993 resultados para 768


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Secondary carbonate minerals were recovered within the basalts at both ODP Sites 768 and 770 in the Sulu and Celebes seas. Petrographic and X-ray diffraction analyses indicate that the carbonates are calcites. Other alteration products recognized in the thin sections are smectites, iron oxides, and gypsum. The 13C values of carbonates from both sites range from 1.6 per mil to 2.3 per mil, which are indicative of inorganic carbonate formation with no contributions from 13C-depleted sources such as oxidized organic carbon or methane. The oxygen isotopes at Site 770 range from 30.8 per mil to 31.6 per mil, which indicates a pervasive circulation of cold seawater (9° to 12°C) during alteration of the Celebes Sea basalts. In contrast, carbonates associated with Site 768 basalts have less positive d18O values (21.0 per mil to 27.3 per mil). A lighter 18O isotopic signature indicates the formation of secondary calcite at either higher temperatures or in a system closed to seawater. The rapidly deposited pyroclastic flows at Site 768 would have limited water access to the crust very soon after its formation, which leads us to speculate that the carbonates in the Sulu Sea basalts were formed by isotopically modified fluids resulting from basalt alteration in a closed system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trägerband: Inc. qu. 576; Inc. oct. 358; Vorbesitzer: Dominikanerkloster Frankfurt am Main

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Machine vision represents a particularly attractive solution for sensing and detecting potential collision-course targets due to the relatively low cost, size, weight, and power requirements of the sensors involved (as opposed to radar). This paper describes the development and evaluation of a vision-based collision detection algorithm suitable for fixed-wing aerial robotics. The system was evaluated using highly realistic vision data of the moments leading up to a collision. Based on the collected data, our detection approaches were able to detect targets at distances ranging from 400m to about 900m. These distances (with some assumptions about closing speeds and aircraft trajectories) translate to an advanced warning of between 8-10 seconds ahead of impact, which approaches the 12.5 second response time recommended for human pilots. We make use of the enormous potential of graphic processing units to achieve processing rates of 30Hz (for images of size 1024-by- 768). Currently, integration in the final platform is under way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Machine vision represents a particularly attractive solution for sensing and detecting potential collision-course targets due to the relatively low cost, size, weight, and power requirements of vision sensors (as opposed to radar and TCAS). This paper describes the development and evaluation of a real-time vision-based collision detection system suitable for fixed-wing aerial robotics. Using two fixed-wing UAVs to recreate various collision-course scenarios, we were able to capture highly realistic vision (from an onboard camera perspective) of the moments leading up to a collision. This type of image data is extremely scarce and was invaluable in evaluating the detection performance of two candidate target detection approaches. Based on the collected data, our detection approaches were able to detect targets at distances ranging from 400m to about 900m. These distances (with some assumptions about closing speeds and aircraft trajectories) translate to an advanced warning of between 8-10 seconds ahead of impact, which approaches the 12.5 second response time recommended for human pilots. We overcame the challenge of achieving real-time computational speeds by exploiting the parallel processing architectures of graphics processing units found on commercially-off-the-shelf graphics devices. Our chosen GPU device suitable for integration onto UAV platforms can be expected to handle real-time processing of 1024 by 768 pixel image frames at a rate of approximately 30Hz. Flight trials using manned Cessna aircraft where all processing is performed onboard will be conducted in the near future, followed by further experiments with fully autonomous UAV platforms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 2010 Native American Indigenous Studies Conference was held at The Westin La Paloma Resort, Tucson, Arizona, USA from 20-22 May. The conference was scholarly and interdisciplinary and intended for Indigenous and non-Indigenous scholars who work in American Indian/ Native American/ First Nations/ Aboriginal/ Indigenous Studies. The 2010 gathering attracted 768 registrations from the USA, Canada, Hawaii, Mexico, New Zealand and Australia and other countries. This paper is a personal reflection and overview of the 2010 Conference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study Design. A sheep study designed to compare the accuracy of static radiographs, dynamic radiographs, and computed tomographic (CT) scans for the assessment of thoracolumbar facet joint fusion as determined by micro-CT scanning. Objective. To determine the accuracy and reliability of conventional imaging techniques in identifying the status of thoracolumbar (T13-L1) facet joint fusion in a sheep model. Summary of Background Data. Plain radiographs are commonly used to determine the integrity of surgical arthrodesis of the thoracolumbar spine. Many previous studies of fusion success have relied solely on postoperative assessment of plain radiographs, a technique lacking sensitivity for pseudarthrosis. CT may be a more reliable technique, but is less well characterized. Methods. Eleven adult sheep were randomized to either attempted arthrodesis using autogenous bone graft and internal fixation (n = 3) or intentional pseudarthrosis (IP) using oxidized cellulose and internal fixation (n = 8). After 6 months, facet joint fusion was assessed by independent observers, using (1) plain static radiography alone, (2) additional dynamic radiographs, and (3) additional reconstructed spiral CT imaging. These assessments were correlated with high-resolution micro-CT imaging to predict the utility of the conventional imaging techniques in the estimation of fusion success. Results. The capacity of plain radiography alone to correctly predict fusion or pseudarthrosis was 43% and was not improved using plain radiography and dynamic radiography with also a 43% accuracy. Adding assessment by reformatted CT imaging to the plain radiography techniques increased the capacity to predict fusion outcome to 86% correctly. The sensitivity, specificity, and accuracy of static radiography were 0.33, 0.55, and 0.43, respectively, those of dynamic radiography were 0.46, 0.40, and 0.43, respectively, and those of radiography plus CT were 0.88, 0.85, and 0.86, respectively. Conclusion. CT-based evaluation correlated most closely with high-resolution micro-CT imaging. Neither plain static nor dynamic radiographs were able to predict fusion outcome accurately. © 2012 Lippincott Williams & Wilkins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In an aging population, healthcare providers should understand the foodservice preferences of the elderly to reduce the risk of malnutrition through adequate nutrition. Conflicting reports exist for elderly patient satisfaction regarding foodservice.1 This study aimed to investigate the relationship between age and foodservice satisfaction within the acute care hospital setting. Patient satisfaction was assessed using the Acute Care Hospital Foodservice Patient Satisfaction Questionnaire with data collected over three years (2008–2010, n = 785) at The Wesley Hospital, Brisbane. Age was grouped into three categories; <50, 51–70 and >70 years. ANOVA was used to measure age related differences in patients’ overall foodservice satisfaction, four foodservice dimensions and two independent statements (meal size and hot food temperature). Results showed that older patients were more satisfied than younger patients and indicated increasing satisfaction with increasing age regarding food quality (F2,767 = 15.787, p < 0.001), staff/service issues (F2,768 = 12.243, p < 0.001), physical environment (F2,765 = 5.454, p = 0.004), meal size (F2,730 = 10.646, p < 0.001) and hot food temperature (F2,730 = 10.646, p < 0.001). While patients aged >70 years also reported greater satisfaction with meal service quality, those aged 51–70 years indicated the lowest (F2,762 = 9.988, p < 0.001). Overall patient satisfaction across all age groups was high (4.26–4.43/5) and a trend of increasing satisfaction with increasing age was evident (F2,752 = 2.900, p = 0.056). These findings suggest patients’ satisfaction with hospital foodservice increases with age and can assist foodservices to meet the varying generational expectations of their clients.