 ± 2.7 vs PLA = 17.6 ± 2.3) and time to exhaustion (CAF = 18.45 ± 7.28 min vs PLA = 19.17 ± 4.37 min) during exercise above AT. We conclude that in untrained subjects caffeine can improve endurance performance during prolonged exercise performed below AT and that the decrease of perceived exertion can be involved in this process

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Oxygen 1s excitation and ionization processes in the CO2 molecule have been studied with dispersed and non-dispersed fluorescence spectroscopy as well as with the vacuum ultraviolet (VUV) photon?photoion coincidence technique. The intensity of the neutral O emission line at 845 nm shows particular sensitivity to core-to-Rydberg excitations and core?valence double excitations, while shape resonances are suppressed. In contrast, the partial fluorescence yield in the wavelength window 300?650 nm and the excitation functions of selected O+ and C+ emission lines in the wavelength range 400?500 nm display all of the absorption features. The relative intensity of ionic emission in the visible range increases towards higher photon energies, which is attributed to O 1s shake-off photoionization. VUV photon?photoion coincidence spectra reveal major contributions from the C+ and O+ ions and a minor contribution from C2+. No conclusive changes in the intensity ratios among the different ions are observed above the O 1s threshold. The line shape of the VUV?O+ coincidence peak in the mass spectrum carries some information on the initial core excitation

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Data: Photodynamic therapy (PDT) involves the photoinduction of cytotoxicity using a photosensitizer agent, a light source of the proper wavelength, and the presence of molecular oxygen. A model for tissue response to PDT based on the photodynamic threshold dose (Dth) has been widely used. In this model cells exposed to doses below Dth survive while at doses above the Dth necrosis takes place. Objective: This study evaluated the light Dth values by using two different methods of determination. One model concerns the depth of necrosis and the other the width of superficial necrosis. Materials and Methods: Using normal rat liver we investigated the depth and width of necrosis induced by PDT when a laser with a gaussian intensity profile is used. Different light doses, photosensitizers (Photogem, Photofrin, Photosan, Foscan, Photodithazine, and Radachlorin), and concentrations were employed. Each experiment was performed on five animals and the average and standard deviations were calculated. Results: A simple depth and width of necrosis model analysis allows us to determine the threshold dose by measuring both depth and surface data. Comparison shows that both measurements provide the same value within the degree of experimental error. Conclusion: This work demonstrates that by knowing the extent of the superficial necrotic area of a target tissue irradiated by a gaussian light beam, it is possible to estimate the threshold dose. This technique may find application where the determination of Dth must be done without cutting the tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Protective adaptive immune responses rely on TCR-mediated recognition of Ag-derived peptides presented by self-MHC molecules. However, self-Ag (tumor)-specific TCRs are often of too low affinity to achieve best functionality. To precisely assess the relationship between TCR-peptide-MHC binding parameters and T cell function, we tested a panel of sequence-optimized HLA-A(*)0201/NY-ESO-1(157-165)-specific TCR variants with affinities lying within physiological boundaries to preserve antigenic specificity and avoid cross-reactivity, as well as two outliers (i.e., a very high- and a low-affinity TCR). Primary human CD8 T cells transduced with these TCRs demonstrated robust correlations between binding measurements of TCR affinity and avidity and the biological response of the T cells, such as TCR cell-surface clustering, intracellular signaling, proliferation, and target cell lysis. Strikingly, above a defined TCR-peptide-MHC affinity threshold (K(D) < approximately 5 muM), T cell function could not be further enhanced, revealing a plateau of maximal T cell function, compatible with the notion that multiple TCRs with slightly different affinities participate equally (codominantly) in immune responses. We propose that rational design of improved self-specific TCRs may not need to be optimized beyond a given affinity threshold to achieve both optimal T cell function and avoidance of the unpredictable risk of cross-reactivity.