965 resultados para AGULHAS LEAKAGE
Bacterial leakage in root canals obturated by different techniques. Part 1: microbiologic evaluation
Resumo:
Objective. This study compared the coronal bacterial leakage of root canals obturated by different techniques and with different lengths of obturation. Study design. The canals of palatal roots of 160 maxillary molars were instrumented and divided into different groups according to the obturation technique used (lateral condensation, Microseal system, Touch `n Heat + Ultrafil system, or Tagger`s hybrid technique) and the length of obturation (5 mm or 10 mm). The roots were impermeabilized, sterilized in ethylene oxide, and mounted on a device for evaluation of the bacterial leakage. Results. Tagger`s hybrid technique produced a statistically greater number of specimens with coronal leakage than the other techniques. There was no statistically significant difference between the lateral condensation, Touch `n Heat + Ultrafil, and Microseal groups. Root canals with 10 mm of obturation produced a statistically significantly smaller number of specimens with leakage than root canals with 5 mm of obturation. Conclusion. Tagger`s hybrid technique produced a greater number of specimens with coronal leakage than the other techniques, and a greater number of root canals with 5 mm of obturation leaked than root canals with 10 mm of obturation.
Resumo:
Objective. The objective of this study was to evaluate the sealing ability of AH Plus, Epiphany, Acroseal, Endofill, and Polifil after active lateral condensation technique, by using a bacterial test, during 64 days. Study design. One hundred bovine incisors were cleaned and shaped; then they were filled with the endodontic sealers and adapted into a microcentrifuge tube. The setup root/microcentrifuge tube was added to glass flasks containing Brain Heart Infusion broth. A culture of Enterococcus faecalis was inserted into the upper chamber of each assembly. Daily leakage was evaluated through the broth turbidity. Results. The results were submitted to statistical analysis (Kaplan-Meier method, Kruskal-Wallis and Dunn tests). Conclusions. AH Plus and Endofill had the worst sealing ability when compared with Polifil, which showed the least leakage. Acroseal and Epiphany showed a tendency toward having an intermediate behavior; however, there was no significant difference among Acroseal, Epiphany, and the other sealers. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: e56-e60)
Resumo:
The aim of this in vitro study was to evaluate bacterial leakage along the implant-abutment interface under unloaded conditions. Twelve premachined abutments with plastic sleeves and 12 dental implants were used in this study. Prior to tests of bacterial leakage, samples from the inner parts of the implants were collected with sterile microbrushes to serve as negative controls for contamination. After casting, the abutments were tightened to 32 Ncm on the implants. The assemblies were immersed in 2.0 mL of human saliva and incubated for 7 days. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all the implants evaluated. Aggregatibacter actinomycetemcomitans and Capnocytophaga gingivalis were the most incident species. No microorganisms were found in the samples recovered from the implants before contamination testing (negative control). Bacterial species from human saliva may penetrate the implant-abutment interface under unloaded conditions. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:782-787
Resumo:
Objectives Bacterial penetration along the implant-abutment interface as a consequence of abutment screw loosening has been reported in a number of recent studies. The aim of this in vitro study was to investigate the influence of repeated tightening of the abutment screw on leakage of Streptococcus mutans along the interface between implants and pre-machined abutments. Materials and methods Twenty pre-machined abutments with a plastic sleeve were used. The abutment screws were tightened to 32 N cm in group 1 (n=10 - control) and to 32 N cm, loosened and re-tightened with the same torque twice in group 2 (n=10). The assemblies were completely immersed in 5 ml of Tryptic Soy Broth medium inoculated with S. mutans and incubated for 14 days. After this period, contamination of the implant internal threaded chamber was evaluated using the DNA Checkerboard method. Results Microorganisms were found on the internal surfaces of both groups evaluated. However, bacterial counts in group 2 were significantly higher than that in the control group (P < 0.05). Conclusion These results suggest that bacterial leakage between implants and abutments occurs even under unloaded conditions and at a higher intensity when the abutment screw is tightened and loosened repeatedly. To cite this article:do Nascimento C, Pedrazzi V, Kirsten Miani P, Daher Moreira L, de Albuquerque Junior RF. Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface.Clin. Oral Impl. Res. 20, 2009; 1394-1397.doi: 10.1111/j.1600-0501.2009.01769.x.
Resumo:
With progressing CMOS technology miniaturization, the leakage power consumption starts to dominate the dynamic power consumption. The recent technology trends have equipped the modern embedded processors with the several sleep states and reduced their overhead (energy/time) of the sleep transition. The dynamic voltage frequency scaling (DVFS) potential to save energy is diminishing due to efficient (low overhead) sleep states and increased static (leakage) power consumption. The state-of-the-art research on static power reduction at system level is based on assumptions that cannot easily be integrated into practical systems. We propose a novel enhanced race-to-halt approach (ERTH) to reduce the overall system energy consumption. The exhaustive simulations demonstrate the effectiveness of our approach showing an improvement of up to 8 % over an existing work.
