999 resultados para vision


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The recently completed Chinese "Million Cataract Surgeries Program" (MCSP) is among the largest such campaigns ever, providing 1.05 million operations. We report MCSP outcomes for the first time, in Jiangxi, the province with the greatest program output. Methods: Ten county hospitals participating in MCSP were selected in Jiangxi (range of gross domestic product per capita US$743-2998). Each hospital sought to enroll 75 consecutive MCSP patients aged ≥50 years. Data recorded included type of cataract procedure, bilateral uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), and refractive error pre- and ≥50 days postoperatively. Results: Among 715 patients (mean age 72.3±9.1 years, 55.5% female), preoperative UCVA was <3/60 (legally blind) bilaterally in 13.3% and unilaterally in the operated eye in 50.9%. No subjects had UCVA >6/18 preoperatively. Small incision cataract surgery was performed in 92.3% patients. Among 662 patients (92.6%) completing follow-up was ≥ 40 days after surgery, BCVA was ≥6/18 in 80.1%, UCVA was ≥6/18 in 57.1% and UCVA was <3/60 in 2.1%. Older age (p<0.001), female sex (p=0.04), worse refractive error (p=0.02) and presence of intra- (p=0.002) and postoperative surgical complications (p<0.001), were independently associated with worse postoperative UCVA. Based on these results, the MCSP cured an estimated 124,950 cases (13.3%×[100-2.1%]×1.05 million) of bilateral and 502,500 (50.9%×[100-2.1%]×1.05 million) of unilateral blindness. Conclusions: Due to relatively good outcomes and the large number of surgeries performed on blind persons, the sight-restoring impact of the MCSP was probably substantial. © Informa Healthcare USA, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To study the effect of posterior capsular opacification (PCO) on vision and visual function in patients undergoing cataract surgery in rural China, and to compare this with the effect of refractive error. METHODS: Patients undergoing cataract surgery in at least one eye by local surgeons in a rural setting between 8 August and 31 December 2005 were examined with slit lamp grading of PCO 10-14 months after surgery. Subjects with any PCO associated with best-corrected visual acuity of 6/7.5 or worse, or with grade 2+ or worse PCO without visual decrement, were offered YAG laser capsulotomy. Vision and self-reported visual function were assessed, and various demographic and clinical factors potentially associated with PCO were recorded. RESULTS: Of 313 patients operated on within the study window, 239 (76%) could be contacted by telephone; study examinations were performed on 176 (74%). Examined subjects had a mean (SD) age of 69.4 (10.5) years, 116 (67%) were female, and 149 (86%) had been blind (presenting visual acuity < or = 6/60) in the operated eye before surgery. PCO of grade 1 or above was present in 34 of 204 operated eyes (16.7%). Those with PCO had significantly worse presenting vision (p = 0.007) but not visual function (p>0.3) than those without PCO. Women had a significantly higher prevalence of PCO (20.9%) than did men (8.6%, p<0.05). Of 19 eyes undergoing capsulotomy with best-corrected visual acuity measured the next day, 13 (68%) improved by one or more lines, and seven (37%) improved by two or more lines. Despite a higher uptake of capsulotomy (95%) as opposed to refraction (35%) in this cohort, the yield in terms of eyes with poor presenting visual acuity (< 6/18) that could be improved was higher for refraction (26% = 9/35) than for capsulotomy (9% = 3/35). CONCLUSION: The prevalence of PCO and impact on vision and visual function in this cohort was modest 1 year after surgery. However, PCO prevalence increases with time. Follow-up of this cohort is underway to determine the effectiveness of this early intervention in identifying and treating subjects who will eventually experience clinically significant PCO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. METHODS: After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. RESULTS: Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. CONCLUSIONS: Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Presbyopia limits activities of daily living, but population-based data from rural China are scarce. METHODS: A population-based, cross-sectional study was conducted in 2009 among all persons aged 40+ years in a rural area near Shenyang, China. Distance and near VA were measured using logMAR E charts. Individuals with pinhole-corrected distance vision ≥20/63 underwent detailed eye examination and near refraction. RESULTS: A total of 1008 (91.5%) respondents were examined (mean age, 58.4 ± 10.7 years for men, 56.8 ± 9.89 years for women). Women and older subjects were more likely to participate. The prevalence of functional presbyopia (near vision <20/50 [N8] improved by ≥1 line with correction) was 67.3% (95% confidence interval [CI], 64.30%-70.09%), increasing from 27.6% at 40 to 49 years of age to 81.8% at 60 to 69 years. Multivariate analysis showed that older age (P < 0.001), but not gender or education, was significantly associated with a higher risk of presbyopia. Self-reported presbyopic spectacle correction coverage was 51.5%. In multivariate logistic regression models, worse presenting near vision (P = 0.013) and higher required spherical equivalent power (P < 0.001) were associated with having correction, while age, gender, education, and distance vision were unassociated. Major barriers reported by persons without near correction included poor quality of available glasses (33.1%) and lack of awareness of the condition and its treatment (28.8%). CONCLUSIONS: Presbyopia is highly prevalent in rural China, and nearly half of affected persons have no access to correction. Interventions should focus on education and improvement in the quality of refractive services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the impact of near-vision impairment on visual functioning and quality of life in a rural adult population in Shenyang, northern China. METHODS: A population-based, cross-sectional study was conducted among persons aged 40+ years, during which functional presbyopia (correctable presenting near vision < 20/50 [N8] at 40 cm) was assessed. Near-vision-related quality of life and spectacle usage questionnaires were administered by trained interviewers to determine the degree of self-rated difficulty with near tasks. RESULTS: A total of 1008 respondents (91.5% of 1102 eligible persons) were examined, and 776 (78%) of completed the questionnaires (mean age, 57.0 ± 10.2 years; 63.3% women). Near-vision spectacle wearers obtained their spectacles primarily from markets (74.5%) and optical shops (21.7%), and only 1.14% from eye clinics. Among 538 (69.3%) persons with functional presbyopia, self-rated overall (distance and near) vision was worse (P < 0.001) and difficulty with activities of daily living greater (P < 0.001) than among nonpresbyopes. Odds of reporting any difficulty with daily tasks remained higher (OR = 2.32; P < 0.001) for presbyopes after adjustment for age, sex, education and distance vision. Compared to persons without presbyopia, presbyopic persons were more likely to report diminished accomplishment due to vision (P = 0.01, adjusted for age, sex, education, and distance vision.) CONCLUSIONS: Difficulties with activities of daily living and resulting social impediments are common due to presbyopia in this setting. Most spectacle wearers with presbyopia in rural China obtain near correction from sources that do not provide comprehensive vision care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ticks as vectors of several notorious zoonotic pathogens, represent an important and increasing threat for human, animal health in Europe. Recent application of new technology revealed the complexity of the tick microbiome that might impact upon its vectorial capacity. Appreciation of these complex systems is expanding our vision of tick-borne pathogens leading us to evolve a more integrated view that embraces the “pathobiome” representing the pathogenic agent integrated within its abiotic and biotic environments. In this review, we will explore how this new vision will revolutionize our understanding of tick-borne diseases. We will discuss the implications in terms of research approach for the future in order to efficiently prevent and control the threat posed by ticks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Painterly rendering has been linked to computer vision, but we propose to link it to human vision because perception and painting are two processes that are interwoven. Recent progress in developing computational models allows to establish this link. We show that completely automatic rendering can be obtained by applying four image representations in the visual system: (1) colour constancy can be used to correct colours, (2) coarse background brightness in combination with colour coding in cytochrome-oxidase blobs can be used to create a background with a big brush, (3) the multi-scale line and edge representation provides a very natural way to render fi ner brush strokes, and (4) the multi-scale keypoint representation serves to create saliency maps for Focus-of-Attention, and FoA can be used to render important structures. Basic processes are described, renderings are shown, and important ideas for future research are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are roughly two processing systems: (1) very fast gist vision of entire scenes, completely bottom-up and data driven, and (2) Focus-of-Attention (FoA) with sequential screening of specific image regions and objects. The latter system has to be sequential because unnormalised input objects must be matched against normalised templates of canonical object views stored in memory, which involves dynamic