997 resultados para 25-degrees-c
Resumo:
Small angle X-ray scattering measurements, bulk and skeleton density data and an in-situ study by dilatometric thermal analysis about the nanoporosity elimination above 800 degreesC in TEOS sonogels are presented. Apparently, two processes act during the nanoporosity elimination, which precedes the foaming phenomenon often observed in such systems. The first, with an activation energy of (3.9 +/- 0.4) x 10(2) kJ/mol and high frequency factor, is the controlling process of the most nanoporosity elimination at higher temperature. The value of this activation energy is compatible to that for viscous flux throughout densification process in typical silica-based materials. The second, with an activation energy of (49 +/- 5) kJ/mol and low frequency factor, seems to be the controlling process of the first and extremely slow nanoporosity elimination at low temperature.
Resumo:
Silica xerogels were prepared from sonohydrolysis of tetraethoxysilane and exchange of the liquid phase of the wet gel by acetone. Monolithic xerogels were obtained by slow evaporation of acetone. The structural characteristics of the xerogels were studied as a function of temperature up to 1100 degrees C by means of bulk and skeletal density measurements, linear shrinkage measurements and thermal analyses (DTA, TG and DL). The results were correlated with the evolution in the UV-Vis absorption. Particularly, the initial pore structure of the dried acetone-exchanged xerogel was studied by small-angle X-ray scattering and nitrogen adsorption. The acetone-exchanged xerogels exhibit greater porosity in the mesopore region presenting greater mean pore size (similar to 4 nm) when compared to non-exchanged xerogels. The porosity of the xerogels is practically stable in the temperature range between 200 degrees C and 800 degrees C. Evolution in the structure of the solid particles (silica network) is the predominant process upon heating up to about 400 degrees C and pore elimination is the predominant process above 900 degrees C. At 1000 degrees C the xerogels are still monolithic and retain about 5 vol.% pores. The xerogels exhibited foaming phenomenon after hold for 10 h at 1100 degrees C. This temperature is even higher than that found for foaming of non-exchanged xerogels. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conveyor belts are widely used in food handling areas, especially in poultry processing plants. Because they are in direct contact with food and it is a requirement of the Brazilian health authority, conveyor belts are required to be continuously cleaned with hot water under pressure. The use of water in this procedure has been questioned based on the hypothesis that water may further disseminate microorganisms but not effectively reduce the organic material on the surface. Moreover, reducing the use of water in processing may contribute to a reduction in costs and emission of effluents. However, no consistent evidence in support of removing water during conveyor belt cleaning has been reported. Therefore, the objective of the present study was to compare the bacterial counts on conveyor belts that were or were not continuously cleaned with hot water under pressure. Superficial samples from conveyor belts (cleaned or not cleaned) were collected at three different times during operation (T1, after the preoperational cleaning [5 a.m.]; T2, after the first work shift [4 p.m.]; and T3, after the second work shift [1:30 a.m.]) in a poultry meat processing facility, and the samples were subjected to mesophilic and enterobacterial counts. For Enterobacteriaceae, no significant differences were observed between the conveyor belts, independent of the time of sampling or the cleaning process. No significant differences were observed between the counts of mesophilic bacteria at the distinct times of sampling on the conveyor belt that had not been subjected to continuous cleaning with water at 45 degrees C. When comparing similar periods of sampling, no significant differences were observed between the mesophilic counts obtained from the conveyor belts that were or were not subjected to continuous cleaning with water at 45 degrees C. Continuous cleaning with water did not significantly reduce microorganism counts, suggesting the possibility of discarding this procedure in chicken processing.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Estimation of the lower flammability limits of C-H compounds at 25 degrees C and 1 atm; at moderate temperatures and in presence of diluent was the objective of this study. A set of 120 degrees C H compounds was divided into a correlation set and a prediction set of 60 compounds each. The absolute average relative error for the total set was 7.89%; for the correlation set, it was 6.09%; and for the prediction set it was 9.68%. However, it was shown that by considering different sources of experimental data the values were reduced to 6.5% for the prediction set and to 6.29% for the total set. The method showed consistency with Le Chatelier's law for binary mixtures of C H compounds. When tested for a temperature range from 5 degrees C to 100 degrees C , the absolute average relative errors were 2.41% for methane; 4.78% for propane; 0.29% for iso-butane and 3.86% for propylene. When nitrogen was added, the absolute average relative errors were 2.48% for methane; 5.13% for propane; 0.11% for iso-butane and 0.15% for propylene. When carbon dioxide was added, the absolute relative errors were 1.80% for methane; 5.38% for propane; 0.86% for iso-butane and 1.06% for propylene. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
The thermoluminescence intensity as a function of gamma-ray dose of the 325 degreesC peak, in quartz grains extracted from sea sediments and from fluvial aeolic dunes, is studied. It is found that the response curve at low doses has a concavity directed opposite to that of quartz grains extracted from archaeological potteries. To explain this behavior a model is proposed here based on oxygen vacancies and [AlO4/h](0) centers. The experimentally observed ESR intensity of E-I'-centers as a function of radiation dose can also be explained by this model.
Resumo:
Carbon-supported Pt-based electrocatalysts were synthesized by Pechini method for the ethanol oxidation (EOR). Physicochemical characterizations were helpful to estimate the diameters of the obtained materials ranging from 2 nm to 5 nm. Main electrochemical experiments were carried out at 90 degrees C i.e. under the working conditions of performing the single 5 cm(2) direct ethanol fuel cell (DEFC). Pt(80)Sn(20)/C was the anode catalyst which has given the highest power density of 37 mW cm(-2). Importantly, the IR spectroscopy measurements associated with the qualitative analysis done at the output of the anodic compartment of the fuel cell have shown that ethanol oxidation on Pt(80)Sn(20)/C was mainly a two-electron sustainable process. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
AIMS: Data on moderately cold water immersion and occurrence of arrhythmias in chronic heart failure (CHF) patients are scarce. METHODS AND RESULTS: We examined 22 male patients, 12 with CHF [mean age 59 years, ejection fraction (EF) 32%, NYHA class II] and 10 patients with stable coronary artery disease (CAD) without CHF (mean age 65 years, EF 52%). Haemodynamic effects of water immersion and swimming in warm (32 degrees C) and moderately cold (22 degrees C) water were measured using an inert gas rebreathing method. The occurrence of arrhythmias during water activities was compared with those measured during a 24 h ECG recording. Rate pressure product during water immersion up to the chest was significantly higher in moderately cold (P = 0.043 in CHF, P = 0.028 in CAD patients) compared with warm water, but not during swimming. Rate pressure product reached 14200 in CAD and 12 400 in CHF patients during swimming. Changes in cardiac index (increase by 5-15%) and oxygen consumption (increase up to 20%) were of similar magnitude in moderately cold and warm water. Premature ventricular contractions (PVCs) increased significantly in moderately cold water from 15 +/- 41 to 76 +/- 163 beats per 30 min in CHF (P = 0.013) but not in CAD patients (20 +/- 33 vs. 42 +/- 125 beats per 30 min, P = 0.480). No ventricular tachycardia was noted. CONCLUSION: Patients with compensated CHF tolerate water immersion and swimming in moderately cold water well. However, the increase in PVCs raises concerns about the potential danger of high-grade ventricular arrhythmias.