995 resultados para ANTERIOR SPINAL ARTERY
Resumo:
BACKGROUND: Bioresorbable vascular scaffolds (BVS) were recently approved for percutaneous coronary intervention in Europe. The aim of this position statement is to review the information and studies on available BVS, to stimulate discussion on their use and to propose guidelines for this treatment option in Portugal. METHODS AND RESULTS: A working group was set up to reach a consensus based on current evidence, discussion of clinical case models and individual experience. The evidence suggests that currently available BVS can produce physiological and clinical improvements in selected patients. There are encouraging data on their durability and long-term safety. Initial indications were grouped into three categories: (a) consensual and appropriate - young patients, diabetic patients, left anterior descending artery, long lesions, diffuse disease, and hybrid strategy; (b) less consensual but possible - small collateral branches, stabilized acute coronary syndromes; and (c) inappropriate - left main disease, tortuosity, severe calcification. CONCLUSION: BVS are a viable treatment option based on the encouraging evidence of their applicability and physiological and clinical results. They should be used in appropriate indications and will require technical adaptations. Outcome monitoring and evaluation is essential to avoid inappropriate use. It is recommended that medical societies produce clinical guidelines based on high-quality registries as soon as possible.
Resumo:
INTRODUCTION: The index of microcirculatory resistance (IMR) enables/provides quantitative, invasive, and real-time assessment of coronary microcirculation status. AIMS: The primary aim of this study was to validate the assessment of IMR in a large animal model, and the secondary aim was to compare two doses of intracoronary papaverine, 5 and 10 mg, for induction of maximal hyperemia and its evolution over time. METHODS: Measurements of IMR were performed in eight pigs. Mean distal pressure (Pd) and mean transit time (Tmn) were measured at rest and at maximal hyperemia induced with intracoronary papaverine, 5 and 10 mg, and after 2, 5, 8 and 10 minutes. Disruption of the microcirculation was achieved by selective injection of 40-μm microspheres via a microcatheter in the left anterior descending artery. RESULTS: In each animal 14 IMR measurements were made. There were no differences between the two doses of papaverine regarding Pd response and IMR values - 11 ± 4.5 U with 5 mg and 10.6 ± 3 U with 10 mg (p=0.612). The evolution of IMR over time was also similar with the two doses, with significant differences from resting values disappearing after five minutes of intracoronary papaverine administration. IMR increased with disrupted microcirculation in all animals (41 ± 16 U, p=0.001). CONCLUSIONS: IMR provides invasive and real-time assessment of coronary microcirculation. Disruption of the microvascular bed is associated with a significant increase in IMR. A 5-mg dose of intracoronary papaverine is as effective as a 10-mg dose in inducing maximal hyperemia. After five minutes of papaverine administration there is no significant difference from resting hemodynamic status.
Resumo:
OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of in-stent restenosis. METHODS: Twenty-five patients with 33 incidents of in-stent restenosis treated with excimer laser coronary angioplasty (ELCA) were analyzed. Sixty-six percent were males, mean age of 73±11 years, and 83% were functional class III-IV (NYHA). ELCA was performed using 23 concentric and 10 eccentric catheters with a diameter of 1.6-2.2 mm, followed by balloon angioplasty (PTCA) and ultrasound monitoring. The procedure was performed in the following vessels: left anterior descending artery, 10; left circumflex artery, 8; right coronary artery, 6; left main coronary artery, 2; and venous bypass graft, 7. RESULTS: The ELCA was successful in 71% of the cases, and PTCA was 100% successful. The diameter of the treated vessels was 3.44±0.5mm; the minimal luminal diameter (MLD) increased from 0.30mm pre-ECLA to 1.97mm post-ELCA, and to 2.94mm post-PTCA (p<0.001). The percent stenosis was reduced from 91.4±9.5% before ECLA to 42.3±14.9% after ELCA and to 14.6 ± 9.3% after PTCA (p<0.001). Seventeen (68%) patients were asymptomatic at 6 months and 15 (60%) at 1 year. New restenosis rates were 8/33 (24.2%) at 6 months and 9 /33 (27.3%) at 12 months. CONCLUSION: ELCA is safe and effective for the treatment of in-stent restenosis. In the present sample, a slight increase in new restenotic lesions between 6 and 12 months was found.
Resumo:
OBJECTIVE: To assess the feasibility and safety of coronary interventions performed through the radial artery. METHODS: We studied 103 patients with ages from 38 to 86 years (57±8.7), 90 (87%) males, and: radial pulse with a good amplitude, presence of ulnar pulse, a good collateral flow through the palmar arch assessed with the Allen's test. RESULTS: The vascular approach was obtained in 97 (94%) patients, 88 (91%) treated electively and 9 (9%) during acute myocardial infarction, for primary angioplasty; 56 (64%) unstable angina; 22 (25%) stable angina; 10 (11%) were asymptomatic, 6 referred for recanalization of chronic occlusion and 4 silent ischemia in the first week after acute myocardial infarction. We approached 107 arteries: anterior descending artery, 49 (46%); right coronary artery, 27 (25%); circumflex artery, 25 (23%); diagonal artery, 6 (6%); and 2 saphenous vein bypass grafts. We treated 129 lesions: 80 (62%) B2 type; 23 (18%) B1 type; 17 (13%) C type; and 9 (7%). A type. There were 70 stents , and 59 balloon angioplasties performed. Thirty-two (33%) patients used GP IIb/IIIa inhibitors. The mean duration of the elective procedure was 42.3±12.8 min. Success, correct stent deployment and residual lesion <20%, was reached in 100% of the lesions treated with stent implantation; arterial dilation with residual lesion <50% was obtained in 96% of the lesions treated with transluminal coronary angioplasty (TCA). Complications, were: 1 (1.0%) non-Q-wave acute myocardial infarction; 2 (2%) hematomas in the forearm; and 2 losses of radial pulse. CONCLUSION: Radial artery aproach is practical and safe for percutaneous coronary interventions there was a low incidence of complications.
Resumo:
A woman aged 98 years entered the tertiary hospital service with a picture of acute myocardial infarction of the extensive anterior wall, which began 4 hours earlier. Due to the large myocardial risk area suggested by the electrocardiogram, the patient was taken to the hemodynamics laboratory for the performance of emergency coronary arteriography, which revealed occlusion in the proximal third of the anterior descending artery. Primary angioplasty followed by stent grafting was successfully performed. The patient had a satisfactory evolution (Killip I) and was discharged from the hospital on the seventh postinfarction day. We discuss here aspects of thrombolysis and coronary percutaneous interventions in the aged.
Kawasaki disease: involution of giant coronary aneurysms after prolonged anti-inflammatory treatment
Resumo:
The patient is a 5-year-old male with Kawasaki disease, whose involution of giant aneurysms of the left coronary arteries was surprising after a prolonged period of treatment, which lasted 80 uninterrupted days and comprised anti-inflammatory drugs associated with anticoagulation agents. The distal diameters of the anterior interventricular, the diagonal, and the circumflex arteries normalized by the end of the treatment. A residual giant aneurysm localized at the beginning of the anterior interventricular artery did not cause ischemia. Continuation of the medication for a prolonged period was recommended.
Resumo:
BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.
Resumo:
Anterior spinal infection (prevertebral abscess and/or discitis) after posterior instrumentation for vertebral fractures is a challenging complication, since a new implant may become necessary anteriorly, in a septic environment. Generally accepted management guidelines are yet to be established. The authors present a case of posterior instrumentation for fractures of T12 and L1, complicated after 9 months with an anterior infection (prevertebral abscess and discitis) with extended-spectrum beta-lactamase (ESBL) producing Escherichia coli (E. coli). This case is unique in that the multi-resistant organism was isolated only after the second stage of infection treatment, which consisted of anterior débridement and anterior implantation of titanium cages and rods. In this particular case, infection was controlled despite implantation of multiple cages, screws and rods, and fusion was achieved, by means of intravenous antibiotic treatment for 12 months. At the latest follow-up, 24 months post surgery, there was no evidence of infection. This problem case may be helpful for surgeons confronted with spinal deformities secondary to infections with multi-resistant organisms.