routing of features in the visual pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are developing a frontend that is based on the image representation in the visual cortex and plausible processing schemes. This frontend consists of multiscale line/edge and keypoint (vertex) detection, using models of simple, complex and end-stopped cells. This frontend is being extended by a new disparity model. Assuming that there is no neural inverse tangent operator, we do not exploit Gabor phase information. Instead, we directly use simple cell (Gabor) responses at positions where lines and edges are detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de dout., Engenharia Electrónica e de Computadores, Faculdade de Ciência e Tecnologia, Universidade do Algarve, 2007

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a monocular vision system for a navigation aid. The system assists blind persons in following paths and sidewalks, and it alerts the user to moving obstacles which may be on collision course. Path borders and the vanishing point are de-tected by edges and an adapted Hough transform. Opti-cal flow is detected by using a hierarchical, multi-scale tree structure with annotated keypoints. The tree struc-ture also allows to segregate moving objects, indicating where on the path the objects are. Moreover, the centre of the object relative to the vanishing point indicates whether an object is approaching or not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Attention is usually modelled by sequential fixation of peaks in saliency maps. Those maps code local conspicuity: complexity, colour and texture. Such features have no relation to entire objects, unless also disparity and optical flow are considered, which often segregate entire objects from their background. Recently we developed a model of local gist vision: which types of objects are about where in a scene. This model addresses man-made objects which are dominated by a small shape repertoire: squares, rectangles, trapeziums, triangles, circles and ellipses. Only exploiting local colour contrast, the model can detect these shapes by a small hierarchy of cell layers devoted to low- and mid-level geometry. The model has been tested successfully on video sequences containing traffic signs and other scenes, and partial occlusions were not problematic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonic, infrared, laser and other sensors are being applied in robotics. Although combinations of these have allowed robots to navigate, they are only suited for specific scenarios, depending on their limitations. Recent advances in computer vision are turning cameras into useful low-cost sensors that can operate in most types of environments. Cameras enable robots to detect obstacles, recognize objects, obtain visual odometry, detect and recognize people and gestures, among other possibilities. In this paper we present a completely biologically inspired vision system for robot navigation. It comprises stereo vision for obstacle detection, and object recognition for landmark-based navigation. We employ a novel keypoint descriptor which codes responses of cortical complex cells. We also present a biologically inspired saliency component, based on disparity and colour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-scale representations of lines, edges and keypoints on the basis of simple, complex and end-stopped cells can be used for object categorisation and recognition (Rodrigues and du Buf, 2009 BioSystems 95 206-226). These representations are complemented by saliency maps of colour, texture, disparity and motion information, which also serve to model extremely fast gist vision in parallel with object segregation. We present a low-level geometry model based on a single type of self-adjusting grouping cell, with a circular array of dendrites connected to edge cells located at several angles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SmartVision prototype is a small, cheap and easily wearable navigation aid for blind and visually impaired persons. Its functionality addresses global navigation for guiding the user to some destiny, and local navigation for negotiating paths, sidewalks and corridors, with avoidance of static as well as moving obstacles. Local navigation applies to both in- and outdoor situations. In this article we focus on local navigation: the detection of path borders and obstacles in front of the user and just beyond the reach of the white cane, such that the user can be assisted in centering on the path and alerted to looming hazards. Using a stereo camera worn at chest height, a portable computer in a shoulder-strapped pouch or pocket and only one earphone or small speaker, the system is inconspicuous, it is no hindrence while walking with the cane, and it does not block normal surround sounds. The vision algorithms are optimised such that the system can work at a few frames per second.