990 resultados para transmission rates
Resumo:
This paper is on a simulation for offshore wind systems in deep water under cloud scope. The system is equipped with a permanent magnet synchronous generator and a full-power three-level converter, converting the electric energy at variable frequency in one at constant frequency. The control strategies for the three-level are based on proportional integral controllers. The electric energy is injected through a HVDC transmission submarine cable into the grid. The drive train is modeled by a three-mass model taking into account the resistant stiffness torque, structure and tower in the deep water due to the moving surface elevation. Conclusions are taken on the influence of the moving surface on the energy conversion. © IFIP International Federation for Information Processing 2015.
Resumo:
Interaction between Paracoccidioides brasiliensis (Pb) and inflammatory cells in hamster testis was studied sequentially by transmission electron microscopy. In early lesions (six hours after inoculation), polymorphonuclear neutrophils (PMNs) were the major and mononuclear cells and eosinophils were the minor constituents of the inflammatory cells. PMNs were later replaced by mononuclear cells. Viable Pb cells were phagocytosed or surrounded by inflammatory cells. Preserved Pb cells usually had broad host-parasite interphases, whereas dying ones had narrow interphases. The outer layer of the fungus wall was sometimes broken by PMN in some focal points, broken pieces being peeled off and phagocytosed. Small Pb cells were uninuclear, and were often related to broad interphase. Large Pb cells were multinucleated with irregularly shaped wall, and sometimes had lomasome and/or myelin like structures. Different interaction patterns of Pb with inflammatory cells may be due to functionally different host cell flow to the inoculation site or due to the age of Pb cells or both.
Resumo:
Nearly 400 hemodialysis patients treated at 5 different hemodialysis units in Rio de Janeiro were tested for one year for the presence of hepatitis C and B markers. During the same period, samples were also obtained from 35 continuous ambulatory peritoneal dialysis (CAPD) patients and from 242 health care workers. Depending on the hemodialysis unit studied, anti-HCV prevalence rates ranging from 47% to 82% (mean 65%) were detected. CAPD patients showed a lower prevalence of 17%. The prevalence of antibodies against hepatitis C virus (anti-HCV) among health care workers was 2.9%. We observed a hepatitis C attack rate of 11.5% per year in the anti-HCV-negative hemodialysis patient population. An average of 9.4% of the hemodialysis patients were chronic carriers of hepatitis B virus (HBV) (range 1.8% - 20.4%), while 48.9% showed markers of previous HBV infection. The HBV attack rate was 4.5% per year (range 0% - 6%). These results indicate an alarming high prevalence of anti-HCV among hemodialysis patients of this studied region.
Resumo:
According to the hedonic price method, a price of a good is related with the characteristics or the services it provides. Within this framework, the aim of this study it is to examine the effect on room rates of different characteristics of hotels in and around the city of Porto, such as star category, size, room and service quality, hotel facilities and location. It was estimated a hedonic price function, using data for 51 hotels. The results enable to identify the attributes that are important to consumers and hoteliers and to which extent. This information can be used by hotel managers to define a price strategy and helpful in new investment decisions.
Resumo:
As the wireless cellular market reaches competitive levels never seen before, network operators need to focus on maintaining Quality of Service (QoS) a main priority if they wish to attract new subscribers while keeping existing customers satisfied. Speech Quality as perceived by the end user is one major example of a characteristic in constant need of maintenance and improvement. It is in this topic that this Master Thesis project fits in. Making use of an intrusive method of speech quality evaluation, as a means to further study and characterize the performance of speech codecs in second-generation (2G) and third-generation (3G) technologies. Trying to find further correlation between codecs with similar bit rates, along with the exploration of certain transmission parameters which may aid in the assessment of speech quality. Due to some limitations concerning the audio analyzer equipment that was to be employed, a different system for recording the test samples was sought out. Although the new designed system is not standard, after extensive testing and optimization of the system's parameters, final results were found reliable and satisfactory. Tests include a set of high and low bit rate codecs for both 2G and 3G, where values were compared and analysed, leading to the outcome that 3G speech codecs perform better, under the approximately same conditions, when compared with 2G. Reinforcing the idea that 3G is, with no doubt, the best choice if the costumer looks for the best possible listening speech quality. Regarding the transmission parameters chosen for the experiment, the Receiver Quality (RxQual) and Received Energy per Chip to the Power Density Ratio (Ec/N0), these were subject to speech quality correlation tests. Final results of RxQual were compared to those of prior studies from different researchers and, are considered to be of important relevance. Leading to the confirmation of RxQual as a reliable indicator of speech quality. As for Ec/N0, it is not possible to state it as a speech quality indicator however, it shows clear thresholds for which the MOS values decrease significantly. The studied transmission parameters show that they can be used not only for network management purposes but, at the same time, give an expected idea to the communications engineer (or technician) of the end-to-end speech quality consequences. With the conclusion of the work new ideas for future studies come to mind. Considering that the fourth-generation (4G) cellular technologies are now beginning to take an important place in the global market, as the first all-IP network structure, it seems of great relevance that 4G speech quality should be subject of evaluation. Comparing it to 3G, not only in narrowband but also adding wideband scenarios with the most recent standard objective method of speech quality assessment, POLQA. Also, new data found on Ec/N0 tests, justifies further research studies with the intention of validating the assumptions made in this work.
Resumo:
The most frequent form of acquisition of Chagas' disease in endemic areas was the transmission through the feces of contaminated triatominae. However, special attention should be paid in urban areas to transmission by blood transfusion, justifying the compulsory screening of blood donors. Early investigations at blood banks in the town of Londrina, Brazil, demonstrated that the seroprevalence of anti-Trypanosoma cruzi antibodies among blood donors was approximately 7.0% in the fifties9,34. Further studies demonstrated pratically the same seroprevalence until the eighties4,32,41. In an attempt to obtain data about the real dimension of the seropositivity for anti-Trypasonoma cruzi antibodies in the region, the authors carried out a large-scale study on 45,774 serum samples from blood donors of the Hemocentro of Hospital Universitário Regional do Norte do Paraná (HURNP), Universidade Estadual de Londrina. The immunological tests were done at the Division of Clinical Immunology of HURNP from May 1990 to December 1994. The serum samples were studied by the indirect hemagglutination assay (IHA, using kits commercially obtained from EBRAM) and by indirect immunofluorescence (IFI, using kits from LIO SERUM) with anti-human IgG conjugate (LABORCLIN). The results demonstrated that 643 serum samples were positive in both assay corresponding to a seroprevalence of 1.4%, i.e., a significant decrease in anti-Trypanosoma cruzi antibodies in the region in comparison with the previously mentioned rates. Data correlating sex and age of seropositive blood donors are presented, as well as the possible factors that may have contributed to the results observed.
Resumo:
Most of distribution generation and smart grid research works are dedicated to the study of network operation parameters, reliability among others. However, many of this research works usually uses traditional test systems such as IEEE test systems. This work proposes a voltage magnitude study in presence of fault conditions considering the realistic specifications found in countries like Brazil. The methodology considers a hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzyprobabilistic models and a remedial action algorithm which is based on optimal power flow. To illustrate the application of the proposed method, the paper includes a case study that considers a real 12 bus sub-transmission network.
Resumo:
In this work, the impact of distributed generation in the transmission expansion planning will be simulated through the performance of an optimization process for three different scenarios: the first without distributed generation, the second with distributed generation equivalent to 1% of the load, and the third with 5% of distributed generation. For modeling the expanding problem the load flow linearized method using genetic algorithms for optimization has been chosen. The test circuit used is a simplification of the south eastern Brazilian electricity system with 46 buses.
Resumo:
Most of distributed generation and smart grid research works are dedicated to network operation parameters studies, reliability, etc. However, many of these works normally uses traditional test systems, for instance, IEEE test systems. This paper proposes voltage magnitude and reliability studies in presence of fault conditions, considering realistic conditions found in countries like Brazil. The methodology considers a hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models and a remedial action algorithm which is based on optimal power flow. To illustrate the application of the proposed method, the paper includes a case study that considers a real 12-bus sub-transmission network.
Resumo:
The diagnostic potential of circulating IgM and IgA antibodies against Schistosoma mansoni gut-associated antigens detected by the immunofluorescence test (IFT) on adult worm paraffin sections was evaluated comparatively to the fecal parasitological method, for epidemiological purposes in low endemic areas for schistosomiasis. Blood samples were collected on filter paper from two groups of schoolchildren living in two different localities of the municipality of Itariri (São Paulo, Brazil) with different histories and prevalences of schistosomiasis. The parasitological and serological data were compared to those obtained for another group of schoolchildren from a non-endemic area for schistosomiasis. The results showed poor sensitivity of the parasitological method in detecting individuals with low worm burden and indicate the potential of the serological method as an important tool to be incorporated into schistosomiasis control and vigilance programs for determining the real situation of schistosomiasis in low endemic areas.
Resumo:
The vertical transmission of the human T-cell lymphotropic virus type I (HTLV-I) occurs predominantly through breast-feeding. Since some bottle-fed children born to carrier mothers still remain seropositive with a frequency that varies from 3.3% to 12.8%, an alternative pathway of vertical transmission must be considered. The prevalence rate of vertical transmission observed in Japan varied from 15% to 25% in different surveys. In Brazil there is no evaluation of this form of transmission until now. However, it is known that in Salvador, Bahia, 0.7% to 0.88% of pregnant women of low socio-economic class are HTLV-I carriers. Furthermore the occurrence of many cases of adult T-cell leukemia/lymphoma and of four cases of infective dermatitis in Salvador, diseases directly linked to the vertical transmission of HTLV-I, indicates the importance of this route of infection among us. Through prenatal screening for HTLV-I and the refraining from breast-feeding a reduction of ~ 80% of vertical transmission has been observed in Japan. We suggest that in Brazil serologic screening for HTLV-I infection must be done for selected groups in the prenatal care: pregnant women from endemic areas, Japanese immigrants or Japanese descendents, intravenous drug users (IDU) or women whose partners are IDU, human immunodeficiency virus carriers, pregnant women with promiscuous sexual behavior and pregnant women that have received blood transfusions in areas where blood donors screening is not performed. There are in the literature few reports demonstrating the vertical transmission of HTLV-II.
Resumo:
In order to determine Schistosoma mansoni infection rates in Biomphalaria tenagophila and B. straminea, low stringency polymerase chain reaction (LS-PCR) technique was used as a complementary method to light exposure technique. LS-PCR has already been standardized in our laboratory to detect the trematode DNA in B. glabrata. Higher S. mansoni infection rates were detected using conventional method and LS-PCR. The parasite DNA profile was detected in both species after 7-day exposure to miracidia, using LS-PCR. This technique enables early detection of schistosomiasis transmission focuses, in endemic areas, before the beginning of cercariae shedding.