Resumo:
NORTH SEA STUDY OCCASIONAL PAPER No. 115
Resumo:
O objetivo deste estudo foi aferir a porcentagem de recirculação sangüínea (%R), nas diferentes formas de punções nas fístulas artério-venosa de pacientes em hemodiálise. Verificou-se o nível de uréia sangüínea em oito pacientes utilizando o modelo clássico de punção e de outros três grupos de oito pacientes com diferentes tipos de punção, simultânea e imediatamente após transcorridos 10 minutos de sessão, na linha arterial (A), linha venosa (V) e membro contra-lateral ao acesso vascular (S), aplicando-se a fórmula %R = (S-A) I (S-V) . 100. Constatamos que na forma clássica de punção houve uma a porcentagem de recirculação significativamente menor.
Resumo:
Este estudo clínico randomizado objetivou avaliar os níveis de estresse na equipe de Enfermagem de um hospital e analisar a efetividade da auriculoterapia com agulhas e sementes. 75 pessoas com escores médio (44/58,7%) e alto (31/41,3%) de acordo com a Lista de Sintomas de Estresse foram divididas em grupos (controle, agulhas e sementes), que receberam oito sessões nos pontos Shenmen, Rim e Tronco Cerebral e foram avaliados no início, com quatro, oito sessões e follow-up (15 dias). Na análise de variância (ANOVA), constataram-se diferenças entre os grupos, na 3ª avaliação (F=3,963/P=0,023) e follow-up (F=6,136/P=0,003). Tais diferenças foram entre o grupo controle e agulha. Os grupos de intervenção mostraram diferenças (P<0,05) a partir da segunda avaliação, quando comparados dentro do mesmo grupo. Concluiu-se que a auriculoterapia reduziu o estresse em profissionais de enfermagem, com melhores resultados para agulhas do que sementes, em escores altos, com manutenção de efeitos por 15 dias.
Resumo:
Background and aims: The extent and molecular mechanisms governing plasma extravasation and formation of ascites in cirrhosis are unknown. Vascular endothelial growth factor-A (VEGF-A) and angiopoietin-2 (Ang-2) are endogenous substances with powerful vascular permeability effects. We assessed regional blood flow, vascular leakage, mRNA and tissular expression of VEGF-A and Ang-2 and vascular permeability following VEGF receptor 2 blockade in control and cirrhotic rats to define the vascular territories showing altered vascular permeability in cirrhosis and to determine whether VEGF-A and Ang-2 are involved in this phenomenon. Methods: Arterial blood flow was analysed with the coloured microsphere method. Vascular leakage was measured and visualised with the dye Evan¿s Blue and colloidal carbon techniques, respectively. VEGF-A and Ang-2 expression were determined by real-time polymerase chain reaction (RT-PCR), immunohistochemistry and western blot. The effect on vascular permeability induced by VEGFR2 blockade was assessed by administration of the receptor inhibitor SU11248. Results: Arterial blood flow was increased in the mesentery, pancreas and small intestine but not in the kidney and spleen of cirrhotic rats as compared to controls. Increased vascular leakage was observed in the mesentery and liver, where colloidal carbon spread from microvessels to the adjacent fibrotic tracts. Increased hepatic and mesenteric expression of VEGF-A and Ang-2 was found in cirrhotic rats as compared to controls. Blockade of VEGFR2 markedly reduced hepatic and mesenteric vascular leakage in cirrhotic rats. Conclusions: Enhanced endothelial permeability is restricted to the hepatic and mesenteric vascular beds in cirrhotic rats with ascites and VEGF-A and Ang-2 are key factors in the signalling pathways regulating this dysfunction.
Resumo:
Power leakage properties and guiding conditions of rib antiresonant reflecting optical waveguides (rib-ARROW) have been theoretically and experimentally studied as a function of wavelength and polarization of the light for different geometrical and optical parameters that characterize the rib-ARROW structure. Obtained results show that rib-ARROWs can only be fabricated with low losses in a wavelength range when determined rib configurations are adopted. Furthermore, these waveguides exhibit a polarization sensitivity that largely depends on the core-substrate refractive index difference. Together with the experimental results, theoretical calculations from different modeling methods are also presented and discussed.