Resumo:
In this article we describe a 41-year-old man who, following an operation to repair a ruptured anterior communicating artery aneurysm, manifested the "hallmark" features of a dysexecutive memory impairment. Of particular note was the patient's apparently normal level of recognition memory but impaired recall on tasks matched for difficulty in control subjects. However, further testing revealed that the patient's recognition memory was not normal under all circumstances. Implications of these data for the interpretation and further investigation of the dysexecutive deficit are discussed.
Resumo:
Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien? XT stent-valve implantation through the fibrotic thin akinetic apical wall.
Resumo:
BACKGROUND: A device to perform sutureless end-to-side coronary artery anastomosis has been developed by means of stent technology (GraftConnector). The present study assesses the long-term quality of the GraftConnector anastomosis in a sheep model. METHODS: In 8 adult sheep, 40-55 kg in weight, through left anterior thoracotomy, the right internal mammary artery (RIMA) was prepared and connected to the left anterior descending artery (LAD) by means of GraftConnector, on beating heart, without using any stabilizer. Ticlopidine 250 mg/day for anticoagulation for 4 weeks and Aspirin 100 mg/day for 6 months were given. The animals were sacrificed after 6 months and histological examination of anastomoses was carried out after slicing with the connector in situ for morphological analysis. RESULTS: All animals survived at 6 months. All anastomoses were patent and mean luminal width at histology was 1.8 +/- 0.2 mm; mean myotomia hyperplasia thickness was 0.21 +/- 0.1 mm. CONCLUSIONS: Long-term results demonstrate that OPCABGs performed with GraftConnector had 100% patency rate. The mean anastomotic luminal width corresponds to mean LAD's adult sheep diameter. We may speculate that myotomia hyperplasia occurred as a result of local device oversizing.
Resumo:
BACKGROUND: Diplopia related to neurosurgical procedures is often consecutive to oculomotor nerve lesions. We hereby report an oculomotor dysfunction secondary to an orbital roof effraction and its treatment. HISTORY AND SIGNS: Following surgery for a left anterior communicating artery aneurysm, a 45-year-old woman reported vertical diplopia associated with a left orbital hematoma. The diagnosis of third cranial nerve palsy was excluded by orbital imaging which revealed an orbital roof defect with incarceration of the levator palpebrae and superior rectus. THERAPY AND OUTCOME: As neurosurgeons advised against muscle adhesiolysis, diplopia was corrected by a two-step procedure on the oculomotor muscles. We first corrected horizontal and torsional deviations by operating on the healthy eye, before correcting the vertical deviation on the fellow eye. This two-step extraocular muscle surgery allowed restoration of binocular single vision in a useful field of gaze. CONCLUSIONS: Diplopia can occur as a rare orbital complication during neurosurgical procedures. Surgery of extraocular muscles can provide good functional results
Resumo:
BACKGROUND: Acute stroke presenting as monoparesis is rare, with a pure motor deficit in the arm or leg extending to an isolated facial paresis. OBJECTIVE: To raise the question if acute stroke presenting as monoparesis is a different entity from stroke with a more extensive motor deficit. PATIENTS: In the Lausanne Stroke Registry (1979-2000), 195 (4.1%) of 4802 patients met the clinical criteria for pure monoparesis involving the face (22%), arm (63%), or leg (15%). RESULTS: In the vast majority of cases (> 95%), monoparesis corresponded to ischemic stroke with a favorable outcome, with initial computed tomography scans or magnetic resonance images showing no signs of hemorrhage. The lesion for a facial deficit was most frequently located subcortically (internal capsule); for an arm deficit, in the superficial middle cerebral artery; and for a leg deficit, in the anterior cerebral artery territory. In pure monoparesis, only 17% of the patients had more than 1 risk factor as compared with 26% of those with bimodal and trimodal hemiparesis and with 46% of all patients with stroke other than those with pure motor stroke. The only frequent risk factor was hypertension (53%); however, this frequency was no different from that in other patients with stroke. No major stroke etiology could be identified in any of the 3 subgroups of monoparesis. CONCLUSION: Our finding of a wide range of stroke localization and etiology in monoparesis without any particular subgroup suggests that no specific plan of investigation can be recommended for these patients.
