977 resultados para -Compact categories
Resumo:
The study aims to find the categories of risks disclosed in the Administration Reports of Brazilian companies with the issuance of ADR`s. The research is characterized as descriptive, accomplished through doucmentary analysis. The sample includes 28 Brazilian companies with the issuance of American Depository Receipt (ADR`s) in the Stock Exchange of New York (USA). We have tried to identify the categories of risk, presented by the companies surveyed in the Administration Reports (AR) of 2007. Seven categories of corporate risks were considered, identified through COSO (2004) methodology strategic risks, operational risks, legal risks and image risks,. The survey results show that in general there is no standaardization of the types sof risks disclosed by the companies. A total of 14 types of risks havd been identified. The predominant category in the disclosure was the operational risk, with 20.72% of the observations. There was no disclosre of image risk in the AR of the companies surveyed. It was found that 19 companies, 67.86% of the surveyed companies, demonstrate some kind of risk to which they are exposed. On the other hand, nine companies (32.14%) did not show any kind of risk.
Resumo:
A free-piston driver that employs entropy-raising shock processes with diaphragm rupture has been constructed, which promises significant theoretical advantages over isentropic compression. Results from a range of conditions with helium and argon driver gases are reported. Significant performance gains were achieved in some test cases. Heat losses are shown to have a strong effect on driver processes. Measurements compare well with predictions from a quasi-one-dimensional numerical code.
Resumo:
Mainstream concepts of homelessness do not serve Indigenous people well. Those designing policies or programs for Indigenous homeless people may need to re-think or change their concepts of homeless in order to adequately understand and respond to the needs of this group of people.
Resumo:
The scoring of occupational categories has along history. After reviewing the historical background, we develop and discuss the properties of two new Australian scales based on current theorising in stratification research. The first is based on the operation of the labour market and scores occupations to reflect their central role in converting educational credentials into market income. The second is based on patterns of social interaction and scores occupations to reflect the choices that people make in marriage markets. While these two scales are not theoretically or empirically equivalent, they are closely related and provide equally valid, but alternative, ways of measuring the underlying stratification order of modern societies.
Resumo:
In this work, a new method of optimization is successfully applied to the theoretical design of compact, actively shielded, clinical MRI magnets. The problem is formulated as a two-step process in which the desired current densities on multiple, cc-axial surface layers are first calculated by solving Fredholm equations of the first kind. Non-linear optimization methods with inequality constraints are then invoked to fit practical magnet coils to the desired current densities. The current density approach allows rapid prototyping of unusual magnet designs. The emphasis of this work is on the optimal design of short, actively-shielded MRI magnets for whole-body imaging. Details of the hybrid numerical model are presented, and the model is used to investigate compact, symmetric, and asymmetric MRI magnets. Magnet designs are presented for actively-shielded, symmetric magnets of coil length 1.0 m, which is considerably shorter than currently available designs of comparable dsv size. Novel, actively-shielded, asymmetric magnet designs are also presented in which the beginning of a 50-cm dsv is positioned just 11 cm from the end of the coil structure, allowing much improved access to the patient and reduced patient claustrophobia. Magn Reson Med 45:331540, 2001. (C) 2001 Wiley-Liss, Inc.
Resumo:
New designs for force-minimized compact high-field clinical MRI magnets are described. The design method is a modified simulated annealing (SA) procedure which includes Maxwell forces in the error function to be minimized. This permits an automated force reduction in the magnet designs while controlling the overall dimensions of the system. As SA optimization requires many iterations to achieve a final design, it is important that each iteration in the procedure is rapid. We have therefore developed a rapid force calculation algorithm. Novel designs for short 3- and 4-T clinical MRI systems are presented in which force reduction has been invoked. The final designs provide large homogeneous regions and reduced stray fields in remarkable short magnets. A shielded 4-T design that is approximately 30% shorter than current designs is presented. This novel magnet generates a full 50-cm diameter homogeneous region.
Resumo:
Some results are obtained for non-compact cases in topological vector spaces for the existence problem of solutions for some set-valued variational inequalities with quasi-monotone and lower hemi-continuous operators, and with quasi-semi-monotone and upper hemi-continuous operators. Some applications are given in non-reflexive Banach spaces for these existence problems of solutions and for perturbation problems for these set-valued variational inequalities with quasi-monotone and quasi-semi-monotone operators.
Resumo:
Water wetting is a crucial issue in carbon dioxide (CO.) corrosion of multiphase flow pipelines made from mild steel. This study demonstrates the use of a novel benchtop apparatus, a horizontal rotating cylinder, to study the effect of water wetting on CO2 corrosion of mild steel in two-phase flow. The setup is similar to a standard rotating cylinder except for its horizontal orientation and the presence of two phases-typically water and oil. The apparatus has been tested by using mass-transfer measurements and CO2 corrosion measurements in single-phase water flow. CO2 corrosion measurements were subsequently performed using a water/hexane mixture with water cuts varying between 5% and 50%. While the metal surface was primarily hydrophilic under stagnant. conditions, a variety of dynamic water wetting situations was encountered as the water cut and fluid velocity were altered. Threshold velocities were identified at various water cuts when the surface became oil-wet and corrosion stopped.