999 resultados para special fibers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We numerically investigate four-wave-mixing (FWM) based multichannel wavelength conversion for amplitude-modulated signals, phase-modulated signals, together with mixed amplitude and phase modulated signals. This paper also discusses the influence of stimulated Brillouin scattering (SBS) effects on high-efficiency FWM-based wavelength conversion applications. Our simulation results show that DPSK signals are more suitable for FWM-based multichannel wavelength conversion because the OOK signals will suffer from the inevitable datapattern-dependent pump depletion. In future applications, when the modulation format is partially upgraded from OOK to DPSK, the influence of OOK signals on the updated DPSK signals must be considered when using multichannel wavelength conversion. This influence becomes severe with the increase of OOK channel number. It can be concluded that DPSK signals are more appropriate for both transmission and multichannel wavelength conversion,especially in long haul and high bit-rate system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High birefringence induced by rhombic air-hole photonic crystal fibers (PCFs) is numerically analyzed by using the finite-element method. The birefringence of a few kinds of PCFs was investigated with different parameters related to rhombic holes, including the rhombic-hole shape, size, and spacing. It was found that the birefringence of the proposed rhombic-hole PCF in this study is relatively larger than that of an elliptical-hole PCF with the same air-filling fraction (f = 0.0375) when the ratio of the rhombic-hole diagonal length is equal to the elliptical-hole ellipticity. (C) 2010 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports that the transmission of O6+ ions with energy of 150keV through capillaries in an uncoated Al2O3 membrane was measured, and agreements with previously reported results in general angular distribution of the transmitted ions and the transmission fractions as a function of the tilt angle well fitted to Gaussian-like functions were observed. Due to using an uncoated capillary membrane, our c is larger than that using a gold-coated one with a smaller value of E-p/q, which suggests a larger equilibrium charge Q(infinity) in our experiment. The observed special width variation with time and a larger width than that using a smaller E-p/q were qualitatively explained by using mean-field classical transport theory based on a classical-trajectory Monte Carlo simulation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: