954 resultados para ARM, 100 mT AF, 0.04 mT DF


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes the preparation of acid carboxymethylcellulose (CMCH), and the results of a study on the adsorption and preconcentration (using batch and flow-through column methods) of Cd(II), Cu(II), Cr(III), Fe(III), Ni(II) and Zn(II) in ethanol medium. The adsorption capacities for each metallic ion were (in mmol g(-1)) Cd(II) = 0.92; Cu(II) = 1.45; Cr(III) = 1.70; Fe(III) = 1.60; Ni(II) = 1.30; and Zn(II) = 1.10. By means of the flow-through method, a recovery of ca. 100% of the metallic ions adsorbed in a column packed with 2 g of CMCH was found when 5.0 mL of 1.0 mol L-1 hydrochloric acid were used as eluent. An enrichment factor of 20 (100 mt solution containing 50 mu g L-1 of the metallic ions, concentrated to 5.0 mt) was obtained by this preconcentration procedure. The sorption-desorption procedure applied allowed the development of a preconcentration and Flame AAS quantification method of metallic ions in fuel ethanol at trace levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compararam-se a espectroscopia de ultra-som (US) e os métodos tradicionais (MT) utilizados para a determinação de características físico-químicas do leite e estimaram-se as correlações entre esses métodos e suas acurácias. As características densidade, extrato seco desengordurado (ESD), teor de proteínas e teor de gordura foram determinadas em 65 amostras de leite cru por ambos os métodos. As densidades médias determinadas pelo US e pelos MT não diferiram entre si (P=0,14), e a correlação encontrada entre os dois métodos para a determinação da densidade não foi significativa (P= 0,08). Os teores médios de ESD, proteína e gordura encontrados pelo US e pelos MT foram diferentes (P=0,04, P<0,0001 e P<0,0001, respectivamente), as correlações entre os dois métodos utilizados para a análise dessas características foram positivas e significativas (r=0,0109, r=0,0007, r= <0,0001, respectivamente) e as acurácias dos métodos para essas determinações foram de 0,160, 0,062 e 0,145, respectivamente. Foi determinada a equação de regressão linear, que associa o teor de gordura obtido no método de espectroscopia de ultra-som ao do método butirométrico, que apresentou coeficiente de determinação de 0,5936.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to verify the correlation between the Wingate arm crank test outputs (peak power, mean power, and fatigue index), obtained on a specific ergometer, and the performance in crawl stroke swim sprints of 14, 25, 50, and 400 m. The experiment was conducted with 9 healthy male volunteers (18.1 +/- 2.2 years of age; 172 +/- 0.04 cm; 67.7 +/- 5.92 kg and 15.7 +/- 4.57% body fat). on determined days, all individuals were submitted to the Wingate arm crank test and crawl freestyle sprints of 14, 25, 50, and 400 m as they were timed with a stopwatch. The peak power, the mean power, and the fatigue index, which were obtained during the Wingate arm crank test, were not significantly correlated with the maximum swim velocities during the crawl free-style tests of 14 (r = 0.40; r = 0.64; r = 0.11), 25 (r = 0.28; r = 0.39; r = -0.27), 50 (r = 0.03; r = 0.09; r = -0.31), and 400 (r = -0.52; r = -0.37; r = -0.65) m respectively. Thus, it is possible to conclude that the Wingate arm crank test is not suitable to assess the anaerobic power of swimmers under the described experimental conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new and fast procedure is proposed for cleaning autosampler cups using acid-vapor steam-cleaning with a miniaturized assembly in a microwave-heated sealed Teflon vessel. A glass cactus-shaped holder was made to support six polyethylene autosampler cups (volume, 2.0 mt) inside a 100 mt microwave vessel. Regent-grade nitric acid was added to the vessels, and the system was heated in a microwave oven for 5 min at 300 W. Chromium was determined by graphite-furnace atomic-absorption spectrophotometry. The blank values were lower with cleaned cups compared to untreated cups (i.e., as received from supplier). The quantification limits, estimated from detection limits established with Milli-Q water, were 0.66 and 0.95 mu g Cr L-1 for cleaned and untreated auto-sampler cups, respectively. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to verify the correlation between the Wingate arm crank test outputs (peak power, mean power, and fatigue index), obtained on a specific ergometer, and the performance in crawl stroke swim sprints of 14, 25, 50, and 400 m. The experiment was conducted with 9 healthy male volunteers (18.1 ± 2.2 years of age; 172 ± 0.04 cm; 67.7 ± 5.92 kg and 15.7 ± 4.57% body fat). On determined days, all individuals were submitted to the Wingate arm crank test and crawl freestyle sprints of 14, 25, 50, and 400 m as they were timed with a stopwatch. The peak power, the mean power, and the fatigue index, which were obtained during the Wingate arm crank test, were not significantly correlated with the maximum swim velocities during the crawl freestyle tests of 14 (r = 0.40; r = 0.64; r = 0.11), 25 (r = 0.28; r = 0.39; r = -0.17), 50 (r = 0.03; r = 0.09; r = -0.31), and 400 (r = -0.52; r = -0.37; r = -0.65) m, respectively. Thus, it is possible to conclude that the Wingate arm crank test is not suitable to assess the anaerobic power of swimmers under the described experimental conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background-The Second Medicine, Angioplasty, or Surgery Study (MASS II) included patients with multivessel coronary artery disease and normal systolic ventricular function. Patients underwent coronary artery bypass graft surgery (CABG, n = 203), percutaneous coronary intervention (PCI, n = 205), or medical treatment alone (MT, n = 203). This investigation compares the economic outcome at 5-year follow-up of the 3 therapeutic strategies. Methods and Results-We analyzed cumulative costs during a 5-year follow-up period. To analyze the cost-effectiveness, adjustment was made on the cumulative costs for average event-free time and angina-free proportion. Respectively, for event-free survival and event plus angina-free survival, MT presented 3.79 quality-adjusted life-years and 2.07 quality-adjusted life-years; PCI presented 3.59 and 2.77 quality-adjusted life-years; and CABG demonstrated 4.4 and 2.81 quality-adjusted life-years. The event-free costs were $9071.00 for MT; $19 967.00 for PCI; and $18 263.00 for CABG. The paired comparison of the event-free costs showed that there was a significant difference favoring MT versus PCI (P<0.01) and versus CABG (P<0.01) and CABG versus PCI (P<0.01). The event-free plus angina-free costs were $16 553.00, $25 831.00, and $24 614.00, respectively. The paired comparison of the event-free plus angina-free costs showed that there was a significant difference favoring MT versus PCI (P=0.04), and versus CABG (P<0.001); there was no difference between CABG and PCI (P>0.05). Conclusions-In the long-term economic analysis, for the prevention of a composite primary end point, MT was more cost effective than CABG, and CABG was more cost-effective than PCI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] To determine central and peripheral hemodynamic responses to upright leg cycling exercise, nine physically active men underwent measurements of arterial blood pressure and gases, as well as femoral and subclavian vein blood flows and gases during incremental exercise to exhaustion (Wmax). Cardiac output (CO) and leg blood flow (BF) increased in parallel with exercise intensity. In contrast, arm BF remained at 0.8 l/min during submaximal exercise, increasing to 1.2 +/- 0.2 l/min at maximal exercise (P < 0.05) when arm O(2) extraction reached 73 +/- 3%. The leg received a greater percentage of the CO with exercise intensity, reaching a value close to 70% at 64% of Wmax, which was maintained until exhaustion. The percentage of CO perfusing the trunk decreased with exercise intensity to 21% at Wmax, i.e., to approximately 5.5 l/min. For a given local Vo(2), leg vascular conductance (VC) was five- to sixfold higher than arm VC, despite marked hemoglobin deoxygenation in the subclavian vein. At peak exercise, arm VC was not significantly different than at rest. Leg Vo(2) represented approximately 84% of the whole body Vo(2) at intensities ranging from 38 to 100% of Wmax. Arm Vo(2) contributed between 7 and 10% to the whole body Vo(2). From 20 to 100% of Wmax, the trunk Vo(2) (including the gluteus muscles) represented between 14 and 15% of the whole body Vo(2). In summary, vasoconstrictor signals efficiently oppose the vasodilatory metabolites in the arms, suggesting that during whole body exercise in the upright position blood flow is differentially regulated in the upper and lower extremities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the elastic response of cell membranes to mechanical stimuli plays a key role in various cellular processes, novel biophysical strategies to quantify the elasticity of native membranes under physiological conditions at a nanometer scale are gaining interest. In order to investigate the elastic response of apical membranes, elasticity maps of native membrane sheets, isolated from MDCK II (Madine Darby Canine kidney strain II) epithelial cells, were recorded by local indentation with an Atomic Force Microscope (AFM). To exclude the underlying substrate effect on membrane indentation, a highly ordered gold coated porous array with a pore diameter of 1.2 μm was used to support apical membranes. Overlays of fluorescence and AFM images show that intact apical membrane sheets are attached to poly-D-lysine coated porous substrate. Force indentation measurements reveal an extremely soft elastic membrane response if it is indented at the center of the pore in comparison to a hard repulsion on the adjacent rim used to define the exact contact point. A linear dependency of force versus indentation (-dF/dh) up to 100 nm penetration depth enabled us to define an apparent membrane spring constant (kapp) as the slope of a linear fit with a stiffness value of for native apical membrane in PBS. A correlation between fluorescence intensity and kapp is also reported. Time dependent hysteresis observed with native membranes is explained by a viscoelastic solid model of a spring connected to a Kelvin-Voight solid with a time constant of 0.04 s. No hysteresis was reported with chemically fixated membranes. A combined linear and non linear elastic response is suggested to relate the experimental data of force indentation curves to the elastic modulus and the membrane thickness. Membrane bending is the dominant contributor to linear elastic indentation at low loads, whereas stretching is the dominant contributor for non linear elastic response at higher loads. The membrane elastic response was controlled either by stiffening with chemical fixatives or by softening with F-actin disrupters. Overall, the presented setup is ideally suitable to study the interactions of the apical membrane with the underlying cytoskeleton by means of force indentation elasticity maps combined with fluorescence imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The aim of this study was to assess the role of transcatheter aortic valve implantation (TAVI) compared with medical treatment (MT) and surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis (AS) at increased surgical risk. Background Elderly patients with comorbidities are at considerable risk for SAVR. Methods Since July 2007, 442 patients with severe AS (age: 81.7 ± 6.0 years, mean logistic European System for Cardiac Operative Risk Evaluation: 22.3 ± 14.6%) underwent treatment allocation to MT (n = 78), SAVR (n = 107), or TAVI (n = 257) on the basis of a comprehensive evaluation protocol as part of a prospective registry. Results Baseline clinical characteristics were similar among patients allocated to MT and TAVI, whereas patients allocated to SAVR were younger (p < 0.001) and had a lower predicted peri-operative risk (p < 0.001). Unadjusted rates of all-cause mortality at 30 months were lower for SAVR (22.4%) and TAVI (22.6%) compared with MT (61.5%, p < 0.001). Adjusted hazard ratios for death were 0.51 (95% confidence interval: 0.30 to 0.87) for SAVR compared with MT and 0.38 (95% confidence interval: 0.25 to 0.58) for TAVI compared with MT. Medical treatment (<0.001), older age (>80 years, p = 0.01), peripheral vascular disease (<0.001), and atrial fibrillation (p = 0.04) were significantly associated with all-cause mortality at 30 months in the multivariate analysis. At 1 year, more patients undergoing SAVR (92.3%) or TAVI (93.2%) had New York Heart Association functional class I/II as compared with patients with MT (70.8%, p = 0.003). Conclusions Among patients with severe AS with increased surgical risk, SAVR and TAVI improve survival and symptoms compared with MT. Clinical outcomes of TAVI and SAVR seem similar among carefully selected patients with severe symptomatic AS at increased risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to assess sleep-wake habits and disorders and excessive daytime sleepiness (EDS) in an unselected outpatient epilepsy population. Sleep-wake habits and presence of sleep disorders were assessed by means of a clinical interview and a standard questionnaire in 100 consecutive patients with epilepsy and 90 controls. The questionnaire includes three validated instruments: the Epworth Sleepiness Scale (ESS) for EDS, SA-SDQ for sleep apnea (SA), and the Ullanlinna Narcolepsy Scale (UNS) for narcolepsy. Sleep complaints were reported by 30% of epilepsy patients compared to 10% of controls (p=0.001). The average total sleep time was similar in both groups. Insufficient sleep times were suspected in 24% of patients and 33% of controls. Sleep maintenance insomnia was more frequent in epilepsy patients (52% vs. 38%, p=0.06), whereas nightmares (6% vs. 16%, p=0.04) and bruxism (10% vs. 19%, p=0.07) were more frequent in controls. Sleep onset insomnia (34% vs. 28%), EDS (ESS >or=10, 19% vs. 14%), SA (9% vs. 3%), restless legs symptoms (RL-symptoms, 18% vs. 12%) and most parasomnias were similarly frequent in both groups. In a stepwise logistic regression model loud snoring and RL-symptoms were found to be the only independent predictors of EDS in epilepsy patients. In conclusion, sleep-wake habits and the frequency of most sleep disorders are similar in non-selected epilepsy patients as compared to controls. In epilepsy patients, EDS was predicted by a history of loud snoring and RL-symptoms but not by SA or epilepsy-related variables (including type of epilepsy, frequency of seizures, and number of antiepileptic drugs).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of two active volcanoes in the western branch of the East African Rift, Nyamuragira (1.408ºS, 29.20ºE; 3058 m) is located in the D.R. Congo. Nyamuragira emits large amounts of SO2 (up to ~1 Mt/day) and erupts low-silica, alkalic lavas, which achieve flow rates of up to ~20 km/hr. The source of the large SO2 emissions and pre-eruptive magma conditions were unknown prior to this study, and 1994-2010 lava volumes were only recently mapped via satellite imagery, mainly due to the region’s political instability. In this study, new olivine-hosted melt inclusion volatile (H2O, CO2, S, Cl, F) and major element data from five historic Nyamuragira eruptions (1912, 1938, 1948, 1986, 2006) are presented. Melt compositions derived from the 1986 and 2006 tephra samples best represent pre-eruptive volatile compositions because these samples contain naturally glassy inclusions that underwent less post-entrapment modification than crystallized inclusions. The total amount of SO2 released from the 1986 (0.04 Mt) and 2006 (0.06 Mt) eruptions are derived using the petrologic method, whereby S contents in melt inclusions are scaled to erupted lava volumes. These amounts are significantly less than satellite-based SO2 emissions for the same eruptions (1986 = ~1 Mt; 2006 = ~2 Mt). Potential explanations for this observation are: 1) accumulation of a vapor phase within the magmatic system that is only released during eruptions, and/or 2) syn-eruptive gas release from unerupted magma. Post-1994 Nyamuragira lava volumes were not available at the beginning of this study. These flows (along with others since 1967) are mapped with Landsat MSS, TM, and ETM+, Hyperion, and ALI satellite data and combined with published flow thicknesses to derive volumes. Satellite remote sensing data was also used to evaluate Nyamuragira SO2 emissions. These results show that the most recent Nyamuragira eruptions injected SO2 into the atmosphere between 15 km (2006 eruption) and 5 km (2010 eruption). This suggests that past effusive basaltic eruptions (e.g., Laki 1783) are capable of similar plume heights that reached the upper troposphere or tropopause, allowing SO2 and resultant aerosols to remain longer in the atmosphere, travel farther around the globe, and affect global climates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND In experimental animal studies, pulsing the CO2 laser beam has been shown to reduce the thermal damage zone of excised oral mucosal tissue. However, there is still controversy over whether this is borne out under clinical conditions. OBJECTIVE To compare the outcome following excisional biopsies of fibrous hyperplasias using a pulsed (cf) versus a continuous wave (cw) CO2 laser mode regarding the thermal damage zone, duration of surgeries, intra- and postoperative complications, postoperative pain sensation, scarring and/or relapse during the initial 6 months. MATERIALS AND METHODS One hundred Swiss-resident patients with a fibrous hyperplasia in their buccal mucosa were randomly assigned to the cw mode (5 W) or the cf mode (140 Hz, 400 microseconds, 33 mJ, 4.62 W) group. All excisions were performed by one single oral surgeon. Postoperative pain (2 weeks) was recorded by visual analogue scale (VAS; ranging from 0 to 100). Intake of analgesics and postoperative complications were recorded in a standardized study form. The maximum width of the collateral thermal damage zone was measured (µm) in excision specimens by one pathologist. Intraoral photographs at 6-month follow-up examinations were evaluated regarding scarring (yes/no). RESULTS Median duration of the excision was 65 seconds in the cw and 81 seconds in the cf group (P = 0.13). Intraoperative bleeding occurred in 16.3% of the patients in the cw and 17.7% of the cf group. The median value of the thermal damage zone was 161(±228) μm in the cw and 152(± 105) μm in the cf group (P = 0.68). The reported postoperative complications included swelling in 19% and minor bleeding in 6% without significant differences between the two laser modes. When comparing each day separately or the combined mean VAS scores of both groups between Days 1-3, 1-7, and 1-15, there were no significant differences. However, more patients of the cw group (25%) took analgesics than patients of the cf group (9.8%) resulting in a borderline significance (P = 0.04). Scarring at the excision site was found in 50.6% of 77 patients after 6 months, and more scars were identified in cases treated with the cf mode (P = 0.03). CONCLUSIONS Excision of fibrous hyperplasias performed with a CO2 laser demonstrated a good clinical outcome and long-term predictability with a low risk of recurrence regardless of the laser mode (cf or cw) used. Scarring after 6 months was only seen in 50.6% of the cases and was slightly more frequent in the cf mode group. Based on the findings of the present study, a safety border of 1 mm appears sufficient for both laser modes especially when performing a biopsy of a suspicious soft tissue lesion to ensure a proper histopathological examination.