Resumo:
PURPOSE: To evaluate the effect of a real-time adaptive trigger delay on image quality to correct for heart rate variability in 3D whole-heart coronary MR angiography (MRA). MATERIALS AND METHODS: Twelve healthy adults underwent 3D whole-heart coronary MRA with and without the use of an adaptive trigger delay. The moment of minimal coronary artery motion was visually determined on a high temporal resolution MRI. Throughout the scan performed without adaptive trigger delay, trigger delay was kept constant, whereas during the scan performed with adaptive trigger delay, trigger delay was continuously updated after each RR-interval using physiological modeling. Signal-to-noise, contrast-to-noise, vessel length, vessel sharpness, and subjective image quality were compared in a blinded manner. RESULTS: Vessel sharpness improved significantly for the middle segment of the right coronary artery (RCA) with the use of the adaptive trigger delay (52.3 +/- 7.1% versus 48.9 +/- 7.9%, P = 0.026). Subjective image quality was significantly better in the middle segments of the RCA and left anterior descending artery (LAD) when the scan was performed with adaptive trigger delay compared to constant trigger delay. CONCLUSION: Our results demonstrate that the use of an adaptive trigger delay to correct for heart rate variability improves image quality mainly in the middle segments of the RCA and LAD.
Resumo:
The aims of this study were to determine whether responses in myocardial blood flow (MBF) to the cold pressor testing (CPT) method noninvasively with PET correlate with an established and validated index of flow-dependent coronary vasomotion on quantitative angiography. METHODS: Fifty-six patients (57 +/- 6 y; 16 with hypertension, 10 with hypercholesterolemia, 8 smokers, and 22 without coronary risk factors) with normal coronary angiograms were studied. Biplanar end-diastolic images of a selected proximal segment of the left anterior descending artery (LAD) (n = 27) or left circumflex artery (LCx) (n = 29) were evaluated with quantitative coronary angiography in order to determine the CPT-induced changes of epicardial luminal area (LA, mm(2)). Within 20 d of coronary angiography, MBF in the LAD, LCx, and right coronary artery territory was measured with (13)N-ammonia and PET at baseline and during CPT. RESULTS: CPT induced on both study days comparable percent changes in the rate x pressure product (%DeltaRPP, 37% +/- 13% and 40% +/- 17%; P = not significant [NS]). For the entire study group, the epicardial LA decreased from 5.07 +/- 1.02 to 4.88 +/- 1.04 mm(2) (DeltaLA, -0.20 +/- 0.89 mm(2)) or by -2.19% +/- 17%, while MBF in the corresponding epicardial vessel segment increased from 0.76 +/- 0.16 to 1.03 +/- 0.33 mL x min(-1) x g(-1) (DeltaMBF, 0.27 +/- 0.25 mL x min(-1) x g(-1)) or 36% +/- 31% (P <or= 0.0001). However, in normal controls without coronary risk factors (n = 22), the epicardial LA increased from 5.01 +/- 1.07 to 5.88 +/- 0.89 mm(2) (19.06% +/- 8.9%) and MBF increased from 0.77 +/- 0.16 to 1.34 +/- 0.34 mL x min(-1) x g(-1) (74.08% +/- 23.5%) during CPT, whereas patients with coronary risk factors (n = 34) revealed a decrease of epicardial LA from 5.13 +/- 1.48 to 4.24 +/- 1.12 mm(2) (-15.94% +/- 12.2%) and a diminished MBF increase (from 0.76 +/- 0.20 to 0.83 +/- 0.25 mL x min(-1) x g(-1) or 10.91% +/- 19.8%) as compared with controls (P < 0.0001, respectively), despite comparable changes in the RPP (P = NS). In addition, there was a significant correlation (r = 0.87; P <or= 0.0001) between CPT-related percent changes in LA on quantitative angiography and in MBF as measured with PET. CONCLUSION: The observed close correlation between an angiographically established parameter of flow-dependent and, most likely, endothelium-mediated coronary vasomotion and PET-measured MBF further supports the validity and value of MBF responses to CPT as a noninvasively available index of coronary circulatory function.