Resumo:
Objective: Impaired blood flow of the gastric tube represents a major cause of anastomotic leakage after esophageal resection. In order to improve local vascularisation, preoperative embolization (PE) of the left gastric artery has recently been proposed. The aimof this study was to assess our initial experience of this novel approach with a particular focus on anastomotic leakage.Methods: A consecutive series of 102 patients (81 male, 21 female, median age 64 years) underwent resection (82 Ivor-Lewis procedures, 9 transhiatal resections, 11 triple incisions) for esophageal malignancies at our institution from 2000 to 2009. Since 2004, PE was used selectively in 19 patients 21 days prior to elective esophagectomy. Selection criteria were normal gastric vascular anatomy, no pre-existing vascular disease, i.e. atheromatosis of the celiac trunk or superior mesenteric artery, and resectability of the tumor. PE was performed under local anesthesia on a dedicated system in a standard fashion. Following percutaneous transfemoral visceral angiography to identify gastric vascular anatomy, embolization was performed either with 5-F or with coaxial 3-F catheters and fibered metal coils. We analyzed retrospectively patient's data, operative data, and outcome from a prospective database.Results: The overall anastomotic leakage rate was 18・6% (19/102 patients); cervical anastomosis had a leak rate of 25% compared to intrathoracic anastomosis leak rate of 18・2%. While 17 of 83 patients without PE developed anastomotic leakage (20・5%), there were only 2 of 19 patients after PE revealing an anastomotic leakage (10・5%). Otherwise, patients with PE had no more other complications. There was only one PE-related complication (i.e. partial splenic necrosis).Mean hospital stay was 25 days versus 27 days for patients with PE and without PE, respectively. The mortality rate was 7・8% (8/102 patients), whereby four deaths were related to anastomotic leakage (1 and 3 patients with PE and without PE, respectively).Conclusion: PE is an interesting novel approach to improve gastric blood flow in order to minimize anastomotic leakage. Its application is safe and technically easy. Our preliminary experience revealed a decrease of the anastomotic leakage rate of almost 50%.
Resumo:
Com o objetivo de avaliar o desempenho das agulhas de calibres 14 e 12 na obtenção de "core biopsies" da mama sob controle estereotáxico, os autores compararam biópsias de lesões mamárias impalpáveis obtidas com agulhas desses calibres quanto ao tamanho dos fragmentos e freqüência dos tipos de lesões diagnosticadas. De um total de 1.009 biópsias, os autores analisaram 900 obtidas por agulhas 14 e 109 obtidas por agulhas 12, para análise da freqüência das lesões. Os tamanhos dos fragmentos foram analisados nos 700 primeiros casos para os espécimes obtidos por agulhas 14. A utilização de agulhas 12 resultou em maior tamanho dos fragmentos (p < 0,001), ausência de material insatisfatório, redução na proporção das lesões benignas não-neoplásicas (p = 0,03) e aumento na freqüência de carcinomas (p < 0,001), tanto in situ como invasivos. Tais achados podem refletir aumento da acurácia do diagnóstico, em virtude da maior quantidade de material e/ou melhor seleção radiológica das biópsias obtidas por agulhas 12, pela utilização coincidente da mamografia digital em campo limitado (estereotaxia digital).
Resumo:
The action of herbicides that affect the integrity of cell membranes and cause leakage, like PPO-inhibitors, can be detected by measuring the electric conductivity (EC) of a solution in which the plant tissue target is incubated in the presence of herbicide. The objectives of this work were to confirm PPO resistance in a new Euphorbia heterophylla (EPHHL) biotype, and to compare the electrolyte leakage from R and S to PPO-inhibitors biotypes, using two different methods of incubation in a solution containing herbicides. One experiment was carried in greenhouse and three in laboratory, with a completely randomized design. In the greenhouse experiment, four biotypes of EPHHL were sprayed with seven rates of fomesafen to confirm resistance in suspected biotypes. Leaf disks from R and S EPHHL biotypes in the second and the third experiments and entire leaves in the fourth experiment were incubated in a solution containing PPO-inhibitors to subsequently determine EC of solution. The study confirmed the resistance to PPO-inhibitors in two EPHHL biotypes. There were no significant differences between S and R biotypes in the experiments with the incubation of leaf disks, but incubation of entire leaves of EPHHL S biotype showed higher EC when in a solution with fomesafen, in comparison to the R biotype. The results of this work are an indirect evidence that resistance to PPO-inhibitors is related to lower absorption of herbicide by the shoots and also to some kind of mechanism to cope with oxidative stress.
Resumo:
We investigate the effect of the epitaxial structure and the acceptor doping profile on the efficiency droop in InGaN/GaN LEDs by the physics based simulation of experimental internal quantum efficiency (IQE) characteristics. The device geometry is an integral part of our simulation approach. We demonstrate that even for single quantum well LEDs the droop depends critically on the acceptor doping profile. The Auger recombination was found to increase stronger than with the third power of the carrier density and has been found to dominate the droop in the roll over zone of the IQE. The fitted Auger coefficients are in the range of the values predicted by atomistic simulations.