245 resultados para 320900 Optometry
Resumo:
PCA/FA is a method of analyzing complex data sets in which there are no clearly defined X or Y variables. It has multiple uses including the study of the pattern of variation between individual entities such as patients with particular disorders and the detailed study of descriptive variables. In most applications, variables are related to a smaller number of ‘factors’ or PCs that account for the maximum variance in the data and hence, may explain important trends among the variables. An increasingly important application of the method is in the ‘validation’ of questionnaires that attempt to relate subjective aspects of a patients experience with more objective measures of vision.
Resumo:
The key to the correct application of ANOVA is careful experimental design and matching the correct analysis to that design. The following points should therefore, be considered before designing any experiment: 1. In a single factor design, ensure that the factor is identified as a 'fixed' or 'random effect' factor. 2. In more complex designs, with more than one factor, there may be a mixture of fixed and random effect factors present, so ensure that each factor is clearly identified. 3. Where replicates can be grouped or blocked, the advantages of a randomised blocks design should be considered. There should be evidence, however, that blocking can sufficiently reduce the error variation to counter the loss of DF compared with a randomised design. 4. Where different treatments are applied sequentially to a patient, the advantages of a three-way design in which the different orders of the treatments are included as an 'effect' should be considered. 5. Combining different factors to make a more efficient experiment and to measure possible factor interactions should always be considered. 6. The effect of 'internal replication' should be taken into account in a factorial design in deciding the number of replications to be used. Where possible, each error term of the ANOVA should have at least 15 DF. 7. Consider carefully whether a particular factorial design can be considered to be a split-plot or a repeated measures design. If such a design is appropriate, consider how to continue the analysis bearing in mind the problem of using post hoc tests in this situation.
Resumo:
1. The techniques associated with regression, whether linear or non-linear, are some of the most useful statistical procedures that can be applied in clinical studies in optometry. 2. In some cases, there may be no scientific model of the relationship between X and Y that can be specified in advance and the objective may be to provide a ‘curve of best fit’ for predictive purposes. In such cases, the fitting of a general polynomial type curve may be the best approach. 3. An investigator may have a specific model in mind that relates Y to X and the data may provide a test of this hypothesis. Some of these curves can be reduced to a linear regression by transformation, e.g., the exponential and negative exponential decay curves. 4. In some circumstances, e.g., the asymptotic curve or logistic growth law, a more complex process of curve fitting involving non-linear estimation will be required.
Resumo:
Purpose: This cross-sectional study was designed to determine whether the academic performance of optometry undergraduates is influenced by enrolment status, learning style or gender. Methods: Three hundred and sixty undergraduates in all 3 years of the optometry degree course at Aston University during 2008–2009 were asked for their informed consent to participate in this study. Enrolment status was known from admissions records. An Index of Learning Styles (http://www4.nscu.edu/unity/lockers/users/f/felder/public/Learning-Styles.html) determined learning style preference with respect to four different learning style axes; active-reflective, sensing-intuitive, visual-verbal and sequential-global. The influence of these factors on academic performance was investigated. Results: Two hundred and seventy students agreed to take part (75% of the cohort). 63% of the sample was female. There were 213 home non-graduates (entrants from the UK or European Union without a bachelor’s degree or higher), 14 home graduates (entrants from the UK or European Union with a bachelor’s degree or higher), 28 international non-graduates (entrants from outside the UK or European Union without a bachelor’s degree or higher) and 15 international graduates (entrants from outside the UK or European Union with a bachelor’s degree or higher). The majority of students were balanced learners (between 48% and 64% across four learning style axes). Any preferences were towards active, sensing, visual and sequential learning styles. Of the factors investigated in this study, learning styles were influenced by gender; females expressed a disproportionate preference for the reflective and visual learning styles. Academic performance was influenced by enrolment status; international graduates (95% confidence limits: 64–72%) outperformed all other student groups (home non graduates, 60–62%; international non graduates, 55–63%) apart from home graduates (57–69%). Conclusion: Our research has shown that the majority of optometry students have balanced learning styles and, from the factors studied, academic performance is only influenced by enrolment status. Although learning style questionnaires offer suggestions on how to improve learning efficacy, our findings indicate that current teaching methods do not need to be altered to suit varying learning style preferences as balanced learning styles can easily adapt to any teaching style (Learning Styles and Pedagogy in Post-16 Learning: A Systematic and Critical Review. London, UK: Learning and Skills Research Centre, 2004).
Resumo:
The objective of this study was to investigate the effects of circularity, comorbidity, prevalence and presentation variation on the accuracy of differential diagnoses made in optometric primary care using a modified form of naïve Bayesian sequential analysis. No such investigation has ever been reported before. Data were collected for 1422 cases seen over one year. Positive test outcomes were recorded for case history (ethnicity, age, symptoms and ocular and medical history) and clinical signs in relation to each diagnosis. For this reason only positive likelihood ratios were used for this modified form of Bayesian analysis that was carried out with Laplacian correction and Chi-square filtration. Accuracy was expressed as the percentage of cases for which the diagnoses made by the clinician appeared at the top of a list generated by Bayesian analysis. Preliminary analyses were carried out on 10 diagnoses and 15 test outcomes. Accuracy of 100% was achieved in the absence of presentation variation but dropped by 6% when variation existed. Circularity artificially elevated accuracy by 0.5%. Surprisingly, removal of Chi-square filtering increased accuracy by 0.4%. Decision tree analysis showed that accuracy was influenced primarily by prevalence followed by presentation variation and comorbidity. Analysis of 35 diagnoses and 105 test outcomes followed. This explored the use of positive likelihood ratios, derived from the case history, to recommend signs to look for. Accuracy of 72% was achieved when all clinical signs were entered. The drop in accuracy, compared to the preliminary analysis, was attributed to the fact that some diagnoses lacked strong diagnostic signs; the accuracy increased by 1% when only recommended signs were entered. Chi-square filtering improved recommended test selection. Decision tree analysis showed that accuracy again influenced primarily by prevalence, followed by comorbidity and presentation variation. Future work will explore the use of likelihood ratios based on positive and negative test findings prior to considering naïve Bayesian analysis as a form of artificial intelligence in optometric practice.
Resumo:
Background: Previous work has shown that medical problems can be diagnosed by practitioners using Google. The aim of this study was to determine whether optometry students would benefit from using Google when diagnosing eye diseases. Methods: Participants were given symptoms and signs and instructed to list three key words and use them to search Aston University e-Library and Google UK. Results: Aston University e-Library only search resulted in correct diagnosis in 16 of 60 simulated cases. Aston e-Library plus Google search resulted in correct diagnosis in 31 of 60 simulated cases. Conclusion: Google is a useful aid to help optometry students improve their success rate when diagnosing eye conditions.
Resumo:
Purpose: To determine whether constriction of proximal arterial vessels precedes involution of the distal hyaloid vasculature in the mouse, under normal conditions, and whether this vasoconstriction is less pronounced when the distal hyaloid network persists, as it does in oxygen-induced retinopathy (OIR). Methods: Photomicrographs of the vasa hyaloidea propria were analysed from pre-term pups (1-2 days prior to birth), and on Days 1-11 post-birth. The OIR model involved exposing pups to similar to 90% O-2 from D1-5, followed by return to ambient air. At sampling times pups were anaesthetised and perfused with india ink. Retinal flatmounts were also incubated with FITC-lectin (BS-1, G. simplicifolia,); this labels all vessels, allowing identification of vessels not patent to the perfusate. Results: Mean diameter of proximal hyaloid vessels in preterm pups was 25.44 +/- 1.98 mum; +/-1 SEM). Within 3-12 hrs of birth, significant vasoconstriction was evident (diameter:12.45 +/- 0.88 mum), and normal hyaloid regression subsequently occurred. Similar vasoconstriction occurred in the O-2-treated group, but this was reversed upon return to room air, with significant dilation of proximal vessels by D7 (diameter: 31.75 +/- 11.99 mum) and distal hyaloid vessels subsequently became enlarged and tortuous. Conclusions: Under normal conditions, vasoconstriction of proximal hyaloid vessels occurs at birth, preceding attenuation of distal hyaloid vessels. Vasoconstriction also occurs in O-2-treated pups during treatment, but upon return to room air, the remaining hyaloid vessels dilate proximally, and the distal vessels become dilated and tortuous. These observations support the contention that regression of the hyaloid network is dependent, in the first instance, on proximal arterial vasoconstriction.
Resumo:
Purpose. To demonstrate that the combination of impression cytology and single cell DNA fingerprinting represents a powerful tool that is suitable for detecting transplanted cells after corneal limbal allografting. Methods, Fifty single cells were obtained by corneal impression cytology from 12 patients undergoing cataract surgery. Individual cells were isolated from samples by micromanipulation. Polymerase chain reaction and short tandem repeat profiling was used to obtain forensic standard DNA fingerprints from single cells. Blood samples taken at the time of impression cytology provided control fingerprints. Results, informative DNA fingerprints were obtained from all corneal samples and 66% (33 of 50 cells) of isolated single cells, Of all fingerprints obtained, most (91%, 30 of 33 fingerprints) corneal fingerprints matched corresponding blond sample fingerprints. At least one corneal fingerprint matched the corresponding blood sample fingerprint in 83% (10 of 12 patients) of the patients in the study, Conclusions. This extremely specific single cell DNA fingerprinting system permits accurate identification of individual corneal epithelial cells, allowing very reliable determination of their origin, which will enable host and donor cells to be distinguished from each other after keratolimbal allografting procedures. even if the host and donor are the same sex or siblings. These DNA fingerprinting methods allow assessment of quality and quantity of donor cell survival, as well as survival time. The extreme sensitivity and accuracy of the technique means that should contamination occur, it would be identified, thus ensuring meaningful results.
Resumo:
Purpose. To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). Methods. This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (J) coefficient for quantitative and ordinal variables, respectively. Results. Fourteen subjects were recruited in each city with a mean (TSD) age of 63.0 (T1.7) and 59.1 (T0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and J values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p Q 0.75) despite RH values significantly differing (p e 0.005). Significant (p e 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 T 0.60 vs. 5.26 T 0.64 seconds; higher RH visit, 2.61 T 0.32 vs. 5.78 T 0.88 seconds) and corneal (middle RH, 0.64 T 0.17 vs. 0.14 T 0.10; higher RH, 0.60 T 0.22 vs. 0.0 T 0.0) and conjunctival staining (middle RH, 0.61 T 0.17 vs. 0.14 T 0.08; higher RH, 0.57 T 0.15 vs. 0.18 T 0.09). Conclusions. This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated. (Optom Vis Sci 2015;92:e284Ye289)
Resumo:
Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.
Resumo:
